Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC | ₹33.3 L | L1 | Accepted-AOC AOC |
| 2 | L2₹33.4 LRejected-Finance | ₹33.4 L | L2 | Rejected-Finance H |
Tender Value
Refer Docs
EMD Value
₹3.4 L
Closing Date
26 Mar 2026, 12:00 pmClosed
Executive Engineer P.D. P.W.D. Ballia
Executive Engineer P.D. P.W.D. Ballia
Repair work of the damaged culvert located on Sikandarpur road
2026_CEUAZ_1128513_1
1238/4A Date 13.03.2026
Open Tender
Civil Works
30 days
Ballia
Please refer Tender documents.
2 documents required · 2 mandatory
₹945
₹3.4 L
30 Apr 2026
21 Mar 2026
26 Mar 2026
21 Mar 2026
26 Mar 2026
21 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Constn. Of embankment with approved materials obtained from borrow pits with all lifts and leas, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.1 & 300.2As per Technical specification clause 301.5 | |||||
| 2Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and Technical Specifications. | |||||
| 3Demolising RCC work by Mechnical means and stackpilling at designated location and disposal of dismentalled matgerials upto a lead of 1 Km. Stacking serviceable and unserviceable matgerials seperately and including cutting rainforcement bar complete in all respect. S.I. No. 694 | |||||
| 4RCC grade M30 using batching plant transit mixer & concrete pump. | |||||
| 5Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications. | |||||
| 6Plain cement concrete M25 nominal mix with crushed stone aggregate 40 mm nominal size mechanically mixed | |||||
| 7Struck cement pointing in 1:2 cement and fine sand mortar complete in all respect. As per MORT&H 13.2-1300 &2200 | |||||
| 8Finishing walls with water proof cement paint. New work two or more coat applied S.I. No. 660+661 | |||||
| 9Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811 | |||||
| 10Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger si | |||||
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.43 MB
BOQ_2104829.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid