Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC LOWEST REASONABLE BID | |
| 2 | L2₹39.8 L+₹8.9 L (28.7%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹46.3 L+₹15.4 L (49.7%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹47.5 L+₹16.6 L (53.8%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Eligible as Not enlisted in requisite cat. b (i) |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
22 Mar 2023, 6:00 pmClosed
CWE ARMY JODHPUR
CWE ARMY MULTAN LINE ARMY AREA JODHPUR-342010
REPAIR/ MAINT OF CEILING FAN, EXHAUST FANS AND WALL MOUNTING FANS AND REPAIR/REWIRING AND REPLACEMENT OF OLD ALUMINIUM/COPPER POINT WIRING AND MISC FITTINGS AND FIXTURES IN AREA OF AGE B/R - I UNDER GE (ARMY) NO. 1 JODHPUR
2023_MES_583077_1
82223/102/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY NO. 01
₹1 L
Yes
19 May 2023
25 Feb 2023
24 Mar 2023
25 Feb 2023
22 Mar 2023
15 Mar 2023
27 Feb 2023 - 14 Mar 2023
Amount
M&L for dismantling and removing old burnt out copper winding wire of ceiling fans of size 1200 mm (48”) sweep of any make and rewinding with new super enameled copper winding wire of existing gauge as per old copper winding pattern and design to give same performance as per original fan's make including providing insulating media, varnishing (Golden), Cleaning, Oiling, Greasing etc and refixing all the parts complete and testing in E/M Store yard to the entire satisfaction of Engr-in-Charge.
All as per item No 1 here in before but Exhaust Fans of size 9" (225 mm ) Sweep
All as per item No 1 here in before but Exhaust Fans of size 12" (300 mm ) Sweep
All as per item No 1 here in before but Exhaust Fans of size 15”/16” ( 375 / 400 mm ) Sweep
All as per Item No 1 here in before but Exhaust Fans of Size 18” (450 mm) Sweep
All as per item No. 1 here in before, but for WALL MOUNTED fan along with replacement of oscillating mechanism and regulator complete suitable for wall mounting fan and support hud assembly of size - 16"/18" etc., complete all as specified and directed.
All as per item No.1 here in before, but for heavy duty AIR CIRCULATING fan of size - 600 mm ( 24" ), 1400 RPM, including replacement of bush / bearing of approved make, along with replacement of oscillating mechanism and regulator all as directed and refixing at location in unit line of Army area . NOTE:-(i) For Ser Item No 1.01 to 1.07 The super enamelled winding wire is to provided with make and appropriate gauge as approved by EIC. (ii) Any un-serviceable part required for replacement shall be measured and paid separately under respective item of schedule 'A'. (iii) Ceiling Fans/Exhaust Fans for rewinding/overhauling shall be carried out in E/M yard only.
Hanging only ceiling fan repaired or new any size and connecting up to the ceiling rose including taking down old unserviceable fan (Note:- If ceiling fan fell down any cause contractor will responsible for this accident
Fixing only exhaust fan of any size / make at MD/OTM Accn in unit lines of Army Area and connecting up to the ceiling rose including taking down old unserviceable fan
Supply only of ball bearing suitable for Ceiling/Exhaust Fans of following sizes complete all as specified and directed by Engineer-In-Charge: -
Ball bearing SKF/NBC/TATA – 6201
Ball bearing SKF/NBC/TATA – 6202
Ball bearing SKF/NBC/TATA – 6203
S&F capacitor of 2.5 MFD oil filled insulated with aluminium body after removing unserviceable condenser complete all as specified and directed.
All as per Item No 11 hear in before but of 4.00 MFD.
S&F in replacement of gun metal bushes of suitable size for ceiling fans (any type/any sweep) including taking down old unserviceable one complete all as directed .
S&F in replacement of 'Ú' clamp with rubber reel of standard quality including nut/bolt, lock nut and pin suitable for ceiling fans (any type/sweep) including taking down old unserviceable one complete all as specified and directed.
S&F in replacement of PVC canopy upper/lower side of standard/ good quality including bolt with nut, lock nut and pin suitable for ceiling fans (any type/ any sweep and make) including taking down old unserviceable one complete all as specified and directed.
S&F in replacement of down rod 90 cm long of 15 mm dia " heavy duty " thread type GI pipe complete with rubber bush, centre bolt , nut , lock nut ,"U" clamp suitable for thread ends connection with cotter pin including taking down old unserviceable one complete all as specified and directed.
S&F in replacement of down rod 90 cm long of 12 mm dia " made out of high density mild steel including drilling hole for split pin including taking down old unserviceable one complete all as specified and directed.
S&F in replacement of down rod 60 cm long of 12 mm dia " made out of high density mild steel including drilling hole for split pin including taking down old unserviceable one complete all as specified and directed.
S&F in replacement of down rod 30 cm long of 12 mm dia " made out of high density mild steel including drilling hole for split pin including taking down old unserviceable one complete all as specified and directed.
S&F MS U-type Hook hanger with 10x75mm Fasteners (double fasteners) complete with nuts, bolts and washers for hanging Ceiling fans complete all as specified and as directed.
S&F GI pipe medium grade 40mm dia for hanging Ceiling fan any size including cutting as per site requirement and grouting with cement concrete in both ends on existing brick/stone wall complete all as specified and directed.
M&L for making hole in existing brick / stone wall of any thickness for fixing exhaust/ ventilation fan complete all as specified and directed.
S&F in replacement of fan blade as per existing including fixing screws suitable for ceiling fans 1200 mm sweep (any type/ make) including taking down old unserviceable one complete all as specified and directed .
S&F in replacement of fan blade as per existing including fixing screws suitable up to 300 mm sweep exhaust fans (any type/ any make) including taking down old unserviceable one complete all as specified and directed .
S&F in replacement of fan blade as per existing including fixing screws suitable for exhaust fans 375/400 mm sweep (any type/any make) including taking down old unserviceable one complete all as specified and directed .
S&F in replacement of fan blade as per existing including fixing screws suitable for exhaust fans 450 mm sweep (any type/ make) including taking down old unserviceable one complete all as specified and directed .
S&F in replacement of bracket with frame as per existing including fixing screws suitable up to 300 mm sweep exhaust fans including taking down old unserviceable one complete all as specified and directed.
S&F in replacement of bracket with frame as per existing including fixing screws suitable for exhaust fans 375/400 mm sweep including taking down old unserviceable one complete all as specified and directed.
S&F in replacement of bracket with frame as per existing including fixing screws suitable for exhaust fans 450 mm sweep including taking down old unserviceable one complete all as specified and directed.
M&L for painting of ceiling fan size - 1200 mm sweep complete with down rod and blades, cleaning , removing dirt / dust, scrapping out old paint, applying putty and painting with synthetic enamel paint first quality of approved make including writing MES No. in figure & words 25 mm wide with synthetic enamel paint of black colour on ceiling fans complete all as specified & directed. Note :- The work is to be carried out in E/M store yard to the entire satisfaction of Engr-in-Charge )
All as per item No 30 here in before but Exhaust Fans of size (225 mm,300mm,375mm,400mm & 450) Sweep
S&F for pvc stand for capacitor including connection etc. complete all as specified & directed
S&F louver made of MS sheet 3 mm thick for exhaust fan of any sizes complete all as specified and as directed.
M&L for connecting PVC insulated three core copper conductor multistranded, unsheated cable of size 23/0.0076 from fan and up to the ceiling rose (Length of cable 0.60 RM approx for each job).
Taking down copper/aluminium point wiring surface/ concealed (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell etc. removing materials from site of work complete or removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc.
M&L for point wiring complete with 1.5 sqmm single core multi stranded copper conductor PVC (FRLSH) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked passing in and including PVC Casing & Capping 25/35mm as per existing site conditions with accessories fixed on surface of wall / roof / ceiling etc in sunken pressed steel terminal boxes in wall, including 3.00 mm thick plastic laminated hylem sheet and 1.50 sq mm PVC insulated unsheathed stranded copper conductor(FRLSH) cable for common earth and connecting to earth dolly for the following points:-
One light point controlled by one, one way switch
One light/ fan point controlled by one, one way switch
One socket outlet 3 pin 5/6 Amps on same board
One socket outlet 3 pin 5/6 Amp on independent board
One bell point controlled by one bell push
One two way point controlled by two, two way switch
All as per item No 36 above but with using 2.5 Sq mm single core multistanded copper conductor cable and 2.5 sq mm PVC insulated unsheathed stranded copper conductor for common earth wire for 6 pin 16 Amp socket outlet on independent board
M&L for concealed point wiring complete with multistranded copper conductor 1.5 Sqmm PVC insulated unsheathed single core FRLSH cable 1100 volt grade, confirming IS 694 & colour code in conduit system of wiring, drawn through in and including non-metallic PVC concealed (including Cutting Chases and make good the disturbed surfaces ) conduit of size not less than 20 mm and conduit accessories, totally concealed in walls surfaces, floors, ceiling and sunk terminal boxes of CI or 16 SWG pressed steel housing, totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk / cup washers, for mounting of switches, sockets fan regulators etc including 1.5 Sqmm FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, all as specified, directed and shown on drgs for The rates of chase cutting on wall done concealed conduit and steel terminal boxes are included in the unit rates all as specified and directed by Engr-in-Charge For following:- (Note- Rates of chasing/cutting & making goods shall be included in the unit rate)
One light point controlled by one-one way switch.
One ceiling fan/Exhaust fan point controlled by one way switch.
One three pin 5/6 Amp socket on independent board controlled by one no 5 Amp switch
One three pin 5/6 Amp socket on same board controlled by one no 5 Amp switch
One bell point controlled by one bell push
One light point controlled by two, two way switch
All as per item No 38 above but with using 2.5 Sq mm single core multistanded copper conductor cable and 2.5 sq mm PVC insulated unsheathed stranded copper conductor for common earth wire for 6 pin 16 Amp socket outlet on independent board
M&L for point wiring complete with 1.5 sqmm single core multi stranded copper conductor PVC (FRLSH) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked passing in existing PVC/ steel conduit fixed on surface of wall / roof / ceiling or concealed etc in sunken pressed steel terminal boxes in wall, including 3.00 mm thick plastic laminated hylem sheet and 1.50 sq mm PVC insulated unsheathed stranded copper conductor (FRLSH) cable for common earth and connecting to earth dolly for the following points:-
One light point controlled by one, one way switch
One light/ fan point controlled by one, one way switch
One socket outlet 3 pin 5/6 Amps on same board
One socket outlet 3 pin 5/6 Amp on independent board
One bell point controlled by one bell push
One two way point controlled by two, two way switch
All as per item No 40 above but with using 2.5 Sq mm single core multistanded copper conductor cable and 2.5 sq mm PVC insulated unsheathed stranded copper conductor for common earth wire for 6 pin 16 Amp socket outlet on independent board
M&L for Point wiring (Modular Concealed) using approved colour coding as per IS Red/Yellow/Blue, Black and green for single phase circuits) with multi stranded copper conductor 1.5 Sqmm nominal cross area single core PVC insulated and unsheathed FRLSH cable 1100 Volts grade ISI 694 marked with valid CML No. in and including medium grade PVC concealed conduit of dia not less than 20mm and conduit accessories ISI marked with valid CML No. ( IS 9537 -1983 for wall/roof /floor etc with pressed flush metal boxes covered with inner plates & outer plates etc suitable for mounting of Modular switches & sockets including PVC insulated multi stranded copper conductor FRLS 1.5 sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following points:-
One light point controlled by one, one way switch
One light/ fan point controlled by one, one way switch
One socket outlet 3 pin 5/6 Amps on same board
One socket outlet 3 pin 5/6 Amp on independent board
One bell point controlled by one bell push
All as per item No 42 above but with using 2.5 Sq mm single core multistanded copper conductor cable and 2.5 sq mm PVC insulated unsheathed stranded copper conductor for common earth wire for 6 pin 16 Amp socket outlet on independent board
S&F switch piano, flush type, single pole, one way, 6 Amp, ISI Marked complete all as specified and directed by Engineer-in-charge
S&F in replacement switch piano, flush type, single pole, one way, 6 Amp, ISI Marked including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge
S&F switch piano, flush type, single pole, two way, 6 Amp, ISI Marked complete all as specified and directed by Engineer-in-charge
S&F in replacement switch piano, flush type, single pole, two way, 6 Amp, ISI Marked including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge
S&F switch piano, flush type, single pole, one way,16 Amp ISI Marked complete all as specified and directed by Engineer-in-charge
S&F in replacement switch piano, flush type, single pole, one way, 16 Amp, ISI Marked including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge
S&F bell push, piano flush type, 5 Amp ISI Marked. complete all as specified and directed by Engineer-in-charge
S&F in replacement bell push, piano flush type, 5 Amp ISI Marked including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge
S&F socket outlet, 3/5 pin, 6 Amp , flush type, ISI Marked. complete all as specified and directed by Engineer-in-charge
S&F in replacement socket outlet, 3/5 pin, 6 Amp , flush type, ISI Marked including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge
S&F socket outlet, 3/6 pin, 6 and 16 amp, flush type, ISI Marked complete all as specified and directed by Engineer-in-charge
S&F in replacement socket outlet, 3/6 pin, 6 and 16 amp, flush type, ISI Marked including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge
S&F in repairs bell Ding Dong, AC 230 volts, single pole including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge
S&F fan regulator electronic / socket type complete all as specified and directed by Engineer-in-charge
S&F in replacement Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge
S&F in replacement capacitor of 2.5 MFD for ceiling fan including taking down old unserviceable one complete all as specified and directed.
S&F in replacement ceiling rose 3 terminals including taking down old unserviceable one complete all as specified and directed.
S&F in replacement Modular switch any type and make 6 amp one way 230 V including taking down old unserviceable one of any make all as specified & directed .
S&F in replacement Modular switch any type and make 16 amp one way 230 V including taking down old unserviceable one complete all as specified and directed.
S&F in replacement Modular socket Any Type and make, 6 amp 5 Pin one way 230 V including taking down old unserviceable one complete all as specified and directed.
S&F in replacement Modular socket Any Type and make, 16 amp 5 Pin one way 230 V including taking down old unserviceable one complete all as specified and directed.
S&F in replacement Modular switch any type and make 6 amp two way 230 V including taking down old unserviceable one complete all as specified and directed.
S&F in replacement Modular fan Regulator step type and make, 100 watt, 230 Volts including taking down old unserviceable one complete all as specified and directed.
S&F in replacement Modular Bell push any type and make 6 amp one way 230 V including taking down old unserviceable one complete all as specified and directed.
S&F in replacement modular cover plate with frame 3 module type for fixing of modular switch socket, regulators, blank plates etc including taking down old unserviceable one complete all as specified and directed.
S&F in replacement modular cover plate with frame 8 module type for fixing of modular switch socket, regulators, blank plates etc including taking down old unserviceable one complete all as specified and directed.
S&F in replacement modular cover plate with frame 12 module type for fixing of modular switch socket, regulators, blank plates etc including taking down old unserviceable one complete all as specified and directed.
S&F in replacement PVC conduit including fitting such as tee, elbow, bend etc 20mm dia ISI (MMS) grade, including taking down old unserviceable one complete all as specified and directed.
S&F in replacement PVC casing Capping tee, elbow, bend etc 20/25 mm dia ISI (MMS) including taking down old unserviceable one complete all as specified and directed.
S&F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-42 DB's suitable for one MCB SPN as incoming and 2 MCB SP as out going, SPN 4Way complete including taking down old unserviceable one complete all as specified and directed.
S&F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one MCB SPN as incoming and 6 MCB SP as out going SPN 8 way complete including taking down old unserviceable one complete all as specified and directed.
S&F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one MCB SPN as incoming and 10 MCB SP as out going SPN 12 way including taking down old unserviceable one complete all as specified and directed.
S&F in replacement sheet metal enclosures 415 volt TPN 4 way with 200 Amp rated bus bar, double door IP-43 DB's suitable for one No 63 to 100 Amp 10 KA TPN MCCB as incoming including taking down old unserviceable one complete all as specified and directed.
S&F in replacement MCB SP "C" series 5-32 Amps ISI marked including taking down old unserviceable one complete all as specified and directed.
S&F in replacement MCB SPN "C" series up to 63. Amps ISI marked including taking down old unserviceable one complete all as specified and directed.
S&F in replacement MCB TPN C Curve 63 Amps including taking down old unserviceable one complete all as specified and directed.
S&F in replacement electronic driver as per sample for LED fitting up to 45 watt including taking down old unserviceable one complete all as specified and directed.
Taking down bldg security light up to 45 watt and refixing the same after repair complete all as specified and directed by Engr -in-charge, (Electronic driver shall be measured paid separately)
S&F bell Ding Dong, AC 230 volts, single pole complete all as specified and directed by Engineer-in-charge
S&F in replacement 2-Watt LED Wall Light (bed light) for reading including taking down old unserveable one complete all as specified and directed
S&F in replacement round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete including taking down old unserveable one complete all as specified and directed.
S&F in replacement Spot light 6 Watts Black/ white Body LED Spot Light, Focus Light (Warm White) including taking down old unserveable one complete all as specified and directed
S&F in repair PVC insulated and unsheathed FRLSH single core multistranded copper conductor of size 1.5sqmm in existing conduit as in replacement of any defective/burnt circuit complete all as specified and as directed by Engineer in charge
S&F in repair PVC insulated and unsheathed FRLSH single core multistranded copper conductor for of size 2.5sqmm in existing conduit as in replacement of any defective/burnt circuit complete all as specified and as directed by Engineer in charge
S&F in replacement Street light bracket made out of medium grade GI Pipe, bent to shape including GI Clamps nut, bolts washers, reducer of required size for suitable any type fittings etc complete including necessary painting and taking down old unserviceable GI Bracket complete all as specified and directed
S&F LED street light fitting, 35 Watts, 230V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection including 1.60 mtr long 40mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of F1 40 mmx6mm with bolts , nuts & washers and conductor to fitting with 3 core 1.5 sqmm pvc insulated cable complete all as specified and directed
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watts, 220V, AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
S&F LED lights fitting 1x20 W, cool white, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
S&F in replacement LED lights fitting 1x20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including taking down the old unserviceable one complete all as specified and directed by Engr-in-Charge.
S&F LED decorative wall light Grace 9W, Wall Light, White all accessories pre wired and including connecting up to fitting with flexible cable of suitable size complete all as specified and as directed.
S&F LED light fitting 1x9W/1X10Wbulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. complete all as specified and as directed
S&F in replacement of GLS Coloured Lamp Red,Green,Milky,0-60 Watt, as per existing sample given by department complete all as specified and as directed
S&F in replacement of LED Bulb threaded types in holders 0 to 15 Watts, as per existing sample given by department complete all as specified and as directed
S&F in replacement of LED Bulb brown in brightness (Warm type), 0 to 15 Watts as per existing sample given by department complete all as specified and as directed
S&F in replacement of LED flood light 70 watt, 230V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant complete with driver and lamp, complete all as specified and as directed.
S&F in replacement of post top lantern LED type, 20 watt ,230V, AC outdoor type with decorative post top for 360 degree indirect light, IP 65 protection with impact and corrosion resistant complete with driver and lamp, complete all as specified and as directed.
M&L for sub main wiring with PVC insulated and unsheathed 2x6 Sq mm single core multistrandred copper conductor (FRLSH) cable and 6 Sq mm single core copper conductor cable PVC insulated and unsheathed as earth wire passing through in and including PVC conduit concealing in walls ISI marked and conduit accessories fixed on surface of wall, ceiling etc, making good the disturbed surface including taking down old unserviceable sub main wiring, complete all as specified and as directed. Note :- Two runs of cable 6 Sqmm and One run of 6 Sqmm along with conduit including taking down old wiring shall be measured as one unit length.
M&L for sub main wiring with PVC insulated and unsheathed 2x6 Sq mm single core multistrandred copper conductor (FRLSH) cable and 6 Sq mm single core copper conductor cable PVC insulated and unsheathed as earth wire passing through in and including PVC conduit fixed on surface ISI marked and conduit accessories fixed on surface of wall, ceiling etc, making good the disturbed surface including taking down old unserviceable sub main wiring, complete all as specified and as directed. Note :- Two runs of cable 6 Sqmm and One run of 6 Sqmm along with conduit including taking down old wiring shall be measured as one unit length.
S&F in replacement electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH, complete all as specified and as directed by Engineer in charge
S&F in replacement electronic meters temper proof LCD display with polycarbonate cover Three phase, 415 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH, complete all as specified and as directed by Engineer in charge
M&L for Earthing complete with galvanised steel earth plate electrode 60 x x60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion . Note : Rates are deemed to be included for necessary earth work, earth pit with RCC cover of size 300X300 x25 mm and etc complete
Surendra Singh
Shri Electrical Enterprises
naveen enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .