| Sl No | Description | Qty | Unit | GERESH ELECTRICALS PRIVATE LIMITED L2 | Dinu Electricals L1 |
|---|---|---|---|---|---|
| 1.00 | Site cleaning: The scope of work includes cutting bushes/trees/vegetation over cable trench/cables/concrete supports, removing sand/debris, relocating the wastes and clearing the work site. The area near cable trench/concrete supports (1 meter distance from both side) shall be cleaned. Crane, lifting arrangements, tools, cutting machines, vehicles etc. required for the work shall be arranged by the contractor. The wastes shall be transported to the location specified by the Engineer-in-charge. | 1 | LS | 92,800 ₹92,800 Lowest | 98,000 ₹98,000 |
| 2.00 | Removal of sand/debris in the cable trench for feeder-1: The scope of work includes removal of sand/debris in the cable trench manually, transporting the wastes to the location specified by the Engineer-in-charge. The inside dimensions of existing cable trench for feeder-1 is Width-750mm and Depth-1100mm. The work shall be carried out without causing any damages to the live 11kV power cables and control cables. Crane, lifting arrangements, tools, vehicles etc. required for the work shall be arranged by the contractor. | 280 | M | 235 ₹65,800 Lowest | 240 ₹67,200 |
| 3.00 | Removal of sand/debris in the cable trench for feeder-2: The scope of work includes removal of sand/debris in the cable trench manually, transporting the wastes to the location specified by the Engineer-in-charge. The inside dimensions of existing cable trench for feeder-2 is Width-750mm and Depth-1100mm. The work shall be carried out without causing any damages to the live 11kV power cables and control cables. Crane, lifting arrangements, tools, vehicles etc. required for the work shall be arranged by the contractor. | 280 | M | 235 ₹65,800 Lowest | 240 ₹67,200 |
| 4.00 | Supply of MS angle 50x50x6mm: The scope of work includes supply of M.S. Equal Angle (ISA) of size 50x50x6mm as per IS:2062. | 7,500 | KG | 85 ₹6,37,500 Lowest | 90 ₹6,75,000 |
| 5.00 | Supply of MS angle 65x65x6mm: The scope of work includes supply of M.S. Equal Angle (ISA) of size 65x65x6mm as per IS:2062. | 2,500 | KG | 85 ₹2,12,500 Lowest | 90 ₹2,25,000 |
| 6.00 | Supply of MS channel: The scope of work includes supply of MS Channel (ISMC) of size 150x75mm as per IS:2062. | 1,000 | KG | 85 ₹85,000 Lowest | 90 ₹90,000 |
| 7.00 | Supply of MS plate: The scope of work includes supply of MS plate of Thickness 10mm as per IS:2062. | 1,000 | KG | 85 ₹85,000 Lowest | 90 ₹90,000 |
| 8.00 | Fabrication and installation of supports in cable trench for feeder-1: The scope of work includes fabrication of cable supports using the MS angle supplied vide Sl.no.4 of this work schedule as per the attached annexure-1 and fixing the cable supports in the trench using anchor bolts. Cable supports shall be provided at an interval of 1000mm. Necessary holes (with threads wherever necessary) on the steel sections required for fixing of bolts, nuts etc. for cable clamping and anchor bolting shall be provided. Anchor bolts required for the work shall be arranged by the contractor. Plastering shall be provided on the base of the support. Sand, Cement etc. for plastering shall be arranged by the contractor. All fabricated items shall be painted with two coats of anti-corrosive epoxy paint (grey colour) over two coats of suitable primer. | 280 | NO | 2,100 ₹5,88,000 Lowest | 2,325 ₹6,51,000 |
| 9.00 | Fabrication and installation of supports in cable trench for feeder-2: The scope of work includes fabrication of cable supports using the MS angle supplied vide Sl.no.4 of this work schedule as per the attached annexure-1 and fixing the cable supports in the trench using anchor bolts. Cable supports shall be provided at an interval of 1000mm. Necessary holes (with threads wherever necessary) on the steel sections required for fixing of bolts, nuts etc. for cable clamping and anchor bolting shall be provided. Anchor bolts required for the work shall be arranged by the contractor. Plastering shall be provided on the base of the support. Sand, Cement etc. for plastering shall be arranged by the contractor. All fabricated items shall be painted with two coats of anti-corrosive epoxy paint (grey colour) over two coats of suitable primer. | 280 | NO | 2,100 ₹5,88,000 Lowest | 2,325 ₹6,51,000 |
| 10.00 | Scaffolding for higher elevation work: The scope of work includes providing and fixing double scaffolding system using 40 mm dia M.S. tube 1.5 m center to center, horizontal & vertical joining with cup & lock system including necessary working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The scaffolding system shall be provided on both side of existing box type cable tray. The payment will be made once irrespective of duration of scaffolding. The approximate length of MS cable tray is 250 meter and approximate height is 12 meter. | 1 | LS | 41,76,000 ₹41,76,000 | 24,00,000 ₹24,00,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
6 Aug 2026, 11:00 amClosed
SM(Mat)C
Corporate Materials, PD Administration Building, FACT - Udyogamandal, Kochi, Kerala
Replacement of 11 kV, 3 Core X 400 Sq.mm Power cable from Thermal plant to Central substation in FACT Cochin Division, Ambalamedu, as per tender conditions.
2026_FACT_917675_1
04026/2026-2027/E33870
Open Tender
Miscellaneous Works
Item Rate
150 days
FACT - Cochin Division
Please refer tender documents.
7 documents required · 7 mandatory
₹0
₹1 L
Yes
6 Oct 2026
16 Jul 2026
7 Aug 2026
16 Jul 2026
6 Aug 2026
16 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Site cleaning: The scope of work includes cutting bushes/trees/vegetation over cable trench/cables/concrete supports, removing sand/debris, relocating the wastes and clearing the work site. The area near cable trench/concrete supports (1 meter distance from both side) shall be cleaned. Crane, lifting arrangements, tools, cutting machines, vehicles etc. required for the work shall be arranged by the contractor. The wastes shall be transported to the location specified by the Engineer-in-charge. | 1 | LS | - | - |
| 2 | Removal of sand/debris in the cable trench for feeder-1: The scope of work includes removal of sand/debris in the cable trench manually, transporting the wastes to the location specified by the Engineer-in-charge. The inside dimensions of existing cable trench for feeder-1 is Width-750mm and Depth-1100mm. The work shall be carried out without causing any damages to the live 11kV power cables and control cables. Crane, lifting arrangements, tools, vehicles etc. required for the work shall be arranged by the contractor. | 280 | M | - | - |
| 3 | Removal of sand/debris in the cable trench for feeder-2: The scope of work includes removal of sand/debris in the cable trench manually, transporting the wastes to the location specified by the Engineer-in-charge. The inside dimensions of existing cable trench for feeder-2 is Width-750mm and Depth-1100mm. The work shall be carried out without causing any damages to the live 11kV power cables and control cables. Crane, lifting arrangements, tools, vehicles etc. required for the work shall be arranged by the contractor. | 280 | M | - | - |
| 4 | Supply of MS angle 50x50x6mm: The scope of work includes supply of M.S. Equal Angle (ISA) of size 50x50x6mm as per IS:2062. | 7,500 | KG | - | - |
| 5 | Supply of MS angle 65x65x6mm: The scope of work includes supply of M.S. Equal Angle (ISA) of size 65x65x6mm as per IS:2062. | 2,500 | KG | - | - |
| 6 | Supply of MS channel: The scope of work includes supply of MS Channel (ISMC) of size 150x75mm as per IS:2062. | 1,000 | KG | - | - |
| 7 | Supply of MS plate: The scope of work includes supply of MS plate of Thickness 10mm as per IS:2062. | 1,000 | KG | - | - |
| 8 | Fabrication and installation of supports in cable trench for feeder-1: The scope of work includes fabrication of cable supports using the MS angle supplied vide Sl.no.4 of this work schedule as per the attached annexure-1 and fixing the cable supports in the trench using anchor bolts. Cable supports shall be provided at an interval of 1000mm. Necessary holes (with threads wherever necessary) on the steel sections required for fixing of bolts, nuts etc. for cable clamping and anchor bolting shall be provided. Anchor bolts required for the work shall be arranged by the contractor. Plastering shall be provided on the base of the support. Sand, Cement etc. for plastering shall be arranged by the contractor. All fabricated items shall be painted with two coats of anti-corrosive epoxy paint (grey colour) over two coats of suitable primer. | 280 | NO | - | - |
| 9 | Fabrication and installation of supports in cable trench for feeder-2: The scope of work includes fabrication of cable supports using the MS angle supplied vide Sl.no.4 of this work schedule as per the attached annexure-1 and fixing the cable supports in the trench using anchor bolts. Cable supports shall be provided at an interval of 1000mm. Necessary holes (with threads wherever necessary) on the steel sections required for fixing of bolts, nuts etc. for cable clamping and anchor bolting shall be provided. Anchor bolts required for the work shall be arranged by the contractor. Plastering shall be provided on the base of the support. Sand, Cement etc. for plastering shall be arranged by the contractor. All fabricated items shall be painted with two coats of anti-corrosive epoxy paint (grey colour) over two coats of suitable primer. | 280 | NO | - | - |
| 10 | Scaffolding for higher elevation work: The scope of work includes providing and fixing double scaffolding system using 40 mm dia M.S. tube 1.5 m center to center, horizontal & vertical joining with cup & lock system including necessary working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The scaffolding system shall be provided on both side of existing box type cable tray. The payment will be made once irrespective of duration of scaffolding. The approximate length of MS cable tray is 250 meter and approximate height is 12 meter. | 1 | LS | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tenderdoc.pdf
Tender Documents • 10.62 MB
Unpricedbid.pdf
Tender Documents • 0.10 MB
Compliancestatement.pdf
Tender Documents • 0.28 MB
BOQ_964381.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .