| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC | L1 | Accepted-AOC Accepted as L1 | |
| 2 | L2₹36.2 L+₹5.1 L (16.3%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹37.4 L+₹6.3 L (20.2%)Rejected-Finance FLAT NO 20 AMBEDKAR ROAD DEHU ROAD PUNE 412101 D 101 CESC INDEX NO D 101 HQ CESC PUNE | NA | NA | 412101 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹37.8 L+₹6.6 L (21.3%)Rejected-Finance | L4 | Rejected-Finance Rejected |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
26 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Dehu Road, Pune
GE Dehu Road, Pune,412101
SPL REPAIR TO MD ACCN AT SHIVAJI ENCLAVE BLOCK NO P 801 OF OD TALEGAON AND CERTAIN REVENUE AND MINOR WORK AT GE DEHU ROAD
2022_MES_510665_1
8610
Open Tender
Civil Works
Item Rate
180 days
GE Dehu Road, Pune
Please refer Tender documents
7 documents required · 7 mandatory
₹500
GE Dehu Road, Pune
₹90,000
Yes
21 May 2022
26 Feb 2022
2 Apr 2022
26 Feb 2022
26 Mar 2022
12 Mar 2022
60 days
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation .etc in hard/dense soil.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard dense soil all as specified.
Returning,filling in including spreading ,leveling ,waterring and well ramming in layers not exc 25cm with excaveted soil as directed.
Removing excavation material/soil n .exc. 50 m and depositing where directed at a level n. exc 1.5 m above the starting point.
Removal of excavated material exc 250mtrs but n.exc 500mtrs and depositing where directed at a level of n.exc 1.5mtrs above the starting point in soil.
M&L moorum filling in floors/pavings, laid in layers not exceeding 15cm thick, spread levelled and rammed/rolled including watering to reqd level and gradient all as specified.
M&L hardcore of gauge not exceeding 63mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface.
M&L for Cement concrete, (1:4:8) type D2 (using 40mm graded aggregate)as in foundations/filling mass concrete complete all as specified and directed
M & L for 100 mm thick Cement concrete type D-2 1:4:8 (40 mm graded aggregate) as in sub base complete all as specified and as directed.
M&L 40mm thick Damp proof course to horizontal or vertical surfaces including necessary use & waste of form work, in cement concrete 1:2:4 type B-0 (Using 12.5mm graded stone aggregate) all as specified
M&L for Brick work with subclass 'B' brick straight or curved on plan 6m mean radius built in CM (1:6) etc as directed .
M&L for precast cement concrete, type C1 (1:3:6) , (20mm graded aggregate ) masonary with solid blocks, exc , 10cm in width and setting in cement mortar (1:4) complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, base of columns and the like complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate as in columns, pillars, piers, posts and struts and the like complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate as in slabs complete all as specified and directed.
M&L RCC 1:2:4 type B1 (using 20 mm graded aggregate) as in beams cantilevers and lintels over 1.5 m span etc or similar items all as specified and directed.
M&L RCC 1:2:4 type B1 (using 20 mm graded aggregate) as in slabs supported on walls, columns, beams in floors, roof, landing, canopies and in shelves etc or similar items all as specified and directed.
M&L for 75mm thick cement concrete type C2 1:3:6 as in plinth protection complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
All as per Item No 20 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M & L for use and waste of form work to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed.
Formwork to sides of Square, rectangular on plan or polygnal pillars, posts, struts, piers, columns and stanchion rough finished flat surface of concrete complete all as specified and directed.
Formworkfor rough finished surface to sides and soffits of beam, bressummers,lintels, cantilevers and supports etc all as specified and directed.
M & L for use and waste of form work rough finished surface of concrete flat to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200 mm thick horizontal or slopping in rough finished surface of concrete complete all as specified and directed.
M&L for Use & waste of formwork for rough finished surface to edges of concrete flats, breaks in floors, window cills, concrete railings etc and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed
Taking out existing water proofing treatment including cement plaster(any no of layers) on roof surfaces, cleaning the surfaces and removing the debris outside MOD land complete all as specified and as directed.
Extra over rendering for work in isolated width such as in bands, sunk pannels, cornices, skirting sides of slabs, parapet sides and top drip moulds etc and similar work not exc 15 cm width or girth complete all as specified and directed.
M&L for water proofing treatment using polymerised membrane to roof slab including 10 mm thick plaster in cement mortar 1:4 as in roof mixing with WPC mixing with water proofing compound by 3% by weight of cement or as per manufactire instruction . Water proofing treatment shall be as under:- (a) Applying cold bitumenous oil based primer IS No 3383 @ 250 Gms/Sqm and laying APP Modified membrane with non woven polymer reinforcement / mat core (Centre core) not less than 3 mm thick and not less than 3.50 kg/sqm the overlap shall be 100 mm on length side and 100 mm on width side and all as per manufacturer instruction complete.The roof surface shall be thoroughly wire brushed, washed, dried up & cleaned to remove all foreign materials & dust to receive primer.Top surface shall be applied with 0.15 Kg/Sqm bitumenous aluminium paint.
Excavating in post holes (or similar holes) each n exc 0.5 Cum getting out in hard / dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm watering , and removing surplus soils to a distence nexc 50m and making good surface in hard soils complete all as specified and as directed by Engr-in-Charge
M&L for cement concrete (1:3:6) Type C2 (40 mm garded aggregate) in foundation filling and mass concrete all as specified and as directed by Engr-in-Charge
S&F rolled sections as in main cross beams, hip and jack rafters, purlin where connected to common rafter confirming to Fe-410W (Gde E-250) quality A complete all as specified and as directed by Engr-in-Charge
S & F 0.50mm thick pre painted/coloured galvalum aluminium zinc coating GI based corrugated steel sheet of any colour in roofing covering/cladding to wall fixed with self tapping screws having tensile strength 550 Mpa all as per manufacturers instructions with all fittings and accessories complete all as specified and as directed by Engr-in-Charge
Taking out existing PVC water tanks of capacity 500 litres, setting aside (or lowering if required) for replacement complete all as specified and as directed.
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe spouts for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
Taking up or down steel tubing and connections including cleaning for refixing of 15 mm bore of pipe complete all as specified and as directed.
Taking up or down steel tubing and connections including cleaning for refixing of 20 mm bore of pipe complete all as specified and as directed.
M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
S&F concealed 15 mm bore GI pipe medium grade with all fittings and fixtures and fixed to wall, ceiling, floor complete all as specified and as directed.
M & L for 15 mm bore GI pipe medium grade with all fittings and fixtures and fixed to wall, ceiling, floor complete all as specified and as directed.
M & L for 20 mm bore GI pipe medium grade with all fittings and fixtures and fixed to wall, ceiling, floor complete all as specified and as directed.
S & F in repairs ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore and fixed (minimum weight 210 gms ) complete all as specified and as directed.
S & F in repairs 15 mm dia stop valves cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or union fixed in repair for 15 mm dia GI pipe all as specified and as directed.
S & F 20 mm dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repairs 15 mm dia bib taps fancy type cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass furrule and fixed for 15mm dia pipe complete all as specified and as directed.
S & F in repairs 15 mm dia pillar taps fancy type cromium plated with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed for 15 mm dia pipe complete all as specified and as directed.
S & F in repairs 15 mm dia Brass cromium plated shower rose of 125 mm long leg complete all as specified and as directed.
S&F in repairsGrating round 100 mm size of PTMT (Minimum weight 25gms.) complete all as specified and as directed.
S&F vitreous china wash hand basin, white flat, size 550x400mm incl brackets waste coupling and waste pipe all as specified and directed by Engineer-in-Charge
S/F in repairs Vitreous china wash basin white flat back size 630x450 mm including , waste pipe and plug and porcelain stopper and brackets incl cutting for and pinning in ends of brackets or erecting stand along with 32mm dia CP waste coupling and PVC waste pipe complete all as directed.
S& F in repairs stainless steel Sinks for kitchen or laboratory with plugs, washers and wastes; including beding in cement mortar overall size 495mm x 420 mm bowl size 410 mm x 330 mm x 160 mm complete including fixing cantilever brackets and connecting union to waste pipe and coupling complete all as specified and as directed.
S & F in repairs for PVC connection pipe 15mm dia with PTMT nuts of length 450mm complete all as specified and as directed.
S&F as in repairs PVC low level flushing cristern white 10 litre capacity incl PVC inlet pipe with brass check low level full both sides alongwith PVC flush pipe 32mm dia jointed to WC and handle incl brackets all as directed.
S&F in repair plate rack made of stainless steel 1mm thick kitchen including fixing overall size 915mm x 915mm x 255 mm all as specified and directed.Make Nirali/Silver shine/Jindal
S&F vitreous china squatting pan ORRISA PATTERN size 580x440mm white with integral foot rests excluding flushing cistem & fush pipe fixed in repairs complete all as specified and as directed. .
S&F vitreous china wash down water closet, pan white (pedestal pattern) including plastic water closet black/white closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device excluding fixing bolts flushing cistern and flush pipe complete all as specified.
S&F Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
S&F Soap dish, any type, fixed to plugs with chromium plated brass screw
Dismantling / taking down AC waste/vent pipes fixed to walls with all fittings/ accessories 100 mm dia pipes all as specified and directed by Engineer-in-Charge.
S&F, PVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls, or laid in trenches bore of pipe 110 mm dia complete all as specified and directed by Engineer-in-Charge.
S&F 75mm PVC (SWR) pipe single socketed in any length with rubber ring joints, fixed to walls as directed.
S&F,110 mm dia PVC (SWR) bends, any radius with access door complete all as specified and directed by Engineer-in-Charge.
S&F,75 mm dia PVC (SWR) bends, any radius with access door complete all as specified and directed by Engineer-in-Charge.
S&F, 110 mm dia PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge.
S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement
M&L for concrete bed to drain pipe 150 mm dia including packing under and haunching against the side of pipes after they are laid and tested complete all as specified and directed
M&L for reinforced cement concrete pipes class NP-3 , laid in trenches & jointed complete with collars, dia of pipe 150 mm complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), all as speicfied and directed.
M & L non skid coloured ceramic tiles 7 to 8 mm thick area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm , in floors, etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match. Including 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete.
M&L for non-skid coloured tiles 10mm th (square/rectangular) polished area of each tile 0.36 sqm but n exc 0.42 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm th screed bed in CM 1:6 complete all as specified and as directed.
Ditto as per item No 72 above but on skirting over 10 mm th rendering in CM 1:4 complete all as specified and as directed.
M & L Glazed ceramic tiles in vertical surface 450mm x300x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles incl backing coat 10mm thick in CM 1:4 all as direced.
Dismantling of stone slabs and tiles of any description or thickness in floors aprons laid and bedded and jointed in cement mortar complete all as specified and as directed.
M&L for Marble work green marble 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with green marble shade complete all as specified.
M&L machine cut cuddapah stone slab flooring 20-25mm thick over and including cement screed based 15 mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl cutting polishing and rubbing complete all as specified and as directed.
Demolition of cement concrete ( unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L 150 mm thick stone boulder hard core of gauge n exc 63 mm thick including spreading watering and well ramming in layers in exc 15 cm thick
M&L for 75 mm thick PCC (1:4:8) Type D2 (using 40 mm garded aggregate) in sub base of flooring
M & L for precast concrete interlocking paver block rubber moulded any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 Grade with grey cement and pigment over 25 mm thick sand cushion complete all as specified and as directed.
M & L for Chequered cement concrete tiles of 20 cm x 20cm x 25 mm thick with grey cement and pigment,set and jointed in neat cement slurry in floors including 15 mm thick screed bed or bedding layers in cement mortar 1:6 for laying tiles complete all as specified and as directed.
M&L for PCC 1:2:4 Type b1 (using 20 mm garded stone aggregate) providing cement concrete in roof kerbs or mud stops rounded chamfered of edges all as specified and as directed by Engr-in-Charge
Taking down chowkhats or with shutter (without taking off shutter from the frames) & removing from site exc. 1.5 Sqm but n. exc. 4 Sqm each.
–Ditto- as item No 83 above but n.exc. 1.50 sqm each
Taking down shutters of any description exc. 1 sqm and not exc. 2 sqm each
Cutting holes in brick walls exc half brick but n exc one brick, built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting holdfast and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required -depth of embedded portion of holdfast or lugsmeasured from the face of jamb into the wall - exc. halfbrick but n exc. one brick.
S&F for pressed steel door frames with one or more rebates incl necessary fixing lugs, hinges, lock strike plates of size 125 X 60mm
S&F for pressed steel door frames with one or more rebates incl necessary fixing lugs, hinges, lock strike plates of size 105 X 60mm
M/L for PCC 1:2:4 type B1 in door frame filling all as specified and directed.
S&F mild steel ventilator / window with top hung shutter incl MS peg stay complete
S&F sheet glass 3mm thick ordinary quality and glazing with oil putty in square 0.50 sqm in each pane
S&F factory made 35 mm thick plain framed paneled shutter (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with Commercial veneered on both faces the size of rail and style as per IS-1003 ( Pt-I) kiln seasoned and Chemically pressed of 2nd class hard wood.
S & F factory made 35 mm thick glazed & skeleton shutter of 2nd class hard wood open rebated and prepared to receive gauge (divided into squares with sash bars) edges of framing plain chamfered or rounded, fitted without & fitted beads for securing glass etc, sizes of members of shutters as specified in SSR Pt-I Sec-8 clause 8.23 (a) and fitted to chowkhats complete all as specified.
S&F aluminium powder coated window sliding type (3 track) with frame size100x35x1.2mm and shutter 39.40x17.70x1.2mm with two glass shutter & one mesh shutter incl necessary jointing cleats cleats, glazing clips, rubber packing,and locking arrangement powder coated aluminium snap beading screws with 4mm plain float glass & 0.56 mm dia SS wire mesh, fittings etc complete all as specified.
S&F aluminum powder coated ventelator shutter with or without sash bars of aluminum section weighing 0.55 Kg per Sqm including necessary joining clits , glazing clips, rubber packing, alu. Snap beading , screws, aluminum fittings, suitable handles complete .
S&F in repairs curtain rod 25 mm dia powder coated fancy type complete with side knobs all as specified and directed.
S&F in repairs brackets fancy type powder coated for 25 mm dia curtain rod complete all as directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing
S&F factory made PVC solid panel door shutter 30mm thick (style) connecting of frame made out of MS tube for top and bottom rail. MS frame shall be coverd withheat moulded plain coour PVC 'C' channel having a PVC sheet strips of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail of either side and as gap insert for toprail and bottom rail panellinn of plain colour PVC to be fitted in the ms frame welded/ sealed in the stiles and rail with suitable PVC sheet and loading and jointed together with solvent cement, supplying and fixing in the frame at site all as directed by Engineer -in -charge.
S & F in repairs galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.00mm complete all as specified and directed.
S & F 150 mm size extruded aluminium alloy handles,fabricated type anodised.
S & F aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt 150mm
S & F aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt 100mm
S&F 150mm long alumiunium handles cast type anodised.
S& F But hinges, medium cold rolled mild steel 100mm long all as specified and directed
S & F aluminium alloy , anodised , sliding door bolt with hasp , staple ( bolt type ) & fixing clips of sheet, cast or extruded section & fixing bolts & sliding bolts of extruded section or cast aluminium alloy & fixed - length of bolt 250 mm
S&F in repairs floor door stopper with overall length of cover plate is 150 mm, of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor.
Dismantling of boarding, any description and fixed in any position with nails complete all as specified and directed.
Dismantling timber fillets under 40 Sq.cm in section unframed work , in any position complete all as specified and directed.
S & F in repairs pre-laminated particle board 25mm thick exterior grade prelaminated one side with deocrative choice lamination & other side balancing white lamination, fixed with screws to timber frame work incl 6mm thick teak wood lipping patti complete.
S & F 30 mm thick Second class hard-wood Boarding fixed with nails in any situation complete all as specified and directed.
S & F of 2nd class hard wood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails sectional area exc 13 & not exc 25 sqcm complete all as specified and directed.
S&F in repairs continuous Piano type hinges mild steel bright finish or electrogalvanised (width of flap 40 mm when open) complete.
S & F of 100 mm size brass hasp and staple safety type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
M&L for rendering cement plaster 10 mm thick in CM 1:6 on fair faces of brick walls finished even and smooth w/o using extra cement complete all as specified and as directed.
M & L for Rendering 05 mm thick cement plaster on concrete surface of ceiling in cement mortor 1:3 shall be even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering cement plaster 15 mm thick in CM 1:4 on fair faces of brick work or conrete wall surfaces finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
Supply only integral water proofing compound only
M & L for Preparation of newly plastered surfaces of wall and appling two coats of oil bound distemper on walls over a coat of primer on plastered surfaces complete including 3mm thick wall care putty complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coat of white washing complete all as specified and as directed.
M&L for preparation of new plastered surface of wall and applying three coat of white wash complete all as specified and directed
M & L for Preparation of newly plastered surfaces of wall and appling two coats of cement base paint on walls over a coat of primer on plastered surfaces complete all as specified and as directed.
M&L for preparation and applying two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden surfaces n exc 10cm width or girth complete all as specified
M&L for complete removal of existing treatment from old decorated surfaces of wall and applying two coats of distemper oil emulsion over and including a coat of primer plastered complete all as specified and directed by Engineer - in - Charge.
Complete removal of existing treatment from old decorated surfaces of walls and applying two coats of cement base paint over and including a coat of primer complete all as specified and directed by Engineer - in - Charge.
M&L applying one coat of white wash on old decorated surfaces of ceiling including preparation of surfaces complete all as specified & directed by Engineer-in-Charge.
M&L preparation of old painted wooden surfaces of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified & directed by Engineer-in-Charge.
M&L two coats of synthetic enamel paint to new steel surfaces over a coat of red oxide primer surfaces of any description exc 10 cm in width or girth complete all as specified and as directed by Engr-in-Charge
Demolition of cement concrete (unreinforced) in Suken portion exe 15 cm thickness (below or aboveground level) complete all as specified and directed.
M & L cement conrete 1:7:12 type F2 (uisng 40mm graded aggregate) as in sunkun filling complete all as specified and directed.
Providing and carrying out water proofing treatment to toilet ,sunken slabs ,wet areas etc,after proper surface prepration ,carry out cementitious ingection grouting at leakage point using Cebex 100 plasticised expanding grouting admixture ,application of polymer modified at slab wall junction using Nitoband SBR latex screed modifier cum bonding agent and application ot two coats of brushbond RFX two part acrylic polymer modified cementitious elastomeric waterproof and protective coating etc,complete including 15 mm thick cement plaster in CM 1:4 all tools and plants as per manufacturer's specification paint complete all as specified and directed.
M&L for soakage wells including excavation and earth work in any type of soil, PCC (1:3:6) type C-2 (using 40mm graded stone aggregate), brick wall with honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonary in CM (1:4), RCC cover slab in M-25/SFRC cover interconnecting pipe of RCC/DWC complete filled with brick bats of size 1.2 m dia x 1.5m effective depth for 10 user
M&L for RCC hume pipe septic tank for 10 user's designed to carry sewage and sludge water , including excavation and earth work in any type of soil, PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation, vent shaft connection etc all as specified and directed by Engr-in-Charge
E/M Part
Taking down carefully copper/aluminium point wiring (light, fan, socket or ower) complete,(fittings such as switches, ceiling roses,pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc.
Taking down unserviceable submain wiring alongwith batten/PVC/steel conduits etc and making good disturbed surfaces of walls/ floors to match the existing surfaces all as specified
Taking down unserviceable main switches ,DBs alongwith teak wood boards etc and making good disturbed surfaces of walls/ floors to match the existing surfaces all as specified
M&L for point wiring complete including single core PVC insulated and unsheathed type flexible bright unsheathed multi stranded 1.5sqmm copper conductor FRLS PVC casing caping and surface/concealed PVC Conduit & accessories having ISI mark to be fixed with proper screws/ (MS steel strips if required ) including all accessories/ fittings/ junction boxes /inspection covers etc including hard PVC board of required size fixed with wall surface by means of brass screws and sunk/cupwashers, for mounting of switches fan regulators etc including 1.5 sqmm (22/0.30mm) 1100 V grade PVC insulated, unsheathed flexible muliti stranded copper conductor FRLS cable as continuous earthwire connected to metallic bodies of luminaries/fans etc. at one end and to common earth duly at other end for.
a) One light point controlled by one one way switch
b) One light point controlled by one two way switch
c) One Fan/Exhaust fan point controlled by one switch
d) One switch socket 5 pin 5 Amps flush type on same board.
e) One switch socket 5 pin 5 Amps flush type on Independent board.
f) One bell/ buzzer point controlled by one push button on the same board with other switches or independent
- do - all as per item No 141 above but with 2.5 sqmm (36/0.3mm) FR cable for one socket 5 pin 15Amps flush type on independent board with including earthwire complete.
S & F Switch piano flush type single pole one way 230V 6Amps
S & F Switch piano flush type single pole two way 230V 6Amps
S & F Socket outlet 2 in 1 , 3 pin 5 Amps flush type 230V S.P. multipurpose type
S & F Switch socket combination flush type multi purpose 5A/16A, 5 in 1controlled by one switch 230V.
S & F ceiling rose surface PVC 50 mm dia three terminals including PVC mounting block, white/lvoury /Urea finish.
M&L in repair for stepped type electronic fan regulator flush type on the existin phenolic laminated sheet etc as required for ceiling fan 230 volt AC supply, 50HZ 1200/1400 mm sweep
S & F Bell push, flush type, 5 amp, 230V
S & F Bell ding dong type 230V
M&L submain wiring with 2 single core PVC insulated multistranded flexible copper conductor 1100Volts grade (FRLS) cables 4.sqmm and 1 run 2.5 Sq mm PVC insulated multistrand cu conductor cable (FRLS) of green colour for continious earthing drawn through PVC surface/concealed PVC conduit of suitable size and with all accessories all as directed and specified by Engr-In-charge.( Note: Two runs of 4 sqmm, one run of 2.5 sqmm copper conductor and one run of surface/concealed PVC conduit of suitable size and with all necessary fixing accessories and making good disturbed surface area shall be measured as one length.)
S&F submain wiring with 2 single core PVC insulated multistranded flexible copper conductor 1100 Volts grade cables 4 Sqmm and 1 run 1.5 Sq mm Earth Wire PVC insulated multistrand cupper conductor cable (FR) drawn through PVC casing caping of suitable size and with all accessories all as directed and specified by Engr-In-charge.
M & L for earthing complete with galvanised steel earth plate electrode 60cm ×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel,earth wire protected by GI pipe 15 mm dia 'light grade' including charcoal dust, common salt, excavation & earth work, PCC Pit with 1:3:6 type C-1, 40 mm thick RCC cover in 1:2:4 type B-1 reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handles 12 mm dia, PGI funnel & GI watering pipe 'light grade' 20 mm bore all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
M & L in repair MCB DB SPN sheet metal double door enclosure mounted on teak wood board of suitable size for mounting MCB 230 Volts , 4 way
M & L MCB DB SPN sheet metal double door enclosure mounted on teak wood board of suitable size for mounting MCB 230 Volts with 200 Amps rated bus bar 8 way
S & F MCB SPN 10-40 amps, 240Volts 10KA
S & F MCB SPN 5-32 amps, 240Volts 10KA
S & F MCB SP 5-40 amps, 240Volts 10KA
S&F LED lights fitting 1x20 Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
S&F in replacement of 2 feet 10 W linear aluminium LED Batten with white acrylic cover complete with all accessories prewired and connecting up twin core twisted flexible copper conductor cable with suitable size.
Taking down ceiling fan 1200/1400 mm sweep / exhaust fans including disconnection of electric connection and removing the blades in safe for reinstalling
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Supply and fix in repair LT indoor panel board made up of 2 mm thick MS Sheet duly powder coated with closing and locking arrangement as per suitable size fixing on wall with wooden plank of 18 mm thick inside panel including taking down and refixing existing electronic energy meter with replacemnt of following new items :- a) MCB DB TPN 4 way double door -01 No b) Isolator 4 pole 100A -01 No (Incoming) c) Isolator DP 40A - 05 No ( Out going)
S & F LED light fitting for building security/street light fitting 1x 20 w, 230 V,complete with all accessories internally pre-wired and including connecting up with 2.5 sqmm twin core flexible copper cable for connection from ceiling rose to fitting including LED light and GI bracket medium grade of 1.2 meter shaped to 120 degree for fixing of fitting on wall with clamps and Make : Bajaj / philips / Crompton
S & F exhaust fan AC single phase 230 V,300 mm sweep, heavy duty with louvers, metal body, blades, Insulation Class A including capacitor complete all as specified and directed by Engineer-in-charge( including making hole on exixting wall and making good surface of wall with necessary PCC Work and plaster etc.) . Make :-Model : Ventil Air-DB 300 mm of Havells and equavalant of GEC/Bajaj/ CG/ Khaitan/ Usha
Dismantling /disconnecting LT cables of any size with accessories. Old unserviceable of any type broken or damaged cables fitting on poles / laid in trenches and keeping aside for further disposal.
Supply & Laying cable XLPE insulated screened PVC bedded ,galvanized steel strip or wire armoured ,electric power cable heavy duty 1100 volts grade with strandad aluminum conducter of 25 sq. mm X 4 core :- Make :- Havells/ Polycab/ Gloster
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core
Supply and lay GI galvanized, “Medium class” Pipe including fittings of following size.
a) 20 mm dia.
b) 25 mm dia
b) 40 mm dia
S&F Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe of 20 mm dia.
S&F stop Valve, screwed both end for iron pipe or for unions and fixed, 25 mm fancy type.
RAMESH PATIL
Santhi Enterprises
KARPE AND SONS CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .