Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.2 LAccepted-AOC HOUSE NO 36 93 354 9 INDIRA NAGAR 5 NH 16 KANCHARAPALEM POST VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | 1 | Accepted-AOC ACCEPTED BEING THE LOWEST TENDERER | |
| 2 | 2₹4.6 L+₹12,598.50 (2.83%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹4.8 L+₹33,789.83 (7.58%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
10 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I CG VIZAG
AGE I CG VIZAG MES CGWO BLDG FLEET MAIL OFFICE MALKAPURAM 530014 0891 2743118
REPAIR MAINT OF INTERNAL ELECTRIC AND OTHER RELATED WORKS AT COAST GUARD JETTY AND CG ENCLAVE UNDER AGE I CG VIZAG UNDER AGE I CG VIZAG
2020_MES_360459_1
AGE(I)CG/VIZ/TOKEN 09 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
VISAKHAPATNAM
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
AGE I CG VIZAG
₹10,000
Yes
2 Sept 2020
13 Jul 2020
12 Aug 2020
13 Jul 2020
10 Aug 2020
27 Jul 2020
60 days
Amount
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc. and making good all disturbed surfaces of wall, floor etc. by means of cement mortar (1 : 3) or plaster of Paris and to match new surface as the existing surface either by using same colour distemper, Putty or white / colour wash all as required and as directed by Engineer-in-Charge.
Taking down main switch/DB/ changeover/AC box of any capacity including fixing accessories complete all as specified and as directed.
M & L for concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc. including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of paris/ Putty or distemper / colour wash with same existing colour surfaces all as specified and as directed by Engineer-in-Charge for the following:- For one light, fan, call bell, 5 Amp independent socket point controlled by one switch. Make of Cable : Finolex/ Polycab/ Plaza/ Gloster/ Havells all are ISI marked and FRLS cables. Make of Conduit : Plaza/Kalinga/AKG/Avon Plast/Precision/ Finolex all are ISI marked.
-Ditto- all as per item No 3 here-in-before but for one socket point controlled by one switch on same board. Make of Cable : Finolex/ Polycab/ Plaza/ Gloster/ Havells all are ISI marked and FRLS cables. Make of Conduit : Plaza/Kalinga/AKG/Avon Plast/Precision/ Finolex all are ISI marked.
-Ditto- all as per item No 3 here-in-before but for one light point controlled by two, two way switch. Make of Cable : Finolex/ Polycab/ Plaza/ Gloster/ Havells all are ISI marked and FRLS cables. Make of Conduit : Plaza/Kalinga/AKG/Avon Plast/Precision/ Finolex all are ISI marked.
All as per item No 3 here-in-before but for power point wiring with 4 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and as directed. Make of Cable : Finolex/ Polycab/ Plaza/ Gloster/ Havells all are ISI marked and FRLS cables. Make of Conduit : Plaza/Kalinga/AKG/Avon Plast/Precision/ Finolex all are ISI marked.
All as per item No 3 here-in-before but in surface Casing /c aping and surface mounted PVC/Poly carbonate sunken boxes of appropriate sizes mounted on surface for the following :- For one light, fan, call bell, 5Amp independent socket point controlled by one switch. Make of Cable : Finolex/ Polycab/ Plaza/ Gloster/ Havells all are ISI marked and FRLS cables. Make of Conduit : Plaza/Kalinga/AKG/Avon Plast/Precision/ Finolex all are ISI marked.
-Ditto- all as per item No 3 here-in-before but For one socket point controlled by one switch on same board Make of Cable : Finolex/ Polycab/ Plaza/ Gloster/ Havells all are ISI marked and FRLS cables. Make of Conduit : Plaza/Kalinga/AKG/Avon Plast/Precision/ Finolex all are ISI marked.
-Ditto- all as per item No 3 here-in-before but for One light point controlled by two, two way switch. Make of Cable : Finolex/ Polycab/ Plaza/ Gloster/ Havells all are ISI marked and FRLS cables. Make of Conduit : Plaza/Kalinga/AKG/Avon Plast/Precision/ Finolex all are ISI marked.
All as per item No 3 here-in-before but in casing /caping for power point wiring with 4 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FR insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead. Make of Cable : Finolex/ Polycab/ Plaza/ Gloster/ Havells all are ISI marked and FRLS cables or equivalent make in list of makes specified in PS. Make of Casing/Caping: Presto Plast / Finolex / Kalinga / Payal all are ISI marked or equivalent make in list of makes specified in PS.
S & F in repairs for switch flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified and as directed. Make: Havells / Anchor / Legrand / Schneider
S & F in repairs for Modular switch single pole one way 5 Amps, 240 volts, white finish complete all as specified and as directed. Make: Havells [Crabtree] / Legrand or equivalent make in list of makes specified in PS.
S & F in repairs for switch flush type single pole two way 5 Amps, 240 volts, white finish complete all as specified and as directed. Make: Havells / Anchor / Legrand or equivalent make in list of makes specified in PS.
S & F in repairs for switch flush type 15 Amps, 240 Volts single pole white finish complete all as specified and as directed. Make: Havells / Anchor / Legrand or equivalent make in list of makes specified in PS.
S & F in repairs for switch Modular type 16 Amps, 240 Volts single pole white finish complete all as specified and as directed. Make: Havells / Anchor / Legrand or equivalent make in list of makes specified in PS.
S & F in repairs , for socket outlet 5 pin, 5 Amps flush type white finish complete all as specified and as directed. Make: Havells / Anchor / Legrand or equivalent make in list of makes specified in PS.
S & F in repairs, for socket outlet 5 pin, 5 Amps Modular type white finish complete all as specified and as directed. Make: Havells / Anchor / Legrand or equivalent make in list of makes specified in PS.
S & F in repairs, socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete all as specified and as directed. Make: Havells / Anchor / Legrand or equivalent make in list of makes specified in PS.
S & F in repairs, socket outlet 2 in 1, 3 pin, 5/15 A, Modular type, 240 V white finish ccomplete all as specified and as directed. Make: Havells / Anchor / Legrand or equivalent make in list of makes specified in PS.
S & F in repairs, for bell push, flush type 5 Amps white finish complete all as specified and as directed. Make: Havells / Anchor / Legrand or equivalent make in list of makes specified in PS.
S & F in repairs , electronic socket size, rotary, 5 speed step type regulator, 120-230 V white finish complete all as specified and as directed. Make: Havells / Anchor / Legrand or equivalent make in list of makes specified in PS.
S & F in repairs , Calling Bell 230 Volt, AC complete all as specified and as directed. Make: Havells / Anchor / Legrand or equivalent make in list of makes specified in PS.
S & F in repairs , ceiling rose, surface backlite, 65 x 20 mm three terminal complete all as specified and as directed. Make: Havells / Anchor / Legrand or equivalent make in list of makes specified in PS.
S & F in repairs, lamp holder insulated body with back plate suitable for angle / batten fitting complete all as specified and as directed. Make: Havells / Anchor / Legrand or equivalent make in list of makes specified in PS.
S & F in repairs , double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed. Make: Legrand/Schiender/L&T or equivalent make in list of makes specified in PS.
S & F in repairs , double door metallic sheet metal enclosure for DB when MCBs to be used SPN 4 ways, 240 V with 200 Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed. Make: Legrand/Schiender/L&T or equivalent make in list of makes specified in PS.
S&F in repairs, double door metallic sheet metal enclosure for DB when MCBs to be used TPNL, 4 ways, 415Volts (horizontal type) with 200 Amps rated bus bar suitable for TPN MCB/ 4 pole Isolator fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as directed. Make: Legrand/Schiender/L&T or equivalent make in list of makes specified in PS.
S & F in repairs, MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having B-curve characteristics connected with suitable lugs. Make: Legrand/Schiender/L&T or equivalent make in list of makes specified in PS.
S & F in repairs, MCB SPN 240 volt 6 Amp to 32 amp 10 KA capacity having B-curve characteristics connected with suitable lugs. Make: Legrand/Schiender/L&T or equivalent make in list of makes specified in PS.
S & F in repairs , TPN 40-63 Amps, 1 having C-curve characteristics connected with suitable lugs complete all as specified and as directed. Make: Legrand/Schiender/L&T or equivalent make in list of makes specified in PS.
S & F in repairs , MCCB 125 Amps, 4 Pole, 415V, 25KA complete all as specified and as diretced. Make: Legrand/Schiender/L&T or equivalent make in list of makes specified in PS.
S & F in repairs , MCCB 100 Amps, 4 Pole, 415V, 25KA complete all as specified and as diretced. Make: Legrand/Schiender/L&T or equivalent make in list of makes specified in PS.
S & F in repairs , MCCB 63 Amps, 4 Pole, 415V, 25KA complete all as specified and as diretced. Make: Legrand/Schiender/L&T or equivalent make in list of makes specified in PS.
S&F sheet metal enclosure , 25A single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 25 Amp fixed properly on in concealed position complete all as specified and as directed. Make: Legrand/Schiender/L&T or equivalent make in list of makes specified in PS.
S&F in repairs, metal clad socket industrial 2 pin & earth plug top 20A, 230V complete suitable for AC Box complete all as specified and as directed. Make: Legrand/Schiender/L&T or equivalent make in list of makes specified in PS.
M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multistranded copper conductor cable of size 6 sqmm drawn in new/existing conduit with 4.0 Sqmm PVC-FRLS insulated unsheathed multistranded copper conductor as a continuous earth wire complete all as specified including taking down old unserviceable sub main wiring complete all as specified and as diretced. Note : (i) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length. (ii) Conduit pipe and fitting will be measured and paid separately. Make of Cable : Finolex/Polycab/Plaza/Gloster/Harsh all are ISI marked and FRLS cables or equivalent make in list of makes specified in PS.
M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multistranded copper conductor cable of size 4 sqmm drawn in new/existing conduit with 2.5 Sqmm PVC-FRLS insulated unsheathed multistranded copper conductor as a continuous earth wire complete all as specified including taking down old unserviceable sub main wiring complete all as specified and as diretced. Note : (i) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length (ii) Conduit pipe and fitting will be measured and paid separately. Make of Cable : Finolex/Polycab/Plaza/Gloster/Harsh all are ISI marked and FRLS cables or equivalent make in list of makes specified in PS.
S&F for energy efficient LED Batten light fitting 1x10 watt complete with all accessories & Provn of three core cable of copper conductor of size 0.75 sqmm, making necessary electric connetion from ceiling rose to fitting terminal , fixing the fitting on wall including all necessary fixing accessories complete all as directed at site. Make : Philips or equivalent make in list of makes specified in PS.
M & L for energy saver LED Bright batten light fitting 22/20 watt, 230 Volts, Box type. etc and accessories, including required fixing arrangements and electrical connection three core copper cable from ceiling rose to light fitting old unserviceable bracket with sketch fitting all all as directed. Make : Philips or equivalent in Havells / Wipro or equivalent make in list of makes specified in PS.
S&F for energy efficient light emmitting for high efficiency Recess mounted LED Luminaire 36 Watt, high Transculent diffuser , soft glare free light suitable for 600mmx600mm for Modular/POP/Gypsum Ceiling complete with all accessories luminaire with CRCA powder coated body & Provn of three core cable of copper conductor of size 0.75 sqmm, making necessary electric connetion from ceiling rose to fitting terminal , fixing the fitting on ceiling all necessary fixing accessories complete all as directed. Make : Philips or equivalent make in list of makes specified in PS.
S & F in repairs of 9 W LED Lamp 220-240V AC 50Hz (85% more energy saving as compared to incandescent lamp. Make: Phillips /Havells/CG/Bajaj or equivalent make in list of makes specified in PS.
S&F rigid non metallic medium white ivory PVC conduit medium grade ISI marked of size not less than 25 mm dia concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed position/surface position including cutting chasing & making good to disturbed surfaces & matching with the existing colour of wall/floor etc. all as directed by Engineer-in-Charge. Make of Conduit : Plaza/Kalinga/AKG/Avon Plast or equivalent make in list of makes specified in PS.
M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL ) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia medium grade, lugs, main Earthing lead upto 7.5 mtr including Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification complete all as specified and as directed.
S & F in repairs, Condensor 2.5 mfd complete all as specified and as directed
S & F in repairs LED street light fittings 25 Watts pressure die cast aluminium housing, heat resistant toughened glass with frame, IP66 protection better optics fro uniform distribution including connection wire from pole box to light of make Havells Cat Part No. ENDURAPEARLSL25WLED757SASYTOP or or equivalent in Havells / Wipro / Crompton or equivalent make in list of makes specified in PS.
K Satyanarayana
SRI SAI VAGDEVI BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .