Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.6 LAccepted-AOC 40 608A PULLOMPARAMBLI HOUSE MANDAKKARA ROAD KOCHI 682 018 | KOCHI | ERNAKULAM | KERALA | 682018 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹74.4 L+₹6.8 L (10.0%)Rejected-AOC GP KIZHAKKAMBALAM KOLENCHERY | THRISSUR | KERALA | 680667 | L2 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | VIJAY CONSTRUCTIONS L2 | WELTRONENGINEERINGSERVICES L1 |
|---|---|---|---|---|---|
| 1.00 | Total Amount of Sch 'A' part - I (Buildings/ Structures) | 1 | Lumpsum | 33,88,800 ₹33,88,800 | 33,86,000 ₹33,86,000 Lowest |
| 2.00 | Total Amount of Sch 'A' part - II (Earthwork/ Excavation/ site clearance) | 1 | Lumpsum | 53,646 ₹53,646 Lowest | 1,02,743 ₹1,02,743 |
| 3.00 | Total Amount of Sch 'A' part - III (Pile Foundation) | 1 | Lumpsum | 1,27,182 ₹1,27,182 | 67,428 ₹67,428 Lowest |
| 4.00 | Total Amount of Sch 'A' part - IV (Internal Water Supply) | 1 | Lumpsum | 36,330 ₹36,330 Lowest | 53,750 ₹53,750 |
| 5.00 | Total Amount of Sch 'A' part - V (Internal Electric Supply) | 1 | Lumpsum | 2,08,195 ₹2,08,195 | 1,78,469 ₹1,78,469 Lowest |
| 6.00 | Total Amount of Sch 'A' part - VI (Sewage Disposal) | 1 | Lumpsum | 27,298 ₹27,298 Lowest | 31,034 ₹31,034 |
| 7.00 | Total Amount of Sch 'A' part - VII (Hardstanding/ Path) | 1 | Lumpsum | 3,35,781 ₹3,35,781 Lowest | 4,02,210 ₹4,02,210 |
| 8.00 | Total Amount of Sch 'A' part - VIII (External Water Supply) | 1 | Lumpsum | 31,870 ₹31,870 Lowest | 48,600 ₹48,600 |
| 9.00 | Total Amount of Sch 'A' part - IX (External Electric Supply) | 1 | Lumpsum | 54,948 ₹54,948 | 46,280 ₹46,280 Lowest |
| 10.00 | Total Amount of Sch 'A' part - X (Air Conditioning) | 1 | Lumpsum | 25,846 ₹25,846 Lowest | 27,300 ₹27,300 |
Tender Value
₹74.7 L
EMD Value
₹1.4 L
Closing Date
26 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri RK Singh IDSE CWE(NW) Kochi
CWE(NW) Kochi
PROVISION OF INFRASTRUCTURE FOR HYDRAULIC PRESSURE TESTING HEED CHARGING AND CO2 CHARGING AT SE SECTION INS GARUDA KOCHI
2025_MES_740610_1
CWE(NW)KOCHI/81616
Open Tender
Civil Works
Lump-sum
270 days
Kochi
As per NIT
6 documents required · 6 mandatory
₹1,000
GE(NW) Kochi
₹1.4 L
Yes
5 Mar 2026
21 Nov 2025
29 Dec 2025
21 Nov 2025
26 Dec 2025
19 Dec 2025
Amount
Total Amount of Sch 'A' part - I (Buildings/ Structures)
Total Amount of Sch 'A' part - II (Earthwork/ Excavation/ site clearance)
Total Amount of Sch 'A' part - III (Pile Foundation)
Total Amount of Sch 'A' part - IV (Internal Water Supply)
Total Amount of Sch 'A' part - V (Internal Electric Supply)
Total Amount of Sch 'A' part - VI (Sewage Disposal)
Total Amount of Sch 'A' part - VII (Hardstanding/ Path)
Total Amount of Sch 'A' part - VIII (External Water Supply)
Total Amount of Sch 'A' part - IX (External Electric Supply)
Total Amount of Sch 'A' part - X (Air Conditioning)
Sch 'A' Part - XI (Miscellaneous items) (BOQ) (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col. 5 signifies this fact only)
PILE FOUNDATION
M&L for Sand Compaction pile 100mm dia using standard engineering practice to a depth of 5.50m from ground level including preparation of hole of pile at an interval of 300mm c/c and filling with 6mm thick coarse aggregate and all related incidental items of work complete all as specified and as directed by Engr -in- Charge. Note: (a) The rate shall include mobilisation, erection, dismantling and demobilisation of equipment for preparation of holes for sand pile including all labours and materials. (b) The rate shall include for dewatering the site using suitable method. (c) The cost for suitable methods / supports required for preventing the sliding of sourrounding soil is also deemed to be included in the quoted rate.
M&L for Granular Sub base, spread, rolled and consolidated to gradient and camber required all as per specified and as directed by Engr-in-Charge. Note : Suitable water draining method should be adopted while carrying out foundation works due to water table is appx 0.70m below GL.
Carrying out Plate load test after completing ground improvement work on soil as per standard procedure laid down in IS 1888-1982, clearing the site and maintaining complete record of load settlement etc as specified nad directed . Note : Quoted rate rate shall include the cost of dewatering.
S&F 150 micron HDPE sheet complete all as specified and shown on drg
INTERNAL ELECTRIC SUPPLY
S&F LED flat panel with high brightness with glare free recessed 2 feet by 2 feet 36/40 watt endure slim pro plus fitting including all as specified and as directed.
SEWAGE DISPOSAL
S&F RCC Hume pipe septic tank for 10 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc complete all as shown in Drg no. TD/A/157 sheet no. 1/1 and as directed.
S&F Soakage pit of 10 User Size 2.7mtr and 3.10mtr depth as shown on drg No.TD/A/161 sht No.1/1. complete all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY
S&F SS enclosure for MCCB 160 Amp complete all as specified and as directed. Make L&T cat CM91003OOOO of equivalent manufacturer listed in list of manufacturers.
S&F MCCB 4 pole, 415 Volt fixed type 160 Amps with breaking capacity 36 KA complete all as specified and directed. Make Havells Cat part No IHA13EB40160 or equivalent make in PS.
M&L for modification of existing LT panel for accomodating the MCCB including welding, cutting, painting of the existing panel for new connection all as specified and directed.
Cutting existing road/hardstand/concrete blocks/slabs/brick work or stone masonry of any type by using crow bar chisel up to a depth of 30 cm for laying Gl pipe including making good the surface by returning filling watering ramming in layers cold mix bitumen over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed.
AIR CONDITIONING
Supply, installation, testing and commissioning of split air conditioning unit 1.5 TR capacity (Inverter type) with HD filter complete with cordless remote control, 5 star labelled, latest model energy efficent model eco friendly, 4500 Kcal/Hr, 50 Hz, 240 volts, air cooled condenser with 100% copper & Goldfin coating and 100% copper cooling coil with ocean black protection complete all accessories varied speed including fixing the out door unit with suitable stand as per site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/supports/making holes to pass the refrigerant pipes(by using core cutting machine) drain pipes to reach nearest drain, cables etc and making good to match with existing finishing complete, providing and making interconnection, including refrigerant pipes with nitrile rubber insulation and control cable from indoor to outdoor upto a distance as per site requirement, as per site requirement and first charging of refrigerant gas including cordless remote, connection drain lines from unit to nearest drain points complete all as specified. Make: Daiken/Hitachi/LG/Blue star Note: (i) All outdoor units must be installed/ placed in service friendly location /as per the direction of Engr-in-charge. The bidder must visit the site before bidding to ensure feasibility of location to ensure requirement of refrigerant pipes/electrical fittings (ii) The bidder should install the AC by the auth rep of OEM and provide test ceetificate. (iii) The ACs should have warranty for 10 years on compressor, 05 yrs warranty onPCBs, and 01 year comprehenssive warranty. In this condition the contractor has to submit the warranty certificate by the OEM before claiming the RAR. (iv) Extra copper pipe if required (from indoor to outdoor unit) is included in the unit rate.
Supply and fix 4 KVA capacity Voltage stabilizer, copper wounded suitable for 1.5 TR inverter type split AC, automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and speed of correction 8 volts per second, fixed on wall with necessary arrangements complete all as specified. Make: V Guard/AE/Microtek
VIJAY CONSTRUCTIONS (BID ID -3505903)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
Tenderdocument.pdf
Tender Documents • 2.26 MB
CT202-STR03_merged.pdf
Additional Documents • 0.95 MB
BOQ_829589.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .