Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC QURESHI BUILDING BUDSHAH CHOWK SRINAGAR 190001 KASHMIR J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹45.8 L+₹2.4 L (5.57%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest | |
| 3 | L3₹50.5 L+₹7.1 L (16.3%)Rejected-AOC 42 B INDRA NAGAR SRINAGAR J K 190004 | SRINAGAR | SRINAGAR | J K | 190004 | L3 | Rejected-AOC Other than Lowest | |
| 4 | L4₹52.7 L+₹9.4 L (21.6%)Rejected-AOC | L4 | Rejected-AOC Other than Lowest | |
| 5 | L5₹74.0 L+₹30.6 L (70.6%)Rejected-AOC | L5 | Rejected-AOC Other than Lowest |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
28 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 969 EWS
GE 969 EWS C/O 56 APO
PROVN OF CERTAIN SANCTION WORKS AT DIFFERENT LOCATIONS UNDER AOR OF GE 969 EWS
2023_MES_610172_1
CA NO 969 WS - /23-24
Open Tender
Civil Works
Item Rate
180 days
BARAMULLA
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 969 EWS
₹92,000
Yes
14 Oct 2023
21 Jul 2023
30 Aug 2023
21 Jul 2023
28 Aug 2023
5 Aug 2023
Amount
S&F Phase Prodigy (SECURE) Distribution Transformer Meter with built-in-current transformers, energy audit and system analysis, direct connected 3Ph Wire 415V with current range 40-200A, accuracy class 1.0, frequency 50 Hz, Insulation Class- Protection Class II, Impulse withstand 10 KV, IS-13779, Dimensions (W x H x D) 365 x 283 x 221mm (with extended terminal cover) all as specified and as directed.
M&L for cubical panel (dimension of meter to be fixed in Panel is 365 x 283 x 221mm for 3Ph Prodigy (Secure) Meter along with connected items like nuts & bolts, screws, binding wire, hold fast for fixing in wall/grouting incl XLPE UG Cable 95 Sqmm 3.5 Core from Transformer to meter and LT Panel all as specified and as directed.
Supply, installation, commissioning of Metal Top Deep Freezer of capacity 500 Ltr, single phase 240 volt, 50 Hz all as specified and as directed.
Supply and fix copper wound voltage stabilizer 2 KVA working range 170V-270V all as specified and as directed.
S&F and commissioning UPS for 30 min back up single phase AC input 160 to 260 V and output 230 ± 1 % of capacity 5 KVA alongwith battery, movable trolly with cabling 5 meter input and output complete including connected accessories complete all as specified and as directed.
Supply installation, testing and commissioning of Mild suitable Steel factory fabricated Pressure filter system to treat 864000 LTRS. Water per day in 16 hours operation (54000 LTRS per Hour). System should Include Two Nos vertical type pressure filters, each of capacity 27000 LTRS./Hour (6000GPH), made out of Mild steel sheets 8mm thickness shell, 8 mm dish and 12mm strainer plate, with manhole 450mm dia. 1 hand hole 200 mm dia. Strainer plate duly fitted with umbrella type PP strainers Filtration velocity not more than 15 mtrs/hr. having size of 1500mm Dia. x 1800mm Ht. having 80 mm frontal piping. Each filter to be provided with Cast Iron butterfly valves for raw water inlet, filtered water outlet, back wash water inlet backwash outlet, 50 mm air scouring valve, 25 mm air release ball valve, complete with pressure gauge and Sampling Cock on inlet and outlet of filter. The pressure filters shall be Painted internally with anticorrosive black bituminous paint and externally red oxide followed by gray synthetic enamel Paint. Filter media bed depth to be minimum 1050mm covering graded gravel of size 20-15mm, 15-10mm & quartz sand -8+16 mesh and suitable layer of Anthra cite and fine quatz sand -16+30 mesh complete all as specified and directed by Engr-in Charge. (Make : Chloromax)
Note : 1. The rate of pressure filter shall be deemed to include MS/GI Pipes as required on site during execution (suitable size) with inlet and outlet, including all Sluice/Butterfly/NRV valves of suitable size complete. 2. The rate shall be deemed to dismantle and take out old unsv pressure filter from site and to deposit in MES store and no extra payment shall be paid to the contractor. 3. T&P and labour shall be arranged by the contractor on site. 4. B/R wk shall be deemed to include in quoted rate of pressure filter as required on site during execution of work. No extra payment shall be made to the contractor for any B/R wk.
Supply installation, testing and commissioning of Centrifugal pump (2W+1S for each set total =3 Pumps sets) suitable for filter feed capacity of 27000 LPH at head of 18 mtr. & 42000 LPH at head of 10 mtrs. (for backwashing) with mechanical seal , but capacity not less than 3 HP rating, operating on 3 Phase 415 V, AC 50 Hz including valves for suction & delivery and NRV for delivery with MS base plate including suitable PCC foundation for motors complete all as specified and as directed.
Supply, installation testing and commissioning of Twin lobe air blower of capacity 100 CU.M /Hr. x 3.5 MWC pressure complete with TEFC electric Motor of suitable rating 3 Phase 415 V, AC 50 Hz. including necessary suction filter, common base frame butterfly type control valves & check valves complete all as specified and as directed.
M&L for earthing with galvanised iron earth plate electrode 600mm x600mmx 6mm thick burried directly in ground (Eart pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less |than 1.5 metres below normal ground level, inclusive galvanised iron strip 32x6mm as earth lead connected to earth plate electrode by means of bolts, nuts, check nuts and washers,earth wire protected with and including 40 mm bore light grade ISI marked GI pipe upto 7.5 meters long all as shown in electrical plate no 5 of MES schedule part-1,with and including PCC 1:2:4 type B1 pit with cover of RCC 1:2:4 type B1,reinforced with welded steel wire fabric not less than 4 kg per sqmtr with handle and angle iron frame,watering arrangment with 20 mm bore Gl medium grade pipe ISI marked, GI funnel with GI mesh, filling| with mixture of common salt and charcoal, necessary excavation, refilling, removing away spoil and earth work in any type of soil, including test point, testing and commissioning complete all as specified and as directed.
M&L for installation, commissioning & testing of LT panel board (Main Panel) outdoor type fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, double door type accessible from front and rear side both with locking arangement 3 phase 1.5 Sqmm sigle core copper wire system at AC 440 V, 50 HZ with colour coded aluminium bus bar of rated current capacity 400 Amp complete applied with two coats of synthetic enamelled paint over a coat of anti corrosion primer and mounted on angle iron of size 50x50x6 mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories: -
Supply and fabricated LT distrubution panel board with 3.15 mm thick CRCA sheet
Aluminium busbar 4 strip with Coloured R,Y,B & Neutral of size (32x6) mm.
Angle iron for frame work of size 50x50x6mm thick for panel mounting
(a) INCOMING
(i) Four pole MCCB 100 Amp,50 Hz 415 Volts with repturing capacity 25 KA WITH THERMAL MAGNETIC ADJUSTABLE TYPE. (INCOMING)
(iv) CTs ratio 63/5A class ISI marked (sets of three)
(v) Indicating lamp-01 (set of three)
(b) OUTGOING
(i) MCCB 4 Pole, 415 volts grade 32 Amps rating and 16 KA rupturing capacity - (03 Nos)
On Load change over switch 100 AMP 4 Pole- (01 No)
Fully automatic star delta starter 10 HP HGS series. - (03 Nos) (Havells Model No-IHHASDRA)
Dismantling old and unsv steel tublar poles of any type including breaking cement concrete complete and site clearance
Dismantling of cross arms of MS channel or angle sections etc complete all as specified and as directed.
Dismantling HT/LT OH line from the insulators complete all as specified and directed
Dismantling and taking down the existing LT/HT insulators of any type from any description
Dismantling & Taking out the existing old service cables off sizes complete all as specified and as directed.
Dismantling old UNSV existing LT panel with switch gears complete all as specified and as directed.
Dismantling & Taking out old UNSV earthing.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium Conductor of size 185 sq mm 3.5 core, complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium Conductor of size 120 sq mm 3.5 core, complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core, complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium Conductor of size 16 sq mm 4 core, complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core, complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire amoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium Conductor of size 25 sq mm 2 core, complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core, complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core, complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core, complete all as specified and as directed. Note : Item Ser No. 18 to 26 Earth wk, Sand cushioning and cable covers/Bricks for protection of cable shall be measured and paid separately under relevant items.
S&F in trench/on wall in repairs GI tubing light grade for road crossing and cable protection of the following sizes as in repairs :-
(a) 50 mm dia
(b) 80 mm dia
(b) 100 mm dia
Supply, lnstalling & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (Mandir) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 650 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :
(a) INCOMING
(i) MCCB 4 Pole 415 volts grade 400 Amps rating and 36 KA rupturing capacity - (01 No)
(iv) CTs ratio 400/5A class ISI marked (sets of three)
(v) Indicating lamp-01 (set of three)
(b) OUTGOING
(i) MCCB 4 Pole, 415 volts grade 160 Amps rating and 25 KA rupturing capacity - (02 Nos)
(ii) MCCB 4 Pole, 415 volts grade 125 Amps rating and 25 KA rupturing capacity - (01 Nos)
(iii) MCCB 4 Pole, 415 volts grade 100 Amps rating and 25 KA rupturing capacity - (01 Nos)
(iv) MCCB 4 Pole, 415 volts grade 63 Amps rating and 25 KA rupturing capacity - (01 Nos)
Supply, lnstalling & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (PH front side) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 500 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :
(a) INCOMING
(i) MCCB 4 Pole 415 volts grade 100 Amps rating and 25 KA rupturing capacity - (01 No)
(iv) CTs ratio 100/5A class ISI marked (sets of three)
(v) Indicating lamp-01 (set of three)
(b) OUTGOING
(i) MCB DP 10 TO 32 AMP - (12 Nos)
(ii) MCB DP 50 AMP - (01 No)
Supply, lnstalling & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (PH back side) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 200 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :
(a) INCOMING
(i) MCCB 4 Pole 415 volts grade 160 Amps rating and 25 KA rupturing capacity - (01 No)
(iv) CTs ratio 160/5A class ISI marked (sets of three)
(v) Indicating lamp-01 (set of three)
(b) OUTGOING
(i) MCCB 4 Pole, 415 volts grade 100 Amps rating and 25 KA rupturing capacity -(01 Nos)
(ii) MCB DP 10 TO 32 AMP - (06 Nos)
(iii) MCB DP 40- 63 AMP - (01 Nos)
(iv) MCB TPN 40- (01 Nos)
Supply, lnstalling & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (Adm Block) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 200 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :
(a) INCOMING
(i) MCCB 4 Pole 415 volts grade 125 Amps rating and 25 KA rupturing capacity - (01 No)
(iv) CTs ratio 125/5A class ISI marked (sets of three)
(v) Indicating lamp-01 (set of three)
(b) OUTGOING
(i) MCB DP 10 TO 32 AMP - (09 Nos)
(ii) MCB DP 40 TO 50 AMP - (01 Nos)
(iv) MCB TPN 50 AMP - (01 Nos)
Earthing complete with galvanised steel earth plate electrode of size 60cms x 60cms x 6.0 mm thick buried directly in to the ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to the galvanised earth strip 32 x6 mm by means of bolts, nuts thimble check nuts and washers of galvanised iron or steel usingGl including PCC (concrete chamber) 1:3:6 Type C-1 using 20 mm graded stone aggregate with fair finish of internal surface concrete, 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68 mm) 8 mesh per inner inch, 80mm thick RCC Pit cover 320mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM and charcole dust and common salt all as shown in electrical plate No-3 MES SSR Part-l and specified including provision of earth wirel strip protected by 40 mm dia medium grade Gl pipe including all excavation and earth work & connecting the earth earthing to an earthing test point/ transformer neutral/ body LT panel etc and testing on complete, complete all as specified and directed Note :- Quoted rate of earthing shall be deemed to included cost of 7.5 M long galvanised iron strip 32X6 mm and protection pipe of 40mm bore medium grade, GI light grade 20mm bore watering pipe.
Supply and fixing RCC cable route marker for LT complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth,for foundations, laying of pipes etc not exceeding 10sqm on plan for mamholes etc and not exceeding 1.5 metre in depth and getting out in any type of soil, complete all as specified and as directed.
Retuning, filling in, including spreading, leveling watering and well ramming in layers not exc 25cm in hard/dense soil, complete all as specified and as directed.
Removing excavated material not exceeding 50mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and as directed.
Supply and laying of burnt clay building bricks, sub-classB (old size) Designnation 75 laid flat in tranches for cable protection with wide equal to length of brick, complete all as specified and as directed.
M&L for dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15cm thick after laying the cable all as specified in clause 19.75 of MES schedule part-1 Note:- Sand shall be fine sand as specified for plastering, Punned thickness of sand shall be measured for cushioning of cables.
M & L Sub main wiring with two run single core 6 Sqmm FRLS Copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC conduit/casing caping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed. Note: Two runs of 6 sqmm and one run of 6 sgmm cable and one run of casing capping shall be measured as one RM
S&F loopin loopout fuse junction box of made out of thermo plastic Polycarbonate with IP 66/67 weather proof for outdoor installation (with knockouts of cable entry) protection with terminals and locking screw fitted with 3 phase with neutral copper Bus Bar, 415 Volts, 5OHz and 6A MCB SP suitable for cables off sizes and fixing on steel tubular pole at a height not less than 1.5m above around level with the help of clamps two nos of F1 20 x3 mm and suitable nuts and bolts, complete all as specified and as directed.
S&F 60 W LED New qeneration energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source and electronic driver suitable for pole dia up to 58 mm, complete all as specified and as directed.
S&F LT End termination Joint Kit 1100 V Grade suitable for XLPE cable Of size 6 to 25 Sqmm 4core, complete all as specified and as directed.
S&F LT End termination Joint Kit 1100 V Grade suitable for XLPE cable Of size 35 to 70 Samm 4core, complete all as specified and as directed.
S&F LT End termination Joint Kit 1100 V Grade suitable for XLPE cable Of size 95 to 185 Samm 4core, complete all as specified and as directed.
Supply, install, testing and commissioning of Kero cum Electric based water heating plant of capacity 500 Litres including accessories i,e inlet/oulet pipes, thermostat, glass wool insulated oil burner including fuel storage tank of capàcity 150 Ltrs, proper cover shed suitable for the boiler for operating Kero-cum-Electric based water heating plant with full efficiency complete all as soecified and directed by Engr-in-Charge Note:- 1. The cost of Foundation and Shed is deemed to be included in quoted rate. 2. One year warranty period is included in quoted rate
S&F 1000 Itrs capacity Rotational moulded polyethylene in white coloured three layered ISI Marked water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
S&F 32 mm PP-R Gate valves (brass insert) as per requirement complete all as specified and as directed.
S&F 20mm PP-R Gate valves (brass insert) as per requirement complete all as specified and as directed.
S&F 32mm 3-layer PP-R Polypropylene random copolymer) concealed p1pes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water suppiy including ali PP-R plain & brass threaded p o lypropylenerancom fittings fixed complete laid in tranches, walls, ceilings or in floors including all fitting and fixtures such as tee, bend, elbow, union, nipple, reducer etc with necessary clamp and screw complete all as specified and as directed.
S&F 20mm 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p ol ypropylenerandom fittings fixed complete laid in tranches, walls, ceilings or in floors including all fitting and fixtures such as tee, bend, elbow, union, nipple, reducer etc with necessary clamp and screw complete all as specified and as directed.
M&L for lagging on 32/20mm internal dia pipe all round with 25 mm thick bonded mineral wool pre-formed 'SNAP ON' pipe section of density of 144 Kg/Sqcm confirm to IS 9842 including providing with chicken mesh wire netting 25 gauge 20 mm mesh etc complete all as specified and as directed.
M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, Screws guttier/plug etc PVC unsheathed cable into and includina wooden board with bakelite sheet and PVC insulated FRLS cable of size 25 Samm as earth continuity conductor.
S&F switch piano Flush type, single pole16 amp 240 volts, complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete all as specified and as directed.
S&F 1100 V grade heavy duty cable with pvc insulated aluminium conductor served with inner sheathing of pvc tape and overall pVc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire one twin core cable flat or circuiar of size 16 sqmm complete all as specified and as directed.
S&F voltage stabilizer copper wound of capacity 4 KVA working range 150V-270V complete all as specified and as directed.
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and as directed.
M&L for PCC 1:3:6 type C-2 in foundations, filling and mass concrete, complete all as specified and as directed.
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles as necessary gusset plates. riveting. etc confroming, to Fe. 290 Gde E-165 complete all as specified and as directed.
S&F 6mm thick Plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming with riveted, bolted or welded attachment confirming to Fe-290 (Gde E 165) etc complete all as specified and as directed.
Preparation of new or previously untreated steel surfaces of any description, over 10cm in : width or girth, not otherwise described and apply two coat of synthetic enamel paint over a coat of red oxide, complete all as specified and as directed.
Note:- Schedule of credit Rs 37,545.00/- will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
M/S NORTHERN ELECTRICAL WORKS
M/S ZENITH TRADE LINK
M/s Shabir Ahmed Mir and Bros
M/S KULWANT SINGH RAINA AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .