Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC L1 AND REASONABLE | |
| 2 | L2₹27.3 L+₹41,048.05 (1.52%)Rejected-Finance | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹27.9 L+₹97,202.10 (3.61%)Rejected-Finance MAHARAJA SOCIETY HAPA YARD ROAD NR ALFA PAN STREET NO 6 O S KALWADGET JAMNAGAR GUJ | L3 | Rejected-Finance NOT L1 |
| Sl No | Description | Qty | Unit | badri glass and construction L2 | sanu enterprise L3 | M/S Badri Electicals L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down all existing roof treatment and demolition of cement concrete padding/levelling course incl wire brushing and cleaning loose dust etc from surfaces of RCC roof incl flashing and junction of parapet complete all as specified and directed by engineer in charge. | 284.3 | Sqm | 34 ₹9,666.2 | 30 ₹8,529 Lowest | 40 ₹11,372 |
| 2.00 | M&L Average 25mm thk Cement concrete type B-0, 1:2:4 (Using 12.5mm graded stone aggregate) as in levelling course/padding with slope 1:40 complete all as specified and directed by engineer in charge. | 230.05 | Sqm | 151 ₹34,737.55 | 150 ₹34,507.5 | 140 ₹32,207 Lowest |
| 3.00 | M&L 10 mm thick screed bed in CM (1:3) mixed with waterproofing compound on padding layer for roof treatment all as directed and as specified by Engr-in- Charage. (Note :- WPC shall be measureded and paid seperately on supply only.) | 284.3 | Sqm | 128 ₹36,390.4 | 100 ₹28,430 Lowest | 120 ₹34,116 |
| 4.00 | Supply only liquid waterproofing compound complete all as specified and directed by engineer in charge. | 105.59 | kg | 51 ₹5,385.09 Lowest | 200 ₹21,118 | 53 ₹5,596.27 |
| 5.00 | M & L for water proofing treatment to non-accessible roof slabs by applying one coat of bituminous primer conforming to IS-3384 @ 0.30 litre/sqm and laying Actitic Polypropylene (APP) modified membrance , reinforced with non woven ployester, of 3.50 Kg/sqm (minimum, 3mm thick (minimum), with minimum 75 mm side overlaps and 100mm end overlaps and applying one coat of bituminous aluminium paint over APP membrane all as specified and directed by Engineer-in-Charge. | 284.3 | Sqm | 400 ₹1,13,720 Lowest | 400 ₹1,13,720 Lowest | 421 ₹1,19,690.3 |
| 6.00 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed by engineer in charge. | 65.73 | 10 Sqm | 300 ₹19,719 | 50 ₹3,286.5 Lowest | 300 ₹19,719 |
| 7.00 | M&L 20mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by engineer in charge. | 9.54 | Sqm | 3,000 ₹28,620 | 4,000 ₹38,160 | 2,800 ₹26,712 Lowest |
| 8.00 | Moulding to Granite(single or double) slab including rounding off edges for 20 mm thick slabs including grinding and polishing complete all as specified and directed by engineer in charge. | 15.9 | Rm | 72 ₹1,144.8 Lowest | 100 ₹1,590 | 80 ₹1,272 |
| 9.00 | Machine cut kota stone slab flooring 20-25mm thick over 20 mm thick CM 1:4 bedding layer laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by engineer in charge. | 29.97 | Sqm | 900 ₹26,973 Lowest | 1,000 ₹29,970 | 1,000 ₹29,970 |
| 10.00 | M&L for Machine cut kota stone slab 20-25 mm thick in riser of step ,skirting, dado,vertical partition and pillar laid over cement screed etc, piece machine polished laid over and jointed in cement slurry and pointed in grey cement and pigment to match the colour of slab,10mm thick rendering as in backing coat for skirting/dado in CM (1:3) with on wall surfaces complete all as specified and directed by engineer in charge. | 29.2 | Sqm | 1,400 ₹40,880 | 1,000 ₹29,200 Lowest | 1,100 ₹32,120 |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
9 Aug 2025, 6:00 pmClosed
GE A JAMNAGAR
INFANTRY LINES JAMNAGAR
SPECIAL REPAIR (EXCLUDING WINDOW AND CERTAIN TOILET DOORS) TO BLDG NO P- 438 (6 X QTRS) (JCOS MD ACCN) AT DWARKA ENCLAVE IN MIL STN JAMNAGAR
2025_MES_719121_1
8155
Open Tender
Civil Works
Item Rate
180 days
JAMNAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY JAMNAGAR
₹77,000
10 Sept 2025
8 Jul 2025
11 Aug 2025
9 Jul 2025
9 Aug 2025
21 Jul 2025
Amount
Taking down all existing roof treatment and demolition of cement concrete padding/levelling course incl wire brushing and cleaning loose dust etc from surfaces of RCC roof incl flashing and junction of parapet complete all as specified and directed by engineer in charge.
M&L Average 25mm thk Cement concrete type B-0, 1:2:4 (Using 12.5mm graded stone aggregate) as in levelling course/padding with slope 1:40 complete all as specified and directed by engineer in charge.
M&L 10 mm thick screed bed in CM (1:3) mixed with waterproofing compound on padding layer for roof treatment all as directed and as specified by Engr-in- Charage. (Note :- WPC shall be measureded and paid seperately on supply only.)
Supply only liquid waterproofing compound complete all as specified and directed by engineer in charge.
M & L for water proofing treatment to non-accessible roof slabs by applying one coat of bituminous primer conforming to IS-3384 @ 0.30 litre/sqm and laying Actitic Polypropylene (APP) modified membrance , reinforced with non woven ployester, of 3.50 Kg/sqm (minimum, 3mm thick (minimum), with minimum 75 mm side overlaps and 100mm end overlaps and applying one coat of bituminous aluminium paint over APP membrane all as specified and directed by Engineer-in-Charge.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed by engineer in charge.
M&L 20mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by engineer in charge.
Moulding to Granite(single or double) slab including rounding off edges for 20 mm thick slabs including grinding and polishing complete all as specified and directed by engineer in charge.
Machine cut kota stone slab flooring 20-25mm thick over 20 mm thick CM 1:4 bedding layer laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by engineer in charge.
M&L for Machine cut kota stone slab 20-25 mm thick in riser of step ,skirting, dado,vertical partition and pillar laid over cement screed etc, piece machine polished laid over and jointed in cement slurry and pointed in grey cement and pigment to match the colour of slab,10mm thick rendering as in backing coat for skirting/dado in CM (1:3) with on wall surfaces complete all as specified and directed by engineer in charge.
S&F Coloured Vitrified tiles 10 mm thick (square/rectangular) polished area of each tiles n exc 0.36 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match in light shade including 15 mm thick screed bed in CM 1:4 complete all as specified and directed by engineer in charge.
S&F Coloured Vitrified tiles 10 mm thick (square/rectangular) polished area of each tiles n exc 0.36 sqm in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match in light shade including 10 mm thick plaster in CM 1:3 complete all as specified and directed by engineer in charge.
M & L Non skid coloured ceramic tiles 7-8mm thick area of each tiles exceeding .06 Sqm but not exceeding .11 Sqm, in floors etc. set and jointed in neat cement slurry mixed with water proofing liquid compound and pointed in white or coloured grouting chemical to match , over 15mm thick screed bed in CM 1:6 complete all as specified and directed by engineer in charge.
M&L Glazed ceramic coloured designer tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match 0ver 10mm thick plaster in cement mortar (1:3) complete all as specified and directed by engineer in charge.
Demolition of in lintels, chajja,manole cover landing,slab, parapet stair case of cement concrete reinforced of similar suspended works complete all as specified and directed by engineer in charge.
M & L RCC nominal mix type B1 1:2:4 using 20mm graded aggregate as in chajja, parapet etc and incl necessary formwork complete all as specified and directed by engineer in charge.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including binding with mild steel wire (annealed) not less than 0.9mm dia. complete all as specified and directed by engineer in charge.
Demolition of brick work/stone masonry built in cement mortar of any description complete all as specified and directed by engineer in charge.
M&L for old size brick work with sub class `B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 as in repairs. complete all as specified and directed by engineer in charge.
Taking down Doors chowkat or frame n exc 1.5 Sqm but with shutters (without taking off shutters from the frames) and removing out of site. complete all as specified and directed by engineer in charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area exc 1.5 sqm but n.exc 4.0 sqm complete all as specified and directed by engineer in charge.
Taking down shutters of any description exc 1 sqm but n exc 2sqm complete all as specified and directed by engineer in charge.
Refixing in same opening shutters of any description exc 1 sqm but n exc 2 sqm complete all as specified and directed by engineer in charge.
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed by engineer in charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified and directed by engineer in charge.
S&F Pressed steel frames for doors size 125 mm X60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed by engineer in charge.
S&F Pressed steel frames for doors size 105 mm X60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,complete all as specified and directed by engineer in charge.
S & F Framed work as in doors/door frame or gates of angle or other section with gusset plates rails, braces, etc complete drilled for fixing of steel sheeting other covering, doors, etc to be prepared handing or sliding with and including either hooks and hinges or steel hanging door fitting and hanging also fastering and fixing complete all as specified and directed by engineer in charge.
M&L PCC type B0, 1:2:4 (12.5 mm graded aggregate) filling in door and frames, any size, single or double rebated, including arrangements all as specified and directed by engr in charge
M&L applying one coat of black bituminus paint on Surfaces of any description wood,steel, iron, concrete, brick, stone, etc., exceeding 10cm in width or girth complete all as specified and directed by engineer in charge..
S&F factory made 35mm thick 2nd class hard wood glzed & skeleton door shutters,open rebated and prepared to recieve gauge etc(without sash bars) edgs of framing plain, chamfered or etc,size of members of shutters as specified in SSR Pt-I, Sec-8 Clause 8.20 (a) without sash bar etc complete all as specified and directed by engineer in charge.
S&F mild steel of grade Fe-290 (Grade E-165) in framed work such as grills, grating etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders; ramed balusters; walk ways; railings; framework of water tanks and similar works. complete all as specified and directed by engineer in charge.
S&F 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (any number of Panel) with lock rail and panel of 12 mm thick veneered particle board with commercial veneering on both faces,. The size of rail and styles as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated. complete all as specified and directed by engineer in charge.
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or stainless steel wire staples or with second class hard wood beadings in any type of door complete all as specified and directed by engineer in charge.
S&F 300mm , ordinary rat tail rod pattern springs including roller and roller plate fixed etc with screw/ welding etc as required at site complete all as specified and directed by Engr-in-charge.
M&L preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by engineer in charge.
M&L preparation of new untreated Steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome complete all as specified and directed by engineer in charge.
S&F Aluminium, anodised, barrel tower bolts of extruded section and fixed 150mm complete all as specified and directed by engineer in charge.
S&F Aluminium, anodised, barrel tower bolts of extruded section and fixed 150mm long fixed in repairs complete all as specified and directed by engineer in charge.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed 250 mm long complete all as specified and directed by engineer in charge.
S&F in Aluminium handles, cast type, anodised 150mm long complete all as specified and directed by engineer in charge.
S&F in Aluminium handles, cast type, anodised 150mm long fixed in repairs complete all as specified and directed by engineer in charge.
S&F Floor door stopper of aluminium alloy body and tongue, anodised, 140 mm with hard drawn steel spring, fixed in floor complete all as specified and directed by engineer in charge.
S & F 100mm Butt hinges, extruded aluminiumalloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed by engineer in charge.
S & F in repairs 100mm Butt hinges, extruded aluminiumalloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed by engineer in charge.
S&F SS Curtain Rod Decorative pattern as approved by Engr-in-Charge. In repairs
S&F SS Curtain Rod Bracket decorative type all as directed and approved by Engr-in-Charge in repairs
Dismantling exc 500 and n exc 1000 ltr water tank removing to store complete all as specified and directed by engineer in charge.
S&F 1000ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position with 20mm ball/float valve complete all as specified and directed by engineer in charge.
Taking down steel tubing and connections including cleaning for refixing or removal to store of 15 mm dia.complete all as specified and directed by engineer in charge.
Taking down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed by engineer in charge.
Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape complete to walls and ceilings or laid in floors including all connected brass cpvc fittings and cutting grooves, filled with CM1:6 complete all as specified and directed by engineer in charge.
Supplying and laying of 25 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape in any requirement complete to walls and ceilings or laid in floors iincluding all connected brass cpvc fittings and cutting grooves, filled with CM1:6 complete all as specified and directed by engineer in charge.
Demolition of cement concrete (un-reinforced) in any position not otherwise specifically provided complete all as specified and directed by engineer in charge.
M&L for 40 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate mixed with liquid water proofing compound @ 3% of cement in bottom of sunken floors. complete all as specified and directed by engineer in charge.
M&L Cleaning vertical and horizontal surfaces of sunken slab using wire brushing followed by sanding with emery paper for loose materials/dust and applying two coats of epoxy resin component (Dr. Fixit DAMPGUARD or equivalent) solution/mix using nylon brush pouring Base part in appropriate container followed by the Hardner part and mix thoroughly to attain homogeneous smooth paste and dilute the mixed compound with water in ratio 1 part Base: 1 part Hardner: 1 part water by slow addition and mix thoroughly until a brushable consistency is obtained, first coat will be allowed to dry for 6 to 8 hrs before application of second/final coat) incl curing treated surface for 24 hrs complete incl applying evenly a coat of blown bitumen @ 1.5kg/sqm over entire treated surfaces incl spout holesbefore filling lean concrete complete and all as specified as per manufacturer instruction. complete all as specified and directed by engineer in charge.
M&L 15mm thick rendering in cement plaster 1:3 with WPC on bottom and side walls of sunken floor incl finished even and smooth w/o using extra cement complete all as specified and directed by engineer in charge.
M&L filling PCC type E-2 1:5:10 (40 mm graded stone aggr) as in sunken floor after applying appropriate treatment to side walls complete all as specified and directed by engineer in charge.
M&L 75 mm thick Cement concrete type C-2, 1:3:6 (40 mm graded aggregate) as in plinth protection complete all as specified and directed by engineer in charge.
Forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade A complete all as specified and directed by engineer in charge.
Taking down cement plaster on brick/stone or concrete surfaces including racking out joints, hacking for key,scrubbing down with water to receive plaster including necessary all scaffolding complete all as specified and directed by engineer in charge.
M&L for rendering 10mm thick on fair faces of brick/stone work or concrete surfaces in CM 1:6 finishing the surface even and even smooth without using extra cement..complete all as specified and directed by engineer in charge.
M&L 15 mm thick rendering in in two layers 5mm thick inCM 1:4,over 10mm thick cement plaster in CM 1:6 on fair face of brick work/Stone or concrete surface to be finished even and smooth without using extra cement Including WPC compound 3% by weight of cement.(Note :a) Intergial WPC Compound shall be used in sencond layer,b) Intergial WPC shall be paid seperately on supply only complete all as specified and directed by engineer in charge..
M&L for rendering 5 mm thick in CM 1:3 on ceiling to be finished complete all as directed by Engr-In-Charge
M&L preparation of newly plastered surfaces of walls for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed by engineer in charge.
M&L for preparation of new plastered surface of wall and applying primer two coat of oil bond distemper and 2 mm putty complete all as specified and directed by engineer in charge.
M&L for preparation of new plastered surface of ceiling and applying three coats of white wash.complete all as specified and directed by engineer in charge.
Material and labour for complete removal of existing treatment from plastered or unplastered surfaces of walls including cleaning with scrapers, any number of coats and any width or girth etc, the area of application should be cleaned thoroughly, remove all dirt, dust and uneven elements from the surface by washing and scraping and all the unevenness in the surface should be corrected by filling the exterior wallcare putty, surface should be sanded down with fine grade sand paper for smoothness and applying one coat of exterior primer and 02 coats of Exterior Weather Coat Emulsion Paint of white or tinted shade(any colour) as per manufacturer instruction complete all as specified and directed by engineer in charge.
Complete Removal of existing treatment on ceiling and applying two coats of white wash a complete all as specified and directed by engineer in charge.
Complete Removal of existing treatment on wall and applying two coats of oil bond distemper and 3 mm putty complete all as specified and directed by engineer in charge.
S&F in repair Vitreous china wash basin, white , flat back , size 550 x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets fixed in repairs .complete all as specified and directed by engineer in charge.
S&F in repairs PVC(SWR) pipe 110 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors. complete all as specified and directed by engineer in charge.
S&F in repairs PVC(SWR) pipe 110 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints fixed to walls. complete all as specified and directed by engineer in charge.
S&F in repairs PVC(SWR) pipe 75 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors. complete all as specified and directed by engineer in charge.
S&F in repairs PVC(SWR) pipe 75 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints fixed to walls. complete all as specified and directed by engineer in charge.
S&F in repairs 110mm PVC (SWR) single T equal or unequal complete all as specified and directed by engineer in charge.
S&F in repairs PVC(SWR) bend any radius, 110 mm dia. complete all as specified and directed by engineer in charge.
S&F in repairs PVC(SWR) bend any radius, 75 mm dia. complete all as specified and directed by engineer in charge.
S&F in repairs PVC(SWR) Tee any radius, 75 mm dia. complete all as specified and directed by engineer in charge.
S&F in repairs 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent. complete all as specified and directed by engineer in charge.
S & F Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms) complete all as specified and directed by engineer in charge.
S&F in repairs 110 mm dia PVC (SWR) vent cowl complete all as specified and directed by engineer in charge.
S&F fancy type CP bib taps, 15 mm bore with crutch or , screwed down, fixed as in repairs. complete all as specified and directed by engineer in charge.
S&F in repairs Pillar taps 15 mm dia, cast copper alloy , with capstan heads, chromium plated , screwed down high pressure ,with long screwed shanks and fly-nuts , screwed for iron pipe/cpvc pipe and fixed. complete all as specified and directed by engineer in charge.
S&F in repairs stop valve chromium plated with l 15 mm dia screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions and fixed. complete all as specified and directed by engineer in charge.
S&F in repairs Brass CP three way wall Mixer for mixing hot & Cold water screwed down for iron pipe and fixed. complete all as specified and directed by engineer in charge.
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern) with 'P' or 'S' trap, white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed by engineer in charge.
S & F plastic water closet seat for pedestal pan,black(coloured) closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device and complete all as specified and directed by engineer in charge.
S&F Stop cock two way 15 mm bore cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed all ends for iron pipe or for unions and taking down old stop cock. complete all as specified and directed by engineer in charge.
S&F CP Health Faucet with 1.50mtr tube & Hook any description including flexible attachment as,specified and directed by Eng-in-charge.
S&F Waste fittings,32mm brass , chromium plated for glazed ware sinks , basins , etc. with long screwed shanks and fly -nuts , flange end bedded in red lead cement and other end fixed complete all as specified and directed by engineer in charge.
S&F in repairs 32 mm bore PVC waste pipe with fittings of approved make suitable for WHB, Urinals etc complete all as specified and directed by engineer in charge.
S&F PVC connections 15 mm size with PTMT nuts of length 600mm complete all as specified and directed by engineer in charge.
S&F 15 mm bore Chromium plated shower roses with or without swivel joints, any size, including fixing to steel/cpvc pipe or union in repairs. complete all as specified and directed by engineer in charge.
S&F Tubular towel rail, brass CP 20mm dia, D type, 60cm long between flanges in repairs complete all as specified and directed by engineer in charge.
S/F in repairs PVC valveless syphonic action type ,flushing cistern Low level white,with,with inlet ball valve ,float and handle 10 Ltr capacity including brackets. complete all as specified and directed by Engineer in charge.
S& F in repair Sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by engineer in charge.
S&F Stainless steel Kitchen plate racks 1mm thick over all size 24" x30" x10". complete all as specified and directed by engineer in charge.
Removal of all loose/unsound/bad/damaged concrete or plaster existing RCC structure of slab/beams/walls/chajja by using chesel/hammar .Cut and remove unsound reinforcement bars, wires etc without damaging the sound reinforcement . clean loose rust from bars manually with brush . fixing new supplymentary bars if required,either by tying it with existing bars or by welding on it. Applying eppoxy bonding agent and making good with polymer modified plaster/micro concrete as required thickness over a coat of rust removing alkaline primer and match the finishing to the existing surface in ground floor including formwork complete all as specified and directed by engineer in charge.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and directed by Engineer in charge.
Removing excavated materials to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m from starting point. complete all as specified and directed by Engineer in charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified and directed by engineer in charge.
Demolition and breaking up sewage drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar (Internal dia of pipe in 200 mm) complete all as specified and as directed by the Engineer-in-Charge.
S&F DWCPE (SN8) pipes, nominal dia 200 mm laid in trenches for sewer network, fixed and jointed with integral socket or coupler and EPDM sealing ring (depending on pipe ends) as per manufacturer instructions complete all as specified and as directed by Engr-in-Charge (Make (DWCPE Pipe) : Supreme, Prince, Berlia or equivalent as specified )
M&L for cement concrete bedding and haunching against the sides of pipes after they are laid to 200 mm bore drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) laid to falls including packing under, and tested, complete all as specified and directed by Engineer in charge. NOTE :- Pipe shall be measured and paid separately).as in repairs.
Demolition for reinforcement cement concrete complete all as specified and directed by Engineer in charge.
M&L for precast RCC 1:2:4 type B1 using 20mm graded stone aggregate in cover slabs including necessary form work etc for manholes covers set in CM 1:4 (reinforcement measured seperately)
M&L for TMT bars 6 to 8mm dia and over cut to length bent to shape required including bending and binding with and including MS wire annealed not less than 0.9mm dia complete all as specified and directed by Engineer in charge.
Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) including suface excavation and removing debris outside MD Land complete all as specified and directed by Engineer in charge.
M & L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface. complete all as specified and directed by Engineer in charge.
M&L 75mm thick PCC type C-2, 1:3:6 (40mm graded stone aggt) as in path, hard standing, parking floors, etc., complete all as specified and directed by engineer in charge.
Demolition of Stone slabs and tiles (Interlocking ) laid dry of any description or thickness in floors, aprons etc. complete all as specified and directed by engineer in charge.
M&L sand cushing/filling under paver block complete all as specified and directed by engineer in charge.
S&F Machine pressed precast Concrete interlocking paver block any shape and size with grey/colour cement and pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 grade complete all as specified and directed by Engineer in charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand),including making joints with or without grooves(thickness of joints except at sharp curve shall not to more than 5 mm ), including making drainage opening wherever required complete all as specified and directed by Engineer in charge.
S&F in powder coated aluminium fixed louvered ventilator, frame of section 63.5mm X 38.1mm X 1.01 mm or appropriate equivalent section with 4 mm thick figured/frosted sheet glass with rubber gasket,Aluminium wire mesh, handles, locking arrangement etc incl making good jambs, cills etc and including taking down old iron ventilator complete all as specified and directed by the Engr-in-Charge.
Dismantling boardings, any description, fixed in any position with screws complete all as specified and directed by Engineer in charge.
M & L 18/19mm thick Pre-laminated particle board, interior grade, prelamination one side with decorative choice lamination & other side balancing white lamination, fixed with nails as in cupboards / cabinets incl locking arrangement .
S&F 18/19 mm wide 6 mm thick lipping on veneered particle/pre-laminated particle as in cupboard shutter and shelves.
S&F in repairs 2nd class hardwood plain fillet square rectangular in section wrought sawn secured with screws exc 13 & n exc 25 sqcm in section all as specified and as directed by Engineer-In-Charge..
S&F75 mm butt hinges,extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed,tupe C21 complete all as specified and directed by Engineer in charge.
S&F Extruded aluminium alloy handles 100mm long, fabricated type, anodised. complete all as specified and directed by Engineer in charge.
S&F Aluminium anodised 75mm hasp and staple ,safety type with hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed by Engineer in charge.
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed by Engineer in charge.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed by Engineer in charge.
Taking down existing geyser of any capacity after disconnecting all necessary electrical and water supply connections and deposit to MES store yard of AGE E/M Jamnagar complete all as specified and directed by Engineer in charge.
Taking down ceiling fan/ Exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M Jamnagar complete all as specified and directed by Engineer in charge.
Taking down existing energy meter from site and deposit to MES storeyard and refixing the same meter after completion of work complete all as specified and directed by Engr-in-Charge.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :-
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
(c) One light point controlled by one, two way switch 5 Amps
(d) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
(e) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
(f) One bell point controlled by one, bell switch 5 Amps
Description all as per item No 133 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. (power point)
Description all as per item No 133 here in before but using 4.0 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 15 amps switch socket cobmination point including necessary running of 4.0 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. (power point)
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and,cutting chases for concealed water,tubing or concealed conduit wiring,,etc., and making good, cutting not,exc 10 cm girth ® (stone massonary)
S & F for modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified and directed by engineer in charge.
S & F for modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified and directed by engineer in charge.
S & F for modular switch piano flush type, single pole, two way, and 5/6 Amp single module complete all as specified and directed by engineer in charge.
S & F for modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed by engineer in charge.
S & F for modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed by engineer in charge.
S & F for modular step type fan regulator (BLDC) 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and directed by engineer in charge.
S & F for Bell push modular 6 Amps single module complete all as specified and directed by engineer in charge.
S & F for metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and as directed complete all as specified and directed by engineer in charge.
S & F for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and directed by engineer in charge.
S & F for ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and directed by engineer in charge.
S & F for lamp holder, PVC / Polycarbonate type with back plate suitabl for batten/ slanting fittings complete all as specified and directed (Kitchen).
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 4 sqmm cable,one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit
S & F for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed by engineer in charge.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed by engineer in charge.
S & F for MCB Tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and directed by engineer in charge.
S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and directed by engineer in charge.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and directed by engineer in charge.
S & F for ceiling fan, 230 Volts, 1200 mm sweep with mian air delivary 210 CFM, service value of the fan shall be greater than 6.1 (5 star rated) as per BIS with blades, down rod & other necessary accessories with brushless direct current motor (BLDC) with out remote system and electrical connections from ceiling rose to fan teriminal complete all as specified and directed by engineer in charge.
S & F for Highly efficient LED Bulbs, 10 W, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap of make Bajaj, Havells, HPL complete all as specified and directed by engineer in charge.
S & F for Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired with warranty option of 5 years from date of installation and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed. Make :- Bajaj Cat No BIBWP 10W LED or its equvalent in Philips, Wipro.
S & F for LED tube light fitting 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and as directed.
S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make :- Make Bajaj Cat part No BCLAB 20W WH LED P, Wipro Cat part No LL20-281-XXX065-ALI or its equvalent in Philips, Havells.
S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Make :- Bajaj Cat part No ENXT P 24L WH CR PC SD (Edge plus series) or its equvalent in Philips, Wipro.
S & F for energy efficient exhaust fan of 230 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. (Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted).
S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories heavy duty ISI marked of size 20 mm dia for LAN, telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by engineer in charge.
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
Excavation in trenches not exc 1.5m wide and not exc 1.5m depth for trenches of pipe line in soft/loose soil complete all as specified and directed by engineer in charge.
Returning, filling in , including spreading, leveling, watering and well ramming in layers not exc 25cms complete all as specified and directed by engineer in charge.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 meter above the starting point complete all as specified and directed by engineer in charge.
S&F tube GI medium grade 15mm dia with all fittings laid in trenches complete all as specified and directed by engineer in charge.
Taking up/down GI tubing and connections 20mm size of pipes including all fittings complete all as specified and directed by engineer in charge.
Taking up/down GI tubing and connections 25mm size of pipes including all fittings complete all as specified and directed by engineer in charge..
S&F tube GI medium grade 20mm dia with all fittings laid in trenches complete all as specified and directed by engineer in charge.
S&F tube GI medium grade 25mm dia with all fittings laid in trenches complete all as specified and directed by engineer in charge.
S&F tube GI medium grade 15mm dia with all fittings laid in trenches complete all as specified and directed by engineer in charge.
S&F gun metal valvs with iron wheel head ,screwed both ends for iron pipe and fixed of size 20 mm complete all as specified and directed by engineer in charge.
badri glass and construction (BID ID -3374899)
sanu enterprise (BID ID -3382303)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .