GEMC-511687735811799
Awarded to International Scientific & Surgicals
₹3.1 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| iMark Microplate Absorbance Reader (Elisa Plate Reader) | Bio-Rad (168-1130) iMark | - | 1 NOS | ₹3.1 L | 312,700 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.1 LQualified Make: BIO RAD
Model: Bio-Rad (168-1130) iMark SOLAN HIMACHAL PRADESH 173212 | SOLAN | HIMACHAL PRADESH | 173212 | Make: BIO RAD
Model: Bio-Rad (168-1130) iMark | ₹3.1 L | L1 | Qualified |
| 2 | L2₹3.3 L+₹16,300 (5.21%)Qualified Make: BIO RAD
Model: Bio-Rad (168-1130) iMark ANALYTICAL HOUSE E67 E68 RAVI PARK VASNA ROAD BARODA GUJARAT 390 015 | BARODA | VADODARA | GUJARAT | 390015 | Make: BIO RAD
Model: Bio-Rad (168-1130) iMark | ₹3.3 L+₹16,300 (5.21%) | L2 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
30 Aug 2018, 12:00 pmClosed
SPECTROPHOTOMETER ( PAC Only ) Average Turn Over of Last 3 Years 12 Lakh (s) Experience with Gov. Required 5 Year (s) SPECTROPHOTOMETER ( 1 ) ( Under PAC ) Make biorad Model bio-rad(168-1130)imark Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values TYPE Type of Spectrophotometer UV - VISIBLE UV - VISIBLE
VISIBLE
UV - VISIBLE - IR Type of Optical System Split Beam Single Beam
Split Beam
Double Beam Monochromator Type NA Reflexive Grating
Holographic Grating
Czerny-turner
NA Detector Type Photodiode Photo Multiplier Tube (PMT)
Photodiode
CMOS
Diode array Spectral Bandwidth Type Fixed Bandwidth Fixed Bandwidth
Variable Bandwidth LIGHT SOURCE Light Source Tungsten Halogen Lamp Halogen Lamp
Deuterium Lamp
LED
Tungsten Halogen 1/5 Lamp
Xenon Flash Diffraction Grating (lines/mm) 600 600
800
1000
1200
1400
1600
1800 Switching of Light Source Automatic Automatic
Mannual Wavelength Setting And Scanning Automatic Automatic
Mannual OPTICAL PERFORMANCE Source Wavelength - Minimum 340 175
180
185
190
195
200
320
340 Source Wavelength - Maximum 760 * (or higher) Resolution 2 0.002
0.3
0.5
1
1.25
1.5
1.7
2 Wavelength Accuracy (+/-) 0.8 0.1
0.8
2
2.5 Bandwidth (nm) 0 to 5.0 0.1
0.2
1.8
2.0
4.0
5.0
0 to 5.0 If variable band width
Specify the incremental step value(mm) NA * Scanning Speed (nm/min) 1000 * Focal length (mm) 50 to 99 0 to 49
50 to 99
100 to 149
150 to 199
200 to 249
250 to 299
300 and above Photometric measurement modes Absorbance Transmittance
Absorbance
Concentration (Wavelength
time)
Reflectance
Energy
Polarisation Photometric Absorbance (Max) (Abs) (+/-) 0.27 0.2-8 Photometric Absorbance Accuracy (Max) (+/-) 0.35 0.001-0.5 Photometric Transmittance (Max) (+/-) 90 Any applicable numeric value Photometric Transmittance Accuracy (Max) (+/-) 0.35 Any applicable numeric value Photometric Reflectance (Max) (+/-) 86 Any applicable numeric value Photometric 0.35 * 2/5 Reflectance Accuracy (Max) (+/-) Stray Light Correction Automatic * Baseline Correction Automatic * GENERIC Display In-built display In-built display
Through PC Display type LCD with Backlight LCD with Backlight
LCD touchscreen
TFT
NA Display Size 2.5 Any applicable numeric value Test result printing Through inbuilt Printer Through inbuilt Printer
Through external printer If inbuilt printer
Type of printer Thermal printer Thermal printer
Dot matrix
Laser b/w
Inkjet b/w
Color laser
Color inkjet
N/A Suitable software for connecting PC & Printer Yes * Connectivity USB
RS 232 * Internal storage(GB) 8 Any applicable numeric value Sample switching/selection Manual * Capacity of Sample holder/Sample Carousel 1 * Mximum Path Length of sample 93 Any applicable numeric value Number of Cuvettes supplied 10 10
25
50
100
300
400
500 Power Supply 230 V ± 10
50 Hz * Spares and Consumables inclusive in the scope of supply false true
false List of Items and Quantity of each item included in the offer - * OPERATING CONDITIONS Minimum Operating Temperature 10 -5
10
0
5
10 Maximum Operating Temperature 35 35
40
45
55
60 Operating Humidity (RH) (%) at 40 degree C 85 80
85
90
95 3/5 WARRANTY Onsite Warranty 2 1
3
4
5 Availability of Spares (at extra cost) 10 2
6
7
8
10 Certification Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement
control
and laboratory use General requirements Yes Yes
No Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement
control and laboratory use Yes Yes
No Availability of Test Reports from Central Govt/NABL approved/ILAC acredited lab to prove conformity to the specification No Yes
No If yes test report to furnished
to the buyer on demand N/A * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Vijay Kumar 135001
O/o Civil Surgeon 1 15
517700
GEM/2018/B/73450
GeM Contract
SPECTROPHOTOMETER
GeM Contract
15 days
Haryana; Yamunanagar
PRODUCT
Awarded to International Scientific & Surgicals
₹3.1 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| iMark Microplate Absorbance Reader (Elisa Plate Reader) | Bio-Rad (168-1130) iMark | - | 1 NOS | ₹3.1 L | 312,700 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| SPECTROPHOTOMETER ( PAC Only ) Average Turn Over of Last 3 Years 12 Lakh (s) Experience with Gov. Required 5 Year (s) SPECTROPHOTOMETER ( 1 ) ( Under PAC ) Make biorad Model bio-rad(168-1130)imark Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values TYPE Type of Spectrophotometer UV - VISIBLE UV - VISIBLE | - | - | - |
| VISIBLE | - | - | - |
| UV - VISIBLE - IR Type of Optical System Split Beam Single Beam | - | - | - |
| Split Beam | - | - | - |
| Double Beam Monochromator Type NA Reflexive Grating | - | - | - |
| Holographic Grating | - | - | - |
| Czerny-turner | - | - | - |
| NA Detector Type Photodiode Photo Multiplier Tube (PMT) | - | - | - |
| Photodiode | - | - | - |
| CMOS | - | - | - |
| Diode array Spectral Bandwidth Type Fixed Bandwidth Fixed Bandwidth | - | - | - |
| Variable Bandwidth LIGHT SOURCE Light Source Tungsten Halogen Lamp Halogen Lamp | - | - | - |
| Deuterium Lamp | - | - | - |
| LED | - | - | - |
| Tungsten Halogen 1/5 Lamp | - | - | - |
| Xenon Flash Diffraction Grating (lines/mm) 600 600 | - | - | - |
| 800 | - | - | - |
| 1000 | - | - | - |
| 1200 | - | - | - |
| 1400 | - | - | - |
| 1600 | - | - | - |
| 1800 Switching of Light Source Automatic Automatic | - | - | - |
| Mannual Wavelength Setting And Scanning Automatic Automatic | - | - | - |
| Mannual OPTICAL PERFORMANCE Source Wavelength - Minimum 340 175 | - | - | - |
| 180 | - | - | - |
| 185 | - | - | - |
| 190 | - | - | - |
| 195 | - | - | - |
| 200 | - | - | - |
| 320 | - | - | - |
| 340 Source Wavelength - Maximum 760 * (or higher) Resolution 2 0.002 | - | - | - |
| 0.3 | - | - | - |
| 0.5 | - | - | - |
| 1 | - | - | - |
| 1.25 | - | - | - |
| 1.5 | - | - | - |
| 1.7 | - | - | - |
| 2 Wavelength Accuracy (+/-) 0.8 0.1 | - | - | - |
| 0.8 | - | - | - |
| 2 | - | - | - |
| 2.5 Bandwidth (nm) 0 to 5.0 0.1 | - | - | - |
| 0.2 | - | - | - |
| 1.8 | - | - | - |
| 2.0 | - | - | - |
| 4.0 | - | - | - |
| 5.0 | - | - | - |
| 0 to 5.0 If variable band width | - | - | - |
| Specify the incremental step value(mm) NA * Scanning Speed (nm/min) 1000 * Focal length (mm) 50 to 99 0 to 49 | - | - | - |
| 50 to 99 | - | - | - |
| 100 to 149 | - | - | - |
| 150 to 199 | - | - | - |
| 200 to 249 | - | - | - |
| 250 to 299 | - | - | - |
| 300 and above Photometric measurement modes Absorbance Transmittance | - | - | - |
| Absorbance | - | - | - |
| Concentration (Wavelength | - | - | - |
| time) | - | - | - |
| Reflectance | - | - | - |
| Energy | - | - | - |
| Polarisation Photometric Absorbance (Max) (Abs) (+/-) 0.27 0.2-8 Photometric Absorbance Accuracy (Max) (+/-) 0.35 0.001-0.5 Photometric Transmittance (Max) (+/-) 90 Any applicable numeric value Photometric Transmittance Accuracy (Max) (+/-) 0.35 Any applicable numeric value Photometric Reflectance (Max) (+/-) 86 Any applicable numeric value Photometric 0.35 * 2/5 Reflectance Accuracy (Max) (+/-) Stray Light Correction Automatic * Baseline Correction Automatic * GENERIC Display In-built display In-built display | - | - | - |
| Through PC Display type LCD with Backlight LCD with Backlight | - | - | - |
| LCD touchscreen | - | - | - |
| TFT | - | - | - |
| NA Display Size 2.5 Any applicable numeric value Test result printing Through inbuilt Printer Through inbuilt Printer | - | - | - |
| Through external printer If inbuilt printer | - | - | - |
| Type of printer Thermal printer Thermal printer | - | - | - |
| Dot matrix | - | - | - |
| Laser b/w | - | - | - |
| Inkjet b/w | - | - | - |
| Color laser | - | - | - |
| Color inkjet | - | - | - |
| N/A Suitable software for connecting PC & Printer Yes * Connectivity USB | - | - | - |
| RS 232 * Internal storage(GB) 8 Any applicable numeric value Sample switching/selection Manual * Capacity of Sample holder/Sample Carousel 1 * Mximum Path Length of sample 93 Any applicable numeric value Number of Cuvettes supplied 10 10 | - | - | - |
| 25 | - | - | - |
| 50 | - | - | - |
| 100 | - | - | - |
| 300 | - | - | - |
| 400 | - | - | - |
| 500 Power Supply 230 V ± 10 | - | - | - |
| 50 Hz * Spares and Consumables inclusive in the scope of supply false true | - | - | - |
| false List of Items and Quantity of each item included in the offer - * OPERATING CONDITIONS Minimum Operating Temperature 10 -5 | - | - | - |
| 10 | - | - | - |
| 0 | - | - | - |
| 5 | - | - | - |
| 10 Maximum Operating Temperature 35 35 | - | - | - |
| 40 | - | - | - |
| 45 | - | - | - |
| 55 | - | - | - |
| 60 Operating Humidity (RH) (%) at 40 degree C 85 80 | - | - | - |
| 85 | - | - | - |
| 90 | - | - | - |
| 95 3/5 WARRANTY Onsite Warranty 2 1 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 Availability of Spares (at extra cost) 10 2 | - | - | - |
| 6 | - | - | - |
| 7 | - | - | - |
| 8 | - | - | - |
| 10 Certification Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement | - | - | - |
| control | - | - | - |
| and laboratory use General requirements Yes Yes | - | - | - |
| No Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement | - | - | - |
| control and laboratory use Yes Yes | - | - | - |
| No Availability of Test Reports from Central Govt/NABL approved/ILAC acredited lab to prove conformity to the specification No Yes | - | - | - |
| No If yes test report to furnished | - | - | - |
| to the buyer on demand N/A * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Vijay Kumar 135001 | - | - | - |
| O/o Civil Surgeon 1 15 | - | - | - |
Exempted
30 Aug 2018
25 Aug 2018
contract_GEMC-511687735811799.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_517700.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .