Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC | ₹9.6 L | L1 | Accepted-AOC awarded |
| 2 | L2₹10.4 L+₹83,869 (8.77%)Rejected-Finance | ₹10.4 L+₹83,869 (8.77%) | L2 | Rejected-Finance Rejected being L2 firm/ contractor |
Tender Value
₹9.6 L
EMD Value
₹19,200
Closing Date
20 Aug 2021, 10:00 amClosed
Executive Engineer, Electrical Division, HP.PWD M
Executive Engineer, Electrical Division, HP.PWD Mandi
Laying standby medical oxygen copper line from Oxygen Plant to main riser at Shri Lal Bahadur Shastri Govt. Medical College and Hospital, Nerchowk Distt Mandi HP
2021_PWD_51123_1
PW/MED/TA/NIT/ e-notice/21-22-3221-31 dt 02.08.21
Open Tender
Electrical Works
Item Rate
60 days
Nerchowk
Please refer to bid document
11 documents required · 11 mandatory
₹350
Executive Engineer, Electrical Division, HP.PWD M
₹19,200
13 Oct 2021
13 Aug 2021
20 Aug 2021
13 Aug 2021
20 Aug 2021
13 Aug 2021
Amount
Copper Piping :
Installation:
Installation of piping should be carried out as per international standards with utmost cleanliness. Only pipes, fittings and valves which have been degreased as per International standards should be used. Pipe fixing clamps for upto 28 mm diameter. Pipes should be non ferrous suitable for the diameter of the pipe. For the pipes of the sized above 28 mm rigid metallic hanging or cemented supports to be used.
The main lines to the building to be taken overhead through metallic poles or through underground ducts with inspection removable slabs, All pipe joints should be made using inert gas flux less brazing method. All joints should be of copper to copper and should be brazed by silver brazing filler material without flux while being brazed joints shall be continuously purged with oil free dry nitrogen to prevent the formation of copper oxide on the inside surface of the joint. All pipes should be installed without springing or forcing. All pipes should be protected against mechanical injury in a manner satisfactory to authorities having jurisdiction.
Test: After erection, all the new pipes cleaned or purged with the help of dry nitrogen gas. Complete system should be tested with dry nitrogen at 2 times of working pressure for 24 hours.
Painting: All existing and proposed exposed pipes/should be painted with two coats of Synthetic enamel paint & color codification as per international standards. All concealed pipes to have gas identification bands / labels at appropriate distance. Similarly all pipes which need embedding in the wall should be tested /painted/labeled and properly insulated.
Certification: To be certified that pipes are suitable for the particular service and complete cross connection (anti-confusion) test will be carried out.
Lolyd’s
Copper Pipe Size 22mm x 0.9mm Thickness
Copper Pipe Size 76mm x 1.6mm Thickness
Poles for Rise and protection for pipes for riser
SITC of horizontal/vertical bed head panel (CE marked ) as mentioned below
Bed head panel should confirm to NEPAGG/HTM-02-01/ISO-7396-I/DIN/EN.
Efficient safe & robust design in extruded aluminum section.
Smooth curved surface and choice of base column and fascia plates.
Unit should be constructed of aluminum extrusions joined together.
Unit should be factory assembled.
Unit should have electrical and mechanical components
Unit should have built light feature.
Following accessories should be provided locally with HBHP :-
5/15 amp modular electrical socket with switch 6sets
7V pole-2 no
Vacuum slide – 2no
Sliding block- 2no
Nurse call system module (cut out provision only)-1no
Utility basket – 1no
Bed head panel -
ULTIMED SOLUTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .