| 1 | 1st₹5.1 LAccepted-AOC GANDHI CHOWK LANSDOWNE 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | ₹5.1 L Quoted ₹5.3 L | 1st | Accepted-AOC L1 |
| 2 | 2nd₹5.4 L+₹10,860 (2.05%)Rejected-AOC GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL PIN 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | ₹5.4 L+₹10,860 (2.05%) | 2nd | Rejected-AOC L2 |
| 3 | 3rd₹6.5 L+₹1.2 L (22.1%)Rejected-AOC 0 AJAY KUMAR 85 HASTAM HASTAM BANDA UTTAR PRADESH 210001 HASTAM BANDA UTTAR PRADESH 210001 UDYAM UP 13 0007628 | BANDA | UTTAR PRADESH | 210001 | ₹6.5 L+₹1.2 L (22.1%) | 3rd | Rejected-AOC L3 |
| 4 | 4th₹8.0 L+₹2.7 L (50.8%)Rejected-AOC P O BALASAUR ROAD KOTDWAR OPP PRINCE WEDDING POINT DISTT PAURI GARHWAL KOTDWAR UTTARAKHAND 246149 | PAURI GARHWAL | UTTARAKHAND | 246149 | ₹8.0 L+₹2.7 L (50.8%) | 4th | Rejected-AOC L4 |
| 5 | 5th₹9.3 L+₹4.0 L (75.1%)Rejected-AOC 5D 32B GALI NO 8 VISHNU GARDEN TILAK NAGAR WEST DELHI 110018 | DELHI | WEST DELHI | DELHI | 110018 | ₹9.3 L+₹4.0 L (75.1%) | 5th | Rejected-AOC L5 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
14 Apr 2025, 6:00 pmClosed
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
REPAIR REPLACEMENT OF WATER TANKS, FLOAT VALVE, WATER TANK LID AND CLEANING OF TANK AT LANSDOWNE.
2025_MES_701542_1
9021/E8
Open Tender
Civil Works
Item Rate
150 days
AGE I Lansdowne
All as per NIT and Tender Documents
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹20,000
Yes
12 Jun 2025
17 Mar 2025
16 Apr 2025
18 Mar 2025
14 Apr 2025
1 Apr 2025
Amount
Disconnecting existing tanks n exc 500 ltr capacity, setting aside or lowering if required for repairs , cleaning etc and hoisting if required reconnecting and refixing in position complete all as specified and directed.
Disconnecting existing tanks exc 500 ltr but n exc 1000 ltr capacity, setting aside or lowering if required for repairs , cleaning etc and hoisting reconnecting and refixing in position complete all as specified and directed.
Cleaning of service tank using bleaching powder by manually and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc n exc 500 ltr capacity complete all as specified and directed. Note:- Including date of cleaning have to be mentioned on tank.
Cleaning of service tank using bleaching powder by manually and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc exc 500 ltr but n exc 1000 ltr capacity complete all as specified and directed. Note:- Including date of cleaning have to be mentioned on tank.
Dismantling of water tanks exc 250 ltr and not exc 500 ltr capacity complete all as specified and directed.
Dismantling of water tanks exc 500 ltr and not exc 1000 ltr capacity complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks 500 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position including PVC float valve all as specified in SSR Part-1 complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position including PVC Float valve all as specified in SSR Part-1 complete all as specified and directed.
S & F in rep PVC tank cover suitable for 500/1000 ltr capacity incl necessary locking device complete all as specified and directed. Note:- Tank covers should be spiked on top and of any size fixed to the tank.
Taking up or down 15 mm bore Gl tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down Gl tubing and connections, including cleaning for refixing or removal to store 20 mm bore complete all as specified and directed.
Refixing old 15 mm bore Gl tubing and connectionsin new or old position (walls , ceiling , floor etc ) complete all as specified and directed.
Refixing old 20 mm bore steel tubing and connectionsin new or old position (walls , ceiling , floor etc ) complete all as specified and directed.
S & F 15 mm bore Galvanized Steel tubes, medium grade fixed to walls and ceilings or laid in floors complete all as specified and directed.
S & F 20 mm bore Galvanized Steel tubes, medium grade fixed to walls and ceilings or laid in floors complete all as specified and directed.
S & F in rep PVC ball cock, 20 mm bore high pressure of PTMT appoxy coating aluminium rod , with polythene float and flynut complete, Min wt =210 gm, screwed for iron pipe or bress ferrule and fixed complete all as specified and directed.
S & F in rep PVC ball cock, 25 mm bore high pressure of PTMT appoxy coating aluminium rod , with polythene float and flynut complete, Min wt =210 gm, screwed for iron pipe or bress ferrule and fixed complete all as specified and directed.
S & F in rep Gun metal globe 15mm bore or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F in rep Gun metal globe 20mm bore or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Demolition of Cement Concrete of any description in any position not otherwise specifically provided for complete all as specified and directed.
M & L 100 mm thick PCC (1:2:4) type B-2 using 20mm graged stone agg as in base of PVC service tank finish top surface even and fair using extra cement incl cleaning the surface complete all as specified and directed.
S & F in rep 15 mm bore chromium plated fancy pillar taps, cast copper alloy, with captan head screwed down high pressure with or with out lettred Hot or Cold with long screwed shanks and fly nut screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in rep 15 mm bore CP brass angle valve, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed for iron pipe complete all as specified and directed.
S & F in rep bib tap 15 mm dia cast copper alloy CP with crutch or butter fly handle screwd for iron pipe or for brass ferrule and fixed complete all as specified and directed.
M & L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exc 10 cm girth complete all as specified and directed.
S & F in repairs vitreous china squatting pan "orissa pattern" size 580X 440 mm white with integral foot rest (excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including PVC cover complete all as specified and directed.
S&F in repair PVC valve less syphonic action type flushing cistern 10ltr capacity low level, white/coloured with inlet ball valve flaot and handle including bracket and fixing of PVC flush pipe 32 mm dia and PVC connection pipes complete all as specified and directed.
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
Supply only flush pipe of polythene of low or high density 32 mm PVC for low level flushing cistern complete all as specified.
Supply and fixing fency type soap dish, chromium plated brass complete all as specified and directed.
S&F as in repair stainless steel kitchen plate rack of size 24x36x10 inch of minimum thickness 0.8mm including necessary drilling, fixing with screw, plugs in kitchen etc complete all as specified and directed.
S & F in repair PVC connections for hot and cold water 450x15 mm size with CP check nut and washers complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
S & F glazed ceramic coloured tiles of size 450mmx300mmx 8 to 9mm thick on vertical surface such as skirting, dados, risers to steps etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick cement plaster in CM (1:4) all as specified and directed by Engineer-in-charge. Tiles shall be confirming to IS-15622-2017, Group B III with average water absorption between 10% to 15% length, width and strightness of sides +0.20% (Max deviation) Thickness + 4.0% (Max deviation) straightness of sides and rectangularity +0.15% (Max deviation) surface flatness +0.22% (max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note :- Shade of the tiles including colour, design and pattern shall be approved by AGE (I)
M & LNon - skid colored Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Demolition Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for Brick work with sub-class `B' bricks, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for Rendering 15 mm thick in two layers i.e. 10mm thick in CM 1:6 and 5mm thick in CM 1:4 using water proofing liquid compound as per manufacturer's instructions on other than fair faces brick or concrete surfaces and finishing surfaces even & fair complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately.
Preparation of new un plastered surfaces of walls applying two coats of cement base paint over a coat of cement base primer complete all as specified and as directed.
S&F 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints and laid in trenches or in floor of following size complete all as specified and as directed.
S&F 110 mm PVC (SWR) bends pipes single socketed in any length with rubber ring joints and laid in trenches or in floor of following size complete all as specified and as directed.
S&F 110 mmPVC (SWR) junction single, (Single T) equal or unequal with rubber ring joints and laid in trenches or in floor of following size complete all as specified and as directed.
PIONEER REFRIGERATION AND ELECTRICALS (BID ID -3281242)
AJAY KUMAR CONTRACTOR (BID ID -3277841)
sunshine engineering (BID ID -3281177)
ANANYA CONSTRUCTION CO. (BID ID -3281779)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .