Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 CrAccepted-AOC | ₹4.1 Cr | L1 | Accepted-AOC 41160145.60 |
Tender Value
₹3.9 Cr
EMD Value
₹4.7 L
Closing Date
10 Feb 2020, 6:00 pmClosed
CE 31 Zone
CE 31 Zone
PROVN OF OTM ACCN FOR CERTAIN UNITS WITH ALLIED INFRA AT RAMPUR (PHASE-I OF TWO PHASES)
2019_MES_290186_1
PROVN OF OTM ACCN FOR CERTAIN UNITS WITH ALLIED I
Open Tender
Civil Works
Lump-sum
700 days
Baramula
As per tender documents
6 documents required · 6 mandatory
₹2,000
GE 969 EWS
₹4.7 L
Yes
18 May 2020
16 Oct 2019
13 Feb 2020
16 Oct 2019
10 Feb 2020
3 Dec 2019
16 Oct 2019 - 28 Oct 2019
Amount
Note: (i) Please refer Schedule 'A' Notes given on serial page No. 22 to28 of tender documents. (ii) Item from Srl No. 3 to 8 of this document shall be Part-XIII (Miscellaneous items) of BOQ (iii) Unless otherwise specified, earth work and excavation shall be measured and paid separately forSch 'A' Part III to VIII and X of BOQ (iv) This schedule 'A' Part-XIII (Miscellaneous items) is not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule 'A' Part-I brought forward from serial page No. 29(R )
Lump sum price worked out by the contractor for INTERNAL ELECTRIC SUPPLY WORKS as listed in Schedule 'A' Part-II brought forward from serial page No. 31
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 33(R )
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS listed in Schedule 'A' Part-IV brought forward from serial page No. 35
Lump sum price worked out by the contractor for ROAD, PATH & CULVERT WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 37( R)
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule 'A' Part-VI brought forward from serial page No. 39( R)
Lump sum price worked out by the contractor for PROTECTIVE WORKSas listed in Schedule 'A' Part-VII brought forward from serial page No. 41
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-VIII brought forward from serial page No. 44 (R )
Lump sum price worked out by the contractor for SITE CLEARANCE & EARTHWORKS as listed in Schedule 'A' Part-IX brought forward from serial page No. 45(R )
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-X brought forward from serial page No. 46
Lump sum price worked out by the contractor for DEMOLITION/DISMANTLING WORKS as listed in Schedule 'A' Part-XI brought forward from serial page No. 47
INTERNAL ELECTRIFICATION WORKS
Supply and fix Lamp holder bracket type with LED lamp 7W, PVC/Polycarbonate type with skirt cap suitable for batten fitting, complete all as specified and directed.
Supply and fix ENDURA PEARL New generation energy saving and environment friendly long life LED street light fitting 20W LED 5700 K in and including LED lamps made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP 65 protection and impact resistance of IK07 and testing on completion including GI wall mounting bracket 32 mm dia 1.2Mtr long incl 120 degree bend with 02 No FI clamps 25x3mm size with necessary nut bolts etc complete all as specified and directed. Make: Havells Cat part No ENDURAOEARLLSL20WLED757SASYTOPC/Equivalent in Philips, CG.
Supply and fix ceiling fan of size 1200 MM Having (BEE 5 Star rating) sweep complete and connecting up including provision of with copper standard conductors cables from ceiling rose/connector to fan complete all as specified and directed. Make: Bajaj/Havells/CG
Supply and fix mirror light fitting 1x10 watt with LED Lamp etc, Completed with all accessories and including connecting up with 3 core twisted flexible copper conductor cable with suitable size of 230 50 HZ complete all as specified and directed.
Supply and fix exhaust fan ventilining type of heav duty AC single phase 230V/240V 50 Hz of size, 300mm sweep 1400 rpm and complete with louvers, shutter and connecting up ceiling rose to connector bloack of fan including making of holes and grouting of nuts and bolts complete all as specified and directed. Make: Havells/Crompton/Khaitan
Supply and fix Wall fan of size 400 MM sweep and connecting up ceiling rose to connector block of fan including grouting of nut & bolts completed all as sepcified and directed.
Supply and fix Endura Linear Neo Surface and wall mounted LED batten, 20 W LED tube (4 ft) having minimum 2000 lumens with epoxy coated white extruded aluminium channel housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver, high efficiency long life LED chips with lumen efficacy of 125 lumen/watt with a viewing angle of 120 degree to ensure better lumen output, milky white special polycarbonate diffuser for glare free efficient light distribution elegantly designed white coloured ABS end caps, integral electronic (SMPS based constant current supply) with output short circuit protection, surge protection as per IS: 15885 Part-2 (sec 13), voltage range 140-270V, colour temperature of 5700K>100Im/w system luminous efficiency and power factor>0.95 and incl 20 w LED tube complete with all eccessories as sepcified and directed. Make: Havells Model No. LHCDEFXD5L8R020HFXCEPITNNW020 or equivelent in Bajaj/CG.
Sheet metal enclosure V TPN factory made, double door for DBs 440 Volts, triple pole and neutral 4 way with 200 Amps rated bus bar, complete all as specified and directed.
Supply and Fix MCB 40 Amps 230 Volts 50 Hz SPN 15 KA with fixed thermal magnetic releasing system incl making connection with existing cable with connection materials like copper strips lugs nuts bots with sheet metal enclosure suitable for one single MCCB complete all as specified as directed.
Supply and Fix MCB 63 Amps 230 Volts 50 Hz SPN 15 KA with fixed thermal magnetic releasing system incl making connection with existing cable with connection materials like copper strips lugs nuts bots with sheet metal enclosure suitable for one single MCCB complete all as specified as directed.
Supply and Fix MCB SP 240V, 50 Hz, 10 KA, B curve of rating (0.5-6 Amp) complete all as specified as directed.
Supply and Fix MCB SP 240V, 50 Hz, 10 KA, B curve of rating 16 Amp complete all as specified as directed.
Supply and fixing sub main wiring with two runs of single core FRLS PVC insulated stranded copper conductor 4 Sqmm and one run of 4 Sqmm for earth continuous earth wire inlcuidng suitable PVC conduit medium grade ISI marked all as specified and directed. Note : Two runs of PVC cable 4 sqmm & one runs of earth wire 4 sqmm will be considered as one unit.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x6 mm thick burried directly in gound (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanised iron earth lead 4mm dia by means of bolt, nuts check nuts and washers of galvanised iron and 4 mm dia GI earth wire protected by provn of GI medium grade pipe 15mm bore upto 7.5mtr including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (Weight not less than 4kg/Sqm) and frame of angle iron 25x 25x3mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of Bronze/Gun metal with fixing arrangement, funnel, wire mesh and excavation/earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No 3 of SSR -2010 Part -I and connecting to earth test point all as specified or indicated including testing on completion, complete all as specified and directed. Note : The quoted rate of earthing shall be deemed to include cost of 7.5 m long galvanised wire 4 mm dia and protection pipe 15 mm bore medium grade GI light grade 20 mm bore watering pipe. Any variation in length shall be adjusted through deviation order based on SSR rates adjusted with quoted rates.
INTERNAL WATER SUPPLY WORKS
S&F urinal spreader of PRMR any colour for figure with 15mm dia pipe (minimum weight 60 gms) complete all as specified & directed.
S&F angle valve cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for 15mm bore iron pipe or for unions and fixed complete all as specified and directed.
SEWAGE DISPOSAL WORKS
Material and Labour for RCC septic tank for 100 user with upflow filter designed to carry sewage and sullage water, incld excavation and earth work in any type of soil, PCC 1:4:8 below foundation, RCC M-30 design Mix in walls, Base Slab, Baffle walls and roof slab including beams etc with vent shaft, manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter, (Ref TD ND CESZ/TD-01/2015, Sheet 1/3 to 3/3) complete all as specified and directed.
Material and Labour for Soakage wells incld excavation and earth work, in any type of soil, foundation in PCC 1:3:6 wall of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia x3.0 M effective depth (Ref TD ND CESZ/TD-01/2015, Sheet 1/3 to 3/3 ) complete all as specified.
ROAD, PATH & CULVERT WORKS
Road marking with reflective thermoplastic screed 2.5mm thick using thermoplastic road marking paint of approved brand(white or yellow) including admixture layer of glass beads confirming to BS-6088 and most specification by using automatic mechanical road marking machine including cleaning of all dirt, scales, oil, grease and foreign material etc; complete all as directed. Makes : Asian Paints/Shivalik Prismo India Pvt ltd/ Reliance
Uni/dual/tri-directional acrylic plastic reflectors cat eye of ABS material having size 100mmx100mmx200mm with celluler lence design alloy to continue functioning even after impact/damage in white/red/yellow fixed with special hot melt bitumen adhesive to road and including taking down of old unservisible plastic reflector cat eye complete all as specified and as directed.
Red morrum filling in road side berms including watering and consolidation complete all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY WORKS
M & L for sand cushioning with a layer of fine sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified. Notes: (i) Excavation and earth work to be measured and paid for separately. (ii) Measurement shall be taken only after punning down sand cushioning.
Material & labour earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.15mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth electrode GI strip 32 x 6 mm dia connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth wire connected to main switch board and protected by galvanized iron light grade 40mm bore and GI pipe 20mm bore medium grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC chamber in cement concrete (1:3:6) type C-2 & RCC cover in M-20 (Design Mix) and all as shown in Electrical Plate No. 3 of SSR (Part-1)of 2009. all as specified.
Supplying and Fixing on load change over switch in sheet metal enclosure suitable for 63 Amps four pole front handle operated AC 22 categorynconfirming to IS :13947-3 415 volt AC 50 HZ including provision of cable entry of 50 Sqmm 3.5core all as specified and directed.
Supply, installing, testing & commissioning of CPRI approved LT panel board, outdoor type, cubical, dust and vermin proof made out of 3.15 mm thickness MS sheet and 50x50x6mm with front and back door openable type fitted with nuts, bolts and washers fitted with knobs and ginges and air vents incl painting with two coats of enamelled paint over a coat of red oxide primer, suitable for 415 V , 50 Hz, 3 phase, 4 wire suitable for and incl the following :- (a) MCCB conforming to IS-13947(P-2) 4 pole, 100 Amps,415 Volt,AC 50 HZ adjustable type, breaking capacity 35/36 KA- 01 No. (b) MCCB conforming to IS-13947(P-2) 3 pole, 63 Amps,415 Volt,AC 50 HZ adjustable type, breaking capacity 25 KA- 02 Nos. (c) MCB TPN 32 Amps B series 415 Volt,AC 50 HZ - 01 No (d) Digital voltmeter 0-500 V-01 No (e) Digital Ameter with CT 0-200 Amps-01 No (f) LED indicator lamp-03 Nos (g) Copper bus bar chamber of capacity with insulated copper bus bar of 200Amps TPN with bub bar insulator-01 (j) Internal wiring with suitable size single core copper conductor cable of Red, Yellow, Blue and black colour including lugs, ferrule, tag etc.
Supplying, transporting to site, erecting and fixing in position, 11 mtr long and type 410 SP-55 steel tubular swaged and welded poles, ISI marked with with cast iron base plate, finial taper plug, bolts, nuts,washers & screws etc as specified complete, including painting outside with two coats of aluminium paint over a coat or red oxide primer on exposed surfaces and black bituminous paint on steel surface embedded in concrete complete all as specified and directed.
DEMOLITION WORKS
Removing debris obtained from demolition exc. 50m but n. exe. 250 m depositing where directed complete all as directed.
DG SET WORKS
Supply, install, commissioning and testing complete silent Diesel Engine driven generating set with canopy and accoustics as per guide line issued by CPCB and environment act ( 415 volts, AC supply 3 Phase, 50 HZ , 4 wire system of supply) with panel of automatic starting omn main failure control suitable of giving an output of 50 KVA or of next higher capacity as available/manufactured after considering power factor as per IS-10001/10002 and alternator as per IS-13364 complete at 1610 metre altitude above mean sea level and capacity of operating between temperature range minus 15 degree celcius to plus 35 degree celcius in Sonamarg area of J&K and alternature of suitable capacity coupled with each other and capable of taking 10% over load for one hour in every 12 hours as per BS-5514/649 with flexible coupling mounted on common base plate on anti vibration pads on foundation recommended by manufacturer. The DG set shall comprise of electric starter motor with batteries turbocharger water cooled and comprising all standerd fittings/fixtures all piping etc water cooled/with radiator complete with inbuilt tank of capacity as per manufacturer specifications and shall comprise the following :-
(A) Diesel Driven Engine : Developing a net rated output of 100 BHP or next higher capacity suitably matched with alternator to give a net rated output of 50 KVA. The engine should be capable of delivering the required output of 1500 RPM as per BIS 649 under NTP condition with a provision of 10% over load for one hour in every 12 hours and interalia with the following accessories all as specified:- (i) Fly wheel to suit flexible coupling and fly wheel housing. (ii) Air cleaner complete as per manufacturer specifications. (iii) Fuel injection rotarty nozzle pump. (iv) Electric governor. (v) Oil filter and mounting. (vi) Flexible coupling with guard nuts and bolts. (vii) Fuel filter and mounting. viii. Lubricating oil pump and oil cooled. ix. Starter motor as per manufacturer design. x. Lubricating oil cooler. xi. Exhaust silencer, industrial type with exhaust pipe of length, beyond impeller from wal from DG set room. xii. Drip tray xiii. Battery charger of suitable cap fitted with transformer/Rectifier unit DC ammeter/off/trickle/ boost switch, DC volt meter and other standard fitting hour running meter, kwh meter etc. xiv. 02 nos maintenance free battery 180 AH, 12 volt. xv. Cold start kit.
(B) ALTERNATOR :- The -+above engine will be coupled through flexible coupling on an indigenous alternator mounted on strong steel fabricated common base frame suitable for mounting in an acoustic. The alternator will be 3 phase 50 HZs 1500 RPM self-regulating self-exciting type and generating 50 KVA out put at 0.8 power factor 4 wire 415 volts AC supply under NTP condition with a provn of 10% overload for 1 hour in every 12 hours running at 1500 RPM, the alternator shall be screen protected and fitted with shield ball/roller bearing conforming to BS 2613/is 4722.
(C) MANUAL CONTROL PANEL :- The control panel body will be fabricated out of 16 SEG MS sheet. Panel will be suitable for canopy mounting indoor installation, dust & vermin proof, copper control cable of suitable size is used. Cable are ferruled for proper maintenance/checking/wiring of panel. Detachable cable gland plates are provided. The panel will be equipped as follows :- (a) One no moulded case circuit breaker of suitable capacity. (b) Aluminum Bus bars suitable capacity provided with termination. (c) 03 Nos current transformers of suitable ratio. (d) One set of instrument MCB’s (e) Microprocessor protections with display and indications of electrical and mechanical parameters as per manufacturers design and specifications.
(D) FOUNDATION :- PCC 1:2:4 foundation for DG set of suitable size complete all as per site requirement. Note :- (a) The complete generating include Engine/alternator shall be factory assembled by manufacturer or its authorized dealer as approved for assembling of the DG set. Make of assembler shall be :- (i) M/S Bhasker Power Project. (ii). M/S green field Enterprises (iii). M/S IEC Ltd. (iv) M/S Sudhir Gensets. Model C50DT5P (v) M/S Cater Piller. (B) First filling of Engine oil and fuel etc should be arranged by contractor for complete testing as directed.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .