| 1 | L1₹37.5 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹40.7 L+₹3.2 L (8.49%)Rejected-Finance HOSPITAL ROAD TEZPUR 784 001 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L2 | Rejected-Finance Not L1 |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
19 Nov 2022, 6:00 pmClosed
GE AF TEZPUR
GE AF TEZPUR,PO-SALONIBARI,DIST-SONITPUR,ASSAM
SPECIAL REPAIR TO FLOORING IN PRIMARY SECTION OF KV SCHOOL No.2 AND PROVISION OF WIRING FOR INSTALLATION OF AIR CONDITIONER AND GEYSER IN SMQs AT AF STN TEZPUR UNDER GE (AF) TEZPUR.
2022_MES_539625_4
GE(AF)/TEZ/8667 OF 2022-2023
Open Tender
Civil Works - Others
Item Rate
180 days
TEZPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) TEZPUR
₹73,000
Yes
31 Dec 2022
2 Nov 2022
21 Nov 2022
2 Nov 2022
19 Nov 2022
7 Nov 2022
Amount
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.,complete all as specified and directed.
Taking down shutters of any description n exc 1sq. m each and refixing in the same opening,complete all as specified and directed.
Supply and Fix in repairs,stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
Materials and Labour for machine cut Kota stone slab flooring 20-25 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15 mm thick screed bed or bedding layer of cement mortar (1:6),complete all as specified and directed.
Materials and Labour for machine cut Kota stone slab 20-25 mm in raisers of steps, skirting, dado and pillar,laid over and including 10 mm thick screed bed of cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing,complete all as specified and directed.
Material and Labour for preparing old surfaces plastered or unplastered and applying one coat of white wash,on ceiling,complete all as specified and directed.
Material and Labour for washing,rubbing down and stopping of distempered and painted surfaces and applying one coat of distemper oil emulsion,on walls, complete all as specified and directed.
Material and Labour for,3 mm thick sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane,including hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads,complete all as specified and directed.
Material and Labour for applying one coat of synthetic enamel paint (ordinary tint) on old painted wood or wood based surface of any description,over 10 cm in width or girth, not otherwise described, including preparation of surfaces complete all as specified and directed.
Material and Labour for applying one coat of synthetic enamel paint (ordinary tint) on old painted sttel and iron surface of any description,over 10 cm in width or girth, not otherwise described, including preparation of surfaces complete all as specified and directed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 4.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing and capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 4.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/ aluminium circuit/submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 4.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade,drawn in existing surface/recessed steel/PVC conduit and continuous earth wire of single core FRLSH PVC insulated,unsheathed cable 4.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/ aluminium circuit/submain wirings of any size (2 runs single core and earth continuity) complete including removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 6.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing and capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 6.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring,including taking down carefully existing copper/ aluminium circuit/submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 10.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade,drawn in existing surface/recessed steel/PVC conduit and continuous earth wire of single core FRLSH PVC insulated,unsheathed cable 10.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/ aluminium circuit/submain wirings of any size (2 runs single core and earth continuity) complete including removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 10.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing and capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 10.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring,including taking down carefully existing copper/ aluminium circuit/submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
Supply and Fix in repairs,single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 240V, complete all as specified and directed. [Cat No. 5078 11 of Make Legrand or equivalent Model of Make L&T/ Hager/Seimens/GE/Schneider/ABB]
Supply and Fix in repairs, Double Door,Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 4 way, with 200 Amps rated bus bar, Single Pole & Neutral,complete all as specified and directed. [Cat No. 5076 10 of Make Legrand or equivalent Model of Make L&T/Hager/ Seimens/GE/Schneider/ABB]
Supply and Fix in repairs, Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts,12 way, with 200 Amps rated bus bar, Single Pole & Neutral,complete all as specified and directed. [Cat No. 5076 12 of Make Legrand or equivalent Model of Make L&T/Hager/ Seimens/GE/Schneider/ABB]
Supply and Fix in repairs, Double Door, Sheet Metal Enclosure for DBs,415 Volts, 4 Way,Triple Pole & Neutral,complete all as specified and directed. [Cat No. 5076 70 of Make Legrand or equivalent Model of Make L&T/Hager/ Seimens/GE/Schneider/ABB]
Supply and fix miniature circuit breaker (MCBs) single pole, 240 Volts, 10KA, 6 to 32 Amps complete all as specified and directed. [Cat No. 4085 87-4085 95 of Make Legrand or equivalent Model of Make L&T/Hager/Seimens/GE/Schneider/ABB]
Supply and fix miniature circuit breaker (MCBs) single pole and neutral, 240 Volts, 10KA, 6 to 32 Amps complete all as specified and directed. [Cat No. 4086 09-4086 17 of Make Legrand or equivalent Model of Make L&T/ Hager/Seimens/GE/Schneider/ABB]
Supply and fix miniature circuit breaker (MCBs) single pole and neutral, 240 Volts, 10KA, 40 Amps complete all as specified and directed. [Cat No. 4086 18 of Make Legrand or equivalent Model of Make L&T/ Hager/Seimens/GE/Schneider/ABB]
Supply and Fix, miniature circuit breaker (MCBs) triple pole, & neutral, 415 Volts, 10KA, 63 Amps complete all as specified and directed. [Cat No. 4086 83 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Materials and Labour for,earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire, complete all as specified and directed.
Materials and Labour for earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanised steel earth lead wire 4 mm dia. by means of bolts, nuts check nuts and washers of galvanised steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia. MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil complete all as specified and indicated on electrical plate No 3 of SSR Part –I (2009) including testing on completion.
M/S LAKSHMI ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .