Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Renovation of existing Air Conditioning system by Providing, Installation and commissioning of new Air Conditioning Machines and others related materials inc 3 years Comprehensive Annual Maintenance Contract for Auditorium of Sukanta Academy, Ag
2022_CEPWD_33393_1
07/B/DNIeT/SE-IV/PWD(RANDB)/20
Open Tender
Electrical Works
Works
1580 days
AGARTALA
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹93,559
21 Dec 2022
3 Nov 2022
10 Nov 2022
3 Nov 2022
10 Nov 2022
3 Nov 2022
Amount
Providing for Installation, commissioning of Air Cooled Microprocessor based minimum 25 TR (minimum 87.9 Kw) Chiller condensing unit of following capacity with Hematic scroll Compressor having Tandem Compressor design 15-20% energy saving at part load, run time equaliser, operating on 3-phase /50 Hz/380-415V, Maximum, Outdoor unit shall be factory assembled weather proof casing constructed from heavy gauge mild steel, the outdoor unit should contain error code diagnosis function for ease of operation, the system should be equipped with eco-friendly refrigerant 407C/ R 410A or equivalent, the outdoor units shall be complete with all safety devices etc. and also dismantling of existing chiller plant, AHU with it’s existing copper pipe & fittings, sheet metal and related all accessories (unserviceable) and disposal of all old unserviceable materials from the site through by back system etc. complete as per direction of the Engineer-in-Charge.
Providing for Installation, commissioning of minimum 10000 CFM capacity with 60 mm static pressure for 25 TR , Floor Mounted Type double skinned Air Handling Unit compatible with 25 TR (87.9 Kw) Chiller condensing outdoor Unit, consisting of 43 ± 2 mm thick PUF insulated Aluminium section frame construction with necessary dampers and thermal break profile a) Fan section DIDW backward curve imported fan MK. Krugar/ Nikotra , The AHU shall consist of TEFC squirell cage induction motor b) Coil section with 6 row deep (0.41 mm thick ) with air cooled cooling coils with washable pre filters with 90% efficiency down to 10 microns c] TEFC sq. cage induction motor d} Sandwiched SS Drain Pan d) Hydrophilic Fin with fin Spacing 1.4 mm complete with copper Tube (Copper Tubes should be of IS standard,, Maximum Noise Level: 50 or bellow dB, the unit must be with highly acoustic insulation, e) Controller Set: Corded Controller with temperature display and control option (Make: Edgetech, Zeco, Ravi Aircon, Carrier complete as per direction of the Engineer in charge.
Lifting, shifting, positioning & Fitting Fixing of Outdoor & Indoor Unit (AHU) 25 TR each, on RCC support/by providing MS structure & AHU to be fitted at respective Hall ( AHU room) in/c proper rigid clamping Cu Refrigerant pipe line , Communication cable (through PVC enclosure)between Outdoor & Indoor units, & also the necessary all electrical connections to be connected in the both units from power supply by cables(Only fitting fixing) in/c Gas charging (only labour), Leak testing, Pressure checking by providing Nitrogen , commissioning & testing etc. complete as per direction of the Engineer in charge.
Designing, fabrication & erection of GI sheet metal Ducting in/c providing necessary flanges, gaskets, bracings and supports complete as per direction of the Engineer in charge. 22 G
Supply & erection of Thermal insulation with 13 mm thick Nitrale with aluminum foel complete as per direction of the Engineer in charge
Supply & fixing of Duct acoustic insulation (sound absorbtion capacity) with minmum 10-13 mm thick open cell nitrale rubber (Inside) in/c 28 G alluminium perforated sheet complete all necessary fitting arrangement complete as per direction of the Engineer in charge.
Providing for fitting fixing of different sizes of Hard drawn Pure copper Refrigerant pipe with cooper fittings, tube insulation of 19mm for connection of "AHU" along with it's fittings etc. complete as per direction of the Engineeer in charge. (Make: Mandev/ Rajco/ Maxflow) 15.9 mm (5/8 inch)
34.9 mm (1-3/8 inch)
Providing & installation of 25mm NB PVC drain piping complete as per direction of the Engineer in charge
Providing & connecting Electric control cables between indoor & outdoor, Machine room Supply point to indoor machine suitable cable for 3phase line in/c Nutral etc complete as per direction of the Engineer in charge
Supply & erection of Fire retardant, double layer canvas connection complete as per direction of the Engineer in charge.
Providing & Installation VI Pad for outdoor unit complete as per direction of the Engineer in charge.
Providing & Installation motorised Fire dampers with fusible link complete as per direction of the Engineer in charge
Sand Cement Plastering (1:4) of the outside Duct in/c wraping Chicken Wire Mesh on the insulated duct & necessary M.S. angle Support as per direction of the Engineer in charge
Supply & erection of Thermal insulation with 50 mm thick thermocol slab /19 mm Nitrale for out side duct complete as per direction of the Engineer in charge
Providing fitting fixing of thermal insulation of 50 mm thick resin bonded fiber glass insulation covered tissue board or 32 mm XPL sheet on the wall and ceiling fixed with frame work with GI channel covered with 26G AL perforated sheet and finaly fixing with Al flat in complete as per direction of the Engineer in charge
Providing & fitting fixing of of electronic Expansion valve for 25 TR with hand shut valve, silica dryer filter with suported Gi TRAY of the same as per site Requirement (Danfoss/ Sporlan make) complete as per direction of the Engineer in charge
Providing for fitting Fixing of PVC Conduit Communication Cable , size 2C X 1.5 Sqm mm dia etc. complete as per direction of the Engineer-in-charge
Providing of refrigerant gas 410/ R-410 A / 407 C as a standard requirement for charging etc. Complete as per direction of the Engineer-in-charge
Comprehensive Annual Maintenance Contract after 1 year warranty period Comprehensive Annual Maintenance Contract in 2nd Year
Comprehensive Annual Maintenance Contract in 3rd Year
Comprehensive Annual Maintenance Contract in 4th Year
RS COOLING APPLIANCES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_33919.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .