Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 10 640 KP BUILDING CHIRAYIL KONDOTTY MALAPPURAM KERALA 673638 | MALAPPURAM | KERALA | 673638 | Accepted-Technical Accepted after technical evaluation |
| 2 | Accepted-Technical 5 3205F 1ST FLOOR RAJEEVARI ARCADE UKS ROAD KOZHIKODE 673 001 | KOZHIKODE | KOZHIKODE | KERALA | 673001 | Accepted-Technical Accepted after technical evaluation |
Tender Value
₹16.9 L
EMD Value
₹42,370
Closing Date
21 Mar 2026, 3:00 pmClosed
Executive Engineer,Electronics Division,Thrissur
Executive Engineer, PWD Electronics Division, Thrissur - 20
DEPOSIT-Supply and installation of LAN and telephone cabling in the workstations in Accounts(G1 ,G2,G3) and IT (Admin, E Courts ,Digitization) in High Court of Kerala-LAN and telephone cabling-General Electronics Wor
2026_PWD_847046_1
PWD/BLDG/TR/1943/2026_7_1_1/1
Open Tender
Miscellaneous Works
Item Rate
240 days
High Court Eranakulam
Please refer Tender documents.
12 documents required · 12 mandatory
₹2,760
₹42,370
17 Apr 2026
12 Mar 2026
23 Mar 2026
12 Mar 2026
21 Mar 2026
12 Mar 2026
LAN in work stations in sections at High Court of Kerala
OD296948/2025-2026:Supply and installation of 48port Access Switch with minimum 48x GE RJ45 and 4x 10GE SFP+ ports. Switching throughput - 176 Gbps, Forwarding Capacity - 262 Mpps, 32K MAC Address, IPv4 and IPv6 static routing. RIPv1/v2, RIPng, OSPFv2/v3 Should support IEEE 802.3ad Link Aggregation with LACP,Link Aggregation Group Size 8, Should support virtual wire between two ports for troubleshooting,should support Static L3 hardware-based routing ,Switch should support IP conflict detection and notification,should support LLDP, should support Storm Control, LoopGuard,LLDP-MED, MCLAG(Multi-chassis link aggregation.Switch should support Device Detection to understand the type of device operating systems, display the IP address.,Should support centralized security management, configuration and reporting through a single console from existing switch controller or from external NMS RIPv1/v2, RIPng, OSPFv2/v3, Certification FCC, CE, RCM, VCCI, BSMI, UL, CB, RoHS2. Maf to be attached. Preferred Make : Juniper,HP,Fortinet
OD292572/2025-2026:Supply and installation of 24 port Access Switch with minimum 24x GE RJ45 and 4x 10GE SFP+ ports. Switching throughput - 128 Gbps, Forwarding Capacity - 190 Mpps, 16K MAC Address, 1GB DDR4,256MB flash,redundant AC power supply,IPv4 and IPv6 static routing. RIPv1/v2, RIPng, OSPFv2/v3 Should support IEEE 802.3ad Link Aggregation with LACP,Link Aggregation Group Size 8, Should support virtual wire between two ports for troubleshooting,should support Static L3 hardware-based routing ,Switch should support IP conflict detection and notification,should support LLDP, should support Storm Control, LoopGuard,LLDP-MED, MCLAG(Multi-chassis link aggregation.Switch should support Device Detection to understand the type of device operating systems, display the IP address.,Should support centralized security management, configuration and reporting through a single console from existing switch controller or from external NMS RIPv1/v2, RIPng, OSPFv2/v3, Certification FCC, CE, RCM, VCCI, BSMI, UL, CB, RoHS2. MAF to be attached Preferred Make : Juniper,HP,Fortinet
OD292576/2025-2026: Supply and installation of UL listed ETL 4 channel verified 1U rack mountable 24 port CAT-6 fully loaded patch panel with individually removable RJ45 &RJ11 compatible jacks.contact plating:1.27micrometers Au/Ni rear cable organizer,pannel should be made of cold rolled steel,powder coated ,front labelling facility required .operating life: Min.750 insetion cycles,Durability:Min. 200reterminations,dust covers to protects from dust&contaminants ,Material: Black powder coated CRS.Thickness :Min.1.52mm,front &rear port labelling as well as panel identification label-RoHS compliant including termination charges. Preferred Make: Actassi, Belden, Molex, Panduit, R and M, Commscope
OD292574/2025-2026: Supply, Installation, Testing and Commissioning of 24 Port fully loaded 1U Rack mountable LIU(Swing Type)with Splice tray ,pigtails and cable management. Preferred Make: Belden, ,Molex, R and M, Commscope
OD299062/2025-2026:Supply, installation , Testing and commissioning of 12 Port fully loaded 1U Rack mountable LIU with Splice tray ,pigtails and cable management. Preferred Make: Belden, ,Molex, R and M, Commscope
OD292579/2025-2026:Supply ,termination ,testing and commissioning of UL listed ETL 4 channel verified Information Outlet with CAT-6 keystone jack with dust protection,suitable for 22-24AWG bare copper conductor,contact plating: 5micron gold/Nickel as per TIA/EIA 568-B colour code confirming to the standards ANSI/TIA-568.2D,ISO/IEC 11801,IEEE 802.3,ISO/IEC 60332,UL94V-0 rated or equivalent,Min. 500 insertion cycles and 100 reterminations and RoHS compliant. Preferred make: Molex/ Legrand / Actassi / Belden /R and M/ Commscope
OD298546/2025-2026:Supply, fixing, testing certification and documentation of spring shutter front access single ABS Faceplate withRJ 45 Module .(Delta Certified) Preferred Make:Molex/ Legrand / Actassi / Belden /R and M/ Commscope
OD292586/2025-2026:Supply ,termination ,testing and commissioning of UL listed ETL 4 channel verified 1 Mtr CAT-6 (LSZH) Giga UTP patch cord having LSZH jacket,24AWG bare copper conductor UTP 4pair both end factory crimped with modular male plugs with min.500 insertion cycles terminated as per TIA/EIA 568-B colour code confirming to the standards ANSI/TIA-568.2,ISO/IEC 11801,IEEE 802.3,ISO/IEC 60332-1 and RoHS compliant. Preferred make: Molex/ Legrand / Actassi / Belden /R and M/ Commscope
OD299061/2025-2026:Supply and providing 2 Mtr CAT-6 (LSZH) Giga UTP patch cord. Preferred make: Molex/ Legrand / Actassi / Belden /R and M/ Commscope
OD299060/2025-2026:Supply, laying, testing (OTDR), certification and documentation of Single mode 6 core armored OS2 type outdoor fiber cable ,unitube,single sheathed,corrugated steel tape ,UV stabilised,polyethelene outer anti-termite and anti rodent, water blocking, gelly filled cable through conduit. Prefered Make : Molex/ Finolex/Commscope
OD299059/2025-2026:Supply and Installation of Fiber SM patch cord with LC-SC connectors and 1 meter length. Approved Make: Molex/ Legrand / Actassi / Belden /R and M/ Commscope
OD299111/2025-2026:Supply and installation of 10 G base single mode Optical Transceiver SFP+ module with minimum reach of 10 KM, same OEM as switch.
OD292580/2025-2026:Supply and fixing of 19 inch 15U (600mmx 650mm) rack with covered wire manager, cooling fan(2Nos), 2XAC distribution box, with side open and all other accessories. Make:- Rittal/Valrack/Netrack
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
OD298545/2025-2026:Charges for floor/wall cutting ,plastering and finishing the surface after laying cables through conduit
OD298629/2025-2026:Charges for dismantling existing unwanted cables , Information Outlets and conduits in the proposed rooms
OD336854/2025-2026:Supplying and drawing of UTP 4 pair CAT 6 LAN cable with LSZH sheath and minimum 23AWG copper conductor in the existing surface/recessed steel/PVC conduit as required3 run of Cable Preferred Make: Molex,Commscope,R and M,Panduit
OD336855/2025-2026:Supplying and drawing of UTP 4 pair CAT 6 LAN cable with LSZH sheath and minimum 23AWG copper conductor in the existing surface/recessed steel/PVC conduit as required2 run of Cable Preferred Make: Molex, Commscope, R and M, Panduit
OD336856/2025-2026:Supplying and drawing of UTP 4 pair CAT 6 LAN cable with LSZH sheath and minimum 23 AWG copper conductor in the existing surface/recessed steel/PVC conduit as required1 run of Cable Preferred Make: Molex, Commscope, R and M, Panduit
Telephone cabling
OD296946/2025-2026:Supply, installation and testing of 20 pair Telephone Junction Box with KRONE connecting modules in a suitable M.S enclosure with Powder Coated paint of approved colour and lock and key arrangement on wall with suitable fixing arrangement and making necessary connections. Preffered Make: Krone
OD296947/2025-2026:Supply, installation, testing and commissioning of RJ 11 information outlet in good quality with shutter arrangement in front plate on recess/ surface metal/PVC mounting box . Preferred Make: Molex, Legrand
1.18.2:Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
Installation of temporary LAN and telephone cabling to occupy the shifted sections(G3,G1,IT admin cell,Digitization )in connection with the installation of work station/cubicles.
OD297109/2025-2026:Labour charges for temporary arrangement of network connection and telephone cabling to accomodate the shifted sections(G3,G1,IT admin cell,E Courts,Digitization )in connection with the installation of work station/cubicles.
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1431233.xls
BOQ • 0.25 MB
NIT.pdf
Tender Documents • 0.02 MB
SBD.pdf
Tender Documents • 1.63 MB
MakeandModel.pdf
Tender Documents • 0.32 MB
AMC.pdf
Tender Documents • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .