Tender Value
₹5.4 L
EMD Value
₹10,800
Closing Date
12 Sept 2026, 3:00 pm
AGM (EM)
FCI RO Itanagar
Annual Repairs and Maintenance Contract for electrical and mechanical services alongwith requisite materials at FSD Kharsang and FSD Pasighat under DO Pasighat for FY 26-27
2026_FCI_924191_1
02/Engg/EM/Aru/2026-27
Open Tender
Electrical Works
Percentage
365 days
FCI FSD Kharsang and Pasighat
As per tender documents
2 documents required · 2 mandatory
₹0
₹10,800
FCI RO Itanagar
31 Aug 2026
31 Aug 2026
14 Sept 2026
31 Aug 2026
12 Sept 2026
31 Aug 2026
7 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Repairs and maintenance of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules. a) E.I., Lights/Fans/Plug points/ Powerpoints and Street/ Compound lighting arrengements as per I.E. Rules as detailed inside at page. b) Water supply arrangement c) Water cooler (Electrical) d) Air coolers e) Air conditioners (Electrical) f) Feeder pillars/LT panels maintenance g) Transformer (preventive) I) High Mast Lighting | |||||
| 1.1 | One Wireman for 2 days a week at FSD Kharsang | 104 | Days | 1,334 | ₹1,38,736 |
| 1.2 | One Helper for 2 days a week at FSD Kharsang | 104 | Days | 949 | ₹98,696 |
| 1.3 | One Wireman for 2 days a week at FSD Pasighat | 104 | Days | 1,334 | ₹1,38,736 |
| 1.4 | One Helper for 2 days a week at FSD Pasighat | 104 | Days | 949 | ₹98,696 |
| 2 | Supplying of 20 watt LED surface mounted Batten light (System lumen efficacy > 135 lm/watt) of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) | 20 | Each | 527.91 | ₹10,558.2 |
| 3 | Supplying of 45 watt Street light LED fixture, powder coated pressure die cast aluminium body(System lumen efficacy >135 lm/Watt) with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65 mm dia pipe, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | 10 | Each | 1,707.34 | ₹17,073.4 |
| 4 | Supplying of 100 watt LED Flood light, powder coated pressure die cast aluminium body(System lumen efficacy >135 lm/Watt) with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | 5 | Each | 2,308.28 | ₹11,541.4 |
| 5Supply of FRLS PVC Insulated copper conductor single core cable of following sizes | |||||
| 5.1 | 1.5 sqmm | 270 | Mtr | 24.92 | ₹6,728.4 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
DNIT_AMC_Kharsang_Pasighat.pdf
Tender Documents • 1.30 MB
EMDproforma.pdf
Additional Documents • 0.22 MB
BOQ_971179.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].