Loading…
Loading…
Tender Value
₹1.5 Cr
EMD Value
₹1.5 L
Closing Date
18 May 2026, 5:00 pmClosed
Superintending Engineer (CG), GIDC, Bharuch.
Design, Engineering, Supply, Installation, Testing and commissioning of Non Clog type Centrifugal Pump Set for effluent with accessories and allied Electro-Mechanical and Instrumentation and SCADA work at MRF Company Pumping Station at Dahej III.
300952
E-Tender Notice No. 01 of 2026-27 Sr. No. 14
Open
Electrical Works
Works
Bharuch
2 documents required · 2 mandatory
₹4,248
Executive Engineer, GIDC, Bharuch
₹1.5 L
4 May 2026
4 May 2026
4 May 2026
18 May 2026
4 May 2026
Name of Work: Design, Engineering, Supply, Installation, Testing and commissioning of
"Non Clog type Centrifugal Pump Set for effluent" with accessories and
allied Electro-Mechanical and Instrumentation and SCADA work at MRF
Company Pumping Station at Dahej III.
Item Description Qty Unit Rate W/O Amount W/O
1 MECHANICAL WORK 2 Set 799,518.02
Submersible Centrifugal Non Clog
Pump-Motor Set:-Supply, installation,
testing & commissioning of effluent
submersible, non clog type suitable
for working on three phase, 50 Hz ±
3%, 415 V ± 10%, AC supply,
RPM synchronous speed with 3 core
flat copper cable from pump to starter
panel with cable end terminations, all
supports, clamps, pipe fittings along
with mechanical seal, bearing bush,
strainer etc. complete set & following
M.O.C: Casing: CI, Impeller: SS CF8M,
Wearing ring & Bearing bush: Bronze,
TC mechanical seal, CS / SS bearing,
SS shaft with sleeve, SS strainer & MS
Pump Capacity: 338 m3 / hr.
Motor Rating: 42 kW min. (or higher
rating as per pump manufacturer
recommendation)
Starting method: DOL / SD / VFD
(or higher rating as per pump
recommendation)Selection of motor
kw rating if not available in this
rating, next higher rating will be
2 Design, Engineering, procurement, 2 Nos. 66,029.76
Installation, Testing and
commissioning of required size
double flanged Dual Plate Check Valve
(DPCV) - (PN 1.6) - 350 mm dia (At
Pump Discharge) Flanged Dual Plate
Check Valve (NRV) conforming to API
Signature of Contractor Executive Engineer (M&E)
594 / 598 PN 1.6 with Cast Steel body,
with SS 410 hinge ring and wearing
ring of CF8 all necessary hardwares,
complete as per data-sheet &
specification. Size : 350 mm dia( PN
1.6) flanges machined faced and
drilled to IS : 1538 / 1976 Part-IV/VI.
Hydraulic tests certificate & certificate
of material of construction of parts
shall be submitted before dispatch of
valves as per design with required
accessories, erection hardware,
necessary mounting supports etc.
complete. 350 mm dia for various
3 Supply, installation, testing & 2 Nos 13,453.20
commissioning of flange ends
Expansion Bellow as per EJMA
standards of overall length of
minimum 300 mm, designed for
mm axial compression and 5 mm axial
extension with tie rods etc. of
following MOC & pressure ratings.
MOC: Bellows: SA 240 Gr. 304;
Internal Sleeve: SA 240 Gr. 304;
Weldends: IS 2062 Gr. B; Flanges: IS
2062 Gr. B (Drilling as per IS 1538 / IS
6392 ) & Limit Rods & Nuts: CS - IS
1367. PN Rating 1.6, 350 mm Dia.
4 SITC of Cast Steel D/F Electric 2 Nos 930,800.00
Actuator operated Sluice Valve of
following size as per API-
600/598,Class 150 with Electric
Actuator with integral starter & IP-68
enclosure, body, bonnet and wedge of
Cat Steel Gr. WCB with Body & Seat
ring of ASTM A 216 Gr CF8M, spindle
of SS 410, flanges drilled to ANSI B
16.5 of following diameter along with
all other necessary hot dipped
galvanised hardwares, bolts, nuts &
washers, gaskets including all taxes,
insurance, transportation, freight
charges, Inspection Charges, loading
unloading, conveyance to pump
house, stacking, security with
required plain cement concrete (PCC)
support for Valves etc. within pump
house for fixing valve etc. complete as
per Specification and IS.
Signature of Contractor Executive Engineer (M&E)
Size : Dia. 350 mm
5 Provide and supply CI Temper Proof 1 Nos 49,161.75
Air Valves with SS 304 Float Gun
Metal Nozzle of approved make and
quality of following dia of 1.6 PN
rating given rate including all taxes,
insurance, transportation, freight
charges, inspection charges, loading
and unloading conveyance to
departmental store/site Etc.with
Isolating Sluice Valve.
Size : 350 mm NB
6 SITC of suitable size of above pipes of 100 Kg 58.58
flanged end type fabricated DI/CI
Specials like tee, bend, duck foot bend,
tapper, distance pipe piece, blank
flange, dismantling joint, bolts, nuts,
washers, rubber packing etc. nut bolts
etc for delivery header, rising main
and suitable for above pumps as per
actual site conditions & requirement
qty. of specials mentioned as per
design requirement with required
accessories, erection hardware,
necessary mounting supports etc.
7 Supplying and fixing Steel chequered 20 Sq. Mtr 5,780.23
plates having 12 mm thickness, duly
painted with two coats of black Japan
colour. (Average Wt 200.3 kg /
8 Supply, cutting, welding, installation, 8 Rmt 1,456.42
connection with main header, testing
and commissioning Making of Flanged
joint to flanged DI/CI pipes of all
classes/ Special etc. including all
taxes, insurance, transportation,
freight charges, inspection charges,
loading and unloading conveyance to
departmental store/site Etc
Size: 350 mm dia.
9 Single Girder EOT CraneSupply, 1 Set 511,312.50
installation, testing & commissioning
single girder type fully electrically
operated EOT crane with electrically
operated hoist, class II duty, geared
travelling trolley with seven meter lift
complete with long travel rail track
(40 mm sq. bar), moving or cross
Signature of Contractor Executive Engineer (M&E)
girder, all three motions electrically
operated by suitable rating motor IP
54, control panel & down pendant
control block, brake, safety device,
cables form motor to starter panel &
other required accessories & tested as
per IS Specifications.Capacity- 2 T,
Span- 6-9 Mtr, Long Travel- 12 Mtr,
10 SITC Chain Pulley block of 2 ton 1 Nos 17,574.00
capacity, lift as per site condition with
gantry girder, erection hardware,
necessary mounting supports etc
complete. make as per annexure.
11 DEWATERING PUMP 2 Nos 147,811.48
Supply, erection, testing and
commissioning of non clog
submersible Drain Pump with CI
casing & CF8M impeller, including
necessary accessories and hardwares,
etc., 15m cable for motor to starter
panel, suitable for 3Phase, 415 V,
Hz AC supply and min. 2.2 kW motor,
Switch-Starter panel with suitable
inter lock for winding protection, min.
10 m long required size cable to
supply power to control panel from
nearby power source, moisture
controller along with level switches
for dry run protection for auto stop
facilities, cable termination junction
box of required terminal size,
supporting arrangement for pump
and other required accessories,
Capacity : 10 - 15 m3 / hr.
( to be installed in dry well drain pit.)
12 PORTABLE DEWATERING PUMP / 1 Nos 194,690.63
Supply and testing of Submersible non
clog Portable Dewatering Pump set
with C.I. casing & CF8M impeller, 25 m
flexible PVC delivery hose pipe of
pump delivery size, rated for 6.0 kg /
cm2 pressure, 15 mtr SS lifting chain,
20m pair of cable for motor to starter
panel, suitable for 3Phase, 415 V,
Hz AC supply and min. 5.5 kW motor,
min. 10 m long required size cable to
supply power to control panel from
Signature of Contractor Executive Engineer (M&E)
nearby power source, Switch-Starter
panel with suitable inter lock for
winding protection, moisture
controller & dry run protection auto
stop facilities, SS/CI pump stool and
other required accessories for wet
Capacity : 50 m3 / hr.
Motor Rating: Mini. 5.5 kw
13 MISCELLANEOUS: 800 Kg 65.49
Providing, Supply of Structure Steel at
site of work with freight, loading,
unloading carting, etc. including all
taxes and duties complete such as
joints, channels, angles, plates, iron
rails, ISA/ISMC/ISMB/MS flat, plate
(below 10mm thickness) etc.
required for support structure of
Elecrto-Mechanical equipments etc.
for support on floor / wall / beam /
brackets etc. as per tender and IS.
14 Labour Charges for lowering, laying, 1 MT 11,478.65
Fixing with fabrication various size
section of MS such as joints, channels,
angles, plates, iron rails,
ISA/ISMC/ISMB/MS flat, plate etc
Complete with two coats of red oxide
and two coats of approved colour
shade of epoxy paint as per relevant IS
and as per specification.
15 Tools as per Annexure (M) and as 1 Lot 250,000.00
recommended by manufacturer as
approved by engineer in Charge.
16 ELECTRICAL WORK 1 Nos 37,601.29
TPN MCCB (For LT Service Obtaining
SITC of 200 A TPN microprocessor
MCCB with O/L, S/C & E/F protection
with Extended rotary handle,
Terminal spreader, Auxiliary change
over & Trip contact, with Outdoor
Enclosure with canopy 2mm thick
Single/double door & Wall mounted/
stand mounted as per site
requirement (with incoming &
outgoing cable entry at bottom )with
Cable end boxes with RYB indicating
lamp, Digital voltmeter, VSS, ON,OFF
& Trip indicating lamp etc as per
Signature of Contractor Executive Engineer (M&E)
Power supply company requirements
& location. Including all civil works for
fixing of panel on wall.
(Wall mounted at Location as per PSC
17 LV APFC PANEL 1 Set 189,950.70
Supply, installation, testing &
commissioning LV APFC panel
consisting of required capacitor banks
for continuous duty to improve P.F.
0.85 to 0.99 in required steps
enclosed in dust & vermin proof
compartment, indoor type, fabricated
from CRCA sheet steel with minimum
thickness of 3 mm for base frame /
channel / gland plates, 2.0 mm for
load bearing members / doors &
mm for internal partitions, minimum
degree of protection - IP 42, busbar
chamber, required size of Al bus bar /
terminals, minimum 10 stage APFC
relay, metering, indicating lamps,
push buttons complete as per IS:
16636-2017 with latest amendment &
detailed technical specification and
data sheet as under
Above 50 & up to 100 KVAR: APFC
panel consisting following items.
a) 250 A, 50 kA for 1sec. TP, TM based
MCCB with spreader terminals &
b) 0-250 A range analogue ammeter
of 96 x 96 mm size with selector
c) 3nos. 250 / 5A, 10 VA CL-1.0 cast
resin type current transformer
d) Suitable rating of MCCB / MCB &
Contactors for each capacitor bank
e) Suitable rating APP type capacitor
banks (vacuum impregnated with
non-PCB / non toxic oil, internally
delta connected with built in internal
fuses complete with discharge
resistances & terminal cover) of
approved make in required steps with
well suited detuned reactor is placed
in series with each capacitor step. (
e.g. 100 KVAR capacity will be
provided in steps of 2 nos x 5 KVAR,
nos x 10KVAR, 2 nos x 15 KVAR &
Signature of Contractor Executive Engineer (M&E)
f) Enclosre dimensions: 2100 (H) x
18 Design, Supply, Installation, Testing 1 Nos 344,504.94
and Commissioning of Power cum
Motor Control Centre of 200 A,
TPN, Power Cum Motor Control
Centre (PCC) cubical having depth not
less than 750 mm throughout the
required length & detachable,
fabricated from 2 mm CRCA sheet
steel, free standing, floor mounted,
compartmentalized, extensible, dust
and vermin proof enclosure, duly
painted provided with required rating
switch gears and shall be complete
with (a) required size of TPN
Electrolyte 100 A Copper bus bar
having cross section not less than
Amp per 1.0 Sq. MM, (b) 3 Nos. -
Amp capacity of 4 pole-
microprocessor based MCCB with
computer interface (2 Nos. for
incomer + 1 No. as Bus Coupler) (c)
Nos. - 100 Amp capacity of 4 pole -
microprocessor based MCCB
computer interface - All release of all
MCCB should have in built power
meter/ analyser having, 3 phase, V,
KW, I, KVA, KVAh, KVArh, PF,
Frequency, harmonic analysis up to
30th harmonic and last ten faults
history.with computer interface
facility and all other required
protection etc., complete. ,The PCC
shall be supplied as per detailed
specifications & single line diagram
(SLD) complete and the instruction of
Engineer In charge.
19 Microprocessor Based LV Variable 2 Nos 111,862.55
Frequency Drive
Supply, installation, testing &
commissioning of 415 V Fully
automatic microprocessor based
Variable Frequency drive for pump
control application as per general
specification as under:
The VFD unit shall have modular
construction, 6 Pulse Bridge rectifier,
speed control by means of sensor less
Signature of Contractor Executive Engineer (M&E)
vector control (open loop), high
torque at low frequencies, locking at
high and low frequency settings, In-
built PID control, frequency accuracy
of ± 0.1 % (min), frequency resolution
of ± 0.1 Hz (min), protections against;
a) overload (motor and drive), b)
short circuit, c) ground fault, d) input
/ output phase loss (open circuit), e)
stalling, f) input / output
undervoltage (momentary power loss
restart), g) input / output overvoltage,
h) over-frequency, i) Input surge, j)
over temperature of heatsink, k) loss
of remote speed signal etc. The VFD
shall also have user friendly
programming software & it shall be
capable of at least two level
parameter setting with password lock
for critical parameters, programming
for I/Os, speed search function, copy
parameters (upload / download) to
other identical unit, tuning to energy
saving mode (maximum efficiency),
event / fault recording (last 5 faults in
non-volatile memory) & RS
communication port (MODBUS RTU
protocol) with required software. for
20 SITC of Lighting Distribution Board 2 Nos. 20,998.91
(LDB) as under:
SITC of 3 Phase 4 Wire 4P, double
door Prewired LDB each for Indoor
Lighting & Outdoor Lighting Suitable
Incoming: 200A FP, ELMCB (30mA)
Outgoing: 63A SP MCB (9 nos.) & 63A
SP MCB (9 nos.)
21 3 Phase 4 Wire TPN, 8 way Pre- 1 No. 8,876.89
wired- aux. Load for Auxiliary
accessories Load power supply (For
1no.EOT Crane at P.H., 1no.WR-DB at
P.H. maintenance floor, 1no. WR-DB at
P.H Pump Floor, 1no. WR-DB at LT
Room, 1 no. WR-DB at Inlet chamber
& rest spare) Incoming: 20A 4P, MCB
'C' Curve Outgoing: 8 nos. 20A 4P MCB
22 SITC of LCS pushbutton station ON & 4 Nos 2,384.61
OFF (E-stop) set complete with
Signature of Contractor Executive Engineer (M&E)
Enclosure, necessary mounting/ fixing
arrangement on wall / pipe support
etc. to be installed near motors for
remote operation, etc. as per IS and
specifications. (including structural
steel) (For 4 nos. for Pump )
23 SITC of Local Control Station with 4 Nos 2,736.09
pendant type Open_Stop_Close
pushbutton set and with Open, Close,
Trip & Local / Remote Indicating
Lamps complete with Enclosure,
necessary mounting/ fixing
arrangement on wall / pipe support
etc. to be installed near motors for
remote operation, etc. as per IS and
specifications (including structural
24 LOW VOLTAGE (LT) CABLES 180 Mtr 135.34
Supply, laying, testing and
commissioning of 1.1 kV,
A2XFY(X)/2XWY(X) XLPE insulated
(IS 7098) AL stranded conductor,
Extruded inner sheath cables as per
specification & IS. The cable when laid
outside the building shall be laid
underground in trench with brick &
sand protection/in DWC pipes as per
specified method and shall be laid in
prepared trench/ on cable tray when
laid inside the building.
SITC of 3.5C x 16 sq. mm. A2XFY(X)
25 3C x 16 sq. mm. A2XFY Cable 180 Mtr 90.90
26 4C x 10 sq. mm. A2XFY Cable 120 Mtr 97.97
27 4C x 16 sq. mm. A2XFY(X) Cable 120 Mtr 109.08
28 4C x 2.5 sq. mm. 2XWY/2XFY(X) Cable 50 Mtr 70.70
29 5C x 1.5 sq.mm. 2XWY(X) Cable 50 Mtr 150.00
30 12C x 1.5 sq.mm. 2XWY(X) Cable 50 Mtr 320.00
31 2C x 2.5 sq. mm. 2XWY(X) Cable 50 Mtr 49.00
32 Single core 95 sq. mm. PVC insulated 20 Mtr 919.10
circular unsheathed copper
conductor flexible Cable (For Power
supply Metering Panel to I/c MCCB
Signature of Contractor Executive Engineer (M&E)
33 CABLE END TERMINATION AND 32 Nos 161.60
SITC of Double compression Ni-
Plated brass cable glands and
crimping type Bimetallic lugs /
sockets with necessary tools and
equipments as specified in
specifications and IS. The glands and
lugs / sockets shall be suitable for
cable size and type mentioned below
& as per specifications.
1) Earthing the glands and armouring
with earthing clamp and jumper and
also connecting to common earth bar.
2) The job also includes, if necessary,
supply & fixing of extension busbar of
same material on MCCB or panel
board terminal / connector to connect
more than one no. of parallel cables or
to connect higher size cable to lower
size unit. The job also includes
earthing the glands and armour of the
cable with common earth bar or
flexible copper mesh.(Cable
termination qty. shall be as per site
3.5C x 16 sq. mm. A2XFY(X) Cable
34 Do as Above 3C x 16 sq. mm. A2XFY 32 Nos 158.57
35 Do as Above 4C x 10 sq. mm. A2XFY 32 Nos 129.28
36 Do as Above 4C x 16 sq. mm. 32 Nos 163.62
37 Do as Above 4C x 2.5 sq. mm. 20 Nos 93.93
2XWY/2XFY(X) Cable
38 Do as Above 5C x 1.5 sq.mm. 10 Nos 128.00
39 Do as Above 12C x 1.5 sq.mm. 10 Nos 218.00
40 Do as Above 2C x 2.5 sq. mm. 10 Nos 49.00
41 Single core 95 sq. mm. PVC insulated 10 Nos 213.11
circular unsheathed copper
conductor flexible Cable (For Power
supply Metering Panel to I/c MCCB
42 CABLE TRAY 80 Mtr 391.88
SITC of G.I. (Hot dip galvanised )
Signature of Contractor Executive Engineer (M&E)
Ladder type medium duty (2mm
thick) Cable Tray with necessary
bends, tees, reducers, covers and
clamps for fixing. All material shall be
Hot dip galvanised as per
Specification. And including all
accessories. 300 x 75 mm - Ladder
43 150 x 50 mm - Ladder type 200 Mtr 339.36
44 Cable Trench, Laying & Installation of 80 Mtr 55.55
Cable: Making cable trench in soft soil
of suitable width of 90cms deep for
laying cable, Sand cushioning and
brick protection on sides and on top
all over the run and back filling the
same and making the surface as
normal ground as per IS &
Specification. (For laying of LT cable
45 CHEMICAL EARTHING SYSTEM 4 Set 10,593.89
SITC of Maintenance free chemical
earthing (copper) with earthpit of
minimum bore size dia. 225mm Safe
Earthing Electrode consisting Pipe-in-
Pipe Technology as per IS-3043:1987
/Tech spec. made of corrosion free
Pipes having Outer pipe dia of
mm having 250 Micron copper
plating, Inner corrosion free Hot dip
galvanised (80 to 100 micron) pipe
dia of 26 mm with copper flat strip
type connection terminal 14mm dia
with constant ohmic value
surrounded by highly conductive
corrosion resistant chemical
compound with high charge
dissipation suitable for electrical
installation & of 3Mtr. length of Pipe
with two nos. 25Kg. bag of Back filling
compound.. (2nos for PLC earthing,
2nos for DG neutral earthing)
NOTE: Earthing Resistance value &
date shall be painted on the chamber
46 SITC of Maintenance free chemical 6 Set 7,095.25
earthing with earthpit of minimum
bore size dia. 225mm Safe Earthing
Electrode consisting Pipe-in-Pipe
Technology as per IS-3043:1987
Signature of Contractor Executive Engineer (M&E)
/Tech spec. made of corrosion free
Hot dip Galvanised (min 150 Microns)
Pipes having Outer pipe dia of
mm , Inner corrosion free Hot dip
galvanised (80 to 100 micron) pipe
dia of 26 mm with copper flat strip
type connection terminal 14mm dia
with constant ohmic value
surrounded by highly conductive
corrosion resistant chemical
compound with high charge
dissipation suitable for electrical
installation & 3Mtr. length of Pipe
with two nos. 25Kg. bag of Back filling
NOTE: Earthing Resistance value &
date shall be painted on the chamber
47 SITC of pipe type earthing having 150 6 Nos 368.65
cms long and 2.5cms dia. Galvanised
iron pipe with coupling and buch
buried in specially prepared earth pit
complete with necessary 8 SWG earth
48 SITC of 50mm(w) x 6mm(T) etc. sizes 276 Kg 77.77
as required, HOT dip galvanized GI
Strip including supply & fixing using
GI spacers, saddles when laid inside
the building and inclusive of
excavation & refilling of earth when
laid outside the building &
interconnection with earth pit & all
electro-mechanical equipments.
(50X6 G.I Strip wt.2.3 kg/m,
49 Supply, laying and erection of 60 Kg 77.77
25mm(w) x 3mm(T) etc. sizes as
required, HOT dip galvanized GI Strip
including supply & fixing using GI
spacers, saddles when laid inside the
building and inclusive of excavation &
refilling of earth when laid outside the
building & interconnection with earth
pit & all electro-mechanical
equipments. (25X3 G.I Strip, 0.6 Kg/m,
50 Supply, laying and erection of 38 Kg 794.87
40mm(w) x 6mm(T) etc. sizes Copper
Strip including supply & fixing of
bolts, saddles when laid inside the
Signature of Contractor Executive Engineer (M&E)
building and inclusive of excavation &
refilling of earth when laid outside the
building & interconnection with earth
pit & Tr. neutral. (40X6 Cu. Strip,
Kg/m, 1.88 x 20mtr.=38Kg.)
Copper Bolt,Nuts ,Washers shall be
used for Connecting Earth electrode
to individual eqp. Bitumen shall be
used at the place of joint/welding.
51 Supply, laying and erection of 15 Kg 794.87
25mm(w) x 3mm(T) etc. sizes Copper
Strip including supply & fixing of
bolts, saddles when laid inside the
building and inclusive of excavation &
refilling of earth when laid outside the
building & interconnection with earth
pit & PLC panel. (25 X3 Cu. Strip,
20mtr.=15.22Kg.)
Copper Bolt,Nuts ,Washers shall be
used for Connecting Earth electrode
to individual eqp. Bitumen shall be
used at the place of joint/welding.
(PLC Panel Earthing)
52 SITC of HOT Dip Galvanized iron strip 10 Kg 77.77
wire 8 SWG (For LDB, LCS, etc.)
(8 SWG G.I Strip, 0.103 Kg/m, 0.103 x
53 INTERNAL WIRING 150 Mtr 82.82
SITC of Mains & outlet points wiring
with 1.1 kV grade FRLS PVC insulated
ISI marked flexible stranded copper
conductor wires with medium class
min. 25mm. dia. Electrical grade PVC
pipe and accessories to be erected
concealed in / to be run on surface /
wall / ceiling with following sizes as
mentioned below. The unit rate
wirings shall be with connector, PVC
junction box, wires, holder, ceiling
rose, angle holder, switch, sockets,
switch board, brass chromium /
cadmium plated machine screws,
phase and neutral wires, green Earth
continuity wires etc. as required to
complete wiring from LDB panel to
the final outlet termination points.
The wiring shall be as per IS:732,
IS:4648 and as per tender
specification / IS.
Signature of Contractor Executive Engineer (M&E)
(a) SITC of Mains wiring with 3 wire
54 SITC of Mains wiring with 3 wire 2.5 100 Mtr 102.01
sq.mm as per tender specification &
55 SITC of Mains wiring with 4 wire 1.5 100 Mtr 90.90
sq.mm as per tender specification &
56 SITC of Mains wiring with 4 wire 2.5 80 Mtr 126.25
sq.mm as per tender specification &
57 SITC of Point wiring for Light / fan / 37 Nos 354.51
Bell / Primary Point with 2nos. 1.5 sq.
mm & earth wire of 1.5 sq. mm
(green) both are of ISI marked 1.1 kv
grade FRLS PVC insulated multistrand
copper wires , pipe to be erected
concealed in flushed on wall / ceiling,
complete with 6A Tissino Type ISI
marked flush type switch / bell push
& accessories erected on metal / PVC
Box covered with 3 mm thick PC
(Polycarbonate) / Acrylic sheet with
necessary lamp holder / ceiling Rose
/ H. D. connector as directed with
medium class Rigid PVC pipe &
58 SITC of 6A independent Plug with 6 Nos 313.10
2nos. 1.5 sq.mm Cu. Mains size wiring
& earthwire of 1.5 sq.mm (green) both
are of ISI marked 1.1 KV grade FRLS
PVC insulated multistrand copper
wires with medium class Rigid PVC
pipe and accessories to be erected on
wall / ceiling, complete with ISI
marked 3 / 5 Pin socket and tissino
type switch erected with earth
continuity connection erected on
Metal / PVC box covered with 3 mm
thick PC(Polycarbonet) / Acrylic
59 SITC of 6/16A independent Plug with 6 Nos 607.01
2nos. 4 sq.mm Cu. Mains size wiring &
earthwire of 2.5 sq.mm (green) both
are of ISI marked 1.1 KV grade FRLS
PVC insulated multistrand copper
wires with medium class Rigid PVC
pipe and accessories to be erected on
wall / ceiling, complete with ISI
marked 3 / 5 Pin socket and tissino
Signature of Contractor Executive Engineer (M&E)
type switch erected with earth
continuity connection erected on
Metal / PVC box covered with 3 mm
thick PC(Polycarbonet) / Acrylic
60 SITC of Single Phase 20A 3 Pin Metal 4 Nos 820.00
clad Industrial Type Socket with plug
top and 20A SPMCB, suitable for flush
mounting, in 16 SWG MS box of
suitable size and covered with 3 mm
thick electrical grade hylam sheet or
equivalent ISI marked Electrical grade
Bakelite sheet and earthing with
sq.mm insulated copper wire run
inside the conduit including
interconnections etc. complete as
61 LED LIGHT FIXTURES & LIGHTING: 25 Nos 589.84
SITC of Indoor wall mounting 20Watt
or up to 25% higher wattage LED
feet Tube Light indoor fittings with
LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with
housing used as a heat sink shall be
made of thick sheet Steel conforming
to IS: 513/CRCA polyester powder
coated and high U.V. & corrosion
resistance with diffuser and/or
Polycarbonate optics with company
120 to 300 V,Power Factor more than
CCT 4000 K to 6500K, Uniformity
Luminaries efficacy> 85 lumens/watt
LED driver efficiency > 85 %
(Each fitting required LM-79 & LM-80
Tube Light with integral / non-
integral driver, Surge-4KV,IP-20,
62 3 watts LED Lamps integral type,cool 4 Nos 273.71
white with PC diffuser suitable for
B22 LAMP holder
63 SITC of 380mm sweep 1400 R.P.M 2 Nos 3,082.52
exhaust fan, capacitor type, having
double ball bearing, M.S.blades,
mounting frame, forearms, suitable to
operate on 230V,50 HZ AC supply
conforming to IS: 2312.Fan shall be
Signature of Contractor Executive Engineer (M&E)
painted with epoxy grey colour
controlled by one 6 A flush type
switch on board and 6A plug point
64 SITC of 40W LED Surface / Wall 3 Nos 5,194.43
mounted LED Flood Light fittings with
High power White LEDs wattage of
1Watt and above assembled on single
MCPCB, efficiency more than
lm/w and corrosion free High
pressure die cast aluminum housing
with smooth finish powder coated and
heat sink extruded aluminium with
diffuser and Polycarbonate optics/
lenses with company mark/name
engraved or embossed
120 to 300 V,Power Factor more than
Uniformity ratio >0.45, Luminaries
efficacy> 85 lumens/watt . LED driver
efficiency > 85 %.
( Each fittings required LM-79 & LM-
80 certificates)
(IP-65), Surge -4KV Cat-III
For Indoor use: (3 nos. at Pump
65 SITC of 'B' class galvanised iron pipe 11 Nos 558.53
32 mm outside dia 45 cms long duly
welded on 20 cms x 20 cms x 3 mm
thick M.S. base plate, erected on wall
or corner for mounting luminaries
with necessary hardware materials
duly painted for wall mounting indoor
flood light fixtures on Wall of
Buildings & post top lantern.
66 EXTERNAL LIGHTING (Flood LIGHT): 4 Nos 6,088.28
SITC of 70W LED Wall mounted LED
Flood Light fittings with High power
White LEDs wattage of 1Watt and
above assembled on single MCPCB,
efficiency more than 130 lm/w and
corrosion free High pressure die cast
aluminum housing with smooth finish
powder coated and heat sink extruded
aluminium with diffuser and
Polycarbonate optics/ lenses with
company mark/name engraved or
120 to 300 V,Power Factor more than
Signature of Contractor Executive Engineer (M&E)
Uniformity ratio >0.45, Luminaries
efficacy> 85 lumens/watt . LED driver
efficiency > 85 %.
( Each fittings required LM-79 & LM-
80 certificates)
(IP-65), Surge -4KV Cat-III
For Outdoor use:
67 SITC of 40watt, Cat-III Post Top 2 Nos 4,819.72
Lantern LED fitting comprises of
MM TOP Diameter, 120 degree beam
angle with Supporting Ribs and with
0.5mt. G.I. fitting pipe (for Gate light)
68 EXTERNAL LIGHTING (STREET 4 Nos 10,178.78
SITC of Street Light Pole, steel tubular
swaged type, 7.5 meter long with
single arm & M.S.base plate with pipe
cap and over hung 1.5 m long having
dia to suit the socket of 240V LED
street light fixtures. Street light pole
unit rate shall be with (i) IP 65 SMC
box of size 20 x 15 x 15 cms. with
MCB & terminal strip inside the box
with hinged/sliding door (ii) 50mm
dia, B class GI pipe bracket
min.1.5mtr long for Incoming &
outgoing cable (iii)MS Cable Clamp of
25 x 3mm (iv)SITC of 1.5 Mtr.single
Arm bracket of medium duty MS pipe
of 4.2 cms. Out side dia complete with
suitable sleeve tubing 45 cms. long of
required size of pole top etc. and
having spread of 1.5.mtr. length with
110 deg.(v) Complete painted with
one coat of Red oxide / PU base
primer and two coats of Aluminium /
PU paint for Pole,Arm, pipe etc.
69 SITC of 70 W LED Street light fittings 4 Nos 5,976.17
with High power White LEDs wattage
of 1Watt and above assembled on
single MCPCB, efficiency more than
130 lm/w and corrosion free High
pressure die cast aluminum housing
with smooth finish powder coated and
heat sink extruded aluminium with
diffuser and Polycarbonate optics/
lenses with company mark/name
engraved or embossed
Signature of Contractor Executive Engineer (M&E)
120 to 300 V,Power Factor more than
Uniformity ratio >0.45, Luminaries
efficacy> 85 lumens/watt . LED driver
efficiency > 85 %.
( Each fittings required LM-79 & LM-
80 certificates)
Street Light (IP-65), Surge -4KV,
70 SITC of M-20 / 1:2:4 cement concrete 4 Nos 1,292.80
foundation for Street light pole &
% PCC from bottom including
excavation for the pole of size 60 x
x 120 cms. Deep in below ground level
with plinth of 45 cms x 45 cms(or
cms dia x 45 cms) high upper ground
level with necessary curing and
finishing in approved manner.
71 DIESEL GENERATOR SET 2 Each 720,245.14
SITC of 75 kVA or higher standard
rating, 415 V,50 Hz, 3 Phase, 4 wire
Diesel Generating Set. Diesel engine
shall be complete with necessary
controls and safety devices confirming
to relevant IS/BSS with latest
amendments, DG controller unit with
kWH meter. Diesel Engine shall be
suitable for continuous operation of
generator set duty inclusive of fly
wheel, air cleaner, radiator. fan with
guard, fuel pump, fuel filter, Electronic
governor, auto main fail starting,
electrical starting system with starter,
12V battery, voltage regulator,
instrument panel, Exhaust silencer,
protections against low lubrication oil
pressure ,high water temperature.
Alternator shall be 415V, 3 phase,
Hz, 4 wire, 0.8 power factor, self
excited,self regulated, brushless
type,drip proof confirming to IS:4722
with latest amendments.
The engine and alternator shall be
coupled over a sturdy common base
frame. Floor mounted, dust & vermin
proof, indoor type control panel shall
be consisting of Thermal magnetic
MCCB of suitable normal current
rating, with combined overload and
Signature of Contractor Executive Engineer (M&E)
earth fault protective relays/release,
voltmeter with selector switch,
ammeter of suitable range with
selector switch, frequency meter,
Energy meter, CTs, indicating lamps
with fuse and switch control,
complete & with necessary inter
connections, fuses, labels and other
accessories. Day fuel tank with
necessary fuel hoses to the engine, all
as per detailed specification and
complete in all respect as required.
72 SITC of Acoustic enclosure suitable for 2 Each 192,414.09
75 kVA DG set, made out of 18 SWG,
CRCA Sheet, Sound absorbing material
Rockwood of 64 density & 100 mm
thick conforming to IS:8183. The resin
bonded Rockwood covered from
inside level not more than 75 dB at a
distance of 1 mtr, as PVCT / CPCB
norms, on provided foundation.
73 Providing & laying of 50 MM Nominal 50 Mtr 62.62
OD Doubled Walled Corrugated Pipes
(DWC) of polyethylene (conforming to
IS 14930 - II) with necessary
connecting accessories like coupler,
Tee, L - Bow, etc. of same material at
required depth (90 cms) including
excavation for laying of cable below
ground/ road surface for enclosing
cable and back filling the same to
make ground as per original & as per
instruction of Engineer Incharge -
74 Lightning Protection system for 1 Nos 60,760.00
highest building at plant area by air
terminal with rod and GI strip
conductor test link to earth electrode
as per requirement
75 SAFETY ACCESSORIES 2 Nos 8,671.86
SITC of following safety accessories
complete with necessary fixing
brackets, other accessories and tools
etc. as required to complete the job.
Supply & Erecting carbon dioxide
(CO2) fire extinguisher of 6.5kg
capacity with necessary clamps made
from 50 x 6 mm M.S. Flat with nut &
bolts grouted in wall complete.
(For 1 no. for LT Room, 1 no for DG
Signature of Contractor Executive Engineer (M&E)
76 Supplying & erecting D.C.P. type fire 2 Nos. 2,226.04
extinguisher for following capacity
cartridge type with gun metal cap
gram CO2 gas cartridge, powder and
brackets confirming to IS 2171
and complete erected with necessary
clamps made from 50 x 6 mm MS flat
with nuts and bolts grouted in wall
complete, 10 kg
77 Supplying of standard first AID box 1 Nos 299.97
with antiseptic cream, medicine for
use on wounds due burn, crepe
bandage, guage bandage, medicated
ready to use bandage (Band-aid)
adhesive tape for medicinal user,
scissors, antiseptic solution (Savlon or
similar) etc. (All above contents shall
be of standard makes)
78 Supply & fixing of printed instruction 1 Nos 130.29
(First Aid) Chart both in English and
Gujarati and duly framed with front
glasses, for treatment of person
suffering from electric shock.
79 Supplying & fixing of floor mounting 1 Nos 1,798.81
stand for keeping four nos. of FIRE
buckets comprising 1500 mm in
length, 900 mm height frame made
out of 30mm X30 mm X 4 mm angle
iron with cross supports for legs,
welded with 4 hooks and duly painted
with one coat of red lead and two
coats of approved enamelled silver
paint. ( 1 set for Dg set)
80 Supply and fixing of 20 W fluorescent 17 Nos 2,540.00
lamp operated emergency light with
maintenance free battery for 3 hours
operation during mains power failure.
81 Supply and laying of Synthetic 4 Sq.mtr. 1,027.17
Insulating Mat of Class - A of min.
thickness 2mm as per IS:15652 and
with good electrical insulation
property for 1.1KV/3.3KV as per site
requirement. (For LT Panel)
82 Providing pair of rubber hand gloves 1 Nos 214.12
ISI make suitable for working on
83 LIASONING CHARGES FOR 1 Nos 10,000.00
Signature of Contractor Executive Engineer (M&E)
Power Liasoning Charges for
obtaining N.O.C from Electrical
Inspector / Statutory authority for
Power / Ele. Installation. (Fees shall
be paid by tenderer for obtaining
N.O.C. from Electrical Inspector /
Statutory authority on behalf of client
and shall be reimbursed on
submission of original receipt to
Liasoning Charges shall include
preparing required attested
documents & drawing for obtaining
NOC on behalf of client (Applicable
Fees / deposits shall be reimbursed
84 INSTRUMENTATION WORK 5 Nos. 1,426.12
PRESSURE MEASURING SYSTEM:
SITC of 0- 10 kg / cm2 - 150 mm dia,
size Pressure Gauge Design, Supply,
Installation, Testing, Commissioning
of Bourdon Type Pressure Gauge,
±1% accuracy, Direct bottom 1/2"
NPT (M) process connection, IP
Glycerine filled, SS304 Case with
Bayonet Type Bezel, SS316 L Bourdon
Tube, SS 316 Movement material,
Aluminium dial with black graduation
on white background, Micro Zero
adjustable pointer, neoprene gasket,
Blow out disc, shatter proof glass, SS
tag plate etc as per IS
85 Supply, installation, testing and 5 Nos. 29,438.47
commissioning of Pressure
Transmitter with local display along
with two valve manifold, required
fittings, tubing (all valves, fittings,
tubings, etc. shall be in SS 316 only),
all accessories, hardware, etc.
complete in all respects as per
specifications and having following
measurement ranges: Range : 0 -
4Kg/cm2 (at each pump delivery side
and Pump header )
86 LEVEL MEASURING SYSTEM FOR 5 Nos. 60,030.36
Supply, installation, testing and
commissioning of Ultrasonic type
Level Transmitter with remote type
transmitter with 20 meter cable
Signature of Contractor Executive Engineer (M&E)
between Sensor and Transmitter
along with all required accessories,
Weather proof enclosure for
transmitter for outdoor application,
mounting stand , etc. complete in all
respects as per specification and
having following measurement ranges
for liquid (Effluent) application:
Meas. Range: upto 10 m
87 Supply, installation, testing and 2 Nos 12,930.02
commissioning of Displacer type
Level Switch SS Float for dry run
protection of pump through relay
multiplication in PLC), etc., complete
in all respects and as per
Meas. Range: upto 10 m
88 ELECTRO MAGNETIC FLOWMETER 3 Nos 206,534.90
Supply, installation, testing and
commissioning of Full Bore
Electromagnetic flow meter
comprising of IP-68 Sensor with PTFE
liner , Hastelloy-C Electrode, IP-66
transmitter with 20 m cable between
sensor and transmitter along with all
mounting accessories, Weather proof
enclosure for transmitter, hardware,
mounting stand, etc. as per
specification and to complete the
work in all respect as per site
condition necessary connection with
pipe and shall have following size. PN
Meter Size : 350 mm NB
89 PLC BASED CONTROL PANEL 1 Nos 350,000.00
Supply, Installation, Testing &
Commissioning of PLC Based
Instrument control Panel with 10"
color touch screen HMI, 4G GPRS
modem with (ethernet port + SIM
slot) with SIM Card for Remote data
transmission to TEPS for monitoring
and control the EPS from TEPS,
Communication port for MFM , PLC
with Conformal Coating with ISA-
S71.04 severity level G1;G2 as a min.,
Power Surge Protection device in
Incoming 230V AC Power supply to
Signature of Contractor Executive Engineer (M&E)
UPS, 1 no. Spilt type Air Conditioner
(2 Ton 5 start rating ) , Instrument
Control Panel '(PLC Enclosure / Panel
) with necessary PLC based logic and
wiring , Min. 1 kVA online UPS (with
60 min backup along with filter for
harmonic, suitable rating SMF inbuilt
batteries along with battery charger
and all other accessories as per
standard), etc. complete in all respects
and as per specs with PLC having
minimum I/O count of 70DI /30DO /
12AI /4 AO. These are the minimum
IO requirement if any other IO,s
required to complete the work
contractor shall be provide the same
without any extra cost.
90 INSTRUMENT CABLE & ACCESSORIES 80 Mtr 144.00
'Supply, Laying, Installation,
Connection, Termination, Testing &
Commissioning of Instrument Cables
as per specs. The unit rate shall
a)Supply, loading & unloading of the
cable at site from store.
b)Shifting of cable from site store to
place of installation.
c)Fixing of cable clamps, brackets,
supports, route markers etc. where
ever required to fix the cables safely.
d)Excavation, back filling and levelling
of ground along with laying of fine
sand, protection bricks and other
necessary civil material for laying
cables outside the building.
f)Testing and submission of sketches
& reports of all the cables laid.
91 SIGNAL CABLE 80 Mtr 118.00
92 CONTROL CABLE 80 Mtr 270.00
93 INSTRUMENT CABLE TRAY 80 Mtr 832.00
Supply and installation / erection of
Perforated type cable tray of
galvanized mild steel sheets of 2 mm
thickness with required, hardware,
fitting and support structural
Signature of Contractor Executive Engineer (M&E)
accessories . All material shall be Hot
dip galvanised as per IS 2629 and
tray hardware shall be in GI. Support
structure shall be of structural steel
for mounting the cable tray on wall /
cable trench or as per site condition,
600 X 25 mm - Perforated type
94 200 X 25 mm - Perforated type 80 Mtr 322.00
95 50 X 25 mm - Perforated type 80 Mtr 107.00
96 CABLE END TERMINATION AND 20 Nos 136.00
'Supply, fixing, connection, testing and
commissioning of double compression
brass cable glands and crimping type
Bimetallic lugs / sockets with
necessary tools and equipments as
specified in specifications and IS
complete in all respects. The glands
and lugs / sockets shall be suitable
for cable size and type mentioned
above. The job also includes earthing
the glands and armour of the cable
with common earth bar or flexible
copper mesh as applicable.
97 SIGNAL CABLE 24 Nos 136.00
98 CONTROL CABLE 38 Nos 296.00
99 IoT Based Dual Protocol (GSM + LAN) 1 Nos 19,500.00
Gateway for Centralise Monitoring
and Data Connectivity to GPCB and
CPCB. Cloud Software Charges for the
100 Cloud Software Platform and IIoT 1 Nos 4,550,000.00
Sensors for Predictive Maintenance
and AI Powered Electrical Signature
Analysis for Electrical Pumps.
Total Amount Without GST in Rs.
Total Amount Without GST in Rs.
*The rate shall be Exclusive of all taxes (Excluding GST)
I/We agree to carry out above work at __________ % above the estimated Rate put to tender
Percentage in words ( _______________________________)
I/We agree to carry out above work at __________ % below the estimated Rate put to tender
Percentage in words ( _______________________________)
Signature of Contractor Executive Engineer (M&E)
Estimated Amount put to Estimated Amount put to
Tender Rs. 1,47,65,058.00 Tender Rs.
Add % Above Rs.____________ . Deduct % Below Rs.____________
Net Amount Rs.____________(In figures). Net Amount Rs.____________(In figures)
I/we have read the condition mentioned in this tender and agree to abide by the sam
IMPORTANT NOTE:
The rate of each items should be offered inclusive of Excise duty, packing, forwarding, insurance,
loading, unloading, shifting & transportation at store/site except GST of work of the estates under
GIDC, Bharuch GST will paid extra Please note that the agency, in whose favour the tender is
finalized by the competent authority, should have to submit the document like insurance of the
staff engaged RPFC No., Labour license etc.
1. I / we agree to supply the above materials at the rate mentioned above.
2. I / we have read the conditions mentioned in this tender & agree to abide by the same.
3. GIDC will not issue any tax exemption form i.e. ‘P’, ‘C’ or ‘D’. The tenderer may quote
rates accordingly.
4. The agency in whose favour tender is finalized has to enter into B1 agreement and
conditions and clauses of the agreement shall be binding to the agency. If agency desire
to study, the same is available from Engineer in Charge during working days and office
5. The tendered has to inspect the site and found out the quantum of repairs/overhauling
service work involved before quoting the rates.
6. Labour work required for handling, lifting lowering, shifting, loading, unloading,
transportation etc. of any pumps & allied equipments with tools & tackles shall be
arranged by the tenderer.
Signature of Contractor Executive Engineer (M&E)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Bank Guarantee.pdf
Modified schedule.pdf
Volume - I (PQ).pdf
Volume - II (Technical Bid).pdf
Price bid.pdf
B1 Agreement - Part 1.pdf
B1 Agreement - Part 2.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .