| 1 | L1₹40.5 LAccepted-AOC 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹41.4 L+₹477 (0.01%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹42.3 L+₹92,645 (2.24%)Rejected-Finance 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹44.6 L+₹3.2 L (7.73%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹44.9 L+₹3.5 L (8.43%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
22 Feb 2021, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF AMB-57/2020-21 MANNING AND OPERATION OF ESC POWER HOUSE, RACE COURSE POWER HOUSE, OPERATION OF DG SET AT NGCCM, 702SU, DARIN-II INCLUDING ALLIED WORKS AT AF STATION AMBALA UNDER GE (AF) AMBALA
2021_MES_415881_1
GE AF/AMB-57/2020-21
Open Tender
Civil Works
Item Rate
335 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE AF AMBALA
₹99,000
Yes
16 Mar 2021
25 Jan 2021
24 Feb 2021
25 Jan 2021
22 Feb 2021
9 Feb 2021
1 Feb 2021 - 5 Feb 2021
Amount
PART-I (M&O WORKS)
Manning & Operation of switchgear / breaker including attending external electric complaints of HT/LT electrification including street lights, OH lines, etc. by providing 01 (one) skilled qualified electrician, in 03 (three) shifts of 8hours each (round the clock 24hrsx3 shifts = 3 electricians) on all days including Sundays and holidays for technical area at ESC power house complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge
Manning & Operation of switchgear / breaker including attending external electric complaints of HT/LT electrification including street lights, OH lines, etc. by providing 01 (one) skilled qualified electrician, in 03 (three) shifts of 8hours each (round the clock 24hrsx3 shifts = 3 electricians) on all days including Sundays and holidays at Race Course power house complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge
Manning & Operation of substation with 1No. DG set 250kVA including operation of LT panel, AMF panel, attending to minor faults/repairs, complaints, etc. by providing 01 (one) skilled FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays for NGCCM complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation of substation with 2Nos. DG sets 125kVA (make Cummins), 1No. DG set 75kVA (make Kirloskar) and 1No. DG set 62.5kVA (make Greaves Cotton) including operation of LT panels, AMF panels, attending to minor faults/repairs, complaints, etc. by providing 01 (one) skilled FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays for 702SU complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation of substation with 1No. DG set 62.5kVA (make Kirloskar), 1No. DG set 250kVA (make Ashoke Leyland) at Darin-II and 1No. DG set 62.5kVA (make Mahindra) at SES bay including operation of LT panels, AMF panels, attending to minor faults/repairs, complaints, etc. by providing 01 (one) skilled FGM, in 02 (two) shifts of 8hours each (0800 to 1600hrs & 1600hrs to 2400hrs) = 2 FGMs on all days including Sundays and holidays complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge
Notes for serial item Nos. 1.00 to 6.00: (i) The timings for each shift shall be as decided by the Engineer-in-charge. No claim whatsoever on this aspect is admissible (ii) The minimum wages as derived by the Department including all statutory provision such as EPF, ESIC, Bonus, GST, etc. as applicable except the Contractor's profit for skilled person works out to Rs. 765/-per person per shift (iii) Bidder has to upload an signed undertaking in firm's letter head confirming that he has not quoted his rates lower than the derived minimum rates of the Department. Bids not accompanied with such undertaking shall not qualify for opening of the price bids. As applicable, his tender will be treated as 'NON BONAFIDE' if found at any stage and will not be considered for acceptance. In such case, the lowest tender shall be determined by the lowest amount amongst valid / bonafide bids only (iv) However increased minimum fair wages as notified time to time by the Government of India / State Government / Labour Regulations whichever is higher including all statutory provisions such as EPF, ESI, Bonus, taxes, etc. as applicable, irrespective of derived minimum wages as above
Notes for serial item Nos. 1.00 to 6.00 contd: (v) Increased wages including all other benefits in compliance of statutory provisions shall be paid to the workers by the Contractor. No other claim whatsoever shall be admissible on this account and the bidders shall note this aspect and quote their rates accordingly. It must be noted that in compliance of all statutory provisions, the increase shall be passed over to the workers (vi) Rates quoted by the bidder shall be deemed to be inclusive of any extra manpower required (if any) for relieving, replacement, etc. and all stipulations as per tender documents (vii) The operator placed shall be responsible to attend complaints concerned to the location/s as directed (viii) Conveyance/vehicle for moving around of the staff employed and or any T&P required and detailed specifics as per particular specifications shall be provided by the Contractor. (ix) A penalty of Rs. 500/- per complaint shall be imposed on non-attending of such complaints as directed. Such penalties shall be recovered immediately from corrosponding RARs/FB of the Contractor.
PART-II (REPAIR & OTHER WORKS)
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying/fixing GI tubing, 80mm bore, light grade including all fittings as in cable protection under road, in trences, on pole/wall, etc. and in similar position complete all as specified and as directed
Supplying, laying / fixing, testing and commissioning of electric cable, 3.5 core 240sqmm, 1100V grade aluminium conductor XLPE insulated, armoured cables conforming to IS-7098 (Part-I)-1988, stranded, XLPE insulation, PVC tape inner sheath laid in trenches, passing through ducts, etc. fixed on poles, etc. including taking up old / unserviceable cable and brick covers and disposing off complete all as specified and as directed of the following sizes: Note: Excavation/earthwork, bricks, sand cushoing and GI pipe shall be measured and paid separately under respective items herein
M&L for servicing & calibrating damaged / faulty (overload current/ earth fault, etc.) VCBs in sub-stations, of make Crompton Greaves/ABB, at sites on any locations, immediately on situation of any fault, and restoring funcionality with and including replacing of minor parts viz. HRC fuses, indicator lamps, control wiring, etc. oiling, greasing, cleaning with blower from inner and outer sides, decarburizing of the links with CRC spray, etc. checking serviceability complete all as specified and as directed Notes: (i) The job shall be carried out at a periodicity of 6months from date of commencement or at requirements and or as directed by the Engineer-in-charge (ii) Work of overhauling, servicing, testing, etc. shall be got done through Engineer/ Technician of manufacturer (iii) Overhauling & servicing shall be done to the tune of complete serviceability / functionality of the VCB (iv) All costs of technician/Engineer on hire, minor spares, any sort of conveyance of man and material, testing & calibrating equipment, etc. shall be deemed to be included in the quoted rate (v) Servicing reports shall be sumitted by the Contractor to the Engineer-in-charge and shall made part of RAR/FB for claiming any such payments
M&L for danger notice plates, for LT of size 25x20cm, made of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts including taking down old / damaged notice plates and disposing off complete all as specified and as directed
Supply, install, testing and commissioning 66kV class station heavy duty metal oxide gapless type LA for use with effective ground natural system with insulating base including surge monitors for 66kV with all accessories meeting and catering the requirement detailed as under complete all as specified and as directed (a) Nominal system voltage- 66kV (rms) (b) Highest system voltage - 72.5kV (rms) (c) MCOV 52kV (d) Nominal discharge current- 10KAP (e) Line discharge- Class 3 (f) High current discharge- 100KAP (g) Maximum residual voltage- 165KVP at 01KAP
S&F in repairs epoxy resin cast CT dual core of ratio as per existing accuracy class 0.55, burden 100/50/5VA for 11kV complete all as specified and as directed
S&F in repairs epoxy resin cast CT dual core of ratio as per existing accuracy class 0.55, burden 50/25/5VA for 11kV complete all as specified and as directed
S&F in repairs battery charger 24V 50Hz charging range 6 to 24volt with trickle / boost charging mode with ammeter and voltmeter complete all as specified and as directed
Supply only silica gel in 5/10kg sealed packets complete all as specified
M&L for cable jointing kit for 11kV earthed grade cable for straight through heat shrink type joint indoor / outdoor with jointing material and accessories suitable for 3 core, 90 to 120mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 11kV earthed grade cable for straight through heat shrink type joint indoor / outdoor with jointing material and accessories suitable for 3 core, 150 to 185mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 11kV earthed grade cable for straight through heat shrink type joint indoor / outdoor with jointing material and accessories suitable for 3 core, 240 to 300mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, indoor termination type, for 11kV earthed grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core, 90 to 120mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, indoor termination type, for 11kV earthed grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core, 150 to 185mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, indoor termination type, for 11kV earthed grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core, 240 to 300mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, outdoor termination type, for 11kV earthed grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core, 90 to 120mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, outdoor termination type, for 11kV earthed grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core, 185 to 300mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
S&F in repairs aluminium thimbles complete all as specified and as directed of the following sizes:
M&L for base assembly in replacemetn of suitable size as per existing size and make of VCB after disconnecting, taking out VCB and reinstating, reconnecting and testing on installation complete all as specified and as directed
Supply, install, testing and commissioning battery bank 110V /100AH, as per relevant IS complete all as specified and as directed with and including the following: (i) Battery dry type 2Volt 100AH- 55Nos (ii) M6 x 25mm Hex headbolt SS 304- Passi- Kun 80- 115Nos (iii) M6 F washer SS 304 (6.5x19.0x3mm)- P- 115Nos (iv) M6 spring washer SS 304 (6.1x11.8x1mm) - 115Nos (v) Bottom support 10/120/200/240Ah- WG - 02Nos (vi) 12 CL- IP 6005/7005 PVC front cover - RT- 05Nos (vii) 110x20x2mm ICC connector (H) - 35Nos (viii) 73x20x2mm ( ICC (V) connector - 14Nos (ix) 118x20x2mm- ICC connector - 11 PL(V) - 04Nos (x) Serial No. 1- 56 sticker - 01No (xi) M8x 25 Hex bolts GI - 14Nos
Item No. 44 contd.. (xii) M 10 flat washer GI (11.0x22x2.5mm) - 28Nos (xiii) M8 Hex nuts GI (13.0x6.5mm) - 14Nos (xiv) I&C manual for stand by -Ip series -01No (xv) System indentification lable for 100Ah - 03Nos (xvi) Petroleum jelly - 20G - 0.040kg (xvii) Front cover fixing leg for new type FC - 22Nos (xviii) -VE UPTPA12 CITRAY05PL- 25x3mm -MS-WG- 01No (xix) +VE DOWNTPA 12CITRAY05PL-25x3mm-MS-WG- 01No (xx) 135x20x2mm IMC/ECC connector - 02Nos (xxi) Stack top plate -PC- New (12x30 Slt) - 01No (xxii) 25sqmm 300mm elaston C connector (6.4mm) - 0 No
Notes for item No. 44: (a) Batteries shall be located inside trays of MS HRCA sheet, painted with RAL 7040 (window grey colour), (b) Trays shall be mounted on Penguin legs (c) All cell connectors shall be made of lead coated copper busbars (d) All connectors shall be designed for 27A current rating (e) All connectors shall be designed for 3hrs discharge rating
S&F gang operated air break switch from two pole / four pole structure, triple pole, mechanically operated, mounted on suitable insulators and steel frame with operating mechanism worked from ground level using heavy duty GI pipe, outdoor type, HT 11kV, with fixed contacts of phosphorous and bronze and a set of dropout HT fuse assembly, fuse carrier fitting, 12 insulator type mounted on MS channel operating rod with pad lock arrangement conforming to relevant IS, including dismantling, taking down and disposing off old / unserviceable air-break switch complete all as specified and as directed of the following current rating:
S&F in repairs IDMT relay with numerical relay for VCB tripping system for E/F (10% to 400% in step of 1%), O/C (1% to 20% in step of 1%), having ability to record 20 to 30 fault records and 200 to 250 events records with modbus protocol for communication operated on 24V DC/110V AC all as per per existing complete all as specified and as directed Note: Existing relays are IDMT electromagnetic type hence any modification in the wiring and panel sheet enclosure shall be done to get system operational. Cost for all such aspects shall be deemed to be included in the quoted rate
Supplying, designing, fabrication and fixing MS trolley suitable for VCB /ACB, fabricated out of MS angle iron pipe and MS sheet to required size as per site having wheels on all four legs including all welding, cutting, bending, locking arrangements, nuts, bolts, washers, etc. taking out and disposing off old / unserviceable trolley complete all as specified and as directed Note: (i) Design and fabrication data shall be in accordance to existing trolley (ii) VCB / ACB shall be pulled out, placed in new trolley and shall be replaced in position including all connecting up (iii) All lifting, loading, unloading, etc. required to replace old trolley shall be deemed to be included in the quoted rate
S&F feeder pillar box / panel of size 1200x1200x1200mm, outdoor type, double door, front & back openable, suitable of 3 phase 415V, fabricated out of 3.15mm thick MS sheet with suitable size of MC & HT 11kV aluminium busbar, fitted with and including HT 11kV base type insulators, provisioning of suitable locking arrangments, duly placed over and including angle iron (50x50x6mm) frame stand grouted in base foundation duly embedded in ground having height 500mm above ground in PCC 1:2:4 type C1 with 20mm graded stone aggregate alongwith all necesary cable connection with thimbles nuts, bolts, lugs, cable glands, etc. painting all over with 2 coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer, including suitable danger notice plates on all four sides and dismantling old unserviceable feeder box / panel and disposing off complete all as specified and as directed
S&F in repairs on load change over switch 415V 250Amp 4 Pole with front handle operation as per exising make and size complete all as specified and as directed
S&F in repairs on load change over switch 415V 400Amp 4 Pole with front handle operation as per exising make and size complete all as specified and as directed
S&F in repairs off load change over switch 415V 160Amp 4 Pole with side handle operation in sheet metal enclosure as per exising make and size complete all as specified and as directed
S&F in repairs off load change over switch 415V 250Amp 4 Pole with side handle operation in sheet metal enclosure as per exising make and size complete all as specified and as directed
S&F in repairs off load change over switch 415V 400Amp 4 Pole with side handle operation in sheet metal enclosure as per exising make and size complete all as specified and as directed
Supplying, fixing, connecting, testing and commissioning MCCB 125A, FP, 16kA, 415V, 50Hz rating with adjustable thermal and magnetic setting complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 200A, FP, 36kA, 415V, 50Hz rating with adjustable thermal and magnetic setting complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 250A, FP, 36kA, 415V, 50Hz rating with adjustable thermal and magnetic setting complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 315A, FP, 36kA, 415V, 50Hz rating with adjustable thermal and magnetic setting complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 400A, FP, 36kA, 415V, 50Hz rating with adjustable thermal and magnetic setting complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 630A, FP, 36kA, 415V, 50Hz rating with adjustable thermal and magnetic setting complete all as specified and directed
S&F in repairs panel mounting voltmeter 3phase 0-500V digital type in 96x96sqmm display, flush mounted, class1.0 complete all as specified and as dirtected
S&F in repairs panel mounting ampere meter 3phase 400A rating, digital type in 96x96sqmm display, flush mounted, class1.0 complete all as specified and as dirtected
M&L for earthing using GI earthing strip 32x6mm with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI strip of size 32x6mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed
Notes for serial item No. 67: (i) The cost of copper / GI earth continuity wire with GI pipe 50mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
Raman Electric Trading Co
NAVREET CONSTRUCTION
m/s parmod kamar
Baliyan Electrical Works
Bal Singh and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .