Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹41.1 L+₹3.4 L (8.90%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹43.7 L+₹6.0 L (15.9%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹45.9 L+₹8.2 L (21.7%)Rejected-Finance 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹52.1 L+₹14.4 L (38.1%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹88,600
Closing Date
3 Nov 2020, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF AMB-44/2020-21 MANNING AND OPERATION OF AC PLANT INSTALLATIONS, REPAIRS / MAINTENANCE OF COOLING APPLIANCES AND POWER FACTOR / VOLTAGE STABILIZERS AND OTHER ALLIED WORKS IN ZONE-B AT AF STATION AMBALA UNDER GE (AF) AMBALA
2020_MES_384556_1
GE AF/AMB-44/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE AF AMBALA
₹88,600
Yes
13 Nov 2020
8 Oct 2020
5 Nov 2020
8 Oct 2020
3 Nov 2020
22 Oct 2020
Amount
PART-I (M&O WORKS)
Manning, operation and comprehensive maintenance of central type AC plant of capacities 3x 24 TR installed at Base ops by providing one skilled refrigeration mechanic each for 03 (three) shifts of 8 hours each, on all days including Sundays & holidays, round the clock for trouble free functioning of the installations complete all as specified hereafter and as directed by the Engineer-in-Charge
Skilled refrigeration mechanic (with minimum 2 years experience) (minimum wages as notified)
Contribution towards Employees Provident Fund (EPF) as per existing rules
Contribution towards Employees State Insurance Corporation (ESIC) as per existing rules
Contribution towards Bonus as per existing rules
Contractor's Overheads & Profit on total of serial item Nos. 2.01 to 2.04
Labour Welfare Cess (LWC) as per existing rules on total of serial item Nos. 2.01 to 2.05
Manning, operation and comprehensive maintenance of central type AC plant of capacities 3x24 TR at IInd Line by providing one skilled refrigeration mechanic each for 02 (two) shifts of 8 hours each, on all days including Sundays & holidays for trouble free functioning of the installations complete all as specified hereafter and as directed by the Engineer-in-Charge
Skilled refrigeration mechanic (with minimum 2 years experience) (minimum wages as notified)
Contribution towards Employees Provident Fund (EPF) as per existing rules
Contribution towards Employees State Insurance Corporation (ESIC) as per existing rules
Contribution towards Bonus as per existing rules
Contractor's Over Head & Profit on total of serial item Nos. 3.01 to 3.04
Labour Welfare Cess (LWC) as per existing rules on total of Serial item Nos. 3.01 to 3.05
Manning, operation and comprehensive maintenance of central type AC plant of capacities 3x24 TR ESC and 3x5 TR at Logestic lab by providing one skilled refrigeration mechanic each for 02 (two) shifts of 8 hours each, on all days including Sundays & holidays, for trouble free functioning of the installations complete all as specified hereafter and as directed by the Engineer-in-Charge
Skilled refrigeration mechanic (with minimum 2 years experience) (minimum wages as notified)
Contribution towards Employees Provident Fund (EPF) as per existing rules
Contribution towards Employees State Insurance Corporation (ESIC) as per existing rules
Contribution towards Bonus as per existing rules
Contractor's Over Head & Profit on total of serial item Nos. 4.01 to 4.04
Labour Welfare Cess (LWC) as per existing rules on total of Serial item Nos. 4.01 to 4.05
Manning, operation and comprehensive maintenance of central type AC plant of capacities 3x12.5 TR at Storage-I and 3x24 TR at Storage-III by providing one skilled refrigeration mechanic each for 03 (three) shifts of 8hours each, on all days including Sundays & holidays, round the clock for trouble free functioning of the installations complete all as specified hereafter and as directed by the Engineer-in-Charge
Skilled refrigeration mechanic (with minimum 2 years experience) (minimum wages as notified)
Contribution towards Employees Provident Fund (EPF) as per existing rules
Contribution towards Employees State Insurance Corporation (ESIC) as per existing rules
Contribution towards Bonus as per existing rules
Contractor's Over Head & Profit on total of Serial item Nos. 5.01 to 5.04
Labour Welfare Cess (LWC) as per existing rules on total of Serial item Nos. 5.01 to 5.05
Manning, operation and comprehensive maintenance of Package type 02 AC Plant of capacities 3x17 TR (working capacity 2x17 TR) & 2x 11 TR (working capacity 1 x 11 TR) installed at NGCCM by providing one skilled refrigeration mechanic each for 03 (three) shifts of 8 hours each, on all days including Sundays & holidays, round the clock for trouble free functioning of the installations complete all as specified hereafter and as directed by the Engineer-in-Charge
Skilled refrigeration mechanic (with minimum 2 years experience) (minimum wages as notified)
Contribution towards Employees Provident Fund (EPF) as per existing rules
Contribution towards Employees State Insurance Corporation (ESIC) as per existing rules
Contribution towards Bonus as per existing rules
Contractor's Over Head & Profit on total of Serial item Nos. 6.01 to 6.04
Labour Welfare Cess (LWC) as per existing rules on total of Serial item Nos. 6.01 to 6.05
Manning, operation and comprehensive maintenance of central type AC plant of capacities 3x24TR installed at Darin-II 3x26TR installed at ATCC by providing one skilled refrigeration mechanic each for 02 (two) shifts of 8 hours each, on all days including Sundays & holidays, for trouble free functioning of the installations complete all as specified hereafter and as directed by the Engineer-in-Charge
Skilled refrigeration mechanic (with minimum 2 years experience) (minimum wages as notified)
Contribution towards Employees Provident Fund (EPF) as per existing rules
Contribution towards Employees State Insurance Corporation (ESIC) as per existing rules
Contribution towards Bonus as per existing rules
Contractor's Over Head & Profit on total of Serial item Nos. 7.01 to 7.04
Labour Welfare Cess (LWC) as per existing rules on total of Serial item Nos. 7.01 to 7.05
Notes for serial item Nos. 1.00 to 7.06: (i) The timings for each shift shall be as decided by the Engineer-in-charge. No claim whatsoever on this aspect is admissible (ii) Bidder shall quote corresponding minimum wages, rates and contribution as per prevailing Govt. notifications as applicable. Any quoted rate against items / sub-items which corrosponds to / works out to lower than the corrosponding minimum rates of wages / subscription towards EPF, ESIC, bonus and LWC shall be treated as non-bonafide and such bid shall not be considered for acceptance. The prevailing rate / wage / contribution shall be applicable on the bid submission end date (iii) Minimum fair wages as notified time to time by the Government of India / State Government / Local bodies / Labour Regulations whichever is higher including all statutory provisions such as EPF, ESI, Bonus, taxes, etc. as applicable shall be paid to the workers by the Contractor (iv) Increased wages including all other benefits in compliance of statutory provisions shall be paid to the workers by the Contractor. No other claim whatsoever shall be admissible on this account and the bidders shall note this aspect and quote their rates accordingly. It must be noted that in compliance of all statutory provisions, the increase shall be passed over to the workers (v) Conveyance/vehicle for moving around of the staff employed and or any T&P required and detailed specifics as per particular specifications shall be provided by the Contractor. (vi) The maintenance services of chiller units shall be carried out by authorized rep of OEM only. The Contractor shall have to submit MOU of OEM within 15 days of acceptance of the contract.
PART-II (REPAIR & OTHER WORKS)
Dismantling the rusted body of AHU of 20,000 CFM capacity, blower motor, blower shaft, and other spares from AHU for Repairing/ Over-hauling the Body of AHU by replacement of defective components to ensure the proper functioning of the AHU, Re-assemble after necessary repairs, Connecting, commissioning and testing complete all as specified and directed. Notes: (i) The AHU shall be got repaired / Overhauled from specialized Firm or Agency as approved by the Engineer-in Charge (ii) Payment for replacement of parts/ components shall be made for separately under relevant items of this schedule here-in-after
All as per item No 10.00 (here-in-before) but AHU of 14000 CFM capacity
All as per item No 10.00 (here-in-before) but AHU of 12000 CFM capacity
All as per item No 10.00 (here-in-before) but AHU of 10000 CFM capacity
All as per item No 10.00 (here-in-before) but AHU of 6000 CFM capacity
All as per item No 10.00 (here-in-before) but AHU of 2000 CFM capacity
Cleaning of AHU upto 10000 CFM capacity, with hot water and caustic soda mixture with circulating water pump blower / coil shiner, detection of leakage, repair of damaged cooling coils tubes with necessary welding/blazing etc complete and refixing the same, testing on load all as specified and directed.
All as per item No 16.00 (here-in-before) but 10000 to 20000 CFM capacity
Re-Metalling, grinding, polishing to required size, replacement of bearings and greasing of Blower and booster shaft of AC Plants of cap 3x 24 TR all as directed by Eng-in-Charge. Note:-Transportation Charges From site to trade workshop and back to original location after repair and cost of set of bearing is deemed to be included in unit rate quoted.
All as per item No.18.00 (here-in-before) but blower shaft for AC Plants of capacity 3x7.5 to 3x15 TR
All as per item No 18.00 (here-in-before) but blower shaft for AC plants of capacity upto 3x7.5 TR
Dismantling,opening and providing new fan blower set complete upto 3x24 TR from motor cleaning of blower fan with cleaning agent drying with hot air before refixing, replacement of bearings and greasing etc complete with checking of alignment and adjustment of motor and pulley welding balancing of blower complete all as specified and as directed
Rewinding of electric motor of capacity 1 HP, 3 phase operating on 50 HZ 415 volt supply comprising of the following activities: (a) Disconnecting & removing the electric motor of AHU/booster from the installed position and loading / unloading transporting to contractor’s workshop for repairs (b) Dismantling existing burnt winding from the motor, preparing for rewinding complete with super enameled copper winding wire of existing gauge including all insulating materials such as insulation paper, sleeves, tape, varnish etc and painting with two coats of super enamel paint over a coat of primer and greasing of bearings. (c)Loading/unloading/transporting motor to the site, installing in position, alignment, electric connection, commissioning and testing in actual working condition for 8 hours continuously. (d) Motors shall be handed over during the currency of contract on as required basis. Each motor shall be returned duly repaired within 10 days from the date of handing over. Date of commencement of warrantee/ guarantee period of two years shall commence from the date of testing & successful taking over by the department.
All as per item No 22.00 here-in-before but capacity of motor 2 HP 1440 RPM.
All as per item No 22.00 here-in-before but capacity of motor 5 HP 1440 RPM.
All as per item No 22.00 here-in-before but capacity of motor 7.5 HP 1440 RPM.
All as per item No 22.00 here-in-before but capacity of motor 15-25 HP 1440 RPM.
Taking out the primary burnt/unserviceable finned strip heaters from existing position of the AHU complete with fitting arrangement from different location and supply & fixing the same of capacity 3500 watt in AC plants in position complete with fitting arrangement and testing the complete all as specified and as directed
M&L for replacement of heater deemed for hot water generator upto Cap 18 KW as per sample complete all as directed by Engr-in-Charge.
M&L for spray gun painting of with cost of red oxide and grey/blue paint upto two coats on rusted/corroded AHU enclosure fitments and pipes by removing peeled old paint with scrapper painting two coat of synthetic enamel paint as per standard shade and colour complete all as specified and as directed
S&F in replacement thermal expansion valve of Model No TDEX11 TR complete all as specified and as directe
All as per item No 30 here-in-before but capacity 11 TR, Model No HFES-10HW-100, all as specified and as directed
Taking out unserviciable wiring of panel/control system of AHUs rewiring the same with new suitable capacity of copper conductor PVC insulated wire and making connection to make the control/interlocking system functional complete all as specified and as directed
M&L for sheet metal enclosures for fixing humidity controller and chilled water flow controller with transformer of 24V step down transformer control wiring complete all as specified and as directed
M&L for Humidity controller model H-6000 complete all as specified and as directed
M&L for Chilled water flow meter model Actuator ART 2-24F complete all as specified and as directed
S&F In repairs fan blade for Cooling tower of Size 18" to 30" required as per existing size and model complete all as specified and as directed
Taking down PVC fins of cooling tower and supply and fixing new fins as per existing model and size as required complete all as specified and as directed
Supply only MCCB capacity of 100 Amp 25 KA confirming to (IEC-60947-2) ( 4P) and protection form short circuit and overload complete all as specified and as directed
Supply only MCB TP of 63 Amp, 415 Volt complete all as specified
Supply only MCB TP 40 Amp 415 Volt complete all as specified
Supply only MCB TP of 32 Amp 415 Volt complete all as specified
Supply only MCCB capacity of 25 Amp 16 KA conforming to (IEC-60947-2) ( 3P) and protection form short circuit and overload
Supply only digital Voltmeter suitable for 0-500 volts 96 sqmm, complete all as specified
Supply only digitgal Ampere meter 96 Sqmm suitable for 100 Amps complete all as specified
Supply only a set of indicator bulbs Red,Blue and Green Phases ISI marked complete all as specified
Supply only Rotary switch 5 Amp Red,Blue and Green Phases ISI marked complete all as specified
Supply only On-Off switch to start and stop the AHU motors (Set of Two) complete all as specified
Supply only scrool type compressor 12.5TR three Phase 415 Volts, 50 Hz of complete all as specified
Supply, installation, testing and commissioning of acoustic insulation of duct with 25 mm resin bounded fiber glass of 48 kg/cum density, covered with 28 SWG aluminium perforated sheet complete all as specified and as directed
Supply only Galvanized steel sheet of 22 SWG (0.80 mm thick Gauge) complete all as specified and as directed
Supply only Nut bolts & screws as per existing size complete all as specified and as directed
Supply only Iron Angle of size 30mm x 30mmx3mm complete all as specified and as directed
Supply only Blower shaft bearing UCP type complete with housing as per existing size as approved complete all as specified and as directed
Supply only V type Fan belt bearing cat part No A53/A64/A65/B101 as per existing size as approved complete all as specified and as directed
Supply only Motor Shaft V-Belt Pully with two groove 3" dia of existing make as approved complete all as specified and as directed
Supply only Blower Shaft V-Belt Pully with two groove 12" dia of existing make as approved complete all as specified and as directed
Supply only Sprinkler PVC for cooling tower of different capacity of existing make as approved complete all as specified and as directed
Supply only Tie Rod with strainer and clamp for cooling tower of existing Aluminium distribution 120mm link as approved complete all as specified and as directed
Supply only Aluminium distributor Hub for Standard bore pipe as approved complete all as specified and as directed
Supply only PVC distribution pipe 80mm bore with HDPE flaper as approved complete all as specified and as directed
Supply and topping up of compressor oil as per existing grade as required as approved complete all as specified and as directed
M&L for taking down pump from site transporting to workshop, repairing by supply and fixing any damaged parts including necessary machine work, and refixing at site of capacity 3 HP to 15 HP as approved complete all as specified and as directed
Supplying and Re-Charging of refrigerant Gas R-22 in Central/Package type AC plant after detection of leakage & rectification of same in the system by using Carbon Di-oxide Gas and flushing the complete system throughly with Nitrogen gas complete all as specified and directed. Notes: (a) Gas shall be brought by the contractor at Site from authorised Dealer/ Manufacturer company's sealed cyclinder of standard packings with test certificate and P.V. and re-filling shall be done in the presence of rep of Deptt. The empty cylinders after using the gas brought shall be returned to the contractor & for payment purppose, only gas to the required extent used for charging shall be considered (b) The unit rate quoted is inclusive of cost of Nitrozen gas & CO2 gas required for leakage test to pressure test.
Supplying and Re-Charging of refrigerant Gas R-134/407 in Central/Package type AC plant after detection of leakage & rectification of same in the system by using Carbon Di-oxide Gas and flushing the complete system throughly with Nitrogen gas complete all as specified and as directed Note: (a) Gas shall be brought by the contractor at Site from authorised Dealer/ Manufacturer company's sealed cyclinder of standard packings with test certificate and P.V. and re-filling shall be done in the presence of rep of Deptt. The empty cylinders after using the gas brought shall be returned to the contractor & for payment purppose, only gas to the required extent used for charging shall be considered. (b) The unit rate quoted is inclusive of cost of Nitrozen gas & CO2 gas required for leakage test to pressure test.
Replacement electric motor/ of capacity 10 HP, 3 phase, 50 Hz, 415 volt, 1440 RPM (any make) including disconnecting and dismantling of electric motor of cooling tower/sewage pump/diaphram doser installed at any position, cutting of the burnt copper coil, cleaning of stator, rewinding with and including super enamelled copper conductor wire of sutable size & guage (all as per existing) complete, servicing with provision of insulation paper, packing, threads, sleeves etc. drying machining, welding, cleaning, greasing of bearings etc. recomissioning and testing on full load complete all as specified and directed . Notes: 1. Quoted rates shall also be deemed to be inclusive of loading, unloading, transporting of motor/pump sets, installing in position, setting alignment, making electric connections, commissioning and testing for 8 hour continuously in actual working conditions. 2. Motors shall be handed over during the currency of Contract on as required basis . 3. Each motor shall be returned duly repaired within 10 days from the date of handing over to the contractor for re-winding. 4. Quoted rates shall be deemed to be inclusive of Guarantee period of one year which shall commence from the date of testing & sucessful taking over by the Department.
M/S Trilok chand sharma
m/s parmod kamar
NAVREET CONSTRUCTION
Baliyan Electrical Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .