Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹88.2 LAccepted-AOC D NO 39 12 27 1 3 MURALI NAGAR VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹89.6 L+₹1.4 L (1.60%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹90.5 L+₹2.3 L (2.63%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹94.8 L+₹6.6 L (7.45%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹1.1 Cr+₹18.8 L (21.3%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
26 Jul 2022, 6:00 pmClosed
GE (I) (DM)
GE (I) (DM) NAVAL DOCKYARD VISAKHAPATNAM 530014
SPECIAL REPAIRS TO GANGA BLOCK EXCLUDING TOILETS (BLDG NO P-47) COY DSC AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) DM VISAKHAPATNAM
2022_MES_526115_2
SSGE/8723/E8
Open Tender
Civil Works
Item Rate
450 days
NAVAL DOCKYARD VISAKHAPATNAM
As per tender documents
8 documents required · 8 mandatory
₹1,000
GE (I) (DM) VISAKHAPATNAM
₹1.9 L
Yes
30 Aug 2022
24 Jun 2022
2 Aug 2022
24 Jun 2022
26 Jul 2022
1 Jul 2022
Amount
[SCHEDULE 'A' PART-I [B/R WORKS]
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish outside ND(V) premises complete all as specified and as directed.
M&L light shade virified ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick 1:6 cement morter including roughning surface of old concrete floor by picking sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3 kg of cement per sqm complete all as specified and as directed
M&L light shade virified ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles (before cutting if required) exceeding 0.18 sqm but not exceeding 0.38 sqm, in vertical surfaces of wall/skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick 1:3 cement morter including roughning surface of old concrete floor by picking sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3 kg of cement per sqm complete all as specified and as directed
Material machine cut kota stone slab flooring over cement concrete base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing, including 20 mm thick screed bed in CM 1:6, complete, all as specified.
Material & labour for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Material & labour for rounding to edges of granite stone slabs one edge such as in counter type WHB platform etc., complete all as specified and as directed.
Taking down chowkats or frames with shutter (without taking off shutter from the frames) n.exc 1.50 Sqm each complete all as specified and directed.
Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm n.exc 4 Sqm each complete all as specified and directed.
Supply and fix aluminium door shutter with chowkats mad out of hollow aluminium sections as mentioned below, each shutter having 2 Nos. ‘D’ type aluminium handles of 200 mm long, 2 Nos. aluminium tower bolts of 200 mm long and 1 No. mortice lock of 6 lever with key in duplicate, regulated by double action hydraulic floor door spring, shutter partly glazed with 5 mm thick sheet glass and partly paneled with 12 mm thick pre-laminated particle board fixed with glazing clips, rubber beadings and aluminium beading complete all as specified and as directed. Chowkat size : 101.60 x 44.45 x 2.40 mm (1.608 Kg./RM appx.) Shutter Top rail : 114.30 x 2.15 mm thick (1.836 Kg./RM appx.) Bottom rail : 150.00 x 2.20 mm thick (2.376 Kg./RM appx.) Middle rail : 83.50 x 1.70 mm thick (1.243 Kg./RM appx.) Vertical rail : 85.00 x 1.80 mm thick (1.302 Kg./RM appx.)
Supply and Fixed Aluminium powder coated decorative grill of design DG-104 or equivalent having not less than 2.15 Kg/sqm and fixed with steel screws in and including anodized aluminium 'U' shape frame work complete all as specified and as directed.
Supply & Fix powder coated anodized aluminium window and ventilator shutter, side hung type / top hung without sash bar,aluminium section wighing 0.55 kg/M including necessary jointing cleats, glazing clips, rubber packing handles 2 Nos, 2 Nos 100mm long tower bolt 2 Nos Hinges of 100 mm size typeB-21, in each shutter, and anodised aluminium snab beading screws etc., complete all as specified and as directed.
S&F sheet glass frosted 4 mm thick ordinary quality fixed with aluminium beads in squares not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Cleaning the concrete surface by removing dirt and debris, making defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete all as directed
M&L water proofing treatment on cleaned RCC roof comprising with the following operation and as specified here-in-below :- (a) 20 mm thick (av. mimimum thickness) plastering in cement mortar 1:3 with water proofing compound @ 4% by weight of cement finishing the plastered surfaces even and smooth over cleaned RCC roof. The plastered surface shall be cured properly for ten days by ponding of water over roof. (b) Applying bitumen primer over the plastered surface @ 0.40 Ltr / Sqm by the same membrane manufacturer of density at 25°C, 0.87 to 0.89 kg / Liter and viscosity 70-160 cps. (c) Providing and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 3.6 kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt make as approved over the primer coat. Membrane shall be laid using butane torch and sealing all joints etc all as per Para 11.44.5 of SSR Part I. (d) Applying one coat of Aluminium paint @ 0.1 ltr per Sqm over APP based polymetric membrane complete all as per manufacturer's instruction.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L brick work with sub class 'B' bricks straight or curved in plan exc 6 mtr mean radius built in CM (1:6) using old size bricks complete all as specified and as directed.
Pre-cast cement concrete 1:3:6 type C1(using 20 mm graded crushedstone aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6) complete all as specified and directed.
Material & labour for chipping (20mm to 50mm) of existing damaged, crakced, spalled & loose portion of concrete of the RCC members completely till the reinforcement is exposed and sound concrete is observed by using mechanical means and manual chisels and further the surface is cleaned with water jet, again clean the surface with blower to remove all loose fine particles present in the surfaces and for removal of dust and loose particles complete all as specified and as directed.. Note : Work shall be executed on any floor up to five floors or 16m height of buildings
M&L for preparation of exposed surafces of rusted steel reinforcement with metal wire brush,cleaning the rusted surfaces free from loose rust and applying rust remover cum passivator (Sika Rustoff 100 @ 0.20Kg / Sqm or any other equivalent approved make of E -in -C's branch) on surface of existing reinforcement with brush to the rusted reinforcemnet , removing rust with flex after 24 hours of application of rust remover with the help of wire brush, sand paper and throughly washed with water with the help of pressure jet and allowing surfaces of steel it to dry complete all as specified and directed. . Note:- Area of cleaned reinforcement steel bar shall only be considered for payment Density: 1.01 Kg/l at 300C
Preparation of surfaces of steel of reinforcement by cleaning thruoghly and proving , mixing and aplying zinc anti-rust agent as per manufacturers method of application to rebar corrosion protection system to reinforcement ( Sika / Fosroc/BASF/ Dr sunanda) @3.75Kg/Sqm surface of steel reinforcement in two coats complete all as specified and as directed..
Material & labour applying a coat of Polymer modified cementious bonding coat on the concrete surfaces with one part of Styrene Butadiene Rubber latex emulsion (SBR latex) manufactured by M/s Fosroc chemicals or equivalent chemicals manufactured by Sika India Pvt Ltd / Choksey Chemicals Pvt. Lt with four parts of water and six parts of cement by weight.Coverage of SBR latex-0.25Ltr / sqm for one coat complete all as specified and as directed.
Providing proposed rebars,mild steel TMT bars of different diameter for Coulmn , beams, slab, chajja, drop, parapets encasement , as detailed in sketch including fabricating, placing, tieing, fixing etc., cut to length bent to shape as required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia and welding to existing steel reinforcement complete all as specified and as directed.
Material & labour for providing Shear connectors and Anchoring by drilling 16 mm dia holes up to depth of 100mm in concrete surfaces and fixing 10 mm dia TMT bars L shaped anchor rods as shear connectors by using Fosroc Lokfix chemical (Mix of base and hardener of the polyester resin) in defective concrete area of the slab / column / beams / chajjas / lintel etc or any other structural member as per site requirement after cleaning the drilled hole by using water jet and after drying clean the surface with blower to remove all loose fine particles present in the hole. The Mix of base and hardener of the polyester resin shall be prepared by thorough mixing of base & hardener by the help of spatula. After preparing the mix the holes shall be filled to a minimum depth of 1/3rd of the hole with the prepared polyester resin and the reinforced bar shall be inserted to full depth of hole and extra length of the reinforcement bar shall be bent into the concrete to maintain proper cover to the reinforcement complete all as specified and directed.
Use and waste of form work to the columns, beams, chajjas, drops, fins, parapets etc for the proposed micro concrete encasement as in fair finished surfaces complete all as specified and directed
Material & labour Micro-concrete prepared by construction chemicals manufactured by Fosroc / Sika / Choksey Chemicals cement based pre packed single component, chloride free, sulphate free, non-shrink, free flow, self compacting , ready to use after mixing water in specified proportion of approved quality.to achive high strength, dual shrinkage, compensated, micro concrete with compresive strength of 40 Mpa at 28 days of thickness of 50mm to 200mm for concrete reapir work complete all as specified and directed. (Note :- 1. Form work shall be provided for palcing micro concrete patch repair as required at site with steel jack sysytem and steel props to support the form work .2. Form work shall be measured and paid separately.under respective items in this schedule)
M&L for application of polymer modified reinstatement mortar 20mm thick in isolated palces of repair works of RCC members with Rendroc S2 of M/s Fosroc make or equivalent in Sika / Choksey having a compressive strength of M40 grade complete all as specified and as directed.
M&L for applying polymer modified, cementitious mortar fibre reinforced, single component shrinkage controlled, (Renderoc SP40 of Fosroc Make or equivalent in Sika / Choksey) having a compressive strength of 40 MPA strength for reparing of RCC members like columns, Beams / Slab soffits etc. complete all as specified and directed.
Demolition of cement concrete (un reinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) and removing debries out side to Dockyard premesis complete all as specified and as directed.
M&L hard core of broken stone of gauge n. exc. 63 mm, deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rammed to a true surface all as specified and directed.
M&L 75 mm thick cement concrete 1:3:6 Type C2 (using 40 mm graded crushed stone aggregate) in floors (plinth protection) finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
Taking down cement plaster on brick or concrete wall etc including racking out joint hacking for key, scrubbing down with water etc. complete all as specified and as directed.
M&L rendering 15 mm thick in CM 1:6 on brick/concrete wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed
M&L rendering 15 mm thick in CM 1:4 using SBR Latex emulsion @ 4% by weight of cement on concrete surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed (Note : 1.Make of SBR emulsion / latex :: Sika, Fosroc, STP,Dr Sunanada, BASF, Star Coatings or any other approved make of E-in-cS branch . 2. Cost of SBR Latexis included i with plastering)
M&L rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings and finishing surfaces even and smooth without using extra cement complete all as specified and as directed
M&L for preparation of new plastered surface of walls and applying two coats of oil bound distemper over a coat of primer over a coat of cement based wall putty minimun thickness 1.5mm and cutting to smooth surfaces by sand paper complete all as specified and directed.
M & L preparation of newly plastered surfaces of walls and applying two coats of exterior emulsion paint (weather coat) over a coat of alkali resistance primer over a coat of cement based wall putty minimun thickness 1.5mm and cutting to smooth surfaces by sand paper complete all as specified and directed.
M&L preparing new surfaces of ceiling and applying two coats of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and directed.
M & LComplete removal of existing treatment of old decorated surfaces of walls and applying two coats of oil emulsion distemper over a coat of alkali resistant primer over a coat of cement based wall putty minimun thickness 1.5mm and cutting to smooth surfaces by sand paper complete all as specified and directed.
M & L Complete removal of existing treatment of old decorated surfaces of walls and applying two coats of exterior emulsion paint (weather coat) over a coat of alkali resistance primer over a coat of cement based wall putty minimun thickness 1.5mm and cutting to smooth surfaces by sand paper complete all as specified and directed.
M&L for Complete removal of existing treatment of old decorated surfaces of ceiling and applying two coats of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and directed. complete all as specified and as directed.
Dismantling wrought iron or MS work of any description not otherwise provided, complete all as specified and directed.
M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channel, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed.
M&L M.S. Rolled sections (beam, tee, angle channel or flat section) as in stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. complete grade of steel Fe-410-W (Gde - E-250), quality - A complete all as specified and directed.
S&F 2nd class hardwood plain solid, straight chowkat and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complere all as specified and directed.
Preparing surfaces of wood and wood based materials new of any description and girth not otherwise described and treating with tar or coal tar black paint at ends of post back of chowkats etc complere all as specified and directed.
S&F mild steel flat iron as in hold fast for door window frames or chowkat/wind ties etc. cut to length or drilled hole and fixed with screw etc. complete all as directed grade of steel conforming to Fe-290, Gde-E-165.
M&L PCC 1:2:4 type B1(20 mm graded stone aggregate) as in bed block for embedding hold fast of doors, window frames or chowkats including necessary form work complete all as all as specified directed.
Preparing surfaces of wood and wood based materials, steel or ironwork, new of any description and girth not otherwise described and treating with tar or coal tar black paint for small articles such as stop, covers, gully gratings, holdfasts, ends of posts, back of chowkats etc. area tarred n. exc. 0.10 Sqm each.
M&L sanding newly tarred or painted surfaces with clean sharp sand all as specified and as directed.
S&F 35 mm thick factory made flush shutters solid core construction, with particle board core and ply wood face panels commercial type on both sides complete all as specified and as directed.
S&F 35 mm thick, 2nd class hardwood glazed and skeleton shutters, open rebated and prepare to receive gauge etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for secruing glass/gauge etc size of member of shutter as specified in SSR Part-I Section 8 Clause 8.24(a), fitted to chowkats complete all as directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or stainless steel wire staple complete all as specified and as directed.
S&F 2nd class hard wood small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labours, articles not exceeding 200 Cucm each complete all as specified and as directed.
Supply only Stainless Steel butt hinges medium weight of size 50 mm complete all as specified and as directed.
S&F Stainless Steel butt hinges medium weight of size 100 mm complete all as specified and directed.
S&F 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and as directed.
S&F Extruded aluminium alloy handles 150 mm long fabricated type anodised complete all as specified and as directed .
S&F 300 mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
M&L preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
S&F rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top) hoisted and fixed in position of 2000 Ltr capacity all as specified in SSR and as directed including taking down old one.
S&F stainless steel curtain rails of 20mm dia, heavy duty fixed with chromium plated bracket, stops rollers etc complete all as specified and directed including taking out old one.
SCHEDULE 'A' PART-II [ELECTRICAL WORKS]
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, with fittings & fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials from the site and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed.
Taking down unserviceable main switches, DBs, bus bars chambers including all fittings and fixtures etc complete from existing main boards and removing from site complete all as specified and directed.
M&L concealed point wiring with 1.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed FRLS copper conductor cable drawn through with and including PVC rigid conduit medium grade with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete fixed to walls etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core copper cable as earth continuity wire connecting to common earth point including supply & fixing of galvanised pressed mild steel Modular Terminal Boxes of suitable size as requires for fixing modular switch / sockets/ regulator etc. complete for one light / Fan / bazzer point controlled by one one way switches complete all as specified and directed including necessary chase cutting for conduits and sinking boxes and making good to walls, floors etc.complete all as specified and directed..
M&L concealed point wiring with 1.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed FRLS copper conductor cable drawn through with and including PVC rigid conduit medium grade with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete fixed to walls etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core copper cable as earth continuity wire connecting to common earth point including supply & fixing of galvanised pressed mild steel Modular Terminal Boxes of suitable size as requires for fixing modular switch / sockets complete for one 3 / 5 pin, 5/6 Amp socket outlet on independent board complete all as specified and directed including necessary chase cutting for conduits and sinking boxes and making good to walls, floors etc.complete all as specified and directed..
M&L concealed point wiring with 2.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed FRLS copper conductor cable drawn through with and including PVC rigid conduit medium grade with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete fixed to walls etc. with and including 2.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core copper cable as earth continuity wire connecting to common earth point including supply & fixing of galvanised pressed mild steel Modular Terminal Boxes of suitable size as requires for fixing modular switch / sockets complete for one 6 pin, 16 Amp socket outlet on independent board complete all as specified and directed including necessary chase cutting for conduits and sinking boxes and making good to walls, floors etc.complete all as specified and directed.
S&F modular switch 6 Amps ,240 volts single pole one way single module conforming to IS complete all as specified and as directed
S&F modular socket 6 Amps 3//5 pin 240 volts,two modules conforming to IS complete all as specified and as directed
S&F modular switch socket combination 16 Amps 6 pin 240 volts 3 modules conforming to IS complete all as specified and as directed
S&F modular electronic fan regulator 2 MODULE ,120 W, conforming to IS complete complete all as specified and as directed
M & L Ceiling rose, surface type polycarbonate/ PVC three terminals, conforming to IS, complete all as specified and as directed.
S&F LED industrial box type LED bitten with CRCA body pre coated with white and prewired suitable for LED tube 2x18/20 watt 4' long along with 2 number of tube included dismantling of taking down.
S& F in Recess mounted indoor decorative direct - indirect LED recessed full open 2 x 2 feet with highly efficient light smoothy optics to deliver superior illuminous and energy saving of 36 watts lighting with integrated electronic driver including connection with suitable 3 core wire from ceiling rose to fitting terminal with necessary fixing arrangement complete all as specified and directed including taking out old one.
S&F SP MCB 6 to 32 Amps C Curve complete all as specified and as directed
S&F TP MCB 63 Amps C Curve complete all as specified and as directed
S&F TPN MCB 63 Amps C Curve complete all as specified and as directed
S&F concealled TPN DB 4 way, double door, with 200 amp rated bus bar complete all as specified and as directed Note:Cutting chases for DB &making good is be included in the quoted rate
M&L Sub main wiring concealed type with two runs of 4.0 sqmm (Nominal area) single core PVC insulated stranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through PVC rigid conduit with all fittings and accessories of PVC rigid conduit complete fixed to wall / ceiling etc incl one run of 4.0 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed including taking out old one. (Note :-(i) PVC rigid conduit with all fittings/accessories shall be measured. (ii) Two runs of 4.0 sqmm single core cable, one run of 4.0 sqmm earth continuity wire to be measured as one length (iii) chase cutting if required shall be measured under under relevant items in this schedule.).
M&L Sub main wiring concealed type with four runs of 10.0 sqmm (Nominal area) single core PVC insulated stranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through PVC rigid conduit with all fittings and accessories of PVC rigid conduit complete fixed to wall / ceiling etc incl one run of 10.0 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed. including taking out old one. (Note :-(i) PVC rigid conduit with all fittings/accessories shall be measured and paid separately. (ii) Four runs of 10.0 sqmm single core cable, one run of 10.0 sqmm earth continuity wire to be measured as one length (iii) chase cutting if required shall be measured and paid separately under relevant items in this schedule.).
M&L Sub main wiring concealed type with four runs of 6.0 sqmm (Nominal area) single core PVC insulated stranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through PVC rigid conduit with all fittings and accessories of PVC rigid conduit complete fixed to wall / ceiling etc incl one run of 6.0 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed. including taking out old one. (Note :-(i) PVC rigid conduit with all fittings/accessories shall be measured. (ii) Four runs of 6.0 sqmm single core cable, one run of 6.0 sqmm earth continuity wire to be measured as one length (iii) chase cutting if required shall be measured and under relevant items in this schedule.).
M&Lconcealed type wiring with two runs of 1.50 sqmm (Nominal area) single core PVC insulated stranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through PVC rigid conduit with all fittings and accessories of PVC rigid conduit complete fixed to wall / ceiling etc incl one run of 1.50 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed. including taking out old one. (Note :-(i) PVC rigid conduit with all fittings/accessories shall be measured and paid separately. (ii) Two runs of 1.50 sqmm single core cable, one run of 1.50 sqmm earth continuity wire to be measured as one length (iii) chase cutting if required shall be measured and under relevant items in this schedule.).
Supply & fixing 20 mm dia medium grade PVC rigid conduit with all fittings and accessories of PVC conduit (like Tee, bend etc.) including taking down old one complete all as specified and directed.
Supply & fixing 25 mm dia medium grade PVC rigid conduit with all fittings and accessories of PVC conduit (like Tee, bend etc.) including taking down old one complete all as specified and directed.
M&L cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps cills, sunshades, shelves, lintels etc. in brick walls and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc. 10 cm girth complete all as specified & directed.
S&F flush type 6 module Power unit consisting of one SPN MCB 20A, one single phase motor starter for over load protection, one heavy duty plug top with indicator & one 3 pin 25A socket assembly complete all as specified and as directed including taking out old one.
S & F metal box 6 Module for mounting power unit complete all as specified and as directed including taking out old one..
M&L Earthing complete with galvanised pipe electrode 40mm bore medium grade, 2.5M long cut tapered at the bottom and provided with 12mm dia (Staggered) at 75mm C/C upto 2M length from bottom buried directly in the ground vertically with its top not less than 1.25m below ground level connected to galvanised iron or steel earth lead MS flat 32 x 6 mm by means of nuts, bolts, check nuts and washers of galvanised iron or steel, earth strip protected by galvanised iron pipe 50 mm dia (light grade) and connected to main switch board or main control panel as directed and as specified including concrete pit in PCC (1:3:6) type C1 pre-cast RCC cover slab 5 cm thick of size as shown reinforced with 8 mm dia TMT / deformed bars 100 mm c/c both ways including one handle made of 12 mm dia MS bars of length 500 mm, funnel, wiremesh 20 mm bore galvanised iron pipe medium grade for watering, charcoal and salt in alternate layers including necessary earth work complete all as shown in elect plate No. 2 of SSR Part I, all as directed.
M&L for energy efficient 90 W LED street / bldg. security light luminaire for road lighting with pressure die-cast aluminium IP66 protection and high power LED as light source with acrylic cover including supply & fixing with 40 mm dia medium grade GI pipe bracket 1.5 mtr long bent to shape, mounted on wall / pole with suitable clamps, bolts, nuts and all accessories complete including connection with 3 core PVC insulated sheathed flexible cable with muyltistranded copper conductor from celing rose to fitting terminal all as specified and as directed including taking down old unserviceable fitting all as specified & directed.
Dismantling burnt winding of ceiling fanof sweep 1400 mm (any size/ sweep/make) and taking out existing winding wire, and rewinding the same after proper cleaning with super enamelled copper winding wire as per existing gauge and turn to achieve the required RPM, cleaning/ replacement of bearings, bushes capacitor etc as required and testing complete all as specified and directed.
Taking down ceiling fan of any size/sweep from existing position & M&L for painting to fan with synthetic enamel paint by spraying including filling cavities with fillar with necessary preparation of surface including hanging the ceiling fan and connecting up complete all as directed.
SRI SIMHADRI COMPANY
SATYAMEGHA ENGINEERS
PRATIMA ENGINEERING WORKS
CIVILEC ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .