Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L₹25.5 LAccepted-AOC | L | Accepted-AOC L1 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
16 Dec 2022, 5:00 pmClosed
Divisional Forest Officer
Divisional Forest Officer Nilambur South Division Wildlife Warden Karimpuzha Wildlife Sanctuary Nilambur-679329
Supplying, Installing, Testing and commissioning of Hanging Solar Fencing 5 kms from Pattakkarimba to Kavala in Kalikavu Range in Nilambur South Division during 2022-23
2022_FD_538132_1
D-4051/22/SN
Open Tender
Solar Battery Chargers
Item Wise
90 days
Pattakarimba Kavala Chakkikuzhi Kalikavu
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,500
Yes
₹50,000
Yes
11 Jan 2023
9 Dec 2022
20 Dec 2022
9 Dec 2022
16 Dec 2022
9 Dec 2022
Amount
Hanging Fence
od120234/2022_2023 : ENERGIZER FOR HANGING FENCE With the following specifications 24V ENERGIZER, must be from a reputed company, must confirm to IEC 603352-76 and all National and International standards of safety.Switch to high, medium and low power settings.Solar panel option to recharge 12 volt battery.Full and reduced power output terminals can be operated at once on different fences independently.Should possess the following output characters - Peak o/p voltage not more than 10 KV on 50 K load. - O/p energy 3.5 J minimum - Pulse duration 1.01-3.0 m. sec - Pulse interval 1.1-1.4 sec - Peak current 7.0-8.0 A-High - RMS current 2.4-2.8A-High- Charge 1.0-1.4 m C-High 3 years warranty against manufacturing defects
od120235/2022_2023 : SOLAR MODULE FOR HANGING FENCE<br> Monocrystalline with the following Specification 200 watts,12 volts rating with minimum 10 years warranty against manufacturing defects. <br>Solar charge controller to regulate the charging of the battery.
od120236/2022_2023 : MODULE STAND WITH BOX With MS thickness tilted to 13-15 degrees
od120237/2022_2023 : BATTERY<br>Must have 12 Volts, 120 AH maintenance free (Exide or Base or okaya)<br>battery with at least 3 years replacement warranty.
od120238/2022_2023 : LIGHTNING DIVERTER<br>Must be capable of diverting stray lightening.The diverter assembly must be adjustable for spark gaps.; Adequate earthing to be provided
od120239/2022_2023 : EARTHING SYSTEMMust contain earth mixture capable of retaining moisture and 8 mm dia stainless steel rod non rusting quality of 4 feet long
od120240/2022_2023 : SUPER STRAIN INSULATER Must be of polypropylene material and should withstand of 16 KV.
od120241/2022_2023 : WARNING SIGNSPoly ethylene plastic with statutory colors and signs
od120242/2022_2023 : LEAD OUT CABLEMust be double insulated withstanding 15 KV voltage and Inner core wire must be GI
od120243/2022_2023 : T-SHAPED GI SQUARE TUBE17 Feet length, 14 gauge, class B pipe of 2 inches inner diameter, non rusting quality with ISI standards. (above the ground 14 feet and top pipe 3 feet)
od120244/2022_2023 : STAINLESS STEEL WIRE 1.51.5mm 304 grade, non rusting quality for main line.
od120245/2022_2023 : STAINLESS STEEL WIRE 1.21.2mm, 304 grade, non rusting quality for earthing line and middle line (for Horizontal Line at 4 feet above the ground)
od120246/2022_2023 : GI WIRE ROPE1.5mm and non rusting quality for hanging line.
od120247/2022_2023 : BULLETS (Connectors)Connectors of copper material coated with stainless steel having an inner core hole size of 2.5 mm diameter, 2 cm length.
od120248/2022_2023 : BOTTOM FIXTUREBOTTOM FIXTURE that includes A. GI SQUARE TUBE of 32 inches length, 2.5 inches inner diameter, 14 gauge, non rusting material with ISI standards. B. BUSH- UV stabilized, heat resistant, non electrical conductible poly propylene material for fixing inside the GI square tube.
od120249/2022_2023 : VEGETATION CLEARING in fencing area and pruning the vegetation and tree branches up to height of 15 feet if any.
od120250/2022_2023 : ERRECTION OF HANGING FENCE AS PER THE DIRECTION OF OFFICER IN CHARGE
od120251/2022_2023 : DIGITAL VOLT METER
od120252/2022_2023 : TOOL KIT
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.4 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)
Bidder Name
V P Shoukathali
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .