| 1 | L1₹13.0 LAccepted-AOC 1135 MOHIT APARTMENT ASHIRWAD NAGAR BIDIPETH RING ROAD NAGPUR 440024 | NAGPUR | NAGPUR | MAHARASHTRA | 440024 | ₹13.0 L | L1 | Accepted-AOC Award of Contract, Bidder is L1 |
| 2 | L2₹13.4 L+₹45,220 (3.49%)Rejected-AOC 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | ₹13.4 L+₹45,220 (3.49%) | L2 | Rejected-AOC Bidder is L2 |
| 3 | L3₹13.5 L+₹50,080 (3.86%)Rejected-AOC C O BABA GULKARI FLAT NO C 57 SHANKARRAO PADHYE APARTMENT WARDHA ROAD SAVITRI VIHAR SOMALWADA NAGPUR 440025 MH | NAGPUR | MAHARASHTRA | 440025 | ₹13.5 L+₹50,080 (3.86%) | L3 | Rejected-AOC Bidder is L3 |
| Sl No | Description | Qty | Unit | Sumit Enterprises L1 | LEESHA ELECTRICALS L3 | Manish Electricals L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply of LED Flood light luminaire of 500W having 60 Degree lens angle, housing made from high pressure die cast aluminum (ADC12), toughened glass with IP-66 degree of protection. System efficacy of >110 Lumen/Watt CRI >270 and co-related color temperature (CCT) of 5700K (ANSI). The luminaire should have 4KV surge protection integrated with driver & 10KV SPD, PF20>0.95, and total harmonic distortion of THD≤10%, operating voltage range of 120V-270V should be provided.
The Driver used must be a constant current potted driver (Approved through BIS for electrical safety IS15885) with efficiency o f ≥85% & electrical Class 1. Brand Embossing of on PDC for Traceability Till Life. LM79 from NABL lab (Not Older Than 1 Year) LM80 From the Source Manufacturer for > =9000 Hrs, Luminaire life at 50K Burning Hours. LED makes approved: CREE /OSRAM / LUMILEDS / Nichia only (Similar to Crompton make:CFS-513-500-57-60D- SL-GL-NSG). | 30 | Nos | 25,983 ₹7,79,490 Lowest | 26,985 ₹8,09,550 | 26,857 ₹8,05,710 |
| 2.00 | Supply of LED Flood light luminaire of 500W having 30 Degree lens angle, housing made from high pressure die cast aluminum (ADC12), toughened glass with IP-66 degree of protection. System efficacy of >110 Lumen/Watt CRI >270 and co-related color temperature (CCT) of 5700K (ANSI). The luminaire should have 4KV surge protection integrated with driver & 10KV SPD, PF20>0.95, and total harmonic distortion of THD≤10%, operating voltage range of 120V-270V should be provided.
The Driver used must be a constant current potted driver (Approved through BIS for electrical safety IS15885) with efficiency o f ≥85% & electrical Class 1. Brand Embossing of on PDC for Traceability Till Life. LM79 from NABL lab (Not Older Than 1 Year) LM80 From the Source Manufacturer for > =9000 Hrs, Luminaire life at 50K Burning Hours. LED makes approved: CREE /OSRAM / LUMILEDS / Nichia only (Similar to Crompton make:CFS-513-500-57-30D-SL-GL-NSG) | 20 | Nos | 25,900 ₹5,18,000 Lowest | 26,901 ₹5,38,020 | 26,850 ₹5,37,000 |
| 3.00Note :- All rates to be quoted by bidder should be exclusive of GST | ||||||
Tender Value
₹12.8 L
EMD Value
₹25,700
Closing Date
13 Apr 2026, 11:00 amClosed
Manager (Engg-Elect) MIHAN INDIA LIMITED
MIHAN India Limited (A Govt. of Maharashtra Undertaking) Dr. Babasaheb Ambedkar International Airport 1st Floor, Old Terminal Building , Nagpur - 440005 MH India
Replacement of flood lights for apron area at Dr. Babasaheb Ambedkar International Airport, Nagpur.
2026_MADC_1293263_2
MIL/NGP/ENGG(E)/26-27/NIT01/32
Open Tender
Miscellaneous Services
Item Rate
30 days
Nagpur Airport
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,680
₹25,700
21 Apr 2026
9 Apr 2026
15 Apr 2026
9 Apr 2026
13 Apr 2026
9 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Supply of LED Flood light luminaire of 500W having 60 Degree lens angle, housing made from high pressure die cast aluminum (ADC12), toughened glass with IP-66 degree of protection. System efficacy of >110 Lumen/Watt CRI >270 and co-related color temperature (CCT) of 5700K (ANSI). The luminaire should have 4KV surge protection integrated with driver & 10KV SPD, PF20>0.95, and total harmonic distortion of THD≤10%, operating voltage range of 120V-270V should be provided.
The Driver used must be a constant current potted driver (Approved through BIS for electrical safety IS15885) with efficiency o f ≥85% & electrical Class 1. Brand Embossing of on PDC for Traceability Till Life. LM79 from NABL lab (Not Older Than 1 Year) LM80 From the Source Manufacturer for > =9000 Hrs, Luminaire life at 50K Burning Hours. LED makes approved: CREE /OSRAM / LUMILEDS / Nichia only (Similar to Crompton make:CFS-513-500-57-60D- SL-GL-NSG). | - | Nos | - | - |
| - | Supply of LED Flood light luminaire of 500W having 30 Degree lens angle, housing made from high pressure die cast aluminum (ADC12), toughened glass with IP-66 degree of protection. System efficacy of >110 Lumen/Watt CRI >270 and co-related color temperature (CCT) of 5700K (ANSI). The luminaire should have 4KV surge protection integrated with driver & 10KV SPD, PF20>0.95, and total harmonic distortion of THD≤10%, operating voltage range of 120V-270V should be provided.
The Driver used must be a constant current potted driver (Approved through BIS for electrical safety IS15885) with efficiency o f ≥85% & electrical Class 1. Brand Embossing of on PDC for Traceability Till Life. LM79 from NABL lab (Not Older Than 1 Year) LM80 From the Source Manufacturer for > =9000 Hrs, Luminaire life at 50K Burning Hours. LED makes approved: CREE /OSRAM / LUMILEDS / Nichia only (Similar to Crompton make:CFS-513-500-57-30D-SL-GL-NSG) | - | Nos | - | - |
stage.html
html • 0.04 MB
techsummary_2223342.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.07 MB
TenderDocuments.pdf
Tender Documents • 0.79 MB
BOQ_2223342.xls
BOQ • 0.84 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .