| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC H NO 963 10 STREET NO 5 DEEP NAGAR CIVIL LINES LUDHIANA 141001 PUNJAB | LUDHIANA | LUDHIANA | PUNJAB | 141001 | L1 | Accepted-AOC lowest | |
| 2 | L2₹15.9 L+₹98,021.79 (6.56%)Rejected-Finance C O CHOUDHARY 45 PEER BABA TARUSHAW ROAD HALWARA A D DISTT LUDHIANA PIN CODE 141106 PUNJAB | LUDHIANA | LUDHIANA | PUNJAB | 141106 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹16.8 L+₹1.8 L (12.1%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹16.9 L+₹2.0 L (13.2%)Rejected-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L4 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹37,280
Closing Date
27 Nov 2020, 6:00 pmClosed
GE Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge
Special repair to Bldg No P-36/4 at CG Complex and certain sanctioned work at Dholewal under GE Ludhiana
2020_MES_378529_1
GE/LDH-36/2020-21
Open Tender
Civil Works
Item Rate
180 days
CG Complex and Dholewal under GE Ludhiana
Refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹37,280
Yes
5 Jan 2021
18 Sept 2020
28 Nov 2020
18 Sept 2020
27 Nov 2020
25 Sept 2020
18 Sept 2020 - 24 Sept 2020
Amount
Sch 'A' sec-I
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness ( below or above ground level) complete all as specified and directed by Engineer-in-Charge
Demolition of reinforcement cement concrete as in Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work (reinforcement cut as reqd to facilitate demolition) complete all as specified and directed by Engineer-in-Charge
M&L for Reinforced Cement Concrete type B1 1:2:4 (nominal mix ) (using 20 mm graded stone aggregate) in Chajjas etc. complete all as specified and directed by Engineer-in-Charge
Use and waste rough finished flat Form work to sides and soffits of floor or roof beams, lintels, cantilevers, shelves including supports etc. complete all as specified and directed by Engineer-in-Charge
Use and waste rough finished Form work to edges of concrete floor and roofs and similar work exceeding 5 Cm but not exceeding 10 Cm wide. complete all as specified and directed by Engineer-in-Charge
M&L for Mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality complete all as specified and directed by Engineer-in-Charge
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing, serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge
M&L Vitrified ceramic dark shade coloured tiles 10mm thick square/rectungular polished area of each tile not exceeding o.36 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15 mm thick screed bed of cm 1:6 complete all as specified and directed by Engineer-in-Charge
Ditto- as per item No 8 above but as in skirting over rendering 10mm thick in cement mortar 1:4.
M&L Non skid cerermic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc. 0.11 sqm but n.exc. 0.18 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement with pigment to match over 15mm thick screed bed in cement mortar (1:6).complete all as specified and directed by Engineer-in-Charge
Ditto- as per item No 10 above but as in skirting over rendering 10mm thick in cement mortar 1:4.complete all as specified and directed by Engineer-in-Charge
M&L glazed ceramic coloured/ printed tiles 450mm x 300mm x 6 to 7mm thick on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick bedding layer in cement mortar (1:3) including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L 25mm thick Cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggr.as in sub flooring rough finished surface complete all as specified and directed by Engineer-in-Charge
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed by Engineer-in-Charge
M&L granite slab (of any type) 20mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in 15mm thick screed bed of cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite.complete all as specified and directed by Engineer-in-Charge
M & L for machine cut kota stone slab 18 to 20 mm thick as in flooring / stair case landing, laid over & incl. 15mm thick cement screed base in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing complete all as specified and directed by Engineer-in-Charge
Ditto as item No 12 above but in one piece as in treads of stair complete all as specified and directed by Engineer-in-Charge
M & L for machine cut kota stone slab 16 to 20mm thick as in skirting/steps of stair case laid over & incl.10mm thick cement screed base in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing complete all as specified and directed by Engineer-in-Charge
Demolition of brickwork built in cement or cement lime mortar incl all quoins, arches, pillars, etc but excl ashlar facings, dressed stonework and precast concrete articles.complete all as specified and directed by Engineer-in-Charge
M&L, brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in cm 1:6 complete all as specified and directed by Engineer-in-Charge
-ditto- as above item but except bricks complete all as specified and directed by Engineer-in-Charge
S & F steel window 1.25 mm thick box type (primer coated) ERW hollow P section of size 60mmx25mm single rebated comprises gauged skeleton shutter ERW sec 50mmx20mm and 1mm thick with two openable leaf consisting two Nos sash bars of T-section 20mmx3mm complete welded to frame with one verticle mulion of ERW box type T-section of size 60mmx25mm and 1.25mm thick incl cutting holes and making good dismantled portion PCC (1:2:4) type B-1 four Nos for each window) including following fittings welded to frame shutter: - (a) Hold fast, 150mm long of 12mmx3mm made to shape-04 Nos per window. (b) Handle of z section 20mmx25mm, 100mm long 01 Nos per leaf (c) MS tower bolt 150mm long-2 Nos per leaf (d) z section 20mmx25mm, 100mm long stopper - 01 No per leaf (f) MS pintal hinges of size 75mmx12mm- 2 Nos per leaf (g) Fabrication & fixing arrangement as per Drg No CEJZ/TD-06/07. Note: wire mesh and painting shall be measured & paid separately under appropriate item.complete all as specified and directed by Engineer-in-Charge
All as per item No 22 here in before but window with glazed shutters . Note Glass and painted shall be measured and paid separately under appropriate item.
S&F mild steel framed work such as guard bars/grills,grating etc with end of bars shouldered and/or riveted or forged into spikes and similar works including one shop coat of zinc chromate primer complete all as specified and directed by Engineer-in-Charge
S&F galvanized mild steel wire cloth 0.56 mm nominal dia and average width of aperture 1.18 mm and fixed with tined tacks.complete all as specified and directed by Engineer-in-Charge
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n. exc 0.5 sqm each panes complete all as specified and directed by Engineer-in-Charge
Taking down chowkats or frames(without taking off shutters from the frame) area n.exc 1.5 Sqm each.complete all as specified and directed by Engineer-in-Charge
Taking down chowkats or frames exc 1.5 Sqm but n.exc 4.0 Sqm with shutters (without taking off shutters from the frame).complete all as specified and directed by Engineer-in-Charge
Taking down shutters of any desciption area exc 1.0 Sqm but n.exc 2.0 Sqm each and refixing in the same opening after easing and minor adjustment.complete all as specified and directed by Engineer-in-Charge
S&F pressed steel frames,size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete all as specified and directed by Engineer-in-Charge
Ditto as above but size 125 X 60mm complete all as specified and directed by Engineer-in-Charge
M&L, Providing cement concrete type C-0 1:3:6 (12.5 mm graded agg) as for pressed steel chowkhats.complete all as specified and directed by Engineer-in-Charge
S&F 35mm thick factory made 2nd class hard wood plain, framed, panelled shutters (two panels) with lock rail and panelsof 9mm thick BWP commercial; ply or 12mm thick veneered p article boards on both sides. The size of rail and style as per IS-1003 (part-I) kiln seasoned and chemicaly pressure treated.complete all as specified and directed by Engineer-in-Charge
M&L for 35mm thick IInd class Hard wood glazed and skeleton shutters open rebated and prepared to receive glass, gauge etc.(without sash bars) edges of framing plain, chemfered fitted with cut and mitred beads for securing glass, etc. sizes of shutters as specified in SSR Part I section 8, clause 8.24 (a) supplied and fitted to chowkat . complete all as specified and directed by Engineer-in-Charge
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain glover PVC sheet reinforced with MS square tube in opening as per specification and drawing.complete all as specified and directed by Engineer-in-Charge
S&F factory made soilid panel PVC Door shutter 30mm thick (Stype) consisting of frame made out MS frame shall be covered with heat moulded plain coloured PVC 'C' channel having PVC sheet stripof 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail, & bottom rail; Panneling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing.complete all as specified and directed by Engineer-in-Charge
S&F mild steel 300mm helical door spring , ordinary rat tail rod patteren including roller and roller plate complete all as specified and directed by Engineer-in-Charge
S&F 150mm aluminium anodised barrel tower bolts of extruded section and fixed.complete all as specified and directed by Engineer-in-Charge
S&F 250mm aluminium alloy anodised sliding bolts with hasp, staple and fixing clips of sheet, cast or extruded section fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed.complete all as specified and directed by Engineer-in-Charge
S&F 125mm aluminium handles, cast type ,anodised and pattern/design as approved.complete all as specified and directed by Engineer-in-Charge
Taking up or down steel tubing 15mm bore and connections, including cleaning for refixing or removal to store.complete all as specified and directed by Engineer-in-Charge
-ditto- all as per above item but 20mm bore.complete all as specified and directed by Engineer-in-Charge
S&F 15mm GI tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors.complete all as specified and directed by Engineer-in-Charge
-ditto as above but 20mm bore.complete all as specified and directed by Engineer-in-Charge
Refixing old steel tubing and connections in new or old postion (wall, ceiling , floors ,etc) 15mm bore.complete all as specified and directed by Engineer-in-Charge
-ditto all as per above item but 20mm bore.complete all as specified and directed by Engineer-in-Charge
S&F in repairs ball brass valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore pipe.complete all as specified and directed by Engineer-in-Charge
S&F stop valves 20mm, cast copper alloy, screwed down, high pressure with crutch or butterfly handle etc complete fixed in repairs.
S&F in repairs Rotational moulded polythylene water strarge tanks 500 ltr (Cylinderical vertical with closed top ) hoisted and fiexed in position all as per specified in SSR Pt-1.complete all as specified and directed by Engineer-in-Charge
S&F in repairs Rotational moulded polythylene water strarge tanks 1000 ltr (Cylinderical vertical with closed top ) hoisted and fiexed in position all as per specified in SSR Pt-1.complete all as specified and directed by Engineer-in-Charge
S&F in repairs vitreous china wash down water closet pedestal pattern pan white with trap including connection to existing out joint pipe, flushing pipe or Cistern, antisyphonage pipe, including making, etc complete including making goood to floor etc complete all as specified and as directed (Make : Hinduware/Cera or equvalent approved by Engineerin-Charge.
S&F in repair plastic water closet seat cover of White colour closed pattern with flat bottom and cover with mild steel chromium plated hinging device etc complete all as specified and directed by Engineer-in-Charge
S&F in repair vitreous china washbasin, white, flat back, size 550 x 400mm, including brackets & incl 32mm bore waste fitting brass, CP for glazed ware basinetc with long screwed shanks and fly-nuts flange end bedded in red lead cement and other end complete all as specified (without pedestal).
S&F in repair vitreous china washbasin, white, flat back, size 550 x 400mm, including brackets & incl 32mm bore waste fitting brass, CP for glazed ware basinetc with long screwed shanks and fly-nuts flange end bedded in red lead cement and other end fixed including pedastal for washbasin complete all as specified.
S&F viterous china squartting pan orrisa pattern , size 580x 440mm white, interged foot rest including connection to trap and to flush pipe, anti syphonic pipe etc complete making good to floor
M&L 75mm dia cast iron floor trap with grating incl jointing to waste pipe with run lead joint and embedde in cement concrete (1:2:4) type B0-1 using graded stoe agg complete all as specified and directed by Engineer-in-Charge
S&F cast copper alloy chromium plated fancy type single lever basin mixer .(Make: PRAYAG or Equivalent) complete all as specified and directed by Engineer-in-Charge
S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge (Make: PRAYAG or Equivalent)
S&F Bib taps chromium plated fancy type, cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed in repair 15mm bore complete all as specified and directed by Engineer-in-Charge (Make: PRAYAG or Equivalent)
S&F C P health faucet suitable for Europian western commode (EWC) including PVC connection 15mm size with PTMT nuts and washer, of length 900mm. (Make: prayag or equivalent)
S&F Soap dish fixed to walls with chromium plated brass screws.complete all as specified and directed by Engineer-in-Charge (Make- CERA or equivalent)
S&F stop valves/angle valve 15mm, chromium plated,fancy type, complete fixed in repairs. (Make- Jaco or equivalent)
S&F PVC connections 15mm size with PTMT nuts of legth 600mm.
S&F toilet paper holder of CP fixed to walls with chromium plated brass screws.(Make- PRAYAG or equivalent)
S&F in repairs brass chromium plated tubular towel rail, 20mm dia D-type, 60cm long between flange.
S&F in repairs brass chromium plated tubular towel rack. (Make- PRAYAG or equivalent)
S&F Brass CP mixer/Mixing valve on walls for mixing hot & cold water screwed down for iron pipe , including two-in-one joints to steel pipes or unions and plugging and screwing to walls and fixed 15mm bore fixed in repairs comlete all as specified. (Make : Prayag and equvalent)
S&F in repair PVC bathroom cabinet mirror size 350mm x 450mm complate all as specified and directed. (Make : Prayag and equvalent)
S&F chlorium plated shower roses with or without swivel join ts 125mm size incl fixing to steel pipe in repairs (Make-CERA or equivalent)
S&F 10 ltr capacity PVC valveless, syphonic action type flushing cistern,low level, white, with inlet, ball valve, float and handle incl brackets fixed in repairs.
M&L two coat of white wash to old surfaces of walls after preparation complete all as specified and directed by Engineer-in-Charge
Ditto as above but on ceiling surfaces complete all as specified and directed by Engineer-in-Charge
S & F 25 mm thick flush shutter solid core construction, with block board core and plywood face panels,commercials type on both sides covered with decorative face venner with lipping/frame to math complete all as specified and directed by Engineer-in-Charge
S&F in repairs stainless steel sink with drainage board made out of 1.00mm thick sheet for kitchen or laboratory, with plug, waste pipe, washers incl. cantiliver cast iron brackets, connecting union etc overall size 915mm X 460mm with bowl size 410mm X 330mm X 160mm.
S&F in repairs pre-laminated (both sides) particle board 18/19mm thick with decorative choice laminations, interior grade, fixed with screws to timber frame work.
S & F Aluminium handle cast type anodised of size 75mm completed all as specified and directed.
Taking down curtain rod along with wooden pallmate laid on wall complete all as specified and directed by Engineer-in-Charge.
S&F in repair curtain rod made out of 25mm dia(outer dia )pipe having thickness 0.63mm , PVC coated and colour/pattern, over all dia 28 to 29 mm complete all as specified and directed, Make :- Aerolux/MEC.
S&F plastic finial of 28 to 29mm bore, decorated type, of any colour/pattern, best quality to suit the curtain rod and fixed at the end of curtain rod with suitable adhesive complete all as specified and directed, Make:- Aerolux/MEC or VISTA
S&F mild steel prepainted bracket to hold the curtain rod and fixed to wall(Concrete/brick masonry) with the help of 2 Nos 50mm long steel screws and rawl plug included drilling with electric drill and making good the disturbed surfaces complete all as specified and directed by Engineer-in-Charge
Demolition and breaking up drain pipes/pipe fixed to wall (PVC, Salt glazed ware, AC or re-inforced concrete) set in cement mortar bore of pipe 100mm complete all as specified and directed by Engineer-in-Charge
S&F 110mm bore UPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/floor complete all as specified and directed by Engineer-in-Charge
S&F 75mm bore UPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/floor complete all as specified and directed by Engineer-in-Charge
S&F PVC (SWR) bend any radius 110mm bore complete all as specified and directed by Engineer-in-Charge
S&F PVC (SWR) 'P' trap radius 110/110mm bore complete all as specified and directed by Engineer-in-Charge
M&L Endura chequered cement concrete tiles 30cmx 30cmx 10mm thick,set, jointed & pointed in neat cement slurry in floors with grey cement and pigments over & including 20mm thick screed in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge
Demolition for cement conc exc 15cm thickness but above ground floor as sunken floor .complete all as specified and directed by Engineer-in-Charge
M&L for cement concrete type E - 2, 1:5:10 (using 40 mm graded stone aggregate) as in sunken flooring , mass cocncreteing etc .complete all as specified and directed by Engineer-in-Charge
M&L for applying two coats of SHALIMAR SUPERCRETE/NITOBOND water proofing coating on the entire surface of sunken portion complete all as specified and directed by Engineer-in-Charge
M&L for 15mm thick cement screed in CM 1:3 admixed with integrd water proofing compound FOSROC’s complast X 421 IC @ 130ml per bag of cement incl a bonding coat of FOSROC”s Nito bond AR cement slurry/STP NO 1 liquid @ 200ml per bag of complete all as specified and directed by Engineer-in-Charge
M&L, PCC (1;2:4) type B-1 using 20mm graded stone agregete as in sides of rounded or chamfered on edges of sunken floor complete all as specified and directed by Engineer-in-Charge
S&F32mm dia G I pipe 450mm long beveled cut at both ends by making hole in walls sunken portion approx above the R C C slab and ceiling finished the hole with cement plaster 1:2 to match with existing surfaces complete all as specified and directed by Engineer-in-Charge
M&L, Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required area not exc 150cm.complete all as specified and directed by Engineer-in-Charge
M&L for stainless steel plate rack of superior quality size 36" x 24" with not less than 8 kg complete all as specified and directed by Engineer-in-Charge
S&F steel ventilators fixed type with glazing bar complete all as specified and directed by Engineer-in-Charge
S&F Floor doors stoppers of aluminium alloy body and tenque anodisede with hard drawn steel spring fixed in floor 150mm long.complete all as specified and directed by Engineer-in-Charge
Dismantling brick tiles or terracing tiles sinlge layer on roofs.complete all as specified and directed by Engineer-in-Charge
Demolition of mud in roofs any thickness including plastering and leeping(whether full thickness removed or only a part there of) complete all as specified and directed by Engineer-in-Charge
M&L for wire brushing neat cement slurry with 3kg of cement per sq m at top and bottom of base coat and cleaning top surface complete all as specified and directed by Engineer-in-Charge
M &L for PCC 1:2:4 type B-1 as roof padding concrete to bring the extg slab in slope of 1:40. complete all as specified and directed by Engineer-in-Charge
M&L for Priming surfaces and applying normal treatment (for moderate conditions) using bitumen primer @ .30 Kg/Sqm applied hot complete all as specified and directed by Engineer-in-Charge
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2kg per sq.m incl cleaning surfaces.complete all as specified and directed by Engineer-in-Charge
M&L for fixing APP based polymeric membrane minimum weighing 3kg/sqm and min 3mm thick reinforced with polyster non woven fabric (wt not less than 150gms/sqm) land on primered surface by torced application.complete all as specified and directed by Engineer-in-Charge
M&L 40mm thick brick tiles laid on 15mm thick cement mortar 1:6 and joints grouted flush in cement mortar 1:3 mixed with 5% 0f crude oil by weight of cement complete all as specified and directed by Engineer-in-Charge
-ditto- as above but except tiles after clening and removing old mortar from bricks complete all as specified and directed by Engineer-in-Charge
M&L flush pointing to brick laid flat or brick tiles in paving cement mortar in 1:3.complete all as specified and directed by Engineer-in-Charge
M&L, PCC 1:2:4 type B1 (using 20mm graded stone aggregate) in roof kerbs or mud stops, benching rounded or chamfered on edges complete all as specified and directed by Engineer-in-Charge
Taking down cement plaster on brick or stone walls etc including raking out joints hacking for key scrubbing down with water etc.complete all as specified and directed by Engineer-in-Charge
M&L, 12mm thick plastering on fair faces of bricks or conc surfaces finished even and smooth w/o using extra cement in cm1:6.complete all as specified and directed by Engineer-in-Charge
M&L, 5mm thick plastering on fair faces of conc surfaces finished even and smooth w/o using extra cement in cm1:3 on ceiling .complete all as specified and directed by Engineer-in-Charge
M&L 15mm thick plastering on fair faces of bricks or concrete surfaces finished even and smooth w/o using extra cement in cm1:4.complete all as specified and directed by Engineer-in-Charge
M&L Preparing of new surface of plaster and applying three coats of white wash on ceiling.complete all as specified and directed by Engineer-in-Charge
M&L for Preparing of new plastered surface and applying two coats cement base paints on walls.complete all as specified and directed by Engineer-in-Charge
M&L for Preparation of new surface of wall and applying two coat of oil emulsion white or printed on walls over 3mm thick Birla wall care putty filling on plastering surface .complete all as specified and directed by Engineer-in-Charge
M&L Preparation of old surfaces of wallsand applying one coat of cement base paint complete all as specified and directed by Engineer-in-Charge
M&L for complete removal of existing treatment and applying two coats of oil bound emulsion white or printed on walls. over 3mm thick Birla wall care putty including preparation of surfaces of wall complete all as specified and directed by Engineer-in-Charge
M&L for preparation of old painted wooden surfaces of any description not other wise described over 10cm width or girth and applying one coat (finishing coat) of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge
M&L, Preparation of new surfaces of wood surface of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamelled paint over one coat of pink primer.complete all as specified and directed by Engineer-in-Charge
M&L for preparation of old painted Steel surfaces of any description not other wise described over 10cm width or girth and applying one coat (finishing coat) of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge
-do- all as per above but two coats of synthetic enamelled paint of new surface of steel.
M&L for repairing RCC projection chajjas, roof, facia etc. by necessary preparation, scraping, cutting, chiseling derusting and cleaning exposed reinforcement surfaces of damaged, loose RCC surfaces with cement concrete (1:1.5:3) using 12.5mm graded crushed stone aggregates and reinforcement with welded mesh of weight exc 2Kg per Sqm but n.exc 3Kg/Sqm (if required) with or without facia and finished with cement morte 1:3 using coarse sand and work in patches area n.exc 5 Sqm and thickness RCC member n.exc 70mm incl necessary formwork and applying two coats of finishes to match with the existing surfaces at any height complete. (note: wlded mesh to be paid separately)
Resecuring or easing and adjustment without taking down the shutters of any description exc 1 Sq.m and n.exc 2 Sq.m each complete all as specified and as directed by the Engineer-in-Charge.
Resecuring or easing and adjustment without taking down the shutters of any description exc 2 Sq.m each complete all as specified and as directed by the Engineer-in-Charge.
M&L, Framed work as in doors or gate,coolers stand of angle or others section etc confirming to Fe 410-s .complete all as specified and directed by Engineer-in-Charge
S&F chromium plated sink mixture(single liver) of size (254mmx203.2mmx203.2mm) incl fixing to steel pipe in repairs (Make-CERA CAT Part No-F1005501)
S&F chromium plated two way bib cock (single knob) of size (254mmx203.2mmx203.2mm) incl fixing to steel pipe in repairs (Make-CERA CAT Part No-F1015163)
S&F Butt hinges 100mm long extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed , type B-21 complete all as specified and directed by Engineer-in-Charge
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,watering, and removing surplus soil to a distance n exc 50 m and making good surface watering, and removing surplus soil to a distance n exc 50 m and making good surface. complete all as specified and directed by Engineer-in-Charge
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation , filling mass concrete complete all as specified and directed by Engineer-in-Charge
S&F, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-Charge
S&F, Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engineer-in-Charge
S&F, Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 5 cm but n exc 10cm long of 5 to 10 mm diameter of neck complete all as specified and directed by Engineer-in-Charge
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil .
Excavating in trenches, n exc1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil
M&L for RCC (1:1.5:3) using 20mm graded stone aggregate as in slab supported on wall complete all as specified and directed by Engineer-in-Charge
M&L for Mild steel TMT bars 6mm to 8mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality complete all as specified and directed by Engineer-in-Charge
Use and waste of formwork to soffits and sides of lintels for finished surfaces of concrete flat complete all as specified and directed by Engineer-in-Charge
M&L for TMT bars 5mm and over upto and including 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality complete all as specified and directed by Engineer-in-Charge
M&L 15mm thick rendering/ screed on terrace or concrete surface in cement mortar 1:4 finished even and fair w/o using extra cement in cm1:6.complete all as specified and directed by Engineer-in-Charge
Supply only integral water proofing compound.
S&F steel ventilator with top hung shutter including hinges steel peg stay complete all as specified and directed by Engineer-in-Charge
S&F 3mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane.
S&F wire netting of galvanised steel wire 0.91mm dia and 20mm mesh size fixed with tinned tacks or GI wire to steel members.
S&F 250mm aluminium alloy anodised sliding bolts with hasp, staple and fixing clips of sheet, cast or extruded section fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed.complete all as specified and directed by Engineer-in-Charge
M&L Non skid cerermic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc. 0.06 sqm but n.exc. 0.11 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement with pigment to match over 15mm thick screed bed in cement mortar (1:4).complete all as specified and directed by Engineer-in-Charge
M&L glazed ceramic coloured/ printed tiles 300mm x 200mm x 6 to 7mm thick on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick bedding layer in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface .
M&L for 50mm thick PCC 1:2:4 type B-1 using 20mm crushed stone aggregate as in plinth protection and like finished even and smooth without using extra cement .
M&L for damp proof course to horizontal or vertical surfaces including necessary formwork in cement concrete 1:2:4 type B-0 .
S&F vitreous china ware wash down water closet pan (pedestal pattern) white and plastic seat and cover with MS CP hinges complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china wash basin with vitreous china pedestal , white , flat back , size 550x400mm , fixed on existing brackets incl 32mm bore CP waste coupling
S&F 10 ltr capacity PVC valveless, syphonic action type flushing cistern,low level, white, with inlet, ball valve, float and handle incl brackets.
S&F PVC connections 15mm size with PTMT nuts of legth 450mm.
S&F Bib taps chromium plated fancy type, cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule 15mm bore complete all as specified and directed by Engineer-in-Charge
S&F Rotational moulded polye- thylene water storage tanks of 500 ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
S&F 20mm bore tube medium grade , galvanised with all fitting and fixed complete to walls and ceilings or laid in floors.
S&F 15mm bore tube medium grade , galvanised with all fitting and fixed complete to walls and ceilings or laid in floors.
S&F stop valves 15mm, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed .
S&F stop valves 15mm(Concealed type) cast copper alloy, screwed down, high pressure with long shank and cup etc.
S&F stop valves 20mm, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed .
S&F 20mm bore brass ball valves , high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed.
S&F 100mm bore Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors.
S&F 75mm bore Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors.
S&F 75mm bore cast iron cowls .
S&F CI P-traps for water closet of 100mm bore .
S&F CI floor trap 75mm bore and jointing to waste pipe in cement concrete 1:2:4 type B-1.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removal of surplus spoil to a distance exc. 50m and n exc 100 m and depositing where directed at a level n exc. 1.5 m above the starting point in soil .
M&L, brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in cm 1:4 complete all as specified and directed by Engineer-in-Charge
M&L for precast RCC 1:2:4 type B-1 using 20mm graded stone agg as in cover slab and like set in cement mortar 1:4 complete incl necessary formwork.
M&L cement Concrete 1:4:8 type D-2 using 40mm graded stone agg as in bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested.
M&L 150mm internal dia salt glazed stone ware drain pipe laid in trenches and jointed complete all as specified and directed by Engineer-in-Charge
M&L for 75mm thick PCC 1:2:4 type B-2 using 40mm thick graded stone aggregate as in floors finished even and fair complete all as specified and directed by Engineer-in-Charge
Sch 'A' sec-II
Taking down carefully point wiring copper/ aluminium (light, fan, socket, power) complete including switches, ceiling roses , pendants, regulators , sockets etc and removing materials to store and making good the disturbed surfaces of walls, floors etc Complete all as specified & directed by Engineer in Charge.
Taking down service /sub main wire of any size fixed in any position , complete all as specified and directed by Engineer in charge.
M & L for point wiring with PVC (FRLS) unsheathed, fire resistance, stranded copper conductor of size 1.5 sqmm (nominal cross sectional area ) single core cable in and including concealed (surface only on roof & colomns) wiring incl PVC conduit medium grade, ISI marked, 20 mm or higher dia complete with all accessories/fittings and sunkan MS boxes of thickness not less than 1.2 mm covered with 3 mm thick plastic laminated hard glassy surface sheet cover concealed in wall with screws & washers including unsheathed single core PVC (FRLS) insulated cable green in colour 1.5 sqmm stranded copper conductor as earth wire and connecting to earth dolly, complete all as specified & directed for the following.
One light point controlled by one switch 5 Amps one way.
One ceiling fan/Ex fan point controlled by one switch 5 Amps, one way
One call bell point controlled by one bell push
One 3/5 pin 5 Amps socket outlet on independent board
One 3 pin 5 Amps socket outlet on same board
M & L for point wiring with PVC (FRLS) unsheathed, fire resistance, stranded copper conductor of size 2.5 sqmm (nominal cross sectional area ) single core cable in and including rigid non metalic PVC conduit 20 mm dia or higher size "medium " grade ISI marked concealed (surface only on roof & colomns) complete with all accessories/fittings and MS box thickness not less than 1.2 mm covered with 3 mm thick plastic laminated hard glassy surface sheet cover concealed in wall with screws & washers including unsheathed single core PVC (FRLS) insulated cable green in colour 2.5 sqmm stranded copper conductor as earth wire and connecting to earth dolly, for one three /six pin 15/16 amps power socket controlled by one 15/16 amps switch complete all as specified & directed by Engineer in Charge.
Supply and fix LED tube light fittings 1200 mm, 20W, 240V, 50Hz,rated input current- 0.070-0.110, rated input watt 20, oprating voltage range- 140-270, P.F- not less then 0.95, surge protection upto- 4Kv, IP20, THD shell be less then 10%, CCT- (k0)- 6500ANSI, higher energy saving decorative ultra slim square profile LED lighting fixture with extruded polycarbonate enviromental friendly, energy efficient complete all as specified and directed. Make:- OSRAM/Crompton/Havells/Bajaj/Philips
Supply and fix LED tube light fittings 600 mm, 10W, 240V, 50Hz,rated input current- 0.070-0.110, rated input watt 20, oprating voltage range- 140-270, P.F- not less then 0.95, surge protection upto- 4Kv, IP20, THD shell be less then 10%, CCT- (k0)- 6500ANSI, higher energy saving decorative ultra slim square profile LED lighting fixture with extruded polycarbonate enviromental friendly, energy efficient complete all as specified and directed. Make:- OSRAM/Crompton/Havells/Bajaj/Philips
Supply and fixing 15 Watt LED surface mounted panel injection model in thermally conductive engineered plastic - FR V0 grade housing, diffuser with optically efficient material and connection from ceiling rose to connector complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr in Charge. Make: OSRAM/Crompton/Havells/Bajaj/Philips
Supply and fix LED Bulk Head fitting 10 watt with pressure die cast aluminium housing for multiple application IP 65 protected complete all as specified and directed by Engr in Charge. Make: OSRAM/Crompton/Havells/Bajaj/Philips
S&F Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed
S&F Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed
S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed
S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed
Supply and fixing ceiling rose surface bakelite 65x 50mm 2 to 3 terminal, polycarbonate /pvc/ isolated body complete all as specified and directed by Engr in Charge
Supply and fix Electronic Bell 230 Volts single pole Ding dong type complete all as specified and directed by Engr in Charge
Supply and fix bell push 230 Volts complete all as specified and directed by Engr in Charge
Supply and fixing rotary stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc.as reqd complete all as specified and directed by Engr in Charge
S&F Modular White cover plate with frame,6 module complete all as specified and as directed
S&F Modular White cover plate with frame,4 module complete all as specified and as directed
S&F Modular White cover plate with frame,3 module complete all as specified and as directed
S&F Modular White cover plate with frame,2 module complete all as specified and as directed
S&F Modular Metal flush box 6 module complete all as specified and as directed
S&F Modular Metal flush box 4 module complete all as specified and as directed
S&F Modular Metal flush box 3 module complete all as specified and as directed
S&F Modular Metal flush box 2 module complete all as specified and as directed
M & L for sub main wiring with two run of 4 Sqmm (nominal cross sectional area ) of single core unsheathed PVC (FRLS) insulated cables 1100 Volts grade multi stranded copper conductor drawn through & including non metallic rigid PVC conduit of size 19/20 mm or higher dia with & including necessary conduit accessories concealed/surface only on roof & colomn) type including one run of 4 Sqmm stranded copper conductor PVC (FRLS) insulated cable as earth wire connected to common earth dolly complete all as specified & directed by Engineer-In-charge.
M & L for sub main wiring with two run of 6 Sqmm (nominal cross sectional area ) of single core unsheathed PVC (FRLS) insulated cables 1100 Volts grade multi stranded copper conductor drawn through & including non metallic rigid PVC conduit of size 19/20 mm or higher dia with & including necessary conduit accessories concealed/surface only on roof & colomn) type including one run of 6 Sqmm stranded copper conductor PVC (FRLS) insulated cable as earth wire connected to common earth dolly complete all as specified & directed by Engineer-In-charge.
Taking down ceiling fan, sealing cable end, dismantiling blades and removing fan and blades to store complete all as specified and directed by Engr in Charge
M & L for cleaning thoroughly and spray painting of ceiling fans with super enameled paint (white) etc complete all as specified and directed by Engr in Charge
M & L for Re-fixing ceiling fan at the existing site / rooms and connected with 23/0.0076 three core PVC flexible cable from ceiling rose to fan etc complete all as specified and directed by Engr in Charge
S& F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, replastring to match with existing surface etc complete all as specified & directed by Engineer-in-charge.
Supply and fixing factory made sheet metal enclosures SPN 12 way double door 240 v with 200 Amps rated bus bar for DB,s suitable for having MCB / Isolator flush with wall complete all as specified and directed by Engr in Charge
S&F MCB, single pole 240 Volts 5 to 30 Amps complete all as specified & directed by Engineer-In-charge.
S&F Single pole and neutral 240 Volts 40 Amps complete all as specified & directed by Engineer-In-charge.
Earthing complete with galvanised steel earth plate electrode 60cm X 60 cm X 6.3 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level with the top edge of electrode not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4mm dia means of bolts, nuts,check nuts and washers of galvanised iron and GI lead protected with protection pipe of GI light grade 15mm dia upto 3mtr above ground level along poles fixed with two clamps of 25mm 3mm flat iron and connected to running earth wire at top of poles and watering pipe 20mm bore of GI medium grade all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing test point all as specified and direct and testing on completion including PCC 1:3:6 ) C-I cover and frame excavation and earth work etc complete all as specified in elect plate No 3 of SSR Part -I 2009 Note :- PCC Chamber shall be constructed at least 1.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner complete all as specified and directed by Engr in Charge
Supply and fixing in replacement of XLPE insulated screened PVC bedded galvanised steel strip or wire armoured UG heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area of 25 sqmm 4 core size laid in trenches under floor/roads/hard standing along poles etc complete all as specified and directed by Engr in Charge (Excavation and earth work, sand cushioning ,brick protection & GI pipe shall be measured and paid for separately).
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exc. 1.5 mtr deep for laying of cables and getting out soft/loose soil complete complete all as specified and directed by Engr in Charge
M & L filling dry and clean sand in trenches for cable 8 cm deep below and 15 cm above for cable cushioning complete all as specified and directed by Engr in Charge Note :- thickness of 18cm after punning shall be considered for payment.
M & L for sub class 'B' brick of size 230x115x75mm laid flat work length equal to width of brick on sand for protection of under ground cable complete all as specified and directed by Engr in Charge
Returning filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in trenches complete all as specified and directed by Engr in Charge
Removal of surplus soil obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr in Charge
Supply and fix TPN MCB DB 4 ways 415 Volt, Double door type all as specified and as directed by Engr-in-charge Make:- Havells/Schneider/Indo-Asian/Legrand/ABB
S & F MCB TPN 63 Amps, 16 KA, 50Hz ,415 Volts complete all as specified and as directed by Engr-in-charge Make:- Havells/Schneider/Indo-Asian/Legrand/ABB
M & L for GI pipe 40 mm dia Light grade fixing to wall or laying in floors for protection of cable complete all as specified and directed.
PREM CONSTRUCTION COMPANY
JAY ANN CONSTRUCTION COMPANY
PK ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .