| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.0 LAccepted-AOC | L1 | Accepted-AOC Accepted, lower rate, agreement executed on 16/10/2024 | |
| 2 | L2₹48.2 L+₹6.2 L (14.8%)Rejected-AOC | L2 | Rejected-AOC Higher rate and hence not admitted | |
| 3 | L3₹50.2 L+₹8.2 L (19.6%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹50.3 L+₹8.3 L (19.7%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹50.3 L+₹8.3 L (19.9%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹51.3 L
EMD Value
₹50,000
Closing Date
18 Sept 2024, 3:00 pmClosed
Executive Engineer
P.H Division, Painavu
Estimate is created for laying 100mmGI pipe of 720m and 80mm GI pipe of 3000m from Chinnar to 4th mile and alterations of about 100 house connections have to be carried out.
2024_KWA_690642_1
11/2024-25/EE/PHDN/PNV
Open Tender
Civil Works - Water Works
Item Rate
90 days
Idukki
Please refer Tender documents.
11 documents required · 11 mandatory
₹2,760
₹50,000
26 Oct 2024
10 Sept 2024
19 Sept 2024
10 Sept 2024
18 Sept 2024
10 Sept 2024
Amount
APPENDIX - A - Cost of Materials
18.12.8:Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work80 mm dia nominal bore
OD66554/2024-2025:Supply of 100 mm GI ( m) Pipe
OD75104/2024-2025:Specials for 100 mm GI pipe medium @ 2%
100.98.440:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm.
100.98.494:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.0, Size 100mm.
100.98.493:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.0, Size 80mm.
APPENDIX - B - Working Charges
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
15.2.2:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)
100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
100.12.9:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 100mm diameter nominal bore.
100.31.1.1:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 80mm diameter, Class I.
100.39.2:Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work: 80mm diameter pipe.
100.39.3:Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work: 100mm diameter pipe.
100.31.1.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class I.
100.32.1:Conveying and fixing C. I. Single Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 25mm Single Acting Air Valve.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
100.37.1:Cutting M.S. sheet, pipe and specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete.
100.37.2:Grinding the cut edges / welded portions in M.S. sheet, pipe and specials by grinding machine including all labour and hire charges of tools etc., complete.
100.37.3:Welding M.S. sheet, pipe and special by gas or electric plant for three run welding including cost of welding rod / gas, all labour and hire charges of tools etc., complete.
OD73665/2024-2025:Testing of 100mm GI pipeline with portable water to the required test pressure
OD73667/2024-2025:Testing 80mm GI pipeline with potable water to the required test pressure
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
APPENDIX - C - Alteration of House Connections
100.98.1008:Engaging Coolie.
100.98.1009:Engaging Fitter ( grade 1).
OD74672/2024-2025:Reconnection of 15mm(1/2 inch) house connection with 15mm (1/22 inch) water meter from newly laid 100mm & 80mm GI mains, upto a length of 5m using 20mm (1/2 inch) PE pipe
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
Mohandas K M
Bobby Kurian
SUNNY JAMES
K.O.Jose
Jayanandan
P T JOSHY
Bidder Name
Bobby Kurian
K.O.Jose
P T JOSHY
GIRIDAS K S
Mohandas K M
Jayanandan
SUNNY JAMES
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1074886.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .