Tender Value
₹9.1 L
EMD Value
₹18,159
Closing Date
20 Apr 2026, 12:00 pmClosed
Executive Engineer (E)
O/o EE(E) PWD EMD M-351, R.No.185, Old Sectt Delhi
RMO EI Fans, Pump Sets, Sub-Station, AC Equipment at Transport Authority, 5/9 Under Hill Road, Delhi. (SH- Repairing of existing faulty of Split Type and Window Type AC Unit 1.5 / 2.0 TR).
2026_PWD_289838_1
06/2026-27/EMD M-351/EE(E)
Open Tender
Miscellaneous Services
Percentage
15 days
Transport Authority
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹18,159
23 Apr 2026
13 Apr 2026
20 Apr 2026
13 Apr 2026
20 Apr 2026
13 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Installation, Testing and Commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature) i/c wall bracket / stand i/c credit of old Dismantle Material etc. complete as required. Non Inverter Type - Cooling only (Make :- Toshiba / Bluestar / Hitachi / Mistibushi/Voltas / Carrier / Daikin) | |||||
| 1.01 | 1.5 TR with Minimum 3 star BEE Rating | 5 | Nos. | 37,559 | ₹1,87,795 |
| 2Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for Split/Window AC System complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required (Make Mandev / Total line / Mettube /Rajko / Diamond / star) | |||||
| 2.01 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation | 10 | Mtrs. | 256 | ₹2,560 |
| 2.02 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation | 10 | Mtrs. | 346 | ₹3,460 |
| 2.03 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation | 10 | Mtrs. | 487 | ₹4,870 |
| 2.04 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation | 10 | Mtrs. | 615 | ₹6,150 |
| 3Supply and charging of R-22/R-32/R-410 gas in the split type Air Conditioning unit / Window type AC including pressure testing, leak detection, vaccumisation, replacement of filter and capillary testing and commissioning etc as required. | |||||
| 3.01 | 1.5 / 2.0 TR capacity split type unit / Window type AC. | 50 | Nos. | 1,981 | ₹99,050 |
| 4Supplying, Installation, Testing & commissioning of new compressor for WTAC/Split AC of emerson or existing similar make i/c brazing copper refrigerant piping, pressure testing, flushing, dehydration, vaccumising of the unit replacement of required copper pipe, filter etc. i/c dismantling old compressor etc complete as reqd. (make Danfoss / Kirloskar / Hitachi / Voltas) | |||||
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.18 MB
06TransportAuthorityRepairingfalultySplitWindowAC.pdf
Tender Documents • 2.16 MB
BOQ_384853.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .