| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC ALAPPUZHA | ALAPPUZHA | KERALA | 686534 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹14.7 L+₹4.0 L (37.1%)Rejected-AOC ALAPPUZHA | ALAPPUZHA | KERALA | 686534 | L2 | Rejected-AOC second Lowest |
| Sl No | Description | Qty | Unit | Angel electricals L1 | VARGHESE ANTONY L2 |
|---|---|---|---|---|---|
| 1.00ELECTRIFICATION | |||||
| 1.00 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | 114 | point | 1,600 ₹1,82,400 | 1,050 ₹1,19,700 Lowest |
| 1.00 | 1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. | 4 | point | 1,700 ₹6,800 | 1,500 ₹6,000 Lowest |
| 1.00 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). | 7 | each | 540 ₹3,780 Lowest | 750 ₹5,250 |
| 1.00 | OD284705/2025-2026:Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. ceiling with with GI string and its accessories neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1x17 w LED fitting with electronic driver, 50000 Burning Hrs, flicker free , efficiency 120 lumen/watt suitable for continuous operation with THD less than 10%, power factor greater than 0.98, RoHS compliant, (Philips Endura Next, model No. BN 308 C LED 20 S L 120 or its equivalent make) | 8 | each | 2,100 ₹16,800 | 750 ₹6,000 Lowest |
| 1.00 | OD284706/2025-2026:Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. ceiling with with factory make clip and its accessoriesand giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1x17 w LED fitting with electronic driver, 50000 Burning Hrs, flicker free , efficiency 120 lumen/watt suitable for continuous operation with THD less than 10%, power factor greater than 0.98, RoHS compliant, (Philips Endura Next, model No. BN 308 C LED 20 S L 120 or its equivalent) | 39 | each | 1,900 ₹74,100 | 500 ₹19,500 Lowest |
| 1.01 | OD283034/2025-2026:Supply and installation , Conveyance, installation, testing and commissioning of Philips Uplight Wall Lamp Comet 30575 wall lantern Suitable for fixing LED B22 Lamp with all accessories without bulb of all types directly on wall and giving connections as required | 2 | each | 550 ₹1,100 Lowest | 650 ₹1,300 |
| 1.01 | OD268747/2025-2026:S u p p l y , c o n v e y a n c e , installation, testing and commissioning of 10W LED mirror lamp complete with all accessories and lamps etc. and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.(K Lite 1597 or equivalent make ) | 3 | each | 1,050 ₹3,150 Lowest | 1,500 ₹4,500 |
| 1.01 | OD267669/2025-2026:Supply Conveyance, installation, testing and commissioning of 6W LED bulk head
fittings suitable for surface and wall mounting output greater than 115 lumen/W 6500
K with IP 66 protection and IK09 protection with power factor greater than 0.95 at
full load, internal surge protection up to 4 KV,and corrosion proof LM6 grade
pressure die cast aluminum body & poly carbonate diffuser cover complete with
THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up
for use on 230 V AC supply. including fixing as required Philips endura or its
equivalent | 4 | each | 1,400 ₹5,600 | 500 ₹2,000 Lowest |
| 1.01 | OD283035/2025-2026:Supply Conveyance, installation, testing and commissioning of 7W LED bulk head fittings suitable for surface and wall mounting output greater than 100lumen/W 6500 K with IP 65 protection and IK08 protection poly carbonate diffuser cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. including fixing as required Philips vistaglow or its equivalent | 6 | each | 959 ₹5,754 | 750 ₹4,500 Lowest |
Tender Value
Refer Docs
EMD Value
₹27,542
Closing Date
7 Feb 2026, 5:00 pmClosed
ASSISTANT EXECUTIVE ENGINEER,
O/o the Assistant Executive Engineer PWD Electrical Sub Division Idukki Painavu
Balance work of Construction of new office block and cell for sub jail Peerumed
2026_PWD_832506_1
PWD/BLDG/TR/23651/2025_6_1_1/1
Open Tender
Electrical Works
Item Rate
90 days
peerumadu
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,760
₹27,542
8 May 2026
31 Jan 2026
9 Feb 2026
31 Jan 2026
7 Feb 2026
31 Jan 2026
ELECTRIFICATION
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
OD284705/2025-2026:Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. ceiling with with GI string and its accessories neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1x17 w LED fitting with electronic driver, 50000 Burning Hrs, flicker free , efficiency 120 lumen/watt suitable for continuous operation with THD less than 10%, power factor greater than 0.98, RoHS compliant, (Philips Endura Next, model No. BN 308 C LED 20 S L 120 or its equivalent make)
OD284706/2025-2026:Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. ceiling with with factory make clip and its accessoriesand giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1x17 w LED fitting with electronic driver, 50000 Burning Hrs, flicker free , efficiency 120 lumen/watt suitable for continuous operation with THD less than 10%, power factor greater than 0.98, RoHS compliant, (Philips Endura Next, model No. BN 308 C LED 20 S L 120 or its equivalent)
OD283034/2025-2026:Supply and installation , Conveyance, installation, testing and commissioning of Philips Uplight Wall Lamp Comet 30575 wall lantern Suitable for fixing LED B22 Lamp with all accessories without bulb of all types directly on wall and giving connections as required
OD268747/2025-2026:S u p p l y , c o n v e y a n c e , installation, testing and commissioning of 10W LED mirror lamp complete with all accessories and lamps etc. and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.(K Lite 1597 or equivalent make )
OD267669/2025-2026:Supply Conveyance, installation, testing and commissioning of 6W LED bulk head fittings suitable for surface and wall mounting output greater than 115 lumen/W 6500 K with IP 66 protection and IK09 protection with power factor greater than 0.95 at full load, internal surge protection up to 4 KV,and corrosion proof LM6 grade pressure die cast aluminum body & poly carbonate diffuser cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. including fixing as required Philips endura or its equivalent
OD283035/2025-2026:Supply Conveyance, installation, testing and commissioning of 7W LED bulk head fittings suitable for surface and wall mounting output greater than 100lumen/W 6500 K with IP 65 protection and IK08 protection poly carbonate diffuser cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. including fixing as required Philips vistaglow or its equivalent
OD267670/2025-2026:Supply and fix E-22/E-27 Type 9W LED bulb 3000 K in Existing angle / straight brass lined skirt type, Bakelite batten holder etc. as required.
90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
19.1:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required:
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
1.41:Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
OD283037/2025-2026:Supply Conveyance, installation , testing and commissioning of exhaust fans (in and out type) of size 225 mm sweep 1350/1400 RPM Exhaust fan in metal frame with metal guard , bird guard including anti corrosive powder coated , working on 230 V A/C single phase A/C existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan as required (almonard or its equivalent)
OD283038/2025-2026:Supply, Conveyance,Testing and Commissioning of 305 mm sweep, 1400 rpm working on 230 V A/C Heavy Duty Exhaust fan in tequivalent)he existing opening using suitable size anchor bolt / Screws etc and giving connection as required.(Crompton or its
90.5.1.4:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Musical bell with bird sound
1.22.3:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.150 mm X 75 mm X 60 mm deep
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
OD284712/2025-2026:Supply, Conveyance,Testing and Commissioning of vertical wall mounting type 5 star rated 3L 3KW Vertical Instant Water Heater (Geyser), copper container with puff insulation and PVC body working on 230 Volt 50 Hz A/C supply , fixing on wall using suitable size anchor bolt / Screws etc and giving connection of water line and electrical supply. (Racold Altroi+ 3L 3KW Vertical Instant Water Heater (Geyser) White) or its equivalent)
OD284713/2025-2026:Supply, Conveyance,Testing and Commissioning of vertical wall mounting type 5 star rated 6 litres Instant Water Heater, 3 KW ,copper container with puff insulation and PVC body working on 230 Volt 50 Hz A/C supply , fixing on wall using suitable size anchor bolt / Screws etc and giving connection of water line and electrical supply. (Make Racold 6 litres Instant Water Heater, Pronto Stylo(491213632) or its equivalent)
OD280916/2025-2026:Supply, Installation, Testing, and Commissioning of a pump set having Head Range: 20-32 m, Discharge Range:22680-10080 LPH, Pipe Size:50mm X40mm, 3-phase motor pump set, etc. as required.AQUATEX, TEXMO make 3 PHASE 3 HP AMH30NI or its equivalent makes
OD280927/2025-2026:Supply and fitting of Barrel nipple GI 25 mm x 9 inch ISI etc as required.
OD280929/2025-2026:Supply and fixing of Hose Collar Steel 50mm using suitable items as required .
OD280930/2025-2026:Supply and fixing 50 mm Hose Clip screw type etc as required.
OD280931/2025-2026:Supply and fixing 50 mm CI Foot Valve etc as required
OD280932/2025-2026:Supply and fixing 50 mm Dutron Kanaflex Hose etc as required
OD280933/2025-2026:Supply and fixing 50 mm MTA PVC supreme PN 16 etc as required.
OD280935/2025-2026:Supply and fitting 50 MM x 25 MM GI TEE ISI etc as required.
OD280982/2025-2026:Supply and providing 50 mm PVC pipe 10 KG , SUPREME or equallant make cutting and joining etc. with required accessories as required.
90.14.28.2:S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor
OD280936/2025-2026:Supply and fitting 50mm SP GI Bend etc as required.
90.6.5.13:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 4.00 sq mm
OD284744/2025-2026:Supplying and fixing 4P sheet steel enclosure on surface/ recess suitable for providing 4P isolator complete with connections, testing and commissioning etc. as required.
9.1.7:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)
90.12.1.13:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 6 sq mm
90.12.7.13:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 6 sq mm with factory made clamp
OD284699/2025-2026: Supply, Installation,Testing and Commissioning of ON GRID Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono perc half cut Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- Solar Photovoltaic Module of capacity 500Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10years and 80% at the end of 25 years. a) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. b) Data Monitoring System complete with accessories. c) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. d) Lightning and surge voltage protection. e) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying &fixing of necessary channel/conduit lugs and other accessories etc. as required.
OD284742/2025-2026:Painting letters or figures of the 2.50 cm, 4 cm or 5 cm height sizes with enamel paint as identification mark to SB, DB, panel board etc as required<br
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1399406.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_1399406.xls
BOQ • 0.35 MB
NIT.pdf
Tender Documents • 0.02 MB
SBD.pdf
Tender Documents • 2.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .