Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 LAccepted-AOC TC 25664 RAJI OPP HOTEL AMRITHA THYCAUD THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | L1 | Accepted-AOC L1 |
Tender Value
₹2.3 L
EMD Value
₹5,678
Closing Date
21 May 2026, 6:00 pmClosed
AEE
AEE,PWD Ele.SDN,Tvm
GENERAL-Govt. taluk Hospital Attingal-SITC of Air conditioning unit in new x-ray unit room in OP Block at Taluk Hospital Attingal. Electrical AC Work.-Electrical AC Work-1
2026_PWD_845846_2
ESDT/ET-291/2025-26
Open Tender
Electrical Works
Percentage
180 days
PWD Electrical Sub Division, TVPM
Please refer tender documents
6 documents required · 6 mandatory
₹555
₹5,678
9 Jul 2026
15 May 2026
23 May 2026
15 May 2026
21 May 2026
15 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1ac conditioning work | |||||
| 1.001 | OD246964/2025-2026:Supplying, installation, testing and commissioning of following nominal cooling capacity and
ISEER value 4.6 or above rated inverter type Hi-wall split air conditioner unit complying to IS:
1391: 1992 (PartI & II) with up-to-date amendments complete with indoor unit ,outdoor unit
(condenser and evaporator coil shall be of copper) etc. and operating on R410 / R32 refrigerent
gas, 230V,50 Hz, single phase AC supply, capable of performing :- a. Cooling b.
Dehumuidifying.c. Air Circulating.d. Filtering including providing wireless remote control unit,
3 metre copper refrigerent piping , wiring, drain pipe for condensate drain water all insulated
with nitrile tubing from indoor unit complete . Make : Hitachi / Daikin/Mitsubishi/ Carrier/
Bluestar:- 1.0TR single phase Inverter split A/C unit | - | each | 51,315.6 | - |
| 1.002 | OD246896/2025-2026:Supplying, installation, testing and commissioning of following nominal cooling capacity and
ISEER value 4.6 or above rated inverter type Hi-wall split air conditioner unit complying to IS:
1391: 1992 (PartI & II) with up-to-date amendments complete wit indoor unit ,outdoor unit
(condenser and evaporator coil shall be of copper) etc. and operating on R410 / R32 refrigerent
gas, 230V,50 Hz, single phase AC supply, capable of performing :- a. Cooling b.
Dehumuidifying.c. Air Circulating.d. Filtering including providing wireless remote control unit,
3 metre copper refrigerent piping , wiring, drain pipe for condensate drain water all insulated
with nitrile tubing from indoor unit complete . Make : Hitachi / Daikin/Mitsubishi/ Carrier/
Bluestar:- 2.0TR single phase Inverter split A/C unit | - | each | 69,581.11 | - |
| 1.003 | OD246965/2025-2026:Supply and providing the following size soft drawn copper pipe for extending the pipe between
out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm
thick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 1/2 inch (12.7 mm) 22 gauge | - | metre | 988.62 | - |
| 1.004 | OD246541/2025-2026:Supply and providing following size soft drawn Copper pipe for extending pipe between out door and
indoor units including insulating pipe using rubberized foam sleeve 10mm thick, brazing, leak testing
etc.3/8"(9.52mm) and 5/8"(15.8mm) 22 gauge . | - | each | 1,242.94 | - |
| 1.005 | OD234818/2025-2026:Supply and installation for the Outdoor unit stand of Single phase 1 TR/1.5 TR/2TR Wall mounting split A/C unit. | - | each | 1,220.15 | - |
| 1.006 | OD234825/2025-2026:Supply and Fixing of 3 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 250V (make V-GUARD or its equivalent | - | each | 3,077.98 | - |
| 1.007 | OD234824/2025-2026:Supply and Fixing of 5 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 250V (make V-GUARD or its equivalent | - | each | 3,658.15 | - |
| 1.008 | OD234873/2025-2026:Supply and fixing 25mm dia PVC drain pipe and along with all required accessories in suface/recess including cutting the wall and making good the damages etc as required | - | metre | 105.7 | - |
| 1.009 | 90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm | - | metre | 113.25 | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1438226.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1438226.xls
BOQ • 0.32 MB
nit.pdf
Tender Documents • 0.02 MB
mom.pdf
Tender Documents • 0.19 MB
sbd.pdf
Tender Documents • 1.87 MB
sc.pdf
Tender Documents • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .