Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.9 LAccepted-AOC KURUPPAMPARAMBIL PERUMPADAPPU PALLURURHY P O ERNAKULAM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L2₹44.2 L+₹2.9 L (6.92%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
₹44.9 L
EMD Value
₹89,800
Closing Date
22 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NW)KOCHI
GARRISON ENGINEER (NW) MILITARY ENGINEER SERVICES NAVAL BASE POST -682 004
AS PER BOQ AND TENDER DOCUMENT
2023_MES_610360_1
8264_GE_NW
Open Tender
Civil Works
Item Rate
240 days
KOCHI
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE(NW)KOCHI
₹89,800
Yes
23 Nov 2023
24 Jul 2023
24 Aug 2023
24 Jul 2023
22 Aug 2023
5 Aug 2023
24 Jul 2023 - 10 Aug 2023
Amount
Taking down of existing roof treatment consisting of screed bed /plaster, tar felts etc and removal of dismantled materials to outside MD land complete all as specified and directed by Engr in Charge.
M&L for Cement concrete type B1, 1:2:4 (20mm graded stone aggregate) for coping or chamfered on edges and as levelling courses of concrete in roof slab all as specified and as directed.
S&F Galvanized Z sections (Z shaped GI sub-girt of size 50x50x50-2mm thick) as in purlins where connected on RCC slab with fastener of 10mm dia and 40mm long and galvalume sheet connected to Z purlin with SDST screws of 12G x 14 TPI-55mm (L) complete all as specified and as directed by the Engineer-in-Charge. Note:-The rate shall be inclusive of the rate of fastener and SDST screws etc complete)
Providing and applying pitch free polyethylene water proof coating using Fosroc Nitoproof 600 or equivalent, over dry surface @ 1.5mm thick in 2 coats with interval period of 6 hours over a substrate @ coverage rate of 2Kg/Sqm using spray/squeegee/ roller/ brush. Water proofing coating shall have the elongation of 200% (ASTM D412-90, Tear resistance of >7N (ASTM D 624-00), and tensile strength of 1.5N/mm2 (ASTM D412-90) and it should have a solid content of 80-85% Note:- The rate includes the application of the chemical with specialized agency or the manufacturer.
S&F Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge , Gutter, Gable flashing, corner flashing etc, fixed with self tapping screws as specified and directed.
Dismantling structural steel work including of old aerial mast, doors, gates but excluding framed truss etc complete all as specified and as directed.
S&F mild steel work in framing, purlin using section such as angle, hollow pipes , flats , etc using Fe-290 Grade E-165 complete.
Taking down chowkat or frames with shutters (without taking off shutter from the frame) of area n.exc 1.50 Sqm each complete all as specified and directed.
Taking down chowkat or frames with shutters (without taking off shutter from the frame) of size exc 1.50 Sqm and n.exc 4.00 Sqm each. and removing from site complete all as specified and directed.
S&F IInd class hardwood plain solid straight chowkat and frame wrought framed, rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
S&F MS work as in hold fast and similar small articles conforming to Fe-290, Gde E-165 complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 (Using 20mm graded stone aggregate) as in cills, copings, bed blocks for hold fasts and the like complete all as specified and directed.
S&F 35mm thick IInd Class hard wood (rail and style Plain framed) factory made panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply. The size of rail and stile as per IS : 1003(Part I), kiln seasoned and chemically pressure treated as completed as specified.
S&F mild steel framed work as in door, chowkat, grills, gratings etc with ends of bars shouldered and riveted or forged into spikes, framed guard bars, barred iron doors etc, conforming to Fe-290, Gde-E-165 all as specified and directed.
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm ivory colour PVC sheet reinforced with MS square tube, as per specification and drawing shown in SSR Part II and directed.
S&F Factory made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile) with wood free EPS, with 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Plain colour PVC sheet on back face, S&F in frame at site as per specification & drawing all as specified.
S&F 100 mm long mild steel butt hinges medium weight
S&F Aluminium anodized barrel tower bolt 200mm long of extruded section complete all as specified and directed.
S&F Aluminium anodized sliding door bolt 300mm long with hasp and staples (bolt type) and fixing clips of sheet cast of extruded section and fixing bolts and sliding bolts of extruded section complete all as specified and directed.
S&F Aluminium bow handle "D" type anodized 150mm long complete all as specified and directed.
S&F stainless steel curtain rod including rings, knobs and brackets complete all as specified and directed.
Dismantling wall/floor tiling / terrazzo tile/ mosaic tiles/ PCC tiles incl. cement mortar bedding and removing rubbish off the premises complete.
M&L for joint free Non-skid ceramic coloured tiles 7-8mm thick (square/ rectangular) in floor, area of each tile not exc 0.11 Sqm, over and including 10mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed by Engr-in-Charge.
M&L for Glazed ceramic coloured joint free tiles 450x300X7mm/600x300x7mm in vertical surfaces over and including 10mm thick rendering in Cement mortar (1:3), set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed by Engr-in-Charge
M&L for joint free coloured Non Skid ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and incl 15mm thick screed bed of CM 1:6 all as specified and directed.
M&L for joint free coloured Non Skid ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in vertical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and incl 10mm thick rendering of CM 1:3 all as specified and directed.
M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) stone slab as in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust to match with marble shade over and including cement screed bed 15mm thick in CM (1:6) complete all as specified and directed by Engr-in-Charge.
Providing edge moulding to 18-20mm thick granite stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base of floor complete all as specified and directed by Engr-in-Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr-in-Charge.
M&L RCC (1:2:4) type B-1 (Using 20mm graded crushed stone aggregate) as in slabs, shelves supported on walls, beams and columns in floor or roof including balconies, canopies, deck slabs or in Chajja/facia projection and the like complete all as specified and directed by Engr-in-Charge.
M&L mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
M&L for use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for fair finished surfaces (Horizontal or sloping) complete all as specified and directed by Engr-in-Charge.
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed.
M&L for precast cement concrete block masonry in type B1, 1:3:6 (20 mm graded stone aggregate) with solid blocks exc 10 cm in width and setting in cement mortar 1:6 in foundation of load bearing wall and wall complete all as specified and directed.
Taking down cement plaster of any description on brick work or stone masonry walls including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engr-in-Charge.
M&L 15mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
Mel for rendering 8mm thick in CM 1:4 with liquid WPC over 12mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces finished even & fair without using extra cement complete all as directed. Note:- Water proofing compound shall be measured and paid separately.
M&L 5mm thick rendering in cement mortar (1:3) on ceiling , finished the surfaces even and fair without using extra cement complete all as specified and directed by Engr-in-Charge.
Supply only liquid water proofing compound complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed by Engr-in-Charge.
M&L 75mm thick PCC (1:3:6) type C-2 (Using 20mm graded crushed stone aggregate) as in plinth protection /hardstanding , laid in panels, finished the top surfaces even and fair without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engr-in-Charge.
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper , a coat of suitable primer over and including 1.5mm thick wall care putty complete all as specified and directed by Engr-in-Charge.
M&L for preparation new plastered External surfaces of wall and applying two coats of weather proof paint (antifungal, Asian Ultima Protek oe Equivalent) over a coat of suitable primer complete all as specified and as directed by the Engineer-In-Charge. Note:- Application of paint, primer and wall care putty shall be as per manufacturer's instruction.
M&L for preparation of old ceiling surface and applying one coat of white wash complete all as specified and directed by Engr-in-Charge.
M&L for Complete removal of existing surface finishes of external wall, preparation of surface and applying two coats of weather proof (antifungal, Asian Ultima Protek or equivalent) paint over a coat of suitable primer complete all as specified and as directed by the Engineer-In-Charge. Note:- Application of paint and primer shall be as per manufacturer's instruction.
M&L Complete removal of existing surface finishes of internal wall, preparation of surface and applying two coats of Oil bound distemper over one coat of suitable primer over and incl 1.5 mm thick wall care putty complete all as specified and directed. Note:- Application of paint, primer and wall care putty shall be as per manufacturer's instruction.
M&L for preparation of new surfaces of wood and wood based materials of any descriptions not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new surfaces of steel surface of any descriptions not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F Aluminium powder coated fixed type windows including suitable nylon beading channel gasket etc complete with following specification :- Frame :- 63.50mmx38.10mmx1.50mm Panel :- 4mm thick ACP sheet / 5mm thick tinted/frosted glass of approved colour and design
S&F aluminium powder coated door shutter with frames of size - 44.50mm x 50mm x 1.50mm incl. screwing of frame glass necessary joints cleats, glazing clips rubber packing, snap beading, suitable handle, tower bolt, SS butt hinges, mortice lock 4 lever with 65 mm latch size including aluminium anodized door frame of size 63.50mmx38.10mm x 1.50 mm thick fixed to wall with necessary screws and plug complete all as specified & directed. (rates for one No. hydraulic door closer per shutter & 5 mm thick tinted glass /4mm thick ACP sheet required to be fitted in shutters is included in the item )
S&F aluminium powder coated partition fixed / sliding type with frames of size -side , top rail and intermediate sections size 63.50mm x 38.10mm x 1.50mm , incl. screwing of frame glass necessary joints cleats, glazing clips rubber packing, snap beading, fixed to wall with necessary screws and plug complete all as specified & directed. (rates for 5.00 mm thick tinted glass / 4mm thick coloured aluminium composite panels required to be fitted in shutters is included in the item)
S&F in repair vitreous china squatting pan ‘Orissa pattern’ size 580x440mm white with integral foot rest including connection to trap, and flushing pipe, anti-syphonage pipe, etc and including lime concrete bedding complete all as specified and directed.
S&F in repair PVC flushing cistern low level 8 to 10 Ltr capacity of approved make including fixing of brackets connection to WC with CI brackets and making good disturbed area complete all as specified and directed.
S&F in repair vitreous china WHB white with flat back of size 550x400mm with bracket including waste coupling and PVC waste pipe complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan pedestal pattern white including fixing with trap including PVC matching seat cover complete all as specified and directed.
S&F in repair brass CP towel Rail 600mm long "D" type complete all as specified and directed.
S&F in repair vitreous china soap dish fixed to wall with screw complete all as specified and directed.
S&F in repair 15mm bore Pillar taps, in repair cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed.
S&F in repair Vitreous China urinals, half stall type complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; with PTMT Urinal spreader, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
S&F 18/19mm MDF DWR Pre-laminated particle board, interior grade, pre-laminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work including beading and matching for exposed edges of board complete all as specified and directed.
M&L 2nd Class hardwood Plain fillets. square, rectangular or triangular in section exc 6 sq cm not exc 13 Sq cm , clean sawn, secured with nails or brads complete all as specified
S&F 30mm width of flaps Continuous (Piano) hinges, mild steel, bright finish or electro-galvanised complete all as specified and directed.
S&F for 40mm dia cupboard knobs fixed with nut, screws and washer of wooden finish brass polished complete all as specified and directed.
S&F magnet catcher to wooden frame work complete all as specified and directed.
S&F 4mm thick white colour aluminium composite panel (as approved by GE) complete all as specified and directed
S&F 10mm thick toughened glass partition including all fixing items complete all as specified
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, man holes etc and getting out in soft/loose soil complete all as specified and as directed by Engr-in-Charge.
Removing excavated soil to a distance exc.250m but n.exc 500m and depositing where directed.
M&L for Cement concrete in surface channels and drains in PCC 1:2:4 type B2 using 40mm graded stone aggregate complete all as specified and directed
M&L Cement concrete in foundations, filling and mass concrete 1:3:6 type C2 (40mm graded stone aggregate) complete all as specified and directed
M&L 15mm thick plaster on fair faces of brick or concrete surfaces in cement and sand mortar 1:4 finished even and smooth without using extra cement.
M&L for precast cement concrete , 1:2:4 type B1(20mm graded stone aggregate) in landings, cover slabs (for man holes etc.) challah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified. Note:- Reinforcement shall be measured and paid separately. The quoted rate shall be inclusive of cost of formwork.
M&L for hume pipe septic tank 25 users capacity incl AC vent pipe, earth work excavation in soft/loose soil, erecting hume pipe septic tank in position, PCC 1:3:6 and all other accessories required such as vent cowl etc and making good the disturbed surface and removing surplus soil and old u/s septic tank, complete incl connecting to the sewer line etc complete and provide new connections to the new septic tank
S&F 110mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches complete all as specified and directed by Engr-in-Charge.
S&F 75mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches / floor complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) bend any radius 110mm bore complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) bend any radius 75mm bore complete all as specified and directed by Engr-in-Charge.
M&L Surface dressing n.exc 15 cm deep soft/loose soil complete all as specified
M&L for 75 mm thick PCC 1:4:8, Type D-2 using 40 mm graded stone aggregate complete all as specified and directed.
M&L for Hardcore of broken stone of gauge n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface all as specified
M&L for Coarse aggregate for granolithic floors graded from 12.5mm to 4.75mm spreading and levelling in layers n exc. 25 cm thick and well ramming including watering as required
S&F Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 80mm thickness, M-40 Grade with grey cement and pigment complete all as specified and directed .
M&L for chequered colour cement concrete tiles 30x30cmx 25mm thick set jointed grey and pigment and pointed in neat cement slurry in floors/steps including screed bed or bedding layer of mortar 15mm thick in cm 1:4 complete all as specified and directed
Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats (lattice mast)
M&L for preparing of old steel surfaces of any description over 10 cm in width or girth not otherwise described and applying 2 coats of anti-corrosive paint over a coat of epoxy primer upto 36m height all as specified including all necessary scaffolding work & as directed by the Engr-in-Charge.
S&F for rolled mild steel structural steel work in compound girders and stanchions, lattice girders, aerial mast, staging for water tanks etc. incl caps , splices, etc. built-up from two or more beam or channels or angles with plates, including all lattice bars, stiffeners, gusset plates etc. withFe-290(Gde- E-165complete all as specified and directed
S&F for Stairs (framed) including stringers, treads, landing, balusters, hand rails etc. including cleats, brackets, etc. conforming with Fe-290(Gde- E-165) complete all as specified and directed
S&F for rolled mild steel structural steel work in plates, channels, square cut or notched (ordinary and counter sunk) forming holes without any attachment and riveted, bolted or welded attachment conforming with Fe-290(Gde- E-165)complete all as specified and directed
M&L for preparing of new steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of anti-corrosive paint over a coat of epoxy primer at any height all as specified and as directed by the Engr-in-Charge.
M&L for running welding in repairs, the thickness of metal to be welded is 6mm to 9mm
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed
S&F frameless glass door with 10mm thick toughened glass SS connector incl 04in no's SS handle of 300mm long fancy type including embossing the logo of size and design as per requirement etc all as specified and directed by Engineer-in- charge
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, sheet metal encl. with plug & socket etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M&L point wiring with 1.5 Sqmm PVC insulated unsheathed FRLSH multistranded single core copper conductor cable in PVC concealed conduit rigid non metallic ( ISI marked ) fixed concealed on wall /roof except beam, column and RCC roof including chases cutting, modular white cover plate, flush metal box etc incl 1.5 Sqmm PVC insulated copper conductor as earth continuity wire for One light point controlled by one switch complete all as specified and directed.
All as per item No.100 above but for One fan point / exhaust fan point controlled by one switch & regulator complete all as specified and directed.
All as per item No.100 above but for One 5 pin 5 Amps Socket point controlled by one switch on same board complete all as specified and directed.
All as per item No.100 above but for One 5 pin 5 Amps socket point controlled by one switch on independent board complete all as specified and directed.
All as per item No.100 above but with 2.5 Sqmm copper conductor including 2.5 Sqmm copper cable as earth wire for one 6 Pin 16 Amps Socket outlet on independent board complete all as specified and directed.
All as per item No. 100 above but with 4 Sqmm copper conductor including 4.0 Sqmm copper cable on earth wire for sheet metal enclosure complete all as specified and directed.
S&F modular switch 1 way 6 Amps,1 module complete all as specified and directed.
S & F Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specified and directed.
S & F socket modular 6 Amps and 2/3, 2 module complete all as specified and directed.
S & F Modular socket 6 A/16 A - 2/3 pin, 2 module
S&F switch 15 A One way SP modular type.
Taking down existing Light fittings of any type and size and removing to store yard.
S&F surface mounted LED down lighter 2'x2', 120 Lumen/ Watt, 36/40 W 240 Volt all as per specified and directed. Make :- Philips Cat Part No. RC380B LED 30S-6500 G4 L60 W60 PSD OD or Equivalent from list of manufacturers
S&F Tube light fitting 1 x 20 w ,120 Lumen/ Watt, with T 8 LED tube with aluminium Extrusion heat sink for optimum performance with high luminous efficiency and batten pre wired suitable for use with LED tube with concealed accessories complete. including taking down old one complete all as specified and directed. Make:- REGALBATTENT8UPTO1X22WSSBSWH & LED rod CRYSTAL1213T8DSTL20WLED865SGLASS/CG/WIPRO or Equivalent from list of manufacturers
S&F fan regulator electronic step type, modular type, 120 W, 2 module complete all as specified and as directed.
S&F Sheet metal enclosures with socket plug top and MCB' single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 A MCB
Taking down old DBs of any size
S&F Sheet metal enclosure TPN for DB's when MCB's to be used 4 way with 200 amps bus bar double door
S&F Sheet metal enclosure TPN for DB's when MCB's to be used 8 way with 200 amps bus bar double door
S&F SPN sheet metal enclosure for DB 8 ways Double door.
S&F SPN sheet metal enclosure for DB 4 ways Double door.
S&F MCCB 4 pole 2 160 Amps 4 pole, 415 V, adjustable type with breaking capacity 36KA complete all as specified and directed with enclosure.
S&F MCB 'B' Curve 40 Amp SPN ,240 Volts Make L&T Cat Part No. BB20400B all as specified and directed.
S&F MCB 'B' Curve SP 6 To 32 Amp , 240 Volts all as specified and directed. Make:- Schneider Cat Part No. A9N1P06B to A9N1P32B,
S&F ceiling fans complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated complete all as specified. Make :- CG Cat Part -Energion HS BLDC or equivalent Note :-Old exhaust fans shall be deposited in MES store yard
S&F exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified. Make:- Havells turbo force SP or equivalent Note:- Old exhaust fans shall be deposited in MES store yard
Taking down old sub main wiring of any size
M&L sub main wiring with 2 single core 4 Sqmm PVC insulated unsheathed multistranded copper conductor cable 1100 volt grade drawn through and including PVC rigid conduit concealed wiring including necessary PVC conduit specials including chases cutting complete except beam and RCC roof and one run of 4 Sqmm PVC insulated unsheathed single core 1100 volts grade multistranded copper conductor cable as earth continuity conduto9r and connecting with suitable size thimble complete all as specified and as directed. Note:- 02 runs of 4 sqmm size PVC cable , one run of 4 Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length
All as per item No. 127 above but with 2 single core 06 Sqmm PVC insulated copper conductor with 1 run 6 Sqmm copper conductor as earth wire
All as per item No. 127above but with 4 single core 16 Sqmm PVC insulated copper conductor with 2 run 10 Sqmm copper conductor as earth wire
All as per item No.127 above but with 4 single core 25 Sqmm PVC insulated copper conductor with 2 run 16 Sqmm copper conductor as earth wire
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mmx6 mm thick buried directly in ground(earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 mtrs below ground level connected to galvanized iron strip 25 x 4mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron steel all shown in electric plate No.3 ( of SSR Part-i connected to earthing test pit all as specified or indicated including provn of necessary excavation and earth work in any type of soil, PCC pit ,RCC cover and frame, 20 mm bore medium grade watering pipe , water funnel, 40 mm bore GI light grade protection pipe , common salt, charcoal dust, returning, filling in of soil, removal of soil to a distance not exceeding 50 mtr etc including testing on completion complete all as specified and directed. Note:- The quoted rate shall include the cost of removing tiles before starting earthing work and making good the surface to match with the existing finish after completion of earthing and testing.
S&F in repair Building security light made up of pressure die cast housing, more than 110 Lumen/ Watt, with toughened glass and high power LEDs with option of secondary optic with IP 66 protection of 45 Watt Crompton Cat Part No. LSTS-45-CDL-M (or equivalent) including suitable GI bracket of 25 mm dia and fixing arrangement on walls all as specified and directed.
Supply, laying, jointing, connecting & testing in trenches XLPE /PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminium conductor in trenches / ducts/Wall of size 3.5 core 50 Sqmm all as specified and directed :
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire
M&L earth plate electrode 60 cm x 60 cm x 6 mm buried directly in ground to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below normal ground level surrounded from all side by 15 cm of thick and packed layers of charcoal dust and common salt ,filling alternate layers and electrode connected by using GI wire 4 mm dia (max -length of 7.5 mtrs )by means of bolts,nut and washer of GI and providing GI light grade pipe 15 mm dia as protection pipe for GI wire connected main control board / test point and provided with GI pipe of medium grade 20 mm bore for watering and including funnel, wire mesh PCC chamber of 1;3;6 type C1 ,and RCC cover of 1;2;4 type B1 including necessary earth work in any type of soil /strata disposal of soil all as directed and shown in electrical plate No. 3 of SSR part -1. Note:- The quoted rate shall include the cost of removing tiles before starting earthing work and making good the surface to match with the existing finish after completion of earthing and testing.
Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point.
M & L for River sand filling in trenches for cushioning of UG cables punning after filling complete all as specified and as directed. Note: Punned thickness shall only be measured and paid
Supply & laying un-reinforced precast concrete cable cover class LV type 1, flat size 250mm x 150mm x 40 mm all as specified & directed.
S&F in repair recessed mounted 2 feet by 2 feet LED flat panel with high brightness with glare free recessed mounted 36 Watt fittings, 240 Volts, 5700 K, Premium signature series, including all connection where required some copper conductor 1.5 sqmm, complete all as specified and as directed by the Engineer-in-Charge. Make:- Crompton Cat Part No. LCTRI-36-CDL or equivalent model of any manufacturers from the approved list.
Taking down old GI/ CPVC pipe of size 40 mm complete all as specified and as directed.
Taking down old GI/ CPVC pipe of size 20 mm complete all as specified and as directed.
Taking down old GI/ CPVC pipe of size 25 mm complete all as specified and as directed.
Supply and fix in repair on wall/ floor concealed on wall high pressure CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings including all necessary fittings, solvents of size 40 mm dia complete all as specified and directed. Make: Supreme/Eurotech /Astral/SFMC
All as per item No.143 here -in-before but of size 25 mm dia
All as per item No.143 here -in-before but of size 20 mm dia
Taking down old bib tap, stop cock, shower ,pillar tap, sink cock, angle valve, health faucet, angle cock health faucet etc complete all as specified and as directed.
S&F Bib cock , CP quarter turn with flange and aerator, fancy type short body cast copper alloy with crutch or butterfly handle screwed for GI/ CPVC pipe of size 15 mm complete all as specified and as directed by the Engineer-in-charge. Make : Model No F2004151 of Cera or Equivalent
S&F Bib cock, CP quarter turn with flange and aerator, fancy type long nose with wall flange cast copper alloy with crutch or butterfly handle screwed for GI/ CPVC pipe of size 15 mm complete all as specified and as directed by the Engineer-in-charge. Make : Model No F2004152 of Cera or Equivalent
S&F two way bib cock ,quarter turn with flange and aerator of size 15 mm complete all as specified and as directed by the Engineer-in-charge. Make : Model No : F2004163 of Cera or Equivalent
S&F concealed stop cock regular body, Quarter turn with adjustable wall flange chromium plated with CP cup fancy type of size 20mm complete all as specified and as directed by the Engineer-in-charge. Make : Model No: F2002362 of Cera or Equivalent
S&F 15 mm angle valve, half turn with flange, with flange type chromium plated for fixing accessories for CPVC pipe complete specified and as directed by the Engineer-in-charge. Make : Model No: F2004201 of Cera or Equivalent
S&F swivel overhead shower (minimum weight 40 grams) of PTMT any colour with shower arm (minimum weight 40 grams) 15mm size, 195 mm long with bend of 45 degree with flange for fixing with CPVC pipe all as specified and as directed by the Engineer-in-charge. Make : Model No: F7020104 of Cera or Equivalent
Taking down old PVC connection complete all as specified and as directed.
S&F PVC connection pipe 16mm dia (outer 450mm long cold water and taking down old one complete with brass union on both sides to suit 15mm GI pipe complete all as specified and directed by the Engineer-in-charge.
S&F Health faucet ABS body with wall hook and 1 metre SS braided rubber hose pipe , including taking out old one all as specified and directed. Make : Model No: F8030102 of Cera or Equivalent
Taking down old rotational moulded polythene water storage tanks of capacity 1000 litres complete all as specified and as directed.
S&F Rotational moulded polythene water storage tanks(Cylindrical vertical with closed Top) hoisted and fixed in Position all as specified of capacity 1000 litres complete all as specified and as directed.
Taking down old CPVC ball valve of size 20 mm /25 mm complete all as specified and directed.
S&F CPVC Ball Valve of size 25 mm dia suitable for CPVC pipe incl necessary fittings complete all specified and directed.
S&F in repair float valve synthetic(PVC) of size 25 mm dia high pressure with polythene ball of size 6" dia and flynut complete all as specified and directed.
S&F Self closing angle cock pressure for urinal with wall flange and 200 all as per specified and directed. Make : Model No: F9020203 of Cera or Equivalent
Supply, laying, jointing, connecting & testing in trenches / through pipes / fixed on walls XLPE insulated PVC bedded steel strip or wire armoured electric power cable heavy duty 1100 volts grade, stranded aluminium conductor of size 2 core 6 Sqmm incl taking down old complete all as specified and directed.
Supply, laying, jointing, connecting & testing in trenches / through pipes / fixed on walls XLPE insulated PVC bedded steel strip or wire armoured electric power cable heavy duty 1100 volts grade, stranded aluminium conductor of size 2 core 10 Sqmm incl taking down old complete all as specified and directed.
S & F in repair, Sheet Metal enclosure for MCB DB, SPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified.
S & F MCB SPN 32 Amps, 230 Volts, ‘C’ series with all incoming /outgoing connections with proper size of lugs complete all as specified and directed
S & F MCB SP 6 to 32 Amps 240 Volts, 10KA ‘C’ series with all incoming /outgoing connections with proper size of lugs complete all as specified and directed.
S & F integral LED aviation light Die-cast aluminium housing with Red polycarbonate dome for better illumination supper flux 5mm 302 Nos LEDs incorporated with all incoming /outgoing connections with proper size of lugs complete all as specified and directed. Make- Bajaj cat No BGAV 302 LED
M&L in repair air termination single pointed aluminium rod 12mm dia and 300mm long all as specified and directed.
S&F in repair GI strip 25 x 4 mm with protection sleeves, saddles, separator and fixing screws incl all fixing arrangements with hexagonal headed screws complete all as specified and directed.
M&L in repairs for test point terminal block made of gunmetal of size 75x75x25mm drilled and screened including all fixing arrangements with hexagonal headed screws all as specified.
S & F GI cable tray size 100 mm width x 25mm height including fitting and fixtures complete all as specified and directed.
S & F street light TIMER control panel, 40 Amps, 3 pole/230 Volt, astronomical time switch pole/wall mounting made out of 3.15 mm CRCA sheet duly powder coated with locking arrangement, incl internal wiring completed with bypass arrangements. (or as manufactures recommendation and design). Make –Havells, Legrand, L&T.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mmx6 mm thick buried directly in ground(earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 mtrs below ground level connected to galvanized iron strip 32 x 6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron steel all shown in electric plate No.3 ( of SSR Part-i connected to earthing test pit all as specified or indicated including provn of necessary excavation and earth work in any type of soil, PCC pit ,RCC cover and frame, 20 mm bore medium grade watering pipe , water funnel, 40 mm bore GI light grade protection pipe , common salt, charcoal dust, returning, filling in of soil, removal of soil to a distance not exceeding 50 mtr etc including testing on completion complete all as specified and directed. Note:- The quoted rate shall include the cost of removing tiles before starting earthing work and making good the surface to match with the existing finish after completion of earthing and testing.
Supplying and laying Brick well burnt class 'B' as in cover (cable protection) to UG cable, laid dry, flat over the cable laid across the length of the cable and abutting each other with gap between adjacent brick not exc 10mm complete all as specified and directed.
S&F 40 mm bore GI pipe light grade with necessary fittings laid in floor / pillar / walls etc complete all as specified and directed.
Cutting existing/hardstanding of any type by using crow bar chisel unto a depth of 30 cm for laying GI pipe including making good the surface by returning filling, watering ramming in layers with cold mix bitumen, over 200mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
M/s ANTONY THOMAS AND CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .