Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.8 L+₹1.1 L (7.27%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹17.1 L+₹1.5 L (9.29%)Rejected-Finance H NO 1300 PUSHP VIHAR COLONY GUPT GANGA ROAD KANGRA 176001 | KANGRA | KANGRA | HIMACHAL PRADESH | 176001 | L3 | Rejected-Finance L3 |
Tender Value
₹15.0 L
EMD Value
₹30,000
Closing Date
8 Sept 2022, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Elect. Division HPPWD Palampur
C/O Art Gallery and Museum at Dharamshala, Distt. Kangra, HP (SH- Providing E.I. in Ground Floor therein)
2022_PWD_64253_2
Elect. Division HPPWD Palampur
Open Tender
Electrical Works
Item Rate
365 days
Dharamshala in Distt. Kangra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
₹30,000
6 Oct 2024
30 Aug 2022
8 Sept 2022
30 Aug 2022
8 Sept 2022
30 Aug 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Make: KEI/Plaza/Anchor/ Anchor (Roma Plus)/Schneider (Livia)/ Legrand (Myrius) /L&T(Entice).
Group C.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. Make: KEI/Plaza/Anchor/ SCI
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. Make: KEI/Plaza/Anchor/SCI
3 x 2.5 sq. mm
Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. Make: Anchor (Roma Plus)/Schneider (Livia)/ Legrand (Myrius)/L&T(Entice).
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. Make: Anchor (Roma Plus)/Schneider (Livia)/ Legrand (Myrius)/L&T(Entice).
Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole 6 Amp (Make:- Anchor/ Schneider/ Legrand/L&T)
Single pole 16 Amp (Make:- Anchor/ Schneider/ Legrand/L&T)
Single pole 25 Amp (Make:- Anchor/ Schneider/ Legrand/L&T)
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 Amps. (Make:- Anchor/ Schneider/ Legrand/L&T)
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 Amps. (Make:- Anchor/ Schneider/ Legrand/L&T)
Supplying and fixing following way,Triple pole and neutral, sheet steel, Horizontal PPI, 415 volts, on surface/ recess, complete with DB`s,Complete with colour-Coded wire set,100 A insulation busbars,Neutral Bars with sroud`s,Earth bar`s Cement Spill protector,Cable ties,Blanking plates and circuit identification label with provision for FP MCB/Isolator/RCCB/RCBO as incomer, DP RCCB/RCBO as Sub incomer and SP MCB as outgoing etc. as required. (But without MCCB,MCB/RCCB/Isolator).
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as require (Make:- KEI/ Plaza/Polycab)
Armoured cable120 sq. mm (3.5 core)
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-(Make:- KEI/ Plaza/Havells)
Armoured cable 35 sq. mm (3.5 core)
Armoured cable 120sq. mm (3.5 core)
Providing, Installation, testing and commissioning of wall fan of following size by means of suitable rag-bolt/ nuts, connections, testing and commissioning etc. as required complete in all respects as required.
Wall Fan, 400 mm sweep (Makes:- Bajaj Esteem 400)/Usha (Model:Air Flo)/ Anchor (Model: Fancy)/Crompton (Model:High Flo).
Providing and installation exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required.
Exhaust Fan, Light duty, (Domestic) 300 mm sweep (Make: Usha, Model: Aeroclean LD)/Bajaj (Model: Freshee)/Anchor (Model: Anmol)/Crompton(Model: Drift air Plus .
Providing and installation of Back Light (Non slim model)15 W +/- 1 W LED Square Surface Mounted Downlighter with minimum system lumen efficacy of ≥100 lm/W with and P.F.>0.95 with THD<10% ,CCT 6000 K,CRI 80.The LED with Useful life of 50000 Hrs at L70 with 5- years warranty.The Input voltage range shall be 150V to 270V , 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects.
LED Down Light 15 watt, (Make: Wipro, Cat no LD06-171XXX 57SM)/ Philips/Trilux.
Providing and fixing LED Multiple Zoom Light of 3x15 watt (3000K/4000K) and it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion <10% and efficacy > 100 Lumens per watt, CRI rating > 80 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as required.
LED Multiple Zoom Light of 3x15 watt Make: Jaquar (Cat No LZOMMLR315XN/XW) /Philips
Providing and fixing LED Multiple Zoom Light of 3x35 watt (3000K/4000K) and it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion <10% and efficacy > 100 Lumens per watt, CRI rating > 80 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as required.
LED Multiple Zoom Light of 3x35 watt (As per cat/price list Jaquar (Cat No LZOMMLR335XN/XW)/Philips
Providing and installation of LED FLOOD LIGHT 120 WATT lumanire equipped with heat sink, energy efficient electronic driver, high surge protection 4kv, optics clear glass complete with all accessories, including connections testing & commissioning etc. as required. Makes: Bajaj/Wipro/Philips.
LED Flood light 120 watt
Supplying and erection of L.T. Panel board of suitable size cubical, weather, dust and vermin proof fabricated outof CRCA sheet steel suitable size thickness complete MCCB panel board should be manufactured and supplied by ISO 9001 certified OEM. The busbar system should be duly type tested at NABL lab for short time with stand current of 1 second, it should be suitable for wall or floor mounting with double door option, panel board enclosure should be robust construction and corrosion resistance, powder coated with seven tank process with locking arrangement, fixed on suitable size foundation 60 cm above the ground level by providing angle iron of 50x50x6 mm welded on all four corners embedded in PCC 1:2:4 using 20mm graded stone aggregate up to 30 cm including electrical connections with lugs and glands complete with installation, testing and commissioning etc. including the cost of copper alloy bus bar, digital type Ammeter,Voltmeter, modules and three phase indicating lamps as required complete in all respects. The panel should be approved/tested from the CPRI lab and should be confirmed to IS:64139. (Make: EVA/ Power System & Controls/ DV Electromatic Pvt. Ltd./ or equivalent).
Main LT Panel
Supply, fabricating, installing, testing, commissioning and electrically connected Factory (CPRI approved) made LT panel board of approved size as recommended by IS & CPRI norms, indoor type, floor mounted 1100 Volts, made out of CRCA sheet 2.0 mm thick for load bearing and 1.6 mm thick for non- load bearing, fully compartmentalised, with IP-54 (certificate not older than 2 years) protection with 5mm thick channel for frame, for 415 volts, 3 phase, 4 wire AC supply, complete all as specified including provision of following accessory/ components housed in it :-
300Amp rated Aluminium bus bar with colour code TPN mounted on epoxy insulators - 01 set (set of 04 bus bars)
Digital Multifunction meter 0-250Amp with suitable CTs - 01 set (Make: L&T)
LED indicating lamp (set of three) - 01 set
Internal wiring with 1100 volt grade unsheathed PVC insulated copper conductor of suitable size cable as per colour coding or suitable size of bus bar for all connections with suitable lugs as required and as specified.
Earthing terminals and cable glands.
Danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door.
Switchgear:-
Main Incomer:-
Manual Changeover250 Amps, 4 Pole
MCCB 250 Amps, 4 pole, Thermal Megnetic release, rupture capacity 35 KA - 01 No. (With spreader Link) (Make: L&T)
SPD (Surge protection device) Type 1+2 , 3P+N, 15 KA - 01 No. (Make: Phoenix)
Outgoing:-
MCCB 100 Amps, 4 pole 25 KA, Adjustable thermal setting - 02 Nos (Make: L&T)
MCCB 63 Amps, 4 pole, 10 KA, Adjustable thermal setting - 03 No. (For Yard Light) (Make: L&T)
pankaj saini
Deepak Sood
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .