| Sl No | Description | Qty | Unit | Shiv Jyoti Enterprises L2 | SANJAY KUMAR SHARMA ENGICON PRIVATE LIMITED L1 |
|---|---|---|---|---|---|
| 1.00Construction of 2.3 MLD UnCoventional WTP | |||||
| 2.00Doing Geotechnical survey, Collecting field data, designing aesthetically, getting it approved by competent authority and Providing all labours and necessary equipment for designing & construction of Unconventional WTP . With all complete job. | |||||
| 3.00Designing (aesthetically), providing and constructing and comissioning Unconventional Water Treatment Plant consisting of Civil works, mechanical, electrical works including cost of providing and applying epoxy paint to inside surface of water retaining structures in contact with chlorine and providing anti termite treatment to entire structure below ground level, mechanical and electrical components of various sub works as given below, including necessary hydraulic testing, structural testing equipment testing, trial run for a period of 3 months etc. complete as directed by Engineer-in-charge (turn-key job) works. | |||||
| 4.00Aeration fountain | |||||
| 5.00Inlet arrangements | |||||
| 6.00Mixing channel with ventury flume and flow measuring arrangement | |||||
| 7.00Inlet chamber | |||||
| 8.00Flocculator- Conforming to I.S. 7208-1974 (Type-C) with detention period of 30 minutes | |||||
| 9.00Tube settlers-Designing, fabricating and constructing Tube Settlers with square or any other shaped tube like Circular, Cheveron, Hexagonal etc .having proven performance | |||||
| 10.00Rapid sand gravity filters-All valve shall be glandless. | |||||
Tender Value
₹27.9 Cr
EMD Value
₹27.9 L
Closing Date
25 Nov 2022, 4:00 pmClosed
Executive Engineer,
Executive Engineer,D.W.and S.Division Jamtara
Tesjoiriya Panchayat Rural Water Supply Scheme under D.W. and S. Division Jamtara on turnkey basis
2022_DWSD_63004_1
08/DWSD/JMT/202222-23
Open Tender
Civil Works
640 days
Jamtara
Please refer Tender documents.
7 documents required · 7 mandatory
₹10,000
Yes
Executive Engineer,D.W.and S.Division Jamtara
₹27.9 L
Yes
O/o Engineer in Chief, D.W. and S. D., Nepal House
16 Jan 2023
14 Nov 2022
26 Nov 2022
14 Nov 2022
25 Nov 2022
16 Nov 2022
16 Nov 2022
Amount
Construction of 2.3 MLD UnCoventional WTP
Doing Geotechnical survey, Collecting field data, designing aesthetically, getting it approved by competent authority and Providing all labours and necessary equipment for designing & construction of Unconventional WTP . With all complete job.
Designing (aesthetically), providing and constructing and comissioning Unconventional Water Treatment Plant consisting of Civil works, mechanical, electrical works including cost of providing and applying epoxy paint to inside surface of water retaining structures in contact with chlorine and providing anti termite treatment to entire structure below ground level, mechanical and electrical components of various sub works as given below, including necessary hydraulic testing, structural testing equipment testing, trial run for a period of 3 months etc. complete as directed by Engineer-in-charge (turn-key job) works.
Aeration fountain
Inlet arrangements
Mixing channel with ventury flume and flow measuring arrangement
Inlet chamber
Flocculator- Conforming to I.S. 7208-1974 (Type-C) with detention period of 30 minutes
Tube settlers-Designing, fabricating and constructing Tube Settlers with square or any other shaped tube like Circular, Cheveron, Hexagonal etc .having proven performance
Rapid sand gravity filters-All valve shall be glandless.
Filter house
Chemical house
Alum tanks- 2Nos. with mixing, carrying and dosing arrangements with piping.
100 Kg. chlorine cylinder for capacity upto 5 MLD and chlorine tonner for capacity above 5 MLD
TCL solution tank with mixing, carrying and dosing arrangement with piping.
Bypass arrangement
External and internal electrification
Laboratory equipments
Wash water tanks of capacity equal to 12 minutes to wash specified numbers of filter beds at time at 600 liters/ m2 / m under head of 12 m at under drain.
Wash water pumps with 100% standby
Air blowers capable of delivering 600 LMP per square metre of free air of filter area at 0.4 Kg / sqcm at the under drains (100 % standby). Air Blowers Shall be adopted for WTP having capacity more than 3 MLD only . Below 3 MLD Capacity, Air blowers shall not be adopted.
Pure water sump of capacity equal to 1 hour pumping capacity.
Pure water pump house over the sump / by the side of sump.
Drainage arrangements
Alum store
Sanitary block with necessary water supply and drainage arrangements and internal WBM roads.
These rates are applicable for seismic zones 2, 3 and 4.
Rates given below are inclusive of uplift pressure if any and dewatering during the entire work.
All RCC structures shall be constructed in M-250. Structures in contact with water shall be in M-300.
Unconventional Treatment Plants less than 1 MLD capacity shall not be constructed.
All the Structural Steel works/ Fabrications are to be provided with application of Hot Dip Zinc coating according to specification as per IS 4759:1996 (Reafirmed 2006)
Note: Conditions from Sr. No. 1 to 28 shall form a part and parcel of the tender and must be incorporated in draft tender papers of Unconventional treatment plants.
Capacity of Unconventional WTP – 2.30 MLD
Elevated Service Reservoir (ESR)
Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authorityand Providing all labours and equipment for designing & construction of ESR all complete job. (Please refer to Section 5,Sl. 2.8 of SBD)
RCC ESR at Zone - 1 Capacity 2.90 Lakh Litre Stagging Height - 24.00 m
RCC ESR at Zone -2 Capacity 3.30 Lakh Litre Stagging Height - 24.00 m
Construction of Intake Well with Pump House.
Doing Geotechnical survey, Collecting field data, designing aesthetically, getting it approved by competent authority and construction of R.C.C Intake well with Pump house all complete job.
Earthwork in excavation of foundation trenches of toe wall Spillway head regulator , outlet ,intake well etc. as per a designed section in all kinds of soil, including moorum soil, soil mixed with kankar, pebbles and boulders up to 300 mm size and disposal of the same (beyond 50 M away from the edge of the trenches) with in initial lead of 150 M all lifts of 1.5 M as per specification and direction of E/I.
Initial lift
1st lift
2nd lift
Earthwork in excavation of foundation trenches of toe wall spilllway, head regulator intake well, outlet etc. as per designed section in ordinary or soft rock where (blasting is not needed) beyond 50m from the edge of the trenches in the country side with initial lead of 150m. and initial lift of 1.5m. as per specification and direction of E/I (Excavated hard rock size should not be more than 150 lb.).
3rd lift
Earthwork in excavation of foundation trenches of toe wall spilllway ,head regulator intake well , outlet etc. as per designed section in hard rock where blasting is needed and stacking properly in approved stack size in approved stack yard beyond 50m from the edge of the trenches in the country side) with initial lead of 150m. and initial lift of 1.5m. as per specification and direction of E/I (Excavated hard rock size should not be more than 150 lb.).
4th lift
5th lift
6th lift
Plain cement concrete in well foundation complete as per drawing & technical specification. Well staining PCC M-15 Grade. Foundation
Plain cement concrete in well foundation complete as per drawing & technical specification. Well staining PCC M-15 Grade. Foundation
Plain/ Reinforced cement concrete work in well foundation complete as per drawing & technical specification . Well staining RCC M-30 grade.
Vertical wall of Intake well
Furnishing and placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification. RCC Grade M25.
floor slab Beam
Furnishing and placing Reinforced/ Prestessed cement concrete in super-structure as per drawing and Technical specification. RCC Grade M25.
Floor slab
Furnishing and placing Reinforced/ Prestressed cement concrete in super- structure as per drawing and Technical specification. RCC Grade M25.
Column up to roof
Furnishing and placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification. RCC Grade M25.
Corbel, Beam at lintel level + Roof level
Furnishing and placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification. RCC Grade M25.
Pump House Roof
Providing average 63mm thick RCC M-200 with nominal mix of (1:1.5:3) in chajja with approved quality of stone chips 20mm to 6mm. Size graded and clean coarse sand of F.M.2.5 to 3 including making drip course in concrete, screening, centering, shuttring and mixing cement concrete in mixer and placing in position vibrating, striking, 6mm. Cement plaster (1:4) in ceiling and sides of chajja with sand of F.M. 1.5, curing (but excluding the cost of reinforcement), taxes, and rotality all complete as per building and direction of E/I. Specification.
Centering and Shuttering including shuttring, proping etc. and removal of form of chajja.
Providing TMT reinforcement (TOR steel) 12 mm as per approved design drawing , removal o f rust cutting , bending, binding including supplying annealed wire placing MS rods in position all complete job as per specification and direction of E/I.
Providing designation 75 A brick work in CM 1:6 in superstructure with approved quality of clean coarse sand of FM 2 to 2.5 including providing 10 mm thick mortar joints,cost of screening of materials, scaffolding, racking out joints to 15 mm depth curing, taxes and royalty all complete as per building specification and direction of E/I
Supplying fitting and fixing full glazed steel Supplying fitting and fixing fully glazed steel door window or ventilators standard rolled Z and mullion section and sizes as per I.S.-1038 joints met and welded with 100 x 16 x 3 mm MS lugs fixed in cement concrete (1:2:4) blocks 15 x 10 x 10 cm size including cost of oxidized iron fitting with hinges, handle per steps, catch springs 3mmv thick plain glass panes with Aluminium beads and inner frame fixed with lugs of 20 mm long 6.3mm G.I. counter sunk machine screw and nuts and applying a coat of red lead paint, carriage to work site hoisting and placing in position in all storey and taxes all complete as per building specification and direction of E/I.
Supplying fitting & fixing collapsible gate of approved size and make properly fabricated with vertical double channel 20x10x2mm, at 100mm centres and braced with MS flat diagonals 20x3mm with top and bottom rails of T irons 40x40x6mm with 38mm dia steel pulleys complete with bolts nuts locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, carriage, hoisting and taxes all complete as per building specification & direction of E/I .
Providing 12 mm thick cement plaster (1:6) for inside &cut safe surface of p/H with clean coarse sand of P M 15 including screening, curing with all leads and lifts of water scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 6 mm thick cement plaster (1:4) in ceiling of P/H & jack well with clean coarse sand of FM 1.5 including screening, curing with all leads and lift of water , scaffolding taxes and royalty all complete as per building specification and direction of E/I
Providing 12 mm thick water proof cement plaster (1:3) with clean coarse sand of FM 1.5 with 5 % cicoor or any other approved water proofing compound including screening curing with all leads and lifts of water scaffolding taxes and royalty all tex etc. complete job as per building specification and direction of E/I
Providing two coat of snowcem of approved shade and make over a coat of cement of primer on new surface including preparing the plasterded surface smooth with sand paper,scaffolding, curing and taxes all complete as per building specification and direction of E/I
Providing two coat of painting with ready mixed paint of approved shade and make over steel surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I
Providing & fixing R.S joist ISMB 300 x 140 mm (Gr. A) size fitting and fixing in possion including cutting to required in shape and size, its carrage applying a priner coat of red lead paint etc. all complete job and direction of E/I.
Providing an fixing G.I pipe railling having 1.0 m height consisting 50 x 50x 6 mm thick M.S angles as vertical at 1.5 m c/c and additional post at every corner with 3 rows of 25mm dia G.I pipe of medium class variety as horizontal and painting 3 coat of oil paint over one coat of anticorrsive paint of approved colour and shade including cost of all labour transporting bents to curved shape etc. complete
Providing and fixing MS sluice gates in position as per dtailed drawing and specification including cost of all materials, labour, operating pedestal, connecting rod, painting with three coats of anti-corrosive paint, etc. complete as directed by Engineer-in-charge.
Providing and fixing MS rose pieces in position as per detailed drawing and specification including cost of all materials, labour, operating pedestal, connecting rod, painting with three coats of anti- corrosive paint, etc. complete as directed by Engineer-in-charge.
Providing and Fixing in Position of 20 mm dia M.S. bar Step with proper anchorage, etc. and providing and applying 3coats of ant- corrosive paint , etc. complete as directed by Engineer in charge.
Earthwark in back filling foundation trenches or back filling of masonary structures with suitable earth in layers not exceding 150 mm thick well watered rammed and fully compacted and finaly dressed with earth obtained from excavtion of foundation and kept at a lead of 30 m and initial lead of 1.5 m complete as per specification and direction of E/I .
Carriage of construction materials to work site including loading, unloading & stacking etc. all complete.
Cement 10 KM lead
Steel 10 KM lead
Sand 36 KM lead
Bricks 6 KM lead
Stone/Stone Chips 11 KM lead
Construction of RCC Gang Way 50 M long
Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authority Construction of Gang Way 50 M long and 3.0 M wide etc. all complete job.
Earthwork in excavation of foundation trenches of toe wall Spillway head regulator , outlet ,intake well etc. as per a designed section in all kinds of soil, including moorum soil, soil mixed with kankar, pebbles and boulders up to 300 mm size and disposal of the same (beyond 50 M away from the edge of the trenches) with in initial lead of 150 M all lifts of 1.5 M as per specification and direction of E/I.
Initial lift
1st lift
2nd lift
Plain/ Reinforced cement concrete, in well foundataion complete as per drawing and technical specification. RCC Grade M15
Plain/Reinforced cement concrete, in well foundation complete as per drwaing and technical specification. Well steining RCC M30 Grade.
In Raft Foundataion
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification. RCC Grade M30
For Columns
Furnishing and placing Reinforced/ Prestressed cement concrete in superstructure as per drawing and technical specification RCC Grade M25
In Gangway Floor Beam
Furnishing and Placing Reinforced/ Prestressed cement concrete in superstructure as per drawing and technical specification. RCC Grade M25 For Solid slab super-structure
Providing TOR steel reinforcement of 10mm, 12mm and 16mm dia. bar as per approved design and drawing excluding carraige of MS bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete job as per specification and direction of E/I
Providing 12 mm thick cement plaster (1:4) with approved quality of sand of requisite F.M.1.5 w a s h e d a n d screened including curi n g , scaffolding wherever required and its removal royalty and all taxes etc. complete job as per specification & direction Of E/I.
Providing 6 mm.Thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification & direction of E/I.
Providing &Fixing G.I Pipe Railling having 1.0 m height consisting 50 x 50 x 6 mm thick M.S Angles as verticals at 1.5M c/c , and additional posts at every corner with 3 rows of 25 mm dia G.I. pipes of medium class variety as horizontal & painting 3 coats of oil paint over 1 coat of anticorrosive paint of approved colour & shade including cost of all labour, transporting bends to curved shape, etc. complete.
Providing two coat of snowcem of approved shade and make over a coat of cement primer on new surface including preparing plastered surface the smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/I.
Carriage of construction materials to work site including loading, unloading & stacking etc. all complete.
Cement 10 KM lead
Steel 10 KM lead
Sand 36 KM lead
Stone/Stone Chips 11 KM lead
Infiltration Gallery
Earthwork in excavation of foundation trenches of toe wall,spillway,head regulator,outlet,intake wall etc.as per designed section in all kind of soil including moorum soil,soil mixed with kankar,pebbles and boulders upto 300mm size and disposal of the same (beyond 50m away from the edge of the trenches ) with initial lead of 150m and initial lift of 1.5m as per specification and direction of E/I.
Initial Lift
1st Lift
2nd lift
Providing and Supplying ISI standard welded D.I. double flanged pipe as directed by Engineer- In-Charge
For Header D.I pipe K-7 300 mm Dia.
Perforeted/Slotted pipe 250 mm Dia.
Providing lowering,laying and placing in position,shrouding material for porous pipe gallery/slotted pipe gallery/trench gellary with all leads and lifts involved including transportation of materials and placing in position with given section etc.completed as per direction by E/I.
40 mm pabbles
Filling in foundation trenches and plinth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 m all complete as per building specification and direction of E/I (made of measurement compacted volume).
Dewatering the excavated trenches & pools of water in the building trenches/pipeline trenches,well works by using pumps & other devices including disposing off water to safe distance as directed by the engineer-in-charge.including cost of machinary,labour,fuel),etc.
Providing, constructing coffer dam in river basin / dam storages as per type design including excavation, filling the middle portion with B.C. soil (in gunny bags if required). Providing impervious / semimpervious materials on both side of B.C. soil (in gunny bags if required) including ramming , compacting to satifaction of Engineer-in- charge, till the completion of work including dismantling coffer dam after completion of works and disposing off material as directed by the Engineer-in-charge.
Carriage of construction materials to work site including loading, unloading & stacking etc. all complete.
Stone/Stone Chips 11 KM lead
COFFER DAM
Providing, constructing coffer dam in river basin/dam storages as per type design including excavation,filling the middle portion with B.C.soil (in gunny bags if required).Providing impervious / semimpervious materials on both side of B.C.soil(in gunny bags if required) including ramming, compacting to satisfaction of Engineer-in-charge,till the completion of work including dismantling coffer dam after completion of works and disposing off material as directed by the Engineer-in-charge.
For Gangway
For Intake Well
Dewatering the excavated trenches and pools of water in the building trinches/pipe line trenches , well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer- in -charge (including cost of machinery , labour fuel, etc. complete)
For Gangway
For Intake Well
Mechanical & Electrical Work at Intake well
Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authority and Raw water pumping Machinery with all complete job.
Supply, installation, testing and commisssioning of vertical turbine pumpsets with allied equipment as under-
Vertical Turbine Pump [make: Kirloskar / Worthington / Mather & Platt] as per IS: 1710/1972, SIC of VT pumpset, capable of discharging 1595 LPm against the total head of 146 M coupled with squirrel cage induction motor , (IE3) rating having 20% more BHP than that of pump, operating on 1500 rpm,415V, 50Hz [make: Kirloskar/ Marathon/ BHEL/ABB/ Crompton Greaves] all complete alongwith suitable discharge head, base plate & accessories such as sutable MS Column pipe flanged type 60 ft spited bearing, line shaft rubber cut less-bush foot value with strainer, sluice valve ratio PN-1.6, NR valve, pressure gauge including cost of construction PCC foundation with cement sand, stone chips (1:2:4), foundation bolt nut, spring washer, plasting punning of foundation and making delivery pipe with piping works common header, required for the job and etc., all complete job, testing of pump set on full load at site. (cost of Pump ,Motor etc)(Contractor will again have to check the design of pump & motor and get it approved rate by the Dept.)
Discharge- 1595 LPM; Head-146 m (1W+1S)
Cable: Power wiring with required 240 Sq mm, 3.5 core, 1.1KV grade, armoured cable, Standard Aluminium conductor, XLPE/PVC insulated cable from Transformer to Stablizer & Panel (MCP) including laying on wall or on floor as where required, jointing and making proper terminations,etc. all complete. (240mm²)
Cable: Power wiring with 70 Sq mm, 3 core, 1.1KV grade, Unarmoured cable, Standard Copper conductor, XLPE/PVC insulated cable from Panel (MCP) to Motors & Staters including laying on wall or on floor as where required, jointing and making proper terminations,etc. all complete. (70 mm²)
Earthing: Earthing with copper earth plate including accessories and providing masanory enclosure with cover plate having locking arrangement and watering pipe of 2.7 m long etc. with charcoal / coke and salt as required conforming IS:3043.
Starter: Supplying, installation, testing & commissioning of assembled Fully Automatic Star Delta starter, in a provided cubical panel to operate induction motor with no volt coil, over load relay and ON/OFF push buttons, with necessary material and connected to supply, etc. all complete.
Crane: Providing, erecting triple spur gear type Chain Pulley Block suitable for 3 Tonne capacity as below with 6 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per IS 3832 carrying ISI mark, with travelling trolley etc.
Lighting: Providing internal and external lighting by doing wiring and installing lumenaries e.g. suitable Wattage of LED light fittings in pump house, gangway, etc. all complete as per requirement at Pump house area.
Safety Items: Supplying, Installation and erecting of Fire extinguisher, Lightening Arrestor, emergency light, First aid box, insulation gloves & shoes, tools & tackles, rubber matting, instruction manual, etc. as per requirement and Indian standards at Pump house.
(Mechanical & Electrical Part at WTP)
Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authority and Clear Water C.F. Pump with all complete job
Suply, installation, testing and commisssioning of horizontal casing centrifugal pumpsets with alied equipment as (Please refer to Section 5,Sl. 2.5 of SBD)
Horizontal Split Casing Multistage Centrifugal Pump as per IS 5120 [make: Kirloskar/ Worthington/ Mather & Platt], capable of discharging suitable flow & head. mounted on common base plate and coupled with TEEC & IE 3, squirrel cage induction motor, rating of motor 20% more BHP than that of pump, operating on 1500 rpm, 415V, 50Hz [make:Kirloskar/ABB/ Crompton Greaves/BHEL/Marathon] pressure gauge, required size of sluice valve and non-return valve, standard fittings etc. including construction of MS Suction and delivery header, jointing it with Suction and Delivery line by providing required MS/CI pipes, common header, flanges,reducer and specials, nuts bolts, packings etc. all complete as per the requirement, standards and instruction of E/I.(Contrator will again have to check the design of motor,pump & he will to get it approved by the Deptt.)
Discharge- 752 LPM; Head-36.00 m (1W+1S)
Discharge- 843 LPM; Head-57.00 m (1W+1S)
Cable: Power wiring with required 120 Sq mm, 3.5 core, 1.1KV grade, armoured cable, Standard Aluminium conductor, XLPE/PVC insulated cable from Transformer to Stablizer & Panel (MCP) including laying on wall or on floor as where required, jointing and making proper terminations,etc. all complete. (120 mm²)
Cable: Power wiring with 10 mm², 3 core, 1.1KV grade, Unarmoured cable, Standard Copper conductor, XLPE/PVC insulated cable from Panel (MCP) to Motors & Staters including laying on wall or on floor as where required, jointing and making proper terminations,etc. all complete.
Cable: Power wiring with 16 mm², 3 core, 1.1KV grade, Unarmoured cable, Standard Copper conductor, XLPE/PVC insulated cable from Panel (MCP) to Motors & Staters including laying on wall or on floor as where required, jointing and making proper terminations,etc. all complete.
Earthing: Earthing with copper earth plate including accessories and providing masanory enclosure with cover plate having locking arrangement and watering pipe of 2.7 m long etc. with charcoal / coke and salt as required conforming IS:3043.
Starter: Supplying, installation, testing & commissioning of assembled Fully Automatic Star Delta starter, in a provided cubical panel to operate induction motor with no volt coil, over load relay and ON/OFF push buttons, with necessary material and connected to supply, etc. all complete. (12.50 HP)
Starter: Supplying, installation, testing & commissioning of assembled Fully Automatic Star Delta starter, in a provided cubical panel to operate induction motor with no volt coil, over load relay and ON/OFF push buttons, with necessary material and connected to supply, etc. all complete. (25 HP)
Crane: Providing, erecting triple spur gear type Chain Pulley Block suitable for 3 Tonne capacity as below with 6 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per IS 3832 carrying ISI mark, with travelling trolley, etc
Safety Items: Supplying, Installation and erecting of Fire extinguisher, Lightening Arrestor, emergency light, First aid box, insulation gloves & shoes, tools & tackles, rubber matting, instruction manual, etc. as per requirement and Indian standards at Pump house.
Raw Water Rising main.
Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authority and Laying of Raw water Rising Main.
Providing and Supplying ISI mark centrifugally cast (spun) ductile iron pressure pipe for water works with socket and Spigot ends confirming to IS8329/2000 in standard lengths of class K-9 suitable for push- on - joint (Rubber gasket D jointing) with cement mortar lining inside the pipes with outside zinc and bituminous coating including transportation, taxes & duties contractor profit insurance carriage to work site with loading Unloading etc stacking including inspection charges and all taxes all complete. (including cost of one no. gasket for each pipe)
DI K-9,Dia 200 mm
Providing and supplying lSI standard D.I.specials & fitting with sealing rubber gasket of S.B.R. complete with cast iron follower gland and M.S. nut & bolts coated or otherwise protected from rusting and suitable for 0.1. pipes including cost of all labours and materials and transportation to stores 1 site, loading, unloading including all taxes,etc . complete as per I.S. 9523
Providing and Supplying ISI mark CI D/F reflux valves (non return valves) of following dia inspection charges unloding from railway wagon, loading into truck, transportation upto departmental stores/ site, unloding, stacking etc. complete. Reflux valves as per I.S. 5312 Part l (1984) Without bypass arangement PN-1.6 200 mm Dia
Providing Double Flanged Sluice valve confirming to IS 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps including all taxes transportation etc. complete. (without by pass arrangement PN 1.6)
Sluice Valve-Dia 200 mm
Scour Valve-Dia 100 mm
Providing and supplying air valves as per IS - 14845-2000 and M J P's Standard specifications of approved make and quality of following diameters including all taxes (central and local ) , railway friegth, insurance third party inspection charges loading unloading transportation up to departmental store/site etc.complete .
(Double Ball Flanged Type Air Valve P.N 1.6 Dia- 25 mm )
Earth Work in excavation (As per I.S. 3114/1965) for laying of Different types and size of pipes so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of Engineer in-charge (b) For classification of soil item -B
Earth work in excavation of foundation trenches as per design section in ordinary or soft rock (where blasting is not required and disposal of excavated materials so obtained (50 m away from the edge of the trenches ) with initial lead of 10 m and initial lift of 1.5 m as per specification amnd direction of E/I.
Supplying labours, tools , tackles, lubricant etc for laying and jointing C.I.S/S Tyton pipes (class L A/DI) trenches supplying rubber gasket (Rubber gaskets confirming to I.S.S.-5382-1969) and making gasket joints including providing night guard ,barrier and red light to safe guard against accident ,all complete ( Pipe to be supplied departmentally free of cost and laying of pipes is to be done as per (I.S.S.3114-1985) as per design, specification and direction of E/I.
200 mm dia K-9
Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer –in–charge including cost of conveyance from store to site of work, cost of all material and giving satisfactory hydraulic testing etc. complete.(for all class of valves).
25 mm Dia (Double Ball air valves)
Supplyng labour and tools for fixing CI sluice valve in trenches with a pair of C.I Tail pieces incluidng making lead caulked joints and flenged joints as per I.S specification, including supplying all jointing materials (Pig lead confirming to I.S.S 782-1978, yarn confirming to I.S.S 6587-1972 and nuts and volts confirming to I.S.S 1364-1983) including drillig holes in flanges if required as per specification and direction of E/I.
Sluice Valve PN 1.6 200 mm dia
Sluice Valve PN 1.6 100 mm dia
Earth work in backfilling the trenches after lying of different types and sizes of pipes with earth removed during excavated within initial lead and lifts as per specification and direction of Engineer in charge.
Supplying labour tools and tackles for testing of laid CI or UPVC or HDPE or AC or DI pressure pipe up to 60 m meter head of water all complete as per specification and direction of engeneer- in- charge. Water to supplied free of cost departmentally.
Labour charge for one cutting of cast iron pipe and specials including necessary tools and plants , chipping of filling surface finish as per specification and direction of E/I
200 mm dia pipe
Construction of B.W. masonary valve chamber of size (1.20X0.90X1.50) m size
Supply of all materials & Construction of thrust block wherever required.
200 mm dia pipe
Clear Water Rising main.
Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authority and Laying of Clear water Rising Main.
Providing and Supplying ISI mark centrifugally cast (spun) ductile iron pressure pipe for water works with socket and spigot ends confirming to IS 8329/2000 in standard lengths of class K-9 suitable for push-on-joint (Rubber gasket D jointing) with cement mortar lining inside the pipes with outside zinc and bituminous coating including transportation, taxes & duties contractor profit insurance carriage to work site with loading unloading etc. stacking including inspection charges and all taxes all complete. (including cost of one no. gasket for each pipe)
DI K-9,Dia 150 mm
Providing and supplying lSI standard D.I.specials & fitting with sealing rubber gasket of S.B.R. complete with cast iron follower gland and M.S. nut & bolts coated or otherwise protected from rusting and suitable for 0.1. pipes including cost of all labours and materials and transportation to stores 1 site, loading, unloading including all taxes,etc . complete as per I.S. 9523
Providing and Supplying ISI mark CI D/F reflux valves (non return valves) of following dia inspection charges unloding from railway wagon, loading into truck, transportation upto departmental stores/ site, unloding, stacking etc. complete. Reflux valves as per I.S. 5312 Part l (1984) Without bypass arangement PN-1.6
150 mm Dia
Providing Double Flanged Sluice valve confirming to IS 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps including all taxes transportation etc. complete. (without by pass arrangement PN 1.6)
Sluice Valve-Dia 150 mm
Scour Valve-Dia100 mm
Providing and fixing removable mechnism type bulk water meter as per ISO-4064 150mm
Providing and supplying air valves as per IS - 14845-2000 and M J P's Standard specifications of approved make and quality of following diameters including all taxes (central and local ) , railway friegth, insurance third party inspection charges loading unloading transportation up to departmental store/site etc.complete .
(Single Ball Flanged Type Air Valve P.N 1.6 Dia-25 mm)
Earth work in excavation (As per IS. 3114/1965) for laying of different types and sizes of pipes so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of Engineer in charge
Earth work in excavation of foundation trenches as per design section in ordinary or soft rock (where blasting is not required and disposal of excavated materials so obtained (50 m away from the edge of the trenches ) with initial lead of 10 m and initial lift of 1.5 m as per specification amnd direction of E/I.
Supplying labours, tools , tackles, lubricant etc for laying and jointing C.I.S/S Tyton pipes (class L A/DI) trenches supplying rubber gasket (Rubber gaskets confirming to I.S.S.-5382-1969) and making gasket joints including providing night guard ,barrier and red light to safe guard against accident ,all complete as per (I.S.S.3114-1985) as per design, specification and direction of E/I.
DI K-9,Dia 150mm
Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer –in–charge including cost of conveyance from store to site of work, cost of all material and giving satisfactory hydraulic testing etc. complete.(for all class of valves).
25 mm Dia (Double Ball air valves)
Supplyng labour and tools for fixing sluice valve in trenches with a pair of C.I Tail pieces incluidng making lead caulked joints and flenged joints as per I.S specification, including supplying all jointing materials (Pig lead confirming to I.S.S 782-1978, yarn confirming to I.S.S 6587-1972 and nuts and volts confirming to I.S.S 1364-1983) including drillig holes in flanges if required as per specification and direction of E/I.
Sluice Valve PN 1.6-150 mm Dia
Scour Valve PN 1.6-100 mm Dia
Earth work in backfilling the trenches after lying of different types and sizes of pipes with earth removed during excavated within initial lead and lifts as per specification and direction of Engineer in charge.
Supplying labour tools and tackles for testing of Laid CI or UPVC or HDPE or AC or DI pressure pipe up to 60 mm meter head of water all complete as per specification and direction of engeneer- in- charge.
DI K-9,Dia 150mm
Labour charge for one cutting of cast iron pipe and specials including necessary tools and plants , chipping of filling surface finish as per specification and direction of E/I
DI K-9,Dia 150mm
Construction of B.W. masonary valve chamber of size (1.20X0.90X1.50)m size
Supply all materials & construction of Thrust Block where required
Distribution System
Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authority and Providing all labour, materials, equipment to procure and laying of pipes for distribution main .
Earth work in excavation (As per IS. 3114/1965) for laying of different types and sizes of pipes so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of Engineer in charge (Classification soil item B) - 70% of excavated earth.
Earth work in excavation of foundation trenches as per design section in ordinary or soft rock (where blasting is not required and disposal of excavated materials so obtained (50 m away from the edge of the trenches ) with initial lead of 10 m and initial lift of 1.5 m as per specification amnd direction of E/I.
Supplying tool cutting road as well restoring the same as per specification and direction of E/I
Pucca road-
Water Bound Macadam Road-
Dismentaling plain cement or lime concrete work including stacking servicable materials in countable stacks within 15 meter lead and sisposal of unservicable materials with all leads all complete as per direction of E/I.
Providing PCC M-150 in nominal mix of (1:2:4) in foundation with approved quality of stones chips 20 mm - 6mm size graded and clean coarse sand FM 2.5 to 3.0 including screening shuttering mixing cmenet concrete in mixer and placing in position vibrating striking curing taxes and royalty all complete as per building specification and direction of E/I.
Earth work in backfilling the trenches after lying of different types and sizes of pipes with earth removed during excavated within initial lead and lifts as per specification and direction of Engineer in charge.
Supplying centrifugally cast (spun) Ductile iron pressure pipes for water supply with socket and Spigot ends conforming to IS 8329/2000 in standard working lengths of class K-7 suitable for push-on-joint (Rubber gasket D jointing ) with cement morter lining inside surface and outside zinc coating with bituminous paint including all other taxes, insurance carriage to work site with loading unloading etc. stacking including inspection charges and all taxes all complete( including cost of rubber gasket along with each pipe .)
100 mm dia pipe
150 mm dia pipe
200 mm dia pipe
250 mm dia pipe
110 mm dia HDPE (PE 100-PN10)
90 mm dia HDPE (PE 100-PN10)
75 mm dia HDPE (PE 100-PN10)
63 mm dia HDPE (PE 100-PN10)
Providing and supplying lSI standard D.I.specials & fitting with sealing rubber gasket of S.B.R. complete with cast iron follower gland and M.S. nut & bolts coated or otherwise protected from rusting and suitable for 0.1. pipes including cost of all labours and materials and transportation to stores 1 site, loading, unloading including all taxes,etc . complete as per I.S. 9523
Supplying labours, tools , tackles, lubricant etc for laying and jointing C.I.S/S Tyton pipes (class L A/DI) trenches supplying rubber gasket (Rubber gaskets confirming to I.S.S.-5382-1969) and making gasket joints including providing night guard ,barrier and red light to safe guard against accident ,all complete ( Pipe to be supplied departmentally free of cost and laying of pipes is to be done as per (I.S.S.3114-1985) as per design, specification and direction of E/I.
100 mm dia pipe
150 mm dia pipe
200 mm dia pipe
250 mm dia pipe
110 mm dia HDPE (PE 80-PN10)
90 mm dia HDPE (PE 80-PN10)
75 mm dia HDPE (PE 80-PN10)
63 mm dia HDPE (PE 80-PN10)
Supplying labour tools and tackles for testing of Laid CI or UPVC or HDPE or AC or DI pressure pipe up to 60 mm meter head of water all complete as per specification and direction of engeneer- in- charge. Water to supplied free of cost departmentally.
100 mm dia pipe
150 mm dia pipe
200 mm dia pipe
250 mm dia pipe
110 mm dia HDPE (PE 80-PN10)
90 mm dia HDPE (PE 80-PN10)
75 mm dia HDPE (PE 80-PN10)
63 mm dia HDPE (PE 80-PN10)
Labour charge for one cutting of cast iron pipe and specials including necessary tools and plants , chipping of filling surface finish as per specification and direction of E/I
100 mm dia pipe
150 mm dia pipe
200 mm dia pipe
250 mm dia pipe
110 mm dia HDPE (PE 80-PN10)
90 mm dia HDPE (PE 80-PN10)
75 mm dia HDPE (PE 80-PN10)
63 mm dia HDPE (PE 80-PN10)
Providing Double Flanged Sluice valve confirming to IS 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps including all taxes transportation etc. complete. (without by pass arrangement PN 1.6)
Sluice Valve-Dia100 mm
Sluice Valve-Dia150 mm
Sluice Valve-Dia 200 mm
Sluice Valve-Dia 250 mm
Scour Valve-Dia 100 mm
Supplyng labour and tools for fixing CI/DI sluice valve in trenches with a pair of C.I Tail pieces incluidng making lead caulked joints and flenged joints as per I.S specification, including supplying all jointing materials (Pig lead confirming to I.S.S 782-1978, yarn confirming to I.S.S 6587-1972 and nuts and volts confirming to I.S.S 1364-1983) including drillig holes in flanges if required as per specification and direction of E/I.
Sluice Valve PN 1.6-100 mm Dia
Sluice Valve PN 1.6-150 mm Dia
Sluice Valve PN 1.6-200 mm Dia
Sluice Valve PN 1.6-250 mm Dia
Scour Valve 100 mm Dia
Construction of B.W. masonary valve chamber of size (1.20X0.90X1.50) m size
Supply all materials & construction of Thrust Block where required
BOUNDARY/ COMPOUND WALL (352.80 M)
Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authority Construction of Compound wall. etc. all complete job.
Earth work in excavation in foundation trenches in hard soil (vide classification of soil item B) and disposal of excavated earth so obtained to a distance upto 50 M including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I. Excavation Qty.
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I.(Mode of measurement compacted volume).
Providing designation of 75A one brick flat soling, joints filled with local sand including cost of watering, taxes royalty all complete as per building specification and direction of E/I.
Providing P.C.C M - 150 with nominal mix of (1:2:4) in foundation with approved quality of stone metal grade - III ( 50mm to 25mm size) clean course sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I. Qnty in Foundation:
Centering and Shutting
Providing R.C.C M - 200 with nominal mix of (1:1.5:3) in foundation with approved quality of stone metal grade - III ( 50mm to 25mm size) clean course sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I. Qnty in Foundation:
Centering and Shutting
Providing R.C.C M - 200 with nominal mix of (1:1.5:3) in Stiffners with approved quality of stone chips 20 mm to 6mm size graded and clean course sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing(but excluding the cost of reniforcement , taxes and royalty all complete as per building specification and direction of E/I.
Centering and Shutting
Providing R.C.C M - 200 with nominal mix of (1:1.5:3) in band at plinth level with approved quality of stone chips 20 mm to 6mm size graded and clean course sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing(but excluding the cost of reniforcement , taxes and royalty all complete as per building specification and direction of E/I.
Centering and Shutting
Providing R.C.C M - 200 with nominal mix of (1:1.5:3) in band at lintel level with approved quality of stone chips 20 mm to 6mm size graded and clean course sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing(but excluding the cost of reniforcement , taxes and royalty all complete as per building specification and direction of E/I.
Centering and Shutting
Providing designation 75 A brick work in CM (1:6) in super structure with approved quality of clean coarse sand of FM 2 to 2.5 including, providing 10mm thick mortar joints cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Qnty. Wall
Providing 12mm thick cement plaster (1:6) with clean coarse sand of FM 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direction of E/I.
Qnty.Wall
providing two coats of snow cerm of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper , scaffolding,curing and taxes all complete as per building specification & direction of E/I. .
Providing Tor steel reinforcement of 10 mm ,12 mm , &16 mm dia Bars as per approved design and drawing excluding carriage of M.S bars to work site , cutting ,bending and binding with annealed wire with cost of wire ,removal of rust , Placing the rods in position all complete as per building specification and direction of E/I
Filling in foundation trenches and plinth in layers not exceeding dressed with earth obtained from excavation of foundation trenches with lead of 50m and lift of 1.5 M all complete as per building specification & direction of E/I
Carriage of construction materials to work site including loading, unloading & stacking etc. all complete.
Cement 10 KM lead
Steel 10 KM lead
Sand 36 KM lead
Bricks 6 KM lead
Stone/Stone Chips 11 KM lead
Cost of Gate (2 Nos)
Earth work in excavation in foundation trenches in hard soil (vide classification of soil item B) and disposal of excavated earth so obtained to a distance upto 50 M including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I. Excavation Qty.
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I.(Mode of measurement compacted volume).
Providing designation of 75A one brick flat soling, joints filled with local sand including cost of watering, taxes royalty all complete as per building specification and direction of E/I.
Providing P.C.C M - 150 with nominal mix of (1:2:4) in foundation with approved quality of stone metal grade - III ( 50mm to 25mm size) clean course sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I. Qnty in Foundation:
Centering and Shuttring
Providing R.C.C M - 200 with nominal mix of (1:1.5:3) in foundation with approved quality of stone metal grade - III ( 20mm to 6mm size) clean course sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
Centering and Shuttring
Providing R.C.C M - 200 with nominal mix of (1:1.5:3) in Column with approved quality of stone metal grade - III ( 20mm to 6mm size) clean course sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
Centering and Shuttring
Providing R.C.C M - 200 with nominal mix of (1:1.5:3) in Band at Plinth level with approved quality of stone metal grade - III ( 20mm to 6mm size) clean course sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
Centering and Shuttring
Providing Tor steel reinforcement of 10 mm ,12 mm , &16 mm dia Bars as per approved design and drawing excluding carriage of M.S bars to work site , cutting ,bending and binding with annealed wire with cost of wire ,removal of rust , Placing the rods in position all complete as per building specification and direction of E/I
filling in foundation trenches and plinth in layers not exceeding dressed with earth obtained from excavation of foundation trenches with lead of 50m and lift of 1.5 M all complete as per building specification & direction of E/I
Supplying fitting & Fixing M.S grill gate with M.S grills made 20x6mm M.S flat or 16mm M.S square bars fitted 25x25x6mm M.S angle farme of size 60x60x6 mm including cost of fabrication,providing necessary locking arrangement with haskal and domny duly fixed in P.C.C (1:2:4) blocks of required size, applying a priming red lead paint over steel work , taxes all complete as per direction of E/I.
Providing two coats of painting with ready mixed paint of approved shade and make over steel surface
Carriage of construction materials to work site including loading, unloading & stacking etc. all complete.
Cement 10 KM lead
Steel 10 KM lead
Sand 36 KM lead
Bricks 6 KM lead
Stone/Stone Chips 11 KM lead
Staff Quarters
Doing Geotechnical survey, Collecting field data, designing aesthetically, getting it approved by competent authority and Provision of twin type Staff Quarter etc. all complete job.
E / W in excavation in foundation trenches in ordinary soil (vide classification of soil item - A ) and disposal of excavated earth obtained to a distance upto 50 M including all lift leveling, ramming the foundation trenches removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I.
Providing, coarse clean sand in filling in foundation trenches/ in plinth including ramming & watering in layers not exceeding 150mm thick with all leads, including cost of materials, labour, royalty & taxes all complete as per building specification & direction of E/I. (mode of measurement compacted volume).
Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
Providing P.C.C.M -100 with nominal mix of (1:3:6) in foundation with approved quality of stone metal grade- III (50 mm to 25 mm size) clean coarse sand of F.M.2.5 to 3 including screening, shu ttering , mixing cement concrete in mixer & placing in position, vibrating, striking, curing, taxes & royalty all complete as per building specification & direction of Engineer-in-charge.
Providing designation 75A brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, costs of screening, materials, scaffolding, raking out joints to 15 mm depth curing, taxes & royalty all complete as per building specification & direction of E/I.
Providing 25 mm thick damp proof coarse with cement concrete M-150 with nominal mix of (1:2:4) with approved quality of stone chips of 20 mm to 6 mm size graded and clean coarse sand of F.M.2.5 to 3 including screening, shuttering, mixing cement concrete in mixer with 5 % cico or any other approved water proofing compound and placing in position, striking, curing, taxes & royalty all complete as per building specification & direction of E/I.
Providing designation 75 A brick work in C.M. (1:6) in Superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening, materials scaffolding, raking out joints to 15 mm depth curing, taxes & royalty all complete as per building specification & direction of E/I.
Providing R.C.C.M -150 with nominal mix of (1:2:4) in lintel with approved quality of stone ships 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, centering, shuttering, mixing cement concrete in mixer & placing in position vibrating, striking, curing (but excluding the cost of reinforcement), taxes & royalty all complete, as per building specification and direction of E/I.
Centering & Shuttering
Providing average 63 mm thick R.C.C.M-150 with nominal mix of (1:2:4) chajja with approved quality of stone chips 20mm to 6mm size graded & clean coarse sand of F.M. 2.5 to 3 including making drip course in concrete, screening, centering, shuttering & mixing cement concrete in mixer & placing in position vibrating, striking, 6 mm cement plaster (1:4) in ceiling & sides of chajja with sand of F.M. 1.5, curing (but excluding the cost of reinforcement ) taxes and royalty all complete as per building specification of E/I.
Centering & Shuttering
Centering & Shuttering
Providing R.C.C. M-200 with nominal mix of (1:2:4) in roof slab with approved quality of stone chips 20 mm to 6 mm size Graded & clean coarse sand of FM 2.5 to 3 including screening, centering, shuttering, mixing cement concrete in mixer & placing in position, vibrating, striking, curing (but excluding the cost of reinforcement) taxes & royalty all complete as per building specification & direction of the E/I.
Centering & Shuttering
Supplying, fitting & fixing good quality, well dressed & well seasoned sal wood work in chaukhat in doors, windows, skylights, fanlights and C/W celestial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls & lintels all complete as per building specification & direction of the E/I.
Supplying fitting and fixing 250 x 20 x 6 mm L-type M.S. Clamp properly fish tailed, including making holes and setting the same in 375 x 125 x 75 mm cement concrete block (1:2:4) with cost of all labour and materials and taxes as per building specification and direction of E/I .
Supplying fitting & fixing 38mm thick good quality well dressed and well seasoned Sal wood battened shutter ledged & braced in doors and windows with oxidized iron fitting such as hinges, sliding door bolts, tower bolts, handles or rings, hooks and eyes, cleats, sand block as per schedule, taxes & royalty all complete as per building specification & direction of E/I.
Supplying, fitting & fixing M.S. Grill made of 20 x 6mm M.S. Flat as per approved design & drawing properly fabricated with Joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per the building specification and direction of E/I. (where materials is not supplied by the Deptt.)
Providing 25 mm thick precast R.C.C. M-150 with nominal mix of (1:2:4) jali with approved quality of stone chips of 6 mm nominal size and clean coarse sand of FM 2.5 to 3 with 1.6 mm thick M.S. wire as per approved design and drawing and placing the same in position true to plumb and level and properly grouted with cement mortar (1:3) including cost of curing, scaffolding and finishing all complete as per building specification and direction of E/I.
Providing and fixing fan hook of 16 mm dia M.S. bar 1 meter long bent to required size and shape, placed in position and fixing in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where material is not supplied by Deptt.).
Supplying fitting and fixing M.S. grill gate with M.S. grills made of 20 x 6 mm M.S. flats or 16 mm .M.S. square bars fitted on 25 x 25 x 6mm. M.S. Angle frame of size 60 x 60 x 6 m m including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. (when steel is not supplied by the Deptt.)
Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding, taxes & royalty all complete as per building specification & direction of E/I.
Providing 12 mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, Curing with all leads & lifts of water, scaffolding, taxes and royalty all complete as per building specification & direction of E/I.
Providing cement 1:3 (12mm ) plaster with cement mortar (1:3) using clean coarse sand finishing with neat punning a dado 6" (150 mm) high a side room and out side wall upto plinth level includng screening , curing with all leads & lifts of water , scaffolding , taxes and royalty all complete as per building specification & direction of E/I
Earth work in filling in foudation trenches & Plinth in layers not exceeding 150 mm thick well watered ,rammed ,fully compacted & fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 m & lift of 1.5 m all complete as per building specification & direction of E/I ( Mode of measurement compacted volume)
Provliding average 150 mm thick dry rammed khoa beaten to 112 mm. ( compacted with water ) made of well burnt or jhama bricks includingramming properly tillcompacted thickness is achieved, curing & carriage of water with all leads, making proper slope & blending the top with cement mortar ( 1 : 10 ) all complete as per building specification & direction of E/I.
Providing 25 mm thick . First class patent stone flooring (1:2:4) with stone chips in two layers ,bottom layer 19 mm thick (1:2:4) with 12 mm to 6 mm size graded stone chips and top layer 6 mm thick (1:2) with 6 mm down stone chips in pannels including cost of curing , finishing the surface smooth by rubbing with carborandum stone taxes & royalty with all complete as per building specification & direction of E/I
Providing designation 75 A one brick on edge flooring in C.M (1:4) with top surface flush pointed in CM (1:4) approved quality of clean coarse sand of F.M 2 to 2.5 including the cost of screening ,raking out joints to 15 mm depth , curing taxes,royalty all complete as per building specification and direction (E/I)
White washing three coats over new surface with approved quality of lime including the cost of cleaning surface thoroughly and removing the scales & mosh marks with jhama rubbing, scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
Color washing two coats over a coat of white wash over new surface with approved quality of lime in approved shade including the cost of cleaning surface thoroughly and removing the scales & mosh marks with jhama rubbing, scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
Providing two coats of synthetic enamel paint of approved shade and make over new wooden surface including cleaning the surface after removing dirt, scales, smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification & direction of E/I
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning , removing rust ,dirt ,scales ,smokes and grease and cleaning the surface thouroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I
Providing two coats of synthetic enamel paint of approved shade & make over steel surface including cleaning the surface thoroughly, scaffolding & taxes all complete as per building specification & direction of E/I.
Providing tor steel reinforcement of 8 mm dia as per approved design and drawing excluding carriage of bars to work site ,cutting, bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per Specification and direction of E/I.TMT Fe 500 (Only valid for SAIL and TATA )
Carriage of construction materials to work site including loading, unloading & stacking etc. all complete.
Cement 10 KM lead
Steel 10 KM lead
Sand 36 KM lead
Bricks 6 KM lead
Stone/Stone Chips 11 KM lead
Water Supply Sanitation Installation (Plumbing work)
Supplying and laying GI pipes of approved make in trenches with red lead and yarn with socket and screw joints and cutting pipes in size and threading ends where necessary including carriage of materials up to work site etc. all complete as per specification and direction of E/I.
i) 25mm GI. Pipe.
ii) 15 mm GI. Pipe.
Supplying materials and labours for fixing GI Pipes with red lead paints and yarn with screwed and sockted joints on wall, celling and floor including supplying of wall hooks of pipe clamp, wooden plugs, cutting pipe to size and threading ends where necessary all complete as per specification and direction of E/I.
i) 15 mm GI. Pipe
Supplying, fitting and fixing of GM ferrule of approved make in DI/CI main including drilling and tapping CI/DI main etc. all complete as per specification and direction of E/I.
Supplying and fixing GI fittings of approved make all complete as per direction of E/I.
(a) Elbow 15 mm dia
(b) Tee plane 15mm dia
(c) Nipple 15mm dia.
(d) Union Socket 25mm dia
(e) Union Socket 15mm dia
(f) Brass bib cock 15mm dia
(g) C.I stop cock 15mm dia
(h) C.I. stop cock 25mm dia
(i) Reducing Socket 25x15mm
(j) Tee 25x25x15mm dia
Supplying, fitting and fixing vitreous white glazed earthen were I W C of parry Hindustan or any other I.S.S approved make with 100 mm HCI ‘P’ trap, 15 Liters CI pull and let go flushing cistern of names or other ISS equivalent make complete with all fittings C.I. or C.C brackets, 32 mm, alkathene /PVC telescopic flush pipe about 2 mtrs. long with one brass coupling and clamps, GI chain and pull including supplying and fixing a pair of vitreous white glazed earthen were footrest to be fixed in floor, 15 mm .CI body brass spindle, stop cock of weight not less than 50 grams, 15 mm. PVC connection pipe 450 mm. long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. (510mm.long with 12.5 Liter low level PVCSystem).
SEPTIC TANK and SOAK PIT
Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item-B) and disposal of excavated earth as obtained to a distance up to 50 m including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I.
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of E/I.
Providing designation 75A one Brick flat soling, joints filled with local sand including cost of watering, tax, royalty all complete as per building specification and direction of E/I.
Providing P.C.C M150 with nominal mix of (1:2:4) in foundation with approved stone chips 20mm to 6mm size well graded and clean course sand of FM-2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, Vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing water proof cement plaster (1:3) with clean course sand of F.M- 1.5mm with 5% cico or any other approved water proofing compound including taxes and royalty all complete as per building specification and directions of E/I.
(a) 19 mm thick
(b) 12 mm thick
Providing designation 75A bricks work in C.M. in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints, cost of screening materials racking out joints to 15 mm. depth, curing taxes and royalty all complete as per building specification and direction of E/I.
(a) B/W in C.M (1:4)
(b) B/W 75-B in (1:6) for Soak pit
(c) Brick work in dry masonry for soak pit.
Providing pre cast R.C.C. M-150 with nominal mix of (1:2:4) slab of desired size with approved quality of stone chips and clean coarse sand of FM 2.5 to 3 including curing, shuttering, carrying the slab manually to site and laying in position all complete (but excluding the cost of reinforcement), taxes and royalty etc. all complete as per building specification and direction of E/I.
Providing Tor reinforcement as per approved design and drawing excluding carriage of tor rod to work site including cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per Specification and direction of E/I.
10 mm dia
Supplying fitting and fixing H.C.I. Pipe/ H.C.I. fitting of Approved make confirming to I.S.S 1729 including supplying nails and bobbins lead and yarn from making lead caulked joints including earth work or providing scaffolding as the case may be all complete as per specification and direction of E/I.
(a)100mm dia H.C.I. Tee.
(b) 100mm dia H.C.I. Band
(c) 50mm dia H.C.I. Cowel
(d) 50mm dia H.C.I. Vent pipe
(e) 100mm H.C.I. Pipe
Supplying materials and labours and fixing 20mm dia M.S bar steps in wall of 0.3 m interval and staggered in (1:2:4) cement concrete including scaffolding and curing etc. all complete as per specification and direction of E/I.
Supplying all materials, labours, tools and tackles and 100mm dia R.C.C hume pipe and laying jointing, testing, earth work including carriage of materials etc. all complete.
Supplying 50mm size brick bats and filling in soak pit including carriage and labours etc. all complete as per direction of E/I.
Supplying materials and labours for constructing inspection chamber of designation class 75 B bricks size 750mm deep, 600x450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600x475 mm G.I. Cover With frame ( Weight not less than 36 Kg.) along with earth work in excavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I
Carriages of materials
(a) Brick –6 KM lead
(b) Sand -36 KM lead
(c) Stone chips -11 KM lead
(d) Steel 10 KM
(d) Cement- 10 KM lead
Electrical Works
Point wiring in PVC conduit with modular type switch wiring for light point /fan point with 1.5 sqmm F.R. PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular switch modular plate, suitable G.I. box and the point with sqmm FR PVC insulated copper conductor single core cable etc as required
Wiring for twin control light point with 1.5 sqmm F.R. PVC insulated copper conductor single core cable in surface/recessed PVC conduit with two way modular switch modular plate, suitable G.I. box and the point with sqmm FR PVC insulated copper conductor single core cable etc as required
Wiring for light /power plug point with 2 x 4 sqmm F.R. PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with one no 4 sqmm FR PVC insulated copper conductor single core cable for loop earthing etc as required
Copper sub main wiring in PVC conduit Wiring for sub main wiring with PVC insulated copper conductor single core in surface/recessed PVC conduit as required
2 x 1.5 sqmm + 1 x 1.5 sqmm earth wiring
2 x 2.5 sqmm + 1 x 2.5 sqmm earth wiring
Supplying and fixing following way three pole and neutral sheet MCB distribution board 415 volts on surface/recessed complete with tinned copper bush bars ,neutral link, earth bar, din bar, detachable gland plate inter connection phosphatised and power painted including earthing etc as required (but with out mcb / rccb / Isolator) (4 +12 ) double door horizontal type
Supplying and fixing 5 amp to 32 amp, rating 240 volts, B series miniature circuit breaker of single poles in existing MCB DB complete with connecting ,testing, and commissioning etc as required
Earthing with G.I. earth pipe 4.5 M long 40mm dia including accessories and providing masonry enclosure with copper plate having locking arrangement and watering pipe etc with charcoal ,salt all complete as per electrical rule
Supplying ,fitting and fixing following sizes of PVC conduct along with accessories in surface / races including cutting the wall and making good the same in case of recessed conduit as required
PVC con 20 mm PVC pipe
PVC con 25 mm PVC pipe
Installation commissioning and testing Ceiling Fan
Carriage of ceiling fan and regulator
Supplying ,fitting and fixing 5 amp ceiling rose on the existing junction
Supplying ,fitting and fixing breas batten/ angle holder including connection etc.
Supplying ,fitting and fixing G.I. box with modular plate and cover in front of surface or in recess including providing and fixing 3 pin 5/6 amp modular type switch, connection, painting etc as required.
Supplying ,fitting and fixing G.I. box with modular plate and cover in front of surface or in recess including providing and fixing 6 pin 5/6 amp and 15/16 amp socket outlet and 15/16 amp modular type switch, connection, painting etc as required.
Supplying and drawing co-axial T.V. cable RG-06 grade 0.7 nn solid copper conductor PE insulated seilded with fine tinned cover braid and protected with PVC sheath in the existing surface / recessed steel/ PVC conduit as required.
Supplying and fixing modular switch / socket on the existing modular plate and switch box including connection but excluding modular plate etc,as required. TV antenna socket out put
Supplying ,fitting and fixing modular base and cover plate on existing modular metal boxes etc as required.
Cost of Earthing with G.I. earth pipe 4.5 M long 40mm dia G.I.Pipe 600mm x 600mm x 6mm thick copper earth plate, and 8 SWG copper wire including cost of making 1.2x1.2x3m deep pit and filling with charcoal ,salt all complete as per electrical rule
Approach road (100 meter)
Soil Excavation :- Excavation in soil by manual means. (Excavation of roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto 1000 m) including royality
Embankment :- Construction of embankment with approved meterial obtained from borrow pits with a lift 1.5 M transporting to site spreading,grading to required slope and compacting to meet requirement of to tables 300.1 and 300.2 with a lead upto 1000 M as per technical specification 301.5.
(A) By Mix in Place Method Construction of granular sub base by providing well graded material, spreading in layer with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with smooth wheel roller to achieve the desired density complete as per Technical Specification Clause 401
Cement Concrete Pavement :- Construction of un-reinforced dowel joints at expaction and construction joint only plain cement concrete pavement thickness as per design over a with shovels rakes compacted using prepared sub base with 43 grade cement or any other type as per clouse 1501.2.2 M-30 (grade) coarse not exceeding 25 mm mixed in concrete mixer of not less than 0.2 cum capacity and appropenate weigth bacher using approved mixed design laid in approved fixed side fromwork (steel channal laying and fixing of 125 micron thick polythene film wedges steel plates including leveling the fromwork as per drawing), spreading the concrete with shovels rankes compacted using needle seed and plate vibrators and finished in contaction and empanction contraction jointing appling debonding strips primer sealant dowel bars near approches to bridge/culvert and contraction joints admixtures as approved curring of concrete slabs for 14 days using curing compound (where specified) and water finishing to lines and grade as per drawing and technical specification clouse 1501
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per table 1300.1 no frament weighing less than 25 kg laid dry complete as per drawing and technical specification clause 1301
Carriage of material from divisional store are kiln side or quality side to work including contractor profit loading ,unloading transportation are complete .
Cement 10 KM lead
Sand 36 KM lead
Stone/Stone Chips 11 KM lead
House Connection = 3527 Nos
Earth work in excavation(as per IS 3114/1965 for laying of different types and sizes of pipes so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of E/I.(For soil item B)
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labours.royality and taxes all complete as per building specification and direction 0f E/I.(mde of measurement compacted volume)
Providing a PCC M-150 in nominal mix of(1:2:4)in foundation with approved quality of stone chips 20mm to including screening,shutteing,mixing cement concrete in mixer and placing a position,vibrating,striking,curing,taxes and loyality complete all as per building specification and direction of E/I
Providing Centaring & Shuttering including strutting, Propping etc &all Complete.
Earth work in backfilling the trenches after laying different types and size of pipes with earth removed during exacavation within initials leads and lifts as per building specification and direction of E/I
Providing 12 mm thick cement plaster (1:3) with clean coarse sand of F.M 1.5with 1.5 mm thick ceme punning over it including screenig,curing,wit all leads and lifts of as per building specification and direction of E/I.
Providing and supplying Blue MDPE pipes confirming to ISO 4427:1996 manufactured from vrgin resin PE 80 food grade compounded raw materials having blue colour only assurance certificate from quality agencies like WRC/CIPET(india)/DVM/KWA/SPGN etc for usage in drinking water with quality system. This cost shall include testing of all materials all taxes central, state, municipal, inspection charges transportation up to site, transit insurance, loading, unloading, stacking etc complete as specified and directed. PN16(SDR-9) with ED (20mm)
providing and supplying G.I. Pipes (tata and equivalent make) for usage in drinking water with quality system. The cost shall include testing of al materials all taxes central state, municipal , inspection charges transportation up to site, transit insurance, loading, unloading, stacking etc complete as specified and directed. (15mm)
Lowering laying and Jointing HDPE/MDPE pipes in proper position including all specials by compression fitting/electrofusion and but fusion jointing procedure including hydroulic testing as per relevent IS code complete with all materials for jointing procedures like Electrofusion C30machine, electric mirror/ heater / but fusion welding machine with hydraulic jack, top loading clamp etc. pump and accessories fro hydraulic testing and all labours as direted by E/I as per IS-7634 part-2 (20mm)
Supplying labours and tools fro fixing G.I. Pipes with red lead and yarn of following nominal bore with screwed and socketed joints on wall, celling and floor including supplying and fittings of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of E/I.
Supplying and fixing of G.M. Ferrule of approved make in existing C.I/D.I. Main including drilling and taping C.I./D.I. Main all complete as per specification and direction of E/I (3mm dia)
Providing and fixing of G.M. Fullway valve of approved quality all complete as per specification and direction of E/I (20mm dia)
Providing and fixing of male ended C.I. Body brass spindle valve and seat Bib cock of approved quality with extra socket all complete as per specification and direction of E/I (20 mm dia)
Supplying and fixing G.I. Fitting of approved make all complete as per specification and direction of E/I
20mm dia Elbow
15mm dia Elbow
20mm dia reducing socket
20 mm dia nipple
15 mm dia nipple
20mm dia union socket
15mm dia socket
20mm dia socket
Carriage of materials
Operation & Maintenance for Five years (excluding energy charge)
O/M work with Labour component & Materials for 1st Year
As per SBD Section - 5 Clouse 9.10
O/M work with Labour component & Materials for 2nd Year
As per SBD Section - 5 Clouse 9.10
O/M work with Labour component & Materials for 3rd Year
As per SBD Section - 5 Clouse 9.10
O/M work with Labour component & Materials for 4th Year
As per SBD Section - 5 Clouse 9.10
O/M work with Labour component & Materials for 5th Year
As per SBD Section - 5 Clouse 9.10
Labour Cess @ 1%
Shiv Jyoti Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.81 MB
SBD.pdf
Tender Documents • 2.15 MB
BOQ_84705.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid