Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC | L1 | Accepted-AOC L1 |
Tender Value
₹5.5 L
EMD Value
₹13,870
Closing Date
11 Feb 2025, 2:00 pmClosed
Assistant Executive Engineer
WSP SUB DIVISION, HARIPAD
DEPOSIT-KAYAMKULAM MUNICIPALITY- ANNUAL PLAN - 2022-23-CONSTRUCTION OF PUMP HOUSE, LAYING PUMPING MAIN, SUPPLY AND ERECTION OF PUMP SET AND COMMISSIONING OF NEW TUBE WELL NEAR COIR CO-OPERATIVE SOCIETY (107) COMPOUND (MACHAMKULAM) IN WARD 41
2025_KWA_734634_1
WRD/KWA-CE(CR)/TR/19338/2024
Open Tender
Civil Works - Water Works
Item Rate
90 days
WSP SUB DIVISION, HARIPAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,225
₹13,870
21 Apr 2025
5 Feb 2025
12 Feb 2025
5 Feb 2025
11 Feb 2025
5 Feb 2025
Amount
APPENDIX A :- PART I - CIVIL WORK - CONSTRUCTION OF PUMP HOUSE.
50.2.26.1:Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.6.1.4:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
12.1.3:Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/m2
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
9.95.3:Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:100x75x4 mm
9.97.3:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm
50.9.15.1:Supplying and fixing 200 mm Aluminium aldrop
APPENDIX B :- PART II - ELECTRIFICATION OF PUMP HOUSE
OD100053/2024-2025:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface I recessed mediumclass PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper Group B conductor single core cable etc. as required.
OD100054/2024-2025:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with lSI marked HRC fuses including drilling holes in cubiclepanel, making connections, etc. as required. 63ATP&N
OD100055/2024-2025:Earthing with G.l. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate Jlaving locking arrangement and watering pipe etc. with charcoal/coke and salt as required
OD100056/2024-2025:Installation, testing and commissioning of pre-wired, fluorescent fitting I compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc.directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
OD100057/2024-2025:Supplying fluorescent lamp set 36/40 W with all accessories
OD100058/2024-2025:Supplying and fixing metal box of 200 mm X 125 mm X 60 mm size (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
OD100059/2024-2025:Supplying and providing meter box and panel board for KSEB supply and providing necessary fuse unit and isolators for 3 phase supply as per the direction of departmental officers.
APPENDIX C :- PART III - LAYING PUMPING MAIN - WORKING CHARGES
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.98.1008:Engaging Coolie.
100.9.9:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outside diameter pipes.
OD100050/2024-2025:Interconnecting the newly laid 110 mm PVC pipe line to the existing 110mm PVC line by cutting the existing line diametrically, the cut being diametrically perpendicular to the axis of the pipe and smoothening the cut ends and inserting the suitable specials supplied by the contractor, placing in position .jointing with CIR Joint and testing to the required test pressure including cost of Tee, labour charges, hire for tools etc. complete
OD100051/2024-2025:Providing interconnection between 80 mm GI pumping line (column/delivery pipe from well) with newly laid 110 mm PVC pipe line using 80 mm GI pipe -1.50 M, 90 mm PVC adaptor- 1 Nos, t etc including providing 65/80 mm CI/GM sluice valve in delivery line for scouring arrangement etc complete including cost and conveyance of GI pipe, valves and all specials for interconnection works, all fabrication charges, all labour charges including excavation and refilling the trenches for interconnection work etc complete as per the direction of engineer in charge.
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
APPENDIX C :- PART IV - LAYING PUMPING MAIN -COST OF MATERIALS
100.98.214:Supply of PVC Pipe, 6kg/cm2, 110mm Dia.
OD100041/2024-2025:Supplying 110mm PVC bend (6Kg/cm2) shall be of reputed brand
APPENDIX D :- PART V : SUPPLY, ERECTION AND COMMISSIONING OF SUBMERSIBLE PUMP SET.
OD100043/2024-2025:Supplying 80 mm GI B Class pipe having weight not less than 8.5 Kg/m having ISI mark.
OD100044/2024-2025:Supplying good quality ISI marked 3 x 4 square mm flat type copper submersible cable.
OD100045/2024-2025:Supplying 80mm GI bend
OD100046/2024-2025:Supplying good quality Fabricated 80 mm GI TEE.
OD100047/2024-2025:Supplying 80 mm MS Flange
OD100049/2024-2025:Providing bleaching powder solution feeding unit for disinfection of water consisting of supplying and providing polyethylene water storage tank (ISI marked) with cover and suitable locking arrangement of capacity 500 Ltr, providing platform of size 1.25 M x 1.00 M for placing PVC tank by structural steel work riveted, bolted or welded in built up sections including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using ISA 75 x 75 x 6, providing 20 mm CPVC pipe connection for inlet water supply to tank from pumping main and out let supply from tank to bottom of tube well including providing two number ball valves in inlet line and one valve in outlet line and providing 50 mm CPVC pipe darin outlet in tank for scovring arrangement including providing 50 mm PVC ball, valve in drain pipe and making the unit functional for collecting water from pumping main and continuous feeding of bleaching powder solution to tube well etc complete including cost and conveyance of polyethylene water storage tank (ISI marked) with cover and suitable locking arrangement of capacity 500 Ltr - 1 No, Steel structural platform using ISA 75 x 75 x 6 - 108 Kg, inlet and outlet pipe connection using 20 mm CPVC pipe and specials - 66 M and valves, drain arrangement all labour charges, supplying 30/40 Ltr PVC bucket - 2 Nos and PVC mug - 2 Nos (for mixing bleaching powder), hire charges of tools etc complete as per the direction of engineer in charge.
100.31.1.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class I.
100.98.482:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 100mm.
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.9.6:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes.
100.98.234:Supply of PVC Pipe, 10kg/cm2, 63mm Dia.
OD113423/2024-2025:Cost of 63MM PVC BEND
Bidder Name
C Jayaprasad
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1175686.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .