| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 0 BAROO BAROO KARGIL KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
14 Mar 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Mech Div Kargil
Office of Executive Engineer Mech Div Kargil
Replacement of Rising main of Lift irrigation Scheme Yokma Akchamal.
2024_PWD_12708_1
MDK/e-NIT/76 of 2023-24
Open Tender
Pipe Laying Works
Turn-key
60 days
LIS Yokma Akchamal
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,100
EXECUTIVE ENGINEER MECHANICAL DIVISION KARGIL
₹50,000
Yes
14 Mar 2024
12 Mar 2024
14 Mar 2024
12 Mar 2024
14 Mar 2024
12 Mar 2024
Amount
Replacement of rising main of the lift irrigation scheme upto 600 meters from pump house by way of dismantling existing pipe section and p/fixing of new pipeline with required number of NRVs and thermal expansion loops. Job includes road crossing at NH and L/R Pump house makegood of the damages incurred.
P/Fixing of MS pipe confirming to IS: 1239/ 3589- fitted with flanges min 12 mm thickness. Job includes, providing of carbon steel nuts & bolts with washer, and 3mm corksheet gasket of flange size (best suited for high pressure leak proof joints), long radius bends, reducers required as per site conditions. Job also includes earthwork, excavation and refilling (wherever required). 1. Type : MS ERW Pipe 2. Nominal Bore Size = DN150 mm (6") 3. Wall Thickness : > 7mm 4. Acceptable make: Jindal/Surya
Design supply installation testing and commissioning of ISI marked HDPE pipe (flanged) as per IS 4984:2016 to correct alignment and gradients, cutting , jointing with all fittings, ISI marked couplings, tees, bends reducers, etc including earthwork complete in all respect.
160 mm, DN 6”, PN 16, PE-100, SDR-9
Supply of 150 MM Non Return valve, PN25, Conforming to BS 5153 (EN 12334) / IS 5312 Part 1 & 2, BS 5160/DIN 2401 and latest Acceptable make: Kirloskar/sant/zoloto/VAG
Supply of 150 MM Non Return valve, PN16, Conforming to BS 5153 (EN 12334) / IS 5312 Part 1 & 2, BS 5160/DIN 2401 and latest Acceptable make: Kirloskar/sant/zoloto/VAG
Anchor Blocks Construction of PCC Anchor block using (1:2:4)mix at required points. Job includes cost of material, labour, shuttering, tools and tackles etc. The job also includes fixing of 02 Nos. 6mm ms strip with suitable anchor bolts & nuts to fasten the Pipe on the anchor block. Block size = 2’8”x2’8”x4’ = 0.808Cum For 06 blocks = 0.808x6 = 4.85cum
Dismantling of existing raising main of 600 meters length from pump house and its transportation and safe storage division store
M/S Zakir Hussain
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .