Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC GANDHI CHOWK LANSDOWNE 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹8.1 L+₹5,903.15 (0.73%)Rejected-Finance GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL PIN 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹8.3 L+₹23,996.15 (2.98%)Rejected-Finance PAIDI POST FARIDPUR BHOGI NAGINA ROAD BIJNOR UP 246701 | BIJNOR | BIJNOR | UP | 246701 | L3 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹9.7 L
EMD Value
₹19,480
Closing Date
28 Oct 2021, 6:00 pmClosed
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne Distt- Pauri Garhwal Pin-246155
SPECIAL REPAIR TO BLDG NO T-37 (OTM ACCN) AT GBS CAMP KOTDWARA UNDER AGE (I) LANSDOWNE
2021_MES_479098_1
8650/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I Lansdwne
Class E Cat a i
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹19,480
9 Nov 2021
1 Oct 2021
30 Oct 2021
1 Oct 2021
28 Oct 2021
16 Oct 2021
Amount
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position in unframed work complete all as specified and directed.
Ditto in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in unframed work complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc.laid, bedded and pointed in any mortar complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
Taking down chowkhats or frames with shuters (without taking off shutters from the frames) not exc. 1.5 sq m each complete all as specified and directed.
All as per serial Item No 09 here in above but chowkhats or frames exc 1.5 sq. m but n exc 4 sqm each complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M & L for wrought second class hardwood in scantlings complete all as specified and directed.
M & L for second class hardwood in plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads sectional area exc 13 & n exc 25 sqcm complete all as specified and directed.
S&F in repairs E-boards, ceiling, 4 mm thick with J framed work with main Tee of size 24 x 28.5 mm made out of PGI sheet .3 mm thick double at web and single at flange, flange coverd with powder coated sheet 0.25 mm thick and wall angle 24 x 24 x .45 mm powder coated for ceiling , ceiling boards 60cm x 60cm x 4mm thick , suspended with GI wire 2mm dia and 2m average length with adjustable hanging device complete including plugging in brick/stone walls with steel rawl plug @ 600 mm C/C Ceiling board shall be pressed to the ceiling tee with staple clips at all four sides and incl making good of all disturbed/daimage surface of walls and applying two coat of oil bound distemper complete all as spd & directed by GE/Eng-in-Charge.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick, AZ 150 of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick, AZ 150 of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F for mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; hold fasts, framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
M & L for providing 75 mm thick cement concrete type-C-2 1:3:6 (using 40 mm grade stone aggregate) as in plinth protection or similar work complete all as specified and directed.
S &F for 3 mm thick and 38 mm wide glass dividing strips fixed as in floor etc complete all as specified & directed.
M & L for brickwork with subclass ‘B’ old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for machine cut kota stone slab flooring 20-25mm thick over and including 20 mm thick cement screed bed in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including mirror polishing complete all as specified and directed.
M & L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over and including 10 mm thick rendering in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including mirror polishing complete all as specified and directed.
M & L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) in concrete bed for hold fasts, filling door and window frames, copings, kerbs and similar work complete all as specified and directed.
M&L for plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints of IInd class hardwood complete all as specified and directed.
M & L for 35 mm thick IInd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed.
M & L for 40 mm thick IInd class hardwood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers complete all as specified and directed.
S&F for butt hinges mild steel, medium weight of 100mm size complete all as specified and directed.
S & F for 200 mm long (Length of bolt) mild steel barrel tower bolts, stove enamelled black, with bright bolt complete all as specified and directed.
S & F for 100 mm long mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed.
S & F for 250 mm long (Length of bolt) mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
S & F for 300 mm mild steel ordinary rat tail, rod pattern springs including roller and roller plate complete all as specified and directed.
S&F for 3 mm thick glass sheet area of each glass nexc 0.50 sqm,glazing with oil putty or wooden beabs incl., hacking out old broken glass (any thickness, size, quality or description) from wooden frames or steel frame or brick surrounds, glazed with oil putty or fixed with beads including punching or drilling out old glazing pins / spring clips and providing and fixing new ones complete all as specified and directed.
S & F for galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks of galvanised wire staples complete all as specified and directed.
M&L for RCC (Nominal Mix) type B-1, 1:2:4, using (20 mm graded stone agg) for slab, lintel, cover slab complete all as specified and directed.
Use & waste of formwork to sides and soffits of lintels, cantilevers, shelves including supports for rough finished flat surfaces of complete all as specified and directed.
M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick/stone masonary or concrete surfaces in CM(1:6) finished even and smooth without usnig extra cement complete all as specified and directed.
M & L for 15 mm thick rendering in cement mortar 1:4 on brick/stone work or other than fair faces of brick work or one side of lathing or concrete surfaces and finishing the surface fair and even complete all as specified and directed.
M & L for 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in subbase below flooring complete all as specified and directed.
M & L for filling sand cushion under floor or in foundation including watering and consolidation complete all as specified and directed.
M & L for ruber moulded machine pressed precast concrete interlocking paver block any shape and size with colour pigment confirming to IS 15658-2006 of 60mm thickness M-35 grade complete all as specified and directed.
M&L for preparation of new surface of wall and applying two coat of Anti -fungel acrylic emulsion paint Make-Berger (wall masta),or equavlent in Asain or nerolac including one coat of primer complete all as specified by manufacturer complete all as specified and directed by Engineer-in-charge .
M&L for prepairing of new plaster surfaces and applying two coat Acrylic Emulsion paint after applying wall care putty as per manufacturer instruction including a coat of primer white or tinted complete all as specified by manufacturer complete all as specified and directed by Engineer-in-charge.
M&L for Complete removal of existing treatments by mechanised method from wall by scraping and filling the damage portion with wall putty or cement mortar as required at site and applying two coat of Acrylic Emulsion Paint over a coat of primer after applying wall care putty as per manufacturer instructions including preparation of surface, complete all as specified and directed.
M & L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for preparation of new or previously untreated steel and iron surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc. all as specified and directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed rigid PVC conduit(ISI marked) ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) including metal flush box made of GI sheet and white cover complete all as specified and directed for the following. One light/fan/bell point controlled by one No piano type switch 5 Amps single pole one way
All as per serial Item No 48 here in above but One 3 pin 5 Amps socket outlet on same board controlled by one, one way 5 Amps piano switch complete all as specified and directed
All as per serial Item No 48 here in above butOne socket outlet 5/3 pin 5 Amps controlled by one switch on independent board complete all as specified and directed
Material and labour for power point wiring for one 15 Amp switch socket combined outlet point on Independent Board with 2.5 Sqmm PVC insulated unsheathed,stranded copper conductor cable single core 1100V grade with in and including rigid PVC conduit 20mm or higher size medium grade in concealed manner with all PVC conduit accessories with provision of CI/pressed steel terminal switch box & white bakelite plastic laminated top sheet cover fixing with brass screws and cup washers and 1.5Sqmm PVC insulated unsheathed stranded copper single core 1100V grade as earth wire & wire connected with the main earth point all as specified & directed.
S&F for switch piano 230 volts AC flush type, single pole, one way 6 Amps ISI Marked complete all as specified and directed. Make : Anchor/ Cona / Havells
S&F for switch piano 230 volts AC flush type single pole, one way 16 Amps ISI Marked complete all as specified and directed. Make : Anchor/ Cona / Havells
S&F for socket outlet 2/ 3 pin 230 volts 5/6 Amps flush type complete all as specified and directed. Make : Anchor/ Cona / Havells
S&F for socket outlet 5/6 pin 15 Amps flush type 230V AC complete all as specified and directed. Make : Anchor/ Cona / Havells
Supply & fixing for lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting ISI marked complete all as specified & directed Make : Anchor/ Cona / Havells
S&F for ceiling rose 3 terminal / PVC/ polycarbonate, isolated body ISI marked all as specified and directed Make : Anchor/ Cona / Havells
S&F for Fan electronic dimmers,450W,250V flush type on exiting phenolic laminated sheet all as specified and directed. Make : Anchor/ Cona / Havells
S&F for MCB DB SPN 4 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and as directed. . Make:- Legrand,Schneider,Siemens,L&T,
S&F for MCB DB SPN 8 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and as directed. . Make:- Legrand,Schneider,Siemens,L&T,
Supply & fixing for MCB , SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed. Make:- Legrand,Schneider,Siemens,L&T,
Supply & fixing for MCB, SPN, AC, 240 volts of 32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed. Make:- Legrand,Schneider,Siemens,L&T,
S&F for LED tube light batten 20 Watt, 4ft, Polycarbonate housing, translucent diffuser, With LED Light Source, 2200 Lumens, natural White, Surge Protection range- 2KV, Voltage Protection range – 120 -280VAC, 2 years warranty , System efficacy not less than 110Lm/Watt for the fitting, power factor >0.95, total harmonic distortation<20%, Color rendering index >80, Coefficient Colour Temperature – 6500K, Fixed on site with all accessories all as specified & directed. Cat No: SZSLBMX020 of shakti Cat No,C&S LTTB4F20WLEDof C&S LM79 and LM 80 Reports to be produced. BIS Certification must.
S&F for sub main wiring with two single core PVC insulated,unsheathed, stranded copper conductor cable 4 Sqmm with 4 Sqmm FRLSH PVC insulated, unsheathed, stranded copper conductor cable as earth wire in existing surface/recessed steel/PVC conduit and earth wire connected to common earth dolly all as specified & directed. Note: Three run of 4 sqmm cable shall be measured as one unit Make:- Havells,KEI,Universal,RPG,Gloster
Disconnecting and taking out old unserviceable PVC cable supply and laying 1100 volts grade heavy duty cable PVC insulated aluminium conductor,served with inner sheathingof PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1meter apart including4mm suspension wire,one twin core 16 sqmm cable flat or circular all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level connected by 4 mm GI wire as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM and charcoal, dust and common salt all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
PIONEER REFRIGERATION AND ELECTRICALS
S.M. KAZIM
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .