Loading…
Loading…
Tender Value
₹2.8 Cr
EMD Value
₹3.8 L
Closing Date
25 Sept 2026, 12:30 pm
CME
AOB 2ND FLOOR CME CHAMBER
Manning operation and Maintenance of lighting pertains to Inner and Outer Harbour Western Sector and Outer Harbour, Western Sector, Exim Park and Railway Sidings. Cargo Handling Areas, Road Street Lighting of Residential Colonies of Harbor Park and
2026_VPT_289903_1
169/26-28/IMEE/ELE/AMC385, Dt.04.09.2026
Open Tender
Electrical Works
Works
730 days
VPA
Please refer to the tender documents
2 documents required · 2 mandatory
₹1,770
Yes
₹3.8 L
Yes
4 Sept 2026
4 Sept 2026
26 Sept 2026
4 Sept 2026
25 Sept 2026
4 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Maintenance of industrial lighting system consisting of cargo handling areas, Railway sidings, street lighting, WQ-EQ Berths, Sheds- at Western Sector & Port area, Old & New Flyover Bridge lighting, Residential colonies of Harbour park, power supply maintenance to the above complete as directed including round the clock monitoring of the lighting system, attending of complaints, repairing / replacement of defective switch gears and lighting accessories and maintaining the illumination levels as per norms in the said locations (Annexure-II) and maintenance of operational accessories for lighting system, Switching “ON and OFF” the lighting at all locations, during the sunset / sunrises as per scope of work enclosed in Annexure -I Allocation of the work can be anywhere of the VPA premises as directed by Engineer. I/c | 24 | Months | - | - |
| 1.02 | Supply of tyre mounted, self-travel crane with fuel, suitable bucket arrangement and driver for maintenance of flood / street lights, erection of poles and any associates works connected to electrical maintenance at any location of port area such as LPG,OR-I & OR- II, western sector ,Inner & outer harbor etc. as directed by Engineer. I/c | 300 | Hrs | - | - |
| 1.03 | Supply of 350-400Watt LED Flood light Luminaire made of pressure diecast aluminum housing with powder coated, having protective toughened glass, supply Input voltage 120 - 270 V AC, P.F > 0.90, high power LEDs, with a System Efficacy >=120 lumens/watt and junction temperature < 70°C, with ingress protection IP66, Luminaire performance complies to IS 10322 (Part 5 / Sec-5), IK05, driver surge protection 4KV, In-house additional surge protection ≥ 10KV with wide/ narrow beam optics, THD<10% at 110 Volts AC, driver efficiency >90%, , CCT: 3000K - 5700K, as approved by VPA, minimum CRI>70, etc., complete with earth connection and not less than two years warranty. Make: Philips / Crompton / Bajaj / Jaquar / Havells / Note :- 50% shall be delivered to VPA store immediately after issue of work order within a period of 45 days to use the same as per site requirement by engineer-in-charge, Balance shall be arranged in the 1st month of 2nd year of AMC or as directed by engineer-in-charge. Note :- The fitting should have type certificate (including photometry, protection against electric shock, endurance and thermal test) from Central Govt. Lab / NABL accredited lab in compliance to applicable Indian Standard. Shall be submitted along with delivery . | 200 | Nos | - | - |
| 1.04 | Supply of 120 Watt Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), Fixture shall be of relevant BIS standard complete in all respect System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. Make: Philips / Crompton / Bajaj / Jaquar / Havells Note :- 50% shall be delivered to VPA store immediately after issue of work order within a period of 45 days to use the same as per site requirement by engineer-in-charge, Balance shall be arranged in the 1st month of 2nd year of AMC or as directed by engineer-in-charge. Note :- The fitting should have type certificate (including photometry, protection against electric shock, endurance and thermal test) from Central Govt. Lab / NABL accredited lab in compliance to applicable Indian Standard. Shall be submitted along with delivery. | 200 | Nos | - | - |
| 1.05 | Supply of EV / Diesel Jeep (4 + 1 ) 5 seater capacity (Dual cabin), 4 wheeler Vehicle of model 2025 or later with carrying space at rear side, for transporting workmen & materials round the clock with driver (Permissible mileage per month: 3000 km) irrespective of any Sunday or holiday for the purpose of O&M of the industrial lighting. NOTE: Cost of fuel will be reimbursed by VPA at 10km per liter basis. Note :- The vehicle at Sl no 5 shall be arranged immediately while commencement of work order. In case of delay an alternate vehicle shall be arranged immediately to cope up the work | 24 | Months | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.00 MB
BOQ_338157.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .