Executive Engineer, panchayat, R & B Division, Surat.
Proposed Sub Centre At Godsamba Village Ta.Mandvi Di.Surat
293230
33 OF 2025-26
Open
Civil Works - Others
Works
Surat
5 documents required · 5 mandatory
₹1,500
Executive Engineer, panchayat R & B Division, surat
₹40,500
2 Apr 2026
2 Apr 2026
2 Apr 2026
23 Apr 2026
2 Apr 2026
PROPOSED SUB CENTER AT GODSAMBA VILLAGE,TA. MANDVI, DIST.SURAT
BILL OF QUANTITIES
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
1 Excavation for foundation upto 1.5 m depth including sorting out and stacking of 171.00 CMT. 122.93
useful materials and disposing off the excavated stuff upto 50 Meter lead. (A) Loose
or soft soil ( I ) 0 To 1.5 mt. Depth
2 Excavation for foundation upto 1.5 m to 3.0 m depth including sorting out and 144.50 CMT. 136.47
stacking of useful materials and disposing off the excavated stuff upto 50 Meter
lead. (A) Loose or soft soil ( II ) 1.5 To 3.0 MT Depth
3 Filling available excavated earth (Including rock in trenches plinth, sides of foundations 257.00 CMT. 136.91
etc. in layers not exceeding 20 cm. in depth consolidating each deposited layer by
ramming and watering)
4 Providing & filling in plinth with murrum or yellow soil or selected soil in layers of 20 20.50 CMT. 301.77
cm. Thickness. Incl. watering, ramming & consolidation etc. complete.
5 Filling in plinth with sand under floors including watering ramming, consolidating 10.50 CMT. 481.80
and dressing complete (A) Foundation and plinth
6 Providing and filling rubbles including hand packing and filling interstices with quarry 28.00 CMT. 1094.11
spalls behind abutments and between returns as directed.
7 Providing and laying cement concrete 1:2:4 (1-Cement : 2- coarse sand : 4- hand 27.50 CMT. 3923.85
Machine crushed stone aggregates 40 mmnominal size) and curing complete including
cost of formwork in (A) PCC
8 Providing and laying controlled cement concrete M.250 and curing complete inculding 42.00 CMT. 4494.50
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in foundation, footings base of column and mass concrete. (A) Footing
9 Providing and laying controlled cement concrete M.250 and curing complete inculding 5.00 CMT. 8226.45
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in All Types of Column D) Column, Pillers, posts and struts , upto Plinth
10 Providing and laying controlled cement concrete M.200 and curing complete inculding 6.00 CMT. 8191.10
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in All Types of Column D) Column, Pillers, posts and struts, upto Ground Floor
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
11 Providing and laying controlled cement concrete M.200 and curing complete inculding 6.00 CMT. 8232.05
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in All Types of Column D) Column, Pillers, posts and struts, upto First Floor
12 Providing and laying controlled cement concrete M.200 and curing complete inculding 4.00 CMT. 8308.36
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in All Types of Column D) Column, Pillers, posts and struts, upto Terrace Floor
13 Providing and laying controlled cement concrete M.250 and curing complete inculding 8.00 CMT. 6440.77
the cost of formwork but Excluding the cost of the cost of reinforcement for reinforced
concrete work in Beams. (E) Beam, upto Plinth
14 Providing and laying controlled cement concrete M.200 and curing complete inculding 6.50 CMT. 6406.43
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in All Types of Beams,(E) Beam, Ground Floor
15 Providing and laying controlled cement concrete M.200 and curing complete inculding 6.50 CMT. 6447.38
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in All Types of Beams,(E) Beam, First Floor
16 Providing and laying controlled cement concrete M.200 and curing complete inculding 2.50 CMT. 6488.34
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in All Types of Beams,(E) Beam, Terrace Floor
17 Providing and laying controlled cement concrete M.200 and curing complete inculding 8.50 CMT. 6351.89
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in All Types of Slab,All Thickness (C) Slab upto Plinth and Ground Floor
18 Providing and laying controlled cement concrete M.200 and curing complete inculding 7.50 CMT. 6392.84
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in All Types of Slab,All Thickness (C) Slab for First Floor
19 Providing and laying controlled cement concrete M.200 and curing complete inculding 1.50 CMT. 6433.80
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in All Types of Slab,All Thickness (C) Slab for Terrace Floor
20 Providing and laying controlled cement concrete M.200 and curing complete inculding 0.50 CMT. 6758.92
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in All Thickness in Walls PARDI Ground Floor
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
21 Providing and laying controlled cement concrete M.200 and curing complete inculding 2.00 CMT. 5951.93
the cost of formwork and Excluding reinforcement for reinforced concrete work in All
Types of Stair case upto Ground Floor
22 Providing and laying controlled cement concrete M.200 and curing complete inculding 2.00 CMT. 5992.88
the cost of formwork and Excluding reinforcement for reinforced concrete work in All
Types of Stair case upto First Floor
23 Providing and laying controlled cement concrete M.200 and curing complete inculding 1.50 CMT. 5949.91
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in Lintel upto Ground Floor
24 Providing and laying controlled cement concrete M.200 and curing complete inculding 1.50 CMT. 5990.86
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in Lintel upto First Floor
25 Providing and laying controlled cement concrete M.200 and curing complete inculding 0.50 CMT. 6031.82
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in Lintel upto terrace Floor
26 Providing and laying controlled cement concrete M.200 and curing complete inculding 2.00 CMT. 5738.82
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in Chajja. Upto Ground Floor
27 Providing and laying controlled cement concrete M.200 and curing complete inculding 2.00 CMT. 5779.77
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in Chajja. Upto First Floor
28 Providing and laying controlled cement concrete M.200 and curing complete inculding 0.50 CMT. 5820.73
the cost of formwork but Excluding the cost of reinforcement for reinforced concrete
work in Chajja. Upto Terrace Floor
29 Providing and fixing TMT bars Fe-500D steel reinforcement for R.C.C. work including 14966.00 Kg . 77.80
binding, bending and placing in position complete upto floor two level ,Ground Floor,
First Floor , Second Floor, Third Floor, Terrace Floor (all floor).
30 Applying general insecticide pest control treatment to floors, cupboards etc including 68.00 SMT. 91.62
labour material etc. complete. Using Heptachloride 20 EC. As Per 6113_pests
Consentration Weight 0.50 percent is recommended one litre chemical emulsion dillute
31 Brick work using common brunt clay building bricks having crushing strength not less 13.00 CMT. 4214.32
than 35 kg/sqcm. in foundation and plinth in cement mortar 1:6 (1 cement :6 fine sand)
etc.comp. (B) Conventional Ground floor upto Plinth
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
32 Brick work using common brunt clay building bricks having crushing strength not less 23.00 CMT. 4503.04
than 35 kg/sqcm. in superstructure above plinth level upto floor two level in cement
mortar 1:6 (1 cement :6 fine sand) etc.comp. (B) Conventional Ground Floor
33 Brick work using common brunt clay building bricks having crushing strength not less 22.00 CMT. 4545.16
than 35 kg/sqcm. in superstructure above plinth level upto floor two level in cement
mortar 1:6 (1 cement :6 fine sand) etc.comp. (B) Conventional First Floor
34 Brick work using common brunt clay building bricks having crushing strength not less 13.50 CMT. 4587.27
than 35 kg/sqcm. in superstructure above plinth level upto floor two level in cement
mortar 1:6 (1 cement :6 fine sand) etc.comp. (B) Conventional Terrace Floor
35 Half brick masonry in common brunt clay building bricks having crushing strength not 19.00 SMT. 685.65
less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in (B)
Conventional Ground Floor
36 Half brick masonry in common brunt clay building bricks having crushing strength not 29.50 SMT. 741.48
less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in (B)
Conventional First Floor
37 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or 186.00 SMT. 161.19
Full/half brick walls for interior plastering upto floor two level and finished even and
smooth in (ii) Cement mortar 1:4 (1-cement :4-sand) Ground Floor
38 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or 195.50 SMT. 185.75
Full/half brick walls for interior plastering upto floor two level and finished even and
smooth in (ii) Cement mortar 1:4 (1-cement :4-sand) First Floor
39 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or 60.50 SMT. 210.32
Full/half brick walls for interior plastering upto floor two level and finished even and
smooth in (ii) Cement mortar 1:4 (1-cement :4-sand) Terrace Floor
40 Providing & laying10 mm. thick cement plaster in single coat on fair side of ceilings 54.00 SMT. 148.31
for interior plastering upto floor two level and finishing with smooth mala plaster.(i)
Cement mortar 1:4 (1 cement : 4 sand) Ground Floor
41 Providing & laying10 mm. thick cement plaster in single coat on fair side of ceilings 54.00 SMT. 171.24
for interior plastering upto floor two level and finishing with smooth mala plaster.(i)
Cement mortar 1:4 (1 cement : 4 sand) First Floor
42 Providing & laying10 mm. thick cement plaster in single coat on fair side of ceilings 9.00 SMT. 194.17
for interior plastering upto floor two level and finishing with smooth mala plaster.(i)
Cement mortar 1:4 (1 cement : 4 sand) Terrace Floor
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
43 20mm thick sand faced cement plaster on walls upto height 10 metres above ground 241.00 SMT. 315.68
level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm
thick finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete. Upto Ground Floor
44 Providing throating or plaster drip and moulding to R.C.C. Chhajja. 60.00 RMT. 44.27
45 Providing and laying polished Granite Slab 18mm thick in Flooring laid 20mm thick 18.00 SMT. 2377.54
Cement Mortar 1:4 (1-Cement : 4-Coarse Sand) and jointed with Grey Cement Slurry
including full molded round front edges , rubbing and polishing etc. complete.
46 Providing and laying polished Granite Slab 18mm thick in Risers of steps Dedo, 56.50 SMT. 2408.85
window sill, jembs and pillars laid 10 mm thick Cement Mortar 1:4 (1-Cement : 4-
Coarse Sand) and jointed with Grey Cement Slurry including full molded round edges
47 Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24'' in flooring treads of 94.50 SMT. 1120.36
steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-cement : 3-coarse
sand ) finishing with flush pointing in white cement.Soluble Salt PVT. Tiles in All
48 Providing and laying Vitrified tiles 8 mm thick , 24'' x 24'' in skrting risers of steps and 76.50 SMT. 1195.02
dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and jointed with
white cement slurry Soluble Salt PVT. Tiles in All Rooms.
49 Providing and fixing 37 mm thick flush door both sides laminated andshutter fabricated 16.50 SMT. 3767.30
from 35 mm thick solid core malemine faced three layered pre laminated flat pressed
wood based exterior grade bonded BWP/BWR synthetic resin having stamped IS
50 Providing and fixing FRP frame size 125x65 mm and 35mm thick FRP shutter having 8.50 SMT. 2615.04
extra reinforcement on sides & edges in polish finish. The core of the shutter & frame is
to be filed up with injected polyurethene foam done in situ alongwith embedded wooden
pieces for stiffening & also taking hinges & fintures. The whole FRP frame & shutter is
to be water proof weather proof, termite proof & resistance to mild acid/alkali. Rates are
to be inclusive of S.S hinges with necessary screws & alluminium S.S fixtures &
fastenings & fastener sleeve.
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
51 Providing and fixing window having extruded aluminum Colour anodized section frame 14.04 SMT. 1583.95
main outer size 95mm x 24mm x 1.17mm @ wt.of 0.738 Kg/mt , horizontal Three track
member size 92mm x 31.75mm x 1.30mm,@ Wt.1.07 Kg/mt , vertical member of size
92mm x 31.75mm x 1.50mm @ Wt. 1.06 Kg/mt with two sliding shutters of horizontal
member size 40 mmx18mm x1.29mm @ wt.of 0.456 Kg/mt, vertical member of size
40mm x 18mm x 1.29 mm @ wt.of 0.456Kg/mt/ with one mosquito net with 5 mm thick
transparent bronze colour tinted float glass with powder coated aluminum fittings and
fixtures and transparent silicon sealant glass fixing to frame as per details etc
52 Providing and fixing standared extruded of alluminium section of size 63mm x 3.00 SMT. 1175.55
38.10mm x 1.2mm (Wt. 0.643 Kg/mt) with colour anodized alluminium frame for
ventilation with 5 mm thick frosted glass as details etc complete for Ventilation
53 Providing and fixing M.S. grill of required pattern of windows etc. with M.S.. flats at 340.00 Kg. 117.16
required spacing and frame alround square or round headed bolts and nuts or by
screws.including applying a priming coat of red lead paint and two coats of oil painting
54 Applying two coats of Birla (white cement based) or (acrylic lapy- putty) or equivalent 442.00 SMT. 130.64
& two coats of primer of approved brand and manufacture on new wall surface to give
an even shade including thoroughly brushing the surface free from mortar dropping and
other foreign matter and sand papered smooth. with Wall painting (three coats) with
plastic emulsion paint of approved brand and manufacture on undecorated wall surface
to give an even shade including throughly brushing the surface free from mortar
droppings and other foreign matter and sand papered smooth.
55 Applying two coats of Birla (white cement based) or (acrylic lapy- putty) or equivalent 117.00 SMT. 173.19
& two coats of primer of approved brand and manufacture on new Ceiling surface to
give an even shade including thoroughly brushing the surface free from mortar dropping
and other foreign matter and sand papered smooth. Ceiling painting (three coats) with
plastic emulsion paint of approved brand and manufacture on undecorated Ceiling
surface to give an even shade including throughly brushing the surface free from mortar
droppings and other foreign matter and sand papered smooth.
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
56 Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to 240.95 SMT. 166.65
give an required shape even shade after thoroughly brushing the surface to remove all
dirt, and remains of loose powdered materials.etc complete. Priming: Apply a liberal
coat of exterior acrylic primer and allow it to dry for 4-5 hours. Application of putty is
not recommended. Minimum 4-6 hours duration is required between each coat of
weather shield max paint
57 Applying priming coat over new steel and other metel surface after and including 6.50 SMT. 128.62
preparing the surface by throughly cleaning, oil,grease, dirt and other foreign matter and
scoured with brushes fine steel wood, scrapers and sand paper with ready mixed priming
paint brushing red lead. and Painting two coats (excluding priming coat) on new steel
and other metal surface with enamel paint, brushing, interior to give an even shade
including cleaning the surface an even shade including cleanicn the surface of all dirt,
dust and other foreign matter.
58 Steel work welded in built up sections, framed work including cutting, hoisting, fixing 0.50 Quintal 9108.48
in position and applying a priming coat of red lead paint :-
(A) In beams and joints channels angles, column, tees, flats with connecting plates or
angle cleats as in
59 Providing and laying integral cement based water proofing treatment including 54.00 SMT. 880.72
preparation of surface as required for treatment of roofs, balconies, terraces etc.
consisting of following operations.
(a) Applying and grouting a slurry coat of neat cement u,brick bats is finally covered by
jointless cement plaster 20mm th. in C.M. 1:4 added with special water proofing
compound confirming to IS:2645 & top smooth finished with trowel with false
chequered marking of 300 mm.size.The treatment is carried along
60 Providing and laying broken chine mosaic flooring for terrace using 12 mm to 54.00 SMT. 779.69
20 mm broken pieces of glazed tiles to be laid over cement mortar 1:3 to plain or slope
and to be tempered to bring mortar creme out upto surface using
61 Providing and fixing Stainless Steel railing having 50 mm dia hollow stainless steel pipe 37.50 RMT. 3101.71
as hand rail and 32 mm dia hollow stainless steel pipe with combination of 10 cm long
16mm dia pipe as per virtical supports 20 mm dia hollow stainless steel pipes H
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
62 Providing and fixing Teak Wood Frame 50 x 75 x 35 mm with 19mm thick ply shuttur 5.00 SMT. 8083.03
with both sides laminated and shutter fabricated from 19 mm thick including three coats
of lacquer polishing to exposed wooden surfaces and Stainless steel decorative ty
63 Providing and constructing sandwitch type Granite stone top & bottom Kota Stone 3.53 RMT. 3589.54
platform 0.6 mt. wide & 0.75 mt. height, including front granite stone patti of 10 cm
wide, vertical partitions of Kota stone with cement Mortar(1:1) as required comp as per
64 Providing and fixing kitchen platform trolley having three drawers of SS (IS 304) of 3.53 SMT. 19250.60
required size like thali, katleri, perforated, partition, cupsosar type in kitchen platform
having drawer front side and backside by using 19mm thick all proof plywood of ( IS
710 ) quality all side laminated etc. as directed. The size of SS (IS 304) basket of size 4"
to 18" for thali, dish, katleri, perforated, partition, cupsosar type as directed including
necessary S.S. fittings, handles, nobs, telescopic channels, etc. as directed
65 Providing and fixing in position 300mm high,150mm wide English/Gujarati Letters 2.00 SMT. 707.00
made from 1.0mm thick stainless steel sheet as directed by engineer in charge. With all
tools & plants etc. comp.
66 Providing and fixing wash down water closet (European type, W.C. Pan) with integral P 4.00 No 4327.52
or S trap including jointing the trap with soil pipe in Cement Mortar 1:1 (1-Cement : 1-
fine sand) (Seal and cover to be measured and paid for separately)(A) vitreous China
Pattern :(i) in white colour, Providing and fixing 12.5 Litres low level flushing cistern
with a pair, of C.I. or Mild brackets, complete with fittings such as lead valve less
syphon, 15mm nom.nal size brass ball valve with polythene float, C.P brass handle
unions and couplings for connections, with inlet, outlet and overflow pipes, 40mm
dia.porcelain enamelled flush bend including cutting holes in walls and making good the
same connecting the flush bend with cistern and closet (overflow pipe to be measured
and paid for separately)(A) Vitreous China (I) In white colour, Providing and fixing
plastic seat and cover for wash down water closer with C.P. brass hinges and rubber
buffers. (B) Black plastic seal and cover, With Jet spray heavy duty with S.S. Braided
hose 60 cm long.
67 Providing and fixing washbasin with single hole for pillar tap with C.I. or M.S. brackets 4.00 No 2461.70
painted white including sutting holes and making good the Providing and fixing C.P.
brass waste for washbasin or sink. (A) 32mmdia.,Providing and fixing pillar tap,
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
68 Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm diameter with 6.00 No 599.63
jali of the following nominal diameter of self cleansing design with C.I scread down or
hinged grating including the cost of cutting and making good the walls.
69 Providing and fixing screw down bib taps of following size.(A) Brass screw down bib 8.00 No 186.82
tap polished bright. (i) 15mm dia.
70 Providing & fixing of overhead shower 80 mm (3”) dia with 3 flow with Overhead 3.00 No 1151.87
Shower arm 200 mm with wall flange complete (i) 15mm dia.,Providing and fixing brass
screw down stop tap.(A) 15mm dia. (900 + 240.47 = 1140.47)
71 Providing and fixing Kitchen sink with C.I. or M.S. brackets, painted white including 1.00 No 3204.92
cutting holes in walls and making good the same (C) S.S. & Sink.(i) 600mm x 450mm
x 150mm size with Providing and fixing C.P. brass waste for washbasin or sink. (A)
72 Providing and fixing 600mm x 450mm bevelled edge mirrror of superior glass mounted 4.00 No 859.40
on 6mm thick A.C. sheet or plywood sheet and fixing to wooden pluge with C.P. brass
screws and washers.
73 Providing and fixing C.P. brass towel rail comlete with C.P. brass brackets fixed to 3.00 No 616.42
wooden plugs with C.P. brass scews.(B) 600mm x 20mm size.
74 Providing and fixing 600mm x 120mm glass shelf with C.P.brass bracket and guard rail 3.00 No 544.51
complete mixed to wooden plug with C.P. brass screws
75 Providing and fixing Gun metal check or non-return fullway wheel valve. 25mm. dia. 2.00 No 420.63
76 Providing and fixing Gun metal check or non-return fullway wheel valve. 40mm. dia. 2.00 No 663.42
77 Providing and fixing chromium plated brass half turn flush cock of approved quality 4.00 No 263.77
including fixing in pipe line etc. complete.(ii) 25mm dia.
78 Providing and fixing ball cock of approved. quality as directed.(A) Copper Metal (A) 1.00 No 132.88
79 Providing laying and jointing in true line and level 15mm dia. U.P.V.C. Pipe ( SCH- 40) 45.00 RMT. 72.64
for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed
on the wall with the help of clamp at every two metre C/C or shall be concealed as
directed including necessary fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all materials.
80 Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- 40) 46.00 RMT. 91.83
for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed
on the wall with the help of clamp at every two metre C/C or shall be concealed as
directed including necessary fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all materials.
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
81 Providing laying and jointing in true line and level 50mm dia. U.P.V.C. Pipe ( SCH- 40) 10.00 RMT. 195.66
for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed
on the wall with the help of clamp at every two metre C/C or shall be concealed as
directed including necessary fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all materials.
82 Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) 57.00 RMT. 878.56
conforming to IS 13592-1992 with one end plain and other end socketed with rubber
ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system
pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed
on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm
heigh at every 2000 mm center to center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc. including testing of pipes and
joints and jointed with adhesive solvent cement including cost of all materials.
83 Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water 2.00 No 1246.91
tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight.(i)
Square mouth traps.(B) 150mm x 100mm size P or R type
84 Constructing Brick masonry road gully chamber 500mm x 450mm x 600mm including 3.00 No. 2017.19
500mm x 450mm C.I. horizontal grating wih frame complete.
85 Constructing brick masonry chamber for underground C.I. Inspection chamber and 3.00 No 2932.92
bends with bricks having crushing strength not less than 35Kg/Cm2 in C.M. 1:5 C.I.
cover with frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover
with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. )
(R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate
20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar
1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc.
complete.(i) Inside dimensions 455mmx 610mm and 450mm deep for single pipe line.
86 Providing laying (to level or slopes) and jointing reinforced concrete Light duty non- 12.00 RMT. 257.18
pressure pipes I.S. class NP2 of the following internal diameter with collars and butt
ends prepared for collar joints including testing of joints complete. (B) 150 mm d
87 Providing laying (to level or slopes) and jointing reinforced concrete Light duty non- 10.00 RMT. 359.84
pressure pipes I.S. class NP2 of the following internal diameter with collars and butt
ends prepared for collar joints including testing of joints complete.(C) 250 mm di
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
88 Providing laying (to level or slopes) and jointing reinforced concrete Light duty non- 10.00 RMT. 678.02
pressure pipes I.S. class NP2 of the following internal diameter with collars and butt
ends prepared for collar joints including testing of joints complete.(D) 300 mm di
89 Providing & fixing G.I. Rain water spout of 50 mm.dia & 30 cm length etc. 2.00 No. 101.90
90 Providing and fixing in position cowel went to pipes.(C) 100mm dia 2.00 No. 505.17
91 Providing erecting and fixing double coated PVC. (ISI) water tank of required 1000.00 Lit 3.94
capacity each with all necessary fittings and connection etc. complete on terrace.
92 Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) 37.00 Pt. 485.81
both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up
to 10 mtr length , in below type of pipe erected with 6A Modular type switch / bell push
& accessories and earth continuity of following type, erected on PVC /
Metallic/Wooden box, single mounting base frame covered with textured/ metallic/
white front plate modules erected on / in wall / ceiling as per pipe erected, with
necessary Lamp holder/ ceiling rose / H.D.Connector as directed. (f) with medium class
Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat. III
93 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of 7.00 Pt. 674.68
.ISI marked 1.1 KV Grade FRLS PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected with 6A Modular type switch and hum free EME
step type electronic fan regulator mounted and accessories with earth continuity of
following type erected on PVC / Metallic/ Wooden box, single mounting base frame
covered with textured/metallic/white front plate modules erected on / in wall / ceiling as
per pipe erected. with necessary ceiling rose / H.D.Connector as directed. (f) with
medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete Cat. III
94 Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket 8.00 Pt. 257.55
erected on PVC/ Metallic/ Wooden box, single mounting base frame covered with
textured / metallic/ white front plate modules erected on/ in wall/ ceiling with following
type accessories Cat. III
95 Providing following type of Modular Type Accessories mounted with PVC / 10.00 Nos 151.50
metallic/Wooden box, single mounting base frame covered with textured /
metallic/white front plate , modules erected with necessary connections as per site
situation directed by Engineer In charge. (1)One No. SP 6 Amp. Cat.III
96 (2) One No 5 pin plug Cat.III 10.00 Nos 151.50
97 (3) Two Pin/RJ-11 Telephone Socket [A] For One Gang Cat.III 3.00 Nos 160.59
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
98 (8) Computer RJ-45 socket Cat.III 8.00 Nos 160.59
99 (9) 16 Amp. SP one way switch Cat.III 10.00 Nos 180.79
100 (10) 6/16Amp. Universal socket Cat.III 10.00 Nos 190.89
101 Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size 165.00 Mtr. 24.24
complete to be erected on/in wall or ceiling erected with necessary PVC fittings &
Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in
approved manner as directed (a)20 mm
102 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked 360.00 Mtr. 82.82
stranded Copper conductor wire in following type of pipe to be erected concealed in
/flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of following size (A) With medium
class Rigid PVC pipe and accessories (b) 2 wire 2.5 sq. mm
103 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked 270.00 Mtr. 112.11
stranded Copper conductor wire in following type of pipe to be erected in / on wall /
ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size (A) with medium class Rigid PVC pipe and
accessories (a) 2 wire 4 sq. mm
106 providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, 12.00 Mtr. 56.56
annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring) with required size of copper lugs,
nuts and bolts if required. (e) One wire 6.00 sq. mm
107 (f) One wire 10.00 sq. mm 21.00 Mtr. 91.91
108 Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv grade ISI 12.00 Mtr. 46.46
marked copper wires of following size to be erected as directed.(e) 1.50 Sq.mm 3 core
round PVC sheathed
109 Supplying & erecting approved make Telephone Cable electrolytic copper conductor PE 45.00 Mtr. 20.20
insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with
FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT
erected in existing pipe. of following size of conductors & nos.of pairs. With necessary
connections. [A] Conductor Size 0.5 mm (a) Unarmoured (2) Two Pairs
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
110 Supplying & erecting approved make LAN cable of following size in existing pipe as 120.00 Mtr. 47.47
per direction [C] CAT -
111 Providing & erecting Switch board for Computer or electric apparatus consisting of 8.00 Nos. 1133.22
following modular type accessories mounted with PVC/ Metallic concealed/ open box
with single mounting base frame covered with textured/ metallic/ white front
plate,modules erected with necessary connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug
For Modular Type Accessories
112 Decorative call bell Ting-tong box type 250 volts complete erected 2.00 Nos. 71.71
113 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt 15.00 Nos. 373.70
assembled on single MCPCB, with housing used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/ CRCA/ aluminium die cast powder coated and high
U.V. & corrosion resistance with diffuser with company mark/name 160V to 270V,
Power Factor more than 0.95, THD < 15%, CCT 3000 K to 6500K, Luminaire
efficacy> 85 lumens/ watt, LED driver efficiency > 85 % (fitting required LM-79 & LM-
80 Certificates) (NOTE: Below description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any wattage capacity between the ranges
shown.) (A) Tube Light with integral driver (iv) 22-24 Watts, Surge - 2KV,IP-20,
conventional 4 feet Cat.III
114 Supplying and erecting led lamps with following wattage capacity of 220 to 240 voltage, 9.00 Nos. 112.11
minimum 15000 burning hours life, 500 V in built-surge protection,Polycarbonate
diffuser, mounting suitable for E14 / E27 / B22 lamp holders, pf >= 0.5 (A) LED Lamps
integral type, with PC diffuser suitable LAMP holder (ii) 5 to 8 watts
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
115 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt 7.00 Nos. 758.51
assembled on single MCPCB, with housing used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/ CRCA/ aluminium pressure die cast powder coated
and high U.V. & corrosion resistance with diffuser housed in aluminium casted body
with company mark/name 160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt, LED driver efficiency >
85 % ( fitting required LM-79 & LM-80 Certificates) (NOTE: Below description have
shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A) Square/ Circular shaped
Surface/Recessed Mount Downlight with provision for spring loaded mounting clips
complete.IP20 (iv) 22-24 watts, Surge-2 KV Cat-III
116 Supplying and erecting LED street light / Flood light fittings with High power White 4.00 Nos. 3345.12
LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than
130 lm/w and corrosion free High pressure die cast aluminum housing with smooth
finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate
optics/ lenses, with toughened glass with company mark/name engraved or embossed
160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver
efficiency > 85 %. (fittings required LM-79 & LM-80 certificates) (NOTE: Below
description have shown ranges of Wattage capacity of LED fittings.The Engineer
incharge may select any wattage capacity between the ranges shown.) (A) Street Light
(IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with
over-voltage protection. (i) above 36 to 48 watts Cat.III
117 Providing and erecting Approved make Four pole moulded case circuit breaker having 1.00 Nos. 6173.12
breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to
100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s.
with all internal connections, spreader tinned copper & complete erected in existing
G.M.S. housing. ICS=100% of ICU only Cat III
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
118 Supplying and erecting triple pole & neutral 440V /500V panel mounting Copper 0.40 Rmt 1961.42
Busbars with four equal Nos. of electrolyte bus having current density not more than
Amp. / sq.mm (Rated current /cross section area) duly wrapped with colour insulating
tape for phase sequence of following current carrying capacity, erected with necessary
bus bar supports /insulators, main cable socket to each bar, erected in existing cubical
panel with necessary connections. (A) Suitable for 100 Amp. Capacity
119 Providing and erecting Miniature circuit breaker single pole 0.5A to 2A system and 4.00 Nos. 270.68
having breaking capacity 10 KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark Cat.III
120 Providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to 20.00 Nos. 112.11
operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with ISI Mark Cat.III
121 Providing & erecting 240 V MCB double pole switch for motor & inductive load (C 4.00 Nos. 330.27
Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having
following capacity (B) 40 Amp. Cat.III
122 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) 3.00 Nos. 668.62
having 10KA breaking capacity & confirms to IS :8828 in existing box having following
capacity (b)40 Amp. Cat.III
123 (c)63 Amp. Cat.III 4.00 Nos. 737.30
124 Providing and erecting Sheet Steel powder coated MCB distribution board - flush / 1.00 Nos. 1492.78
surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The
DBs should be used of same company of MCB to be used) suitable for (A) single phase
incoming and horizontal single phase outgoing (b) sheet steel double door (IP-43) (iv)12
125 (B) three phase incoming and single phase horizontal type outgoing Per phase isolation 1.00 Nos. 2339.16
type (PPI) (b) sheet steel double door (i)4 way
126 Providing and erecting Approved make RCCBs conforming to IS: 12640 and having 4.00 Nos. 2235.13
sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for
operation on single phase 240 V,50Hz. having characteristic of quick action & tripping
with all advance feature & do not incorporate any electronic component. for following
Max. rating erected as directed (ii) 40Amps. DP Cat. III
127 Providing and erecting Annealed bare Copper wire 8 to 16 SWG. 2.00 Kg. 794.87
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
128 Providing and erecting Pipe type earthing having 150 cms.long and 2.5 cms. dia. 2.00 Nos. 368.65
galvanised iron pipe with coupling and buch buried in specially prepared earth pit
complete with necessary 8 SWG earth wire.
129 For using salt and charcoal / coke as required for pipe type earthing. 2.00 Nos. 171.70
130 Supplying & erecting earth pit of minimum bore dia.150mm size approved make 1.00 Nos. 4591.46
Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of
corrosion free hot dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200
Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant ohmic value surrounded by highly
conductive compound with high charge dissipation suitable for following type of
applications with chamber and heavy duty cover. (A)(approved make OEM has to
submit test certificate including value of earth resistance of installation duly stamped
and signed by agency and officer Incharge has to ensure the value of earthing resistane
mentioned in test Certificate) & having back filling compound of (B) Inner chemical
(CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017,
Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable to retain moisture for long time
Necessary test report must be submitted by Agency. (a) For Electrical Installation up to
440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
131 Providing & erecting weather proof, dust & vermin proof, floor mounted front operated 1.00 Smt. 10468.65
indoor type cubical panel board necessary IP-42 and above protection as per approval
from engineer incharge made from 14 SWG thick CRC M.S. sheet for outer body &
doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary accesories
supporting angles/ flats channel including cutting, bending, drilling, welding, riveting
with internal partitions & cable alley as per requirements & instruction of engineer-in-
charge with erection of supplied switch gears, BUSBARS, suitable size of inter
connecting PVC copper wire / copper-aluminium strips, rubber grommets, rib, bakelite
control fuses/MCB for measuring instruments, earth bus & earth bolts, foundation
flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking
arrangement and rubber gasket,heavy duty end terminal connection,danger notice
board,necessary ventilation,earthing strip complete. The Panel shall be painted with
epoxy powder coating. (The rates excludes the cost of switchgears, bus bars, inter
connecting mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall
be measured excluding base beams) The panel shall be supplied with following
approved manufacturers with following size. (A) locally fabricated panel board (i) with
132 Providing, erecting, fabricating the M.S. structure as per requirement on site 10.00 Kg. 77.77
incorporating proper size of M.S. angles,square,round, flats, bars, channels, sections
complete with cutting, welding, grinding & finishing duly painted with one coat of red
oxide with erection on site as per direction of engineer in charge with necessary
grouting, cementing, plastering & finishing complete.
133 Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured cable multistrand 30.00 Mtr. 284.82
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (C) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2
134 Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured cable multistrand / Solid 80.00 Mtr. 126.25
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (B) 4 core 6 Sq. mm
135 Making trench in soft soil of suitable width of 90 cm deep for laying cable or locating 50.00 Mtr. 55.55
the fault all over the run and back filling the same and making the surface as normal
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
136 Providing & laying approved make Double walled corrugated pipes (DWC) of 50.00 Mtr. 62.62
polyethylene (conforming to IS 14930 II) with necessary connecting accessories of
same material at required depth in existing trench for laying of cable. below ground /
road surface for enclosing cable (A)50 mm outer dia
137 Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC 8.00 Nos. 38.38
insulated armoured cable complete with out going tails, insulating tape etc for following
size of cables.(B) 2 to 4 core 6 Sq. mm
138 Providing and, fixing heavy duty flange type brass double compression type cable 2.00 Nos. 75.75
gland with rubber ring for PVC insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables.(B) 3 & 1/2 core 35/50 Sq. mm
139 Solder less crimping type Aluminium lugs conforming to IS suitable for cable of 32.00 Nos. 0.00 -
following size evenly crimped with high pressure tool & connected to switchgear
terminals with brass/ cadmium plated nut bolts in an approved manner.(A) 1.5/ 2.5/4/6
141 Providing and erecting Approved make Ceiling fan with double ball bearing ISI mark 7.00 Nos. 1596.81
with condenser A.C. 23OV.50 c/s.1200 mm. sweep complete, canopy erected on
existing hook or clamp with earthing. [Make shall be approved by Engineer in charge]
142 Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod 7.00 Mtr. 108.07
erected duly painted for fan complete with proper insulation without leakage and
143 Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to the RCC bars 7.00 Nos. 108.07
up to 50mm length each side and pierced through a 16 Gauge M.S. box / Heavy Duty
PVC box complete erected concealed in Ceiling with necessary finishing.
144 Supplying & erecting single phase approved make industrial exhaust fan suitable for 4.00 Nos. 2054.34
medium duty ring mounted low noise operation suitable for medium duty having
following dia size and maximum speed in RPM [A] 305 mm dia 900 RPM Cat.II
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
145 Supplying and erecting approved make Octagonal pole made from HR sheet steel. The 4.00 Nos. 6874.06
pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS
2629/2633/4759, suitable suspend local wind speed with integral Junction box consist of
terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for
MCB Mounting, stud type terminal and arrangement for cable termination to be erected
With Suitable foundation (Included) as per details given by manufacturer considering
site requirement. (C) 5 Mtr. Long 70 mm Top X 130 mm bottom dia, 3 mm thickness
with 200mmX200mmX12mm base plate, 4-M16 Bolts and 600mm long with necessary
G.I. J Bolts .Approx Pole weight 46 kg
146 Supplying and erecting Street light pole bracket comprising main B Class GI pipe of 4.2 4.00 Nos. 491.87
cm/require outside dia. complete with suitable B Class G.I. sleeve tubing of approx.
45cms.length and suitable for 76.5mm/80mm/require size of pole top having nuts and
bolts for fixing the brackets and having spread of 0.5 mtr. Length with 110 deg.with
vertical plane and suitable welded stiffener reducer and nipple with check nut complete
painted with one coat.of Red oxide / PU base primer and two coats of Aluminium / PU
paint. paint with following nos of arms.[A] Single Arm bracket 0.5 Mtr
147 Supplying & erecting IP 55 grade following size section pillar fabricated from joint less 1.00 Nos. 3595.60
M.S. Sheet with angle iron legs made from jointless M.S. Angle with cable clamps to be
buried in ground to have appropriate erection to work uniform until erected with cement
concrete foundation and 45 cm high bricks work finishing with plaster etc. hinged
double door internally supported on both side, with internal and outside looking
arrangement with look and keys in duplicate 35 x 35 x 5 mm M.S. Angle of Two Nos.
one is welded and other with nut and bolt for erecting Bakelite sheet. Painting the
Section Pillar inside and out side with three tank powder coated paint. section pillar
roof should be without joint with water leakage proof & tested as per IP 55 test &
followed by IS 2147 of 1962 (B) 75 X 60 X 45 cm section pillar fabricated from
Gauge MS Sheet with angle iron legs 45 cm long made from 35 X 35 X 5 mm thick MS
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
148 Supplying & erecting approved make Digital time switch having lithium cell 6 years 1.00 Nos. 3168.37
operative and operate battery backup 1 channel day clock with 14 memory programme,
suitable to operate on 240V + 5%, 16A with, floating contacts Minimum switching
setup time 1 minimum & LCD display. Also comprised permanent ON/OFF switching.
Programming switches & housed in fire proof thermoplastic enclosure & transparent
cover erected as required with necessary connection erected as directed.
149 Supplying & erecting power contactor ,AC3 duty for time switch complete erected as 1.00 Nos. 2782.55
per direction Cat III (D) 4 pole 440V 40 Amp.
150 Supplying and erecting approved make panel mounting type Digital Voltmeter having 3 1.00 Nos. 1275.63
digits LED display, 0 to 750 AC Volts range erected on existing panel board with all
connection, wiring etc .with manufacturers calibration certificate.
151 Supplying and erecting approved make panel mounting type Digital Ammeter having 3 1.00 Nos. 1558.43
digits LED display, external CT operated, calibrated for 0 to 1000 Amps suitable to
operate on 500 Volt AC, erected on existing panel board with all connection, wiring etc
.with manufacturers calibration certificate.
152 Supplying and erecting Ammeter / Voltmeter selector switch for 3 phase AC Supply 2.00 Nos. 317.14
500 V on existing panel board with necessary connections.
153 Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio 3.00 Nos. 274.72
15 VA burden erected in existing CRCA box duly secured with insulating materials
connected to the meter
154 Supplying and erecting approved make suitable panel indicator LED type lamp, lens 3.00 Nos. 43.43
cover, complete erected with necessary connections.
SCHEDULE B Page
Item No. Description of Item (With brif Specification And Reference to Book of Specifications) Quantity Unit Amount
155 Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity 1.00 Nos. 8671.86
with necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall
complete. [B] For 5.5 / 6.5 KG Capacity
(1) The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge for which no extra payment shall
(2) The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
(3) GST and Income tax TDS will be deducted at a source while making payments of bills
(4) In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017 Cement Consumption/16/C
Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a change as per actual mix design the cost of difference of cement consumption
have been deducted from the rate of original item at the rate of input rate mentioned in all the tender.
SCHEDULE B Page
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
3.Cement Standards -11-05-17 GR 2 Side.pdf
4.Tender Negotiation.pdf
5.Laboratory GR.pdf
6.GST GR.pdf
7.Steel Lap.pdf
11. Other GR.pdf
8.Clause 47 48.pdf
14 Building Booklet civil.pdf
Cement consumption gr.pdf
GST GR 1.pdf
Inspection 1.pdf
Laboratory GR 1.pdf
Steel Lap 1.pdf
5.GR.pdf
4.0 tender booklet.pdf
GR.pdf
01 PLAN and ELEVATION SUB CENTRE Godsamba.pdf
02 ELEVATION Godsamba.pdf
BOQ BOQ Godsamba Sub Centre MandviNEW.pdf
CamScanner 04-09-2025 15.03.58.pdf
DMO_2876_01-May-2025_273.pdf
SBD Sub Centre Godsamba.pdf
SBD સાથે જરૂરી દસ્તાવેજો For VC AND SC.pdf
GRs - SBD with Index_11zon (1).pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .