| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.2 CrAccepted-AOC | ₹66.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹76.8 CrRejected-AOC B 163 SWARN JAYANTI PURAM GHAZIABAD GHAZIABAD GHAZIABAD GHAZIABAD UTTAR PRADESH 201001 | GHAZIABAD | UTTAR PRADESH | 201001 | ₹76.8 Cr | L2 | Rejected-AOC L2 |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Hard copy of bid not submitted |
Tender Value
₹51.7 Cr
EMD Value
₹1.0 Cr
Closing Date
29 Jan 2024, 5:00 pmClosed
SE, C and P, UPCL
C and P, Urja Bhawan, Kanwali Road,Dehradun
Loss Reduction Work under Revamped Distribution Sector Scheme EDC Tehri Package-C
2023_UPCLC_65679_3
CCP-I/41/2023-2024
Open Tender
Electrical Works
730 days
As per tender conditions
As per tender conditions
6 documents required · 6 mandatory
₹29,500
Executive Engineer (HQ), UPCL
₹1.0 Cr
Urja Bhawan, Kanwali Road,Dehradun
8 Aug 2024
18 Nov 2023
30 Jan 2024
18 Nov 2023
29 Jan 2024
28 Dec 2023
5 Dec 2023
Amount
Replacement of 33 KV Old /Frayed Conductor
Reconductoring of 33 KV line with Covered Dog Conductor
33 KV AL-59 ACS XLPE (160sq mm) Covered Conductor (SS4240813 & SS4240814) EN50397-1:2006 by Electron Beam radiation Process.Including Sag Percentage
33 kV Polymeric Pin Insulator complete
33KV Class Ball and Socket Polymeric tension insulator with Hardware with tracking IPC
IPC (160 sqmm MVCC to 160 sqmm MVCC)
IPC (Bare conductor to 160 sqmm MVCC) for 33 KV CC.
33 KV Insulated Cable Ties.
Supply IPC with Aluminium Bail for Earthing 3 No / Km(33 kv)
33 KV Mid span Jointing Kit Suitable for 240 Sqmm Covered Conductor.
Single pole SP 72 as per annexure -C-36
Steel Tubular Poles 13 m long (STP 13.0 M, 410 MPa , SP-72) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Single pole SP 55 as per annexure -J-21
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
33 KV Insulated Cable Ties.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Stay complete (As per annexure C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of 33 KV line with ACSR Raccoon to Dog Conductor
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
33 kV Polymeric Pin Insulator complete
Additional Pole STP-55 for 33 KV line (As per annexure J-20)
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
33kV Disc fitting for Dog conductor 90 KN B&S type
33 kV Composite Polymer Disc Insulator B & S type
ACSR Dog Conductor with 3 % Sag
Aluminum Binding wire & tape
Jointing Sleeves suitable for ACSR DOG conductor
PG clamp/Wedge type for DOG conductor
Stay complete (As per annexure C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
New 11 KV XLPE Underground Cable
11 KV UG XLPE 3x120 Sq mm Single Ckt.
SINGLE POLE STRUCTURE AS PER Annexure- D 15
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 1.5 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
11 kV Polymer Pin Insulator with Pin complete.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
DOUBLE POLE STRUCTURE AS PER Annexure- D 16
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
11 kV top channel 100x50x6mm 2.2 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
Base Channel (100X50X6) 2.2 mtr. Long with Clamps and fittings as per SBD specs all galvanized.
11 kV Polymer Pin Insulator with Pin complete.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Stays Complete (As Per Annex. F-15 )
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Supply of 11kV (E) 3cx120mm2 XLPE cable (Cable outer sheet colour as per voltage level decided by UPCL)
Supply of HDPE Pipe PE 80/100 PN6 160 mm dia for HT cable (with colour coding of HDPE pipe as approved by UPCL in order to differentiate other voltage cables laid in other pipes) including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends
Supply of Half Cut 200mm Cement Hume Pipe/PCC Slab
CABLE LAYING : Laying of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using conventional excavation method and Laying the cable in Half Cut 200mm Cement Hume Pipe/PCC Slab at the depth of about 1.2 meter as per site requirement & Cable dia including using cable trench pullers (with Line tension Indicator) and provision of cable Labels ,Protectin Tape (Tape Tile) etc. complete in all respect in the form original before digging. (All the required material to be provided by contractor) (As per approved drawing of UPCL )
Laying and Pulling of 11kV (E) 3cx120mm2 XLPE cable (Cable outer sheet colour as per voltage level decided by UPCL) in half cut Hume Pipe/PCC slab.
Making of Trench using conventional excavation method
Laying of HT cable at the depth of about 1.2 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers (with Line tension Indicator) without open excavation in HDPE pipe:including provision of cable Labels
Pulling and Laying of 11kV (E) 3cx120mm2 XLPE cable (Cable outer sheet colour as per voltage level decided by UPCL) by Machine.
Laying of HDPE Pipe 160 mm dia for HT cable at the depth of about 1.2 meter (with colour coding of HDPE pipe as approved by UPCL in order to differentiate other voltage cables laid in other pipes) including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends
Laying of HT cable at the depth of about 1.2 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers (with Line tension Indicator) using conventional excavation method in HDPE pipe:including provision of cable Labels
Pulling and Laying of 11kV (E) 3cx120mm2 XLPE cable (Cable outer sheet colour as per voltage level decided by UPCL) conventional excavation method.
Laying of High -Density Polythylene(HDPE) Pipe 160 mm Dia for 11kV XLPE Cable (colour of HDPE Pipe as per voltage level decided by UPCL) using conventional excavation method with making trench.
Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Underground Road crossing, Nala crossings etc complete in all respects including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends .GI Pipe 150 mm Dia
Pulling and Laying of 11kV (E) 3cx120mm2 XLPE cable (Cable outer sheet colour as per voltage level decided by UPCL) conventional excavation method.
Heat Shrinkable jointing kit for 11 kV 3cx120 Sq. mm. XLPE outdoor
Cable jointing kit straight through for 3cx120 Sq. mm. XLPE Cable
T-Connector (As per Cable current Capacity )
9KV, 5KA Outdoor type Lighting Arrester Polymer.
Supply and installation of Chemical earthing station as per IS 3043 complete with GI earthing electrode ,Bentonite, . Conductor upto test link, test link,earthing chamber, 450x450 mm C.I. Manhole chamber etc.
Supply and Fixing of Cable RCC Route Marker
New 11 KV Line with ACSR Conductor
11 KV New line with Rabbit conductor for Hills SP-23&33
No. of Single pole as per annexure -F-33
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Aluminum paint (Double Coat)
Red Oxide paints
No. of Single pole as per annexure -F-19
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Aluminum paint (Double Coat)
Red Oxide paints
No. of Single Section pole as per annexure -F-20
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV MS channel 100x50x6mm 1.5 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc. Fittings B&S type 45 KN
PG clamp/Wedge type for ACSR Dog/Raccoon / Rabbit
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Aluminum paint (Double Coat)
Red Oxide paints
No. of Double Pole Structure as per annexure -F-35
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
11 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
11 kV Polymer Pin Insulator with Pin complete.
GI Fish Plate 50x8mm for 11 kv DP
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc Fittings B&S type 90/70 KN for ACSR Dog/Raccoon
11 kV Danger Board with GI clamp Bolts & Nuts
PG clamp/Wedge type for ACSR Dog/Raccoon / Rabbit
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
ACSR Rabbit Conductor for Phase with 3% sag.As per annexure-F-26
ACSR Rabbit Conductor with 3 % Sag
Jointing Sleeve for Rabbit Conductor
Guarding of 11 KV line. As per annexure- F-14 A
Guarding channel 100x50x6 mm,2210 mm long with holding clamp, packing piece, nut & bolts etc. all galvanized as per SBD
G.I. Wire No. 6 SWG along the span (For 1 Km. line)
G.I. Wire No. 8 SWG accross the span (For 1 Km. line)
GI Eye Bolt 16mm dia, 236mm long for guarding
G.I. Wire No. 16 SWG for binding
Stay complete (As per Annex F-15)
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
EARTH WIRE 7/16 SWG
11 kV Line : Reconductoring/Augmentation 11 KV line on Existing Pole
Reconductoring of 11 KV line with ACSR Rabbit Conductor
ACSR Rabbit Conductor with 3 % Sag
Additional Pole STP-33 for 11 KV line (As per Annex-J-10A)
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
11 kV Danger Board with clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Replacement of following damaged/wornout accessories
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc. Fittings B&S type 45 KN
11 kV Polymer Pin Insulator with Pin complete.
P.G. clamps for Rabbit conductor
Aluminum Binding wire & tape
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
New 11 KV Bay Extension
New 11 KV Bay with VCB (SCADA Compatible)
11KV, 1000A VCB Switchgear Panel indoor & incoming type complete with CTs of ratio 800/400/5A for incomer & 400/200/5A for outgoing of prescribed specifications & with panel mounted 11KV/110V PT & TVM consisting of
Incomer (SCADA Compatible)
Outgoing (SCADA Compatible)
Bus Coupler (SCADA Compatible)
11 KV GO switch, 630 A all galvanized.
9KV, 5KA Outdoor type Lighting Arrester Polymer.
11 kV Drop out fuse set for Transfoermer With MS Channel 100x50x6mm 1 no. 2.8 mtr. Long,PP , Clamp,Nuts&Bolts all galvanized
11KV, 3Cx300 Sq. mm. XLPE Cable from Transformer to incomer VCB & its laying in trench.
Heat Shrinkable jointing kit for 11 kV 3*300mm2 XLPE outdoor
Cable joining kit for 3Cx300 sq. mm. XLPE Cable Indoor type on Incomer VCB end.
11KV, 3Cx240 sq. mm. XLPE Cable for outgoing 11KV feeders & its laying including fixing of pipe and D/P end.
Cable Jointing Kit for 3Cx240 Sq. mm. XLPE Cable for outgoing Feeder, Indoor Type.
Heat Shrinkable jointing kit for 11 kV 3*240 Sq. mm. XLPE outdoor
LT Voltage Material
LT Control Cable
i) 2x2.5 Sq.mm
ii) 4x2.5 Sq.mm
iii) 10x2.5 Sq.mm
EARTH MAT/CIVIL WORK
G.I. Strip for earthing
a) 65mmx6mm galvanized
b) 45mm x 5 mm galvanized
Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987
MISCELANEOUS
MS (RS Joist, MS Channel, MS angle,Rail as per RESPO drawings enclosed) for Misc. structures for bus bar gantry, LA, CT, PT, PI, Isolators etc. as per drawings & design and site conditions including fabrication, welding, nut & bolt,etc.complete in all respect all galvanized.
ACSR Dog Conductor with 3 % Sag
11KV LINE MISCELLANIOUS MATERIALS
Outgoing 11kV Double Pole structure of SP-23 complete (as per M8)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
Base Channel (100X50X6) 2.2 mtr. Long with Clamps and fittings as per SBD specs all galvanized.
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc Fittings B&S type 90/70 KN for ACSR Dog/Raccoon
11 kV Danger Board with GI clamp Bolts & Nuts
PG clamp/Wedge type for ACSR Dog/Raccoon / Rabbit
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Re-conductoring of bare LT line by LT ABC Replacement of LT Conductor with AB Cable in Theft Prone Areas
Replacement of LT Bare Conductor to AB Cable 3x120+1x95 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (120 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x120+1x95 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 95 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 3x95+1x70 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (95 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x95+1x70 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 70 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 3x25+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (25 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x25+25 Sq.mm.
1x16 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks/Street light.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 3x16+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (16 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x16+1x25 Sq.mm.
1x16 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks/Street light.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 1x16+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (16 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 1x16+1x25 Sq.mm.
1x16 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks/Street light.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of Old /Frayed LT AB Cable
Reconductoring of LT AB Cable 3x120+1x95 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (120 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x120+1x95 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 95 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of LT AB Cable 3x95+1x70 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (95 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x95+1x70 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 70 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of LT AB Cable 3x25+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (25 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x25+25 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of LT AB Cable 3x16+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (16 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x16+1x25 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of LT AB Cable 1x16+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (16 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 1x16+1x25 Sq.mm.
1x16 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks/Street light.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of Damaged Pole's
33KV feeders
STP Pole SP-55
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
11KV feeders
ST POLE SP-33
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
LT Lines
STP Pole SP-21
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Aluminum paint (Double Coat)
Red Oxide paints
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
Damaged Double Poles structures
33 KV Line DPs
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV top channel 125x65x6mm 3.2 mtr. Long with all fixing arrngement, PP, Clamp, bolts & nuts all galvanized.
33 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
33 kV Polymeric Pin Insulator complete
GI Fish Plate 50x8mm for 33 kv DP.
33kV Disc fitting for Panther/Dog/Raccoon/Rabbit conductor 90/70/45 KN B&S type
33 kV Composite Polymer Disc Insulator B & S type
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
PG clamp/Wedge type for HTLS/Panther/Dog / Racoon conductor
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
11 KV Line DPs
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
11 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
11 kV Polymer Pin Insulator with Pin complete.
GI Fish Plate 50x8mm for 11 kv DP
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc Fittings B&S type 90/70 KN for ACSR Dog/Raccoon
11 kV Danger Board with GI clamp Bolts & Nuts
PG clamp/Wedge type for ACSR Dog/Raccoon / Rabbit
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Double Pole, Clamps, insulator Structure and accessories etc. including Loading/Unloading Complete Work.
Sign Board
Sign Board 1 No.in each town 6x4 feet (lengh x breadth) as per SBD.
Sign Board 1 No.in each town 6x4 feet (lengh x breadth) made of MS sheet 14 Gauge(1.6mm thickness) with angle suport of (3"x3",6mm) and height of board 6 feet fromm ground level to bottom of board and length of angle to be buried in the ground 1.50 feet with 1 feet hole pass inside,painting on board ( enamel paint with red oxide base coat)and printing on board (colour printing by Screen printing method)
Description of Work / Item(s)
Amount
Replacement of 33 KV Old /Frayed Conductor
Reconductoring of 33 KV line with Covered Dog Conductor
33 KV AL-59 ACS XLPE (160sq mm) Covered Conductor (SS4240813 & SS4240814) EN50397-1:2006 by Electron Beam radiation Process.Including Sag Percentage
33 kV Polymeric Pin Insulator complete
33KV Class Ball and Socket Polymeric tension insulator with Hardware with tracking IPC
IPC (160 sqmm MVCC to 160 sqmm MVCC)
IPC (Bare conductor to 160 sqmm MVCC) for 33 KV CC.
33 KV Insulated Cable Ties.
Supply IPC with Aluminium Bail for Earthing 3 No / Km(33 kv)
33 KV Mid span Jointing Kit Suitable for 240 Sqmm Covered Conductor.
Single pole SP 72 as per annexure -C-36
Steel Tubular Poles 13 m long (STP 13.0 M, 410 MPa , SP-72) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Single pole SP 55 as per annexure -J-21
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
33 KV Insulated Cable Ties.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Stay complete (As per annexure C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of 33 KV line with ACSR Raccoon to Dog Conductor
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
33 kV Polymeric Pin Insulator complete
Additional Pole STP-55 for 33 KV line (As per annexure J-20)
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
33kV Disc fitting for Dog conductor 90 KN B&S type
33 kV Composite Polymer Disc Insulator B & S type
ACSR Dog Conductor with 3 % Sag
Aluminum Binding wire & tape
Jointing Sleeves suitable for ACSR DOG conductor
PG clamp/Wedge type for DOG conductor
Stay complete (As per annexure C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
New 11 KV XLPE Underground Cable
11 KV UG XLPE 3x120 Sq mm Single Ckt.
SINGLE POLE STRUCTURE AS PER Annexure- D 15
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 1.5 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
11 kV Polymer Pin Insulator with Pin complete.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
DOUBLE POLE STRUCTURE AS PER Annexure- D 16
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
11 kV top channel 100x50x6mm 2.2 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
Base Channel (100X50X6) 2.2 mtr. Long with Clamps and fittings as per SBD specs all galvanized.
11 kV Polymer Pin Insulator with Pin complete.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Stays Complete (As Per Annex. F-15 )
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Supply of 11kV (E) 3cx120mm2 XLPE cable (Cable outer sheet colour as per voltage level decided by UPCL)
Supply of HDPE Pipe PE 80/100 PN6 160 mm dia for HT cable (with colour coding of HDPE pipe as approved by UPCL in order to differentiate other voltage cables laid in other pipes) including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends
Supply of Half Cut 200mm Cement Hume Pipe/PCC Slab
CABLE LAYING : Laying of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using conventional excavation method and Laying the cable in Half Cut 200mm Cement Hume Pipe/PCC Slab at the depth of about 1.2 meter as per site requirement & Cable dia including using cable trench pullers (with Line tension Indicator) and provision of cable Labels ,Protectin Tape (Tape Tile) etc. complete in all respect in the form original before digging. (All the required material to be provided by contractor) (As per approved drawing of UPCL )
Laying and Pulling of 11kV (E) 3cx120mm2 XLPE cable (Cable outer sheet colour as per voltage level decided by UPCL) in half cut Hume Pipe/PCC slab.
Making of Trench using conventional excavation method
Laying of HT cable at the depth of about 1.2 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers (with Line tension Indicator) without open excavation in HDPE pipe:including provision of cable Labels
Pulling and Laying of 11kV (E) 3cx120mm2 XLPE cable (Cable outer sheet colour as per voltage level decided by UPCL) by Machine.
Laying of HDPE Pipe 160 mm dia for HT cable at the depth of about 1.2 meter (with colour coding of HDPE pipe as approved by UPCL in order to differentiate other voltage cables laid in other pipes) including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends
Laying of HT cable at the depth of about 1.2 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers (with Line tension Indicator) using conventional excavation method in HDPE pipe:including provision of cable Labels
Pulling and Laying of 11kV (E) 3cx120mm2 XLPE cable (Cable outer sheet colour as per voltage level decided by UPCL) conventional excavation method.
Laying of High -Density Polythylene(HDPE) Pipe 160 mm Dia for 11kV XLPE Cable (colour of HDPE Pipe as per voltage level decided by UPCL) using conventional excavation method with making trench.
Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Underground Road crossing, Nala crossings etc complete in all respects including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends .GI Pipe 150 mm Dia
Pulling and Laying of 11kV (E) 3cx120mm2 XLPE cable (Cable outer sheet colour as per voltage level decided by UPCL) conventional excavation method.
Heat Shrinkable jointing kit for 11 kV 3cx120 Sq. mm. XLPE outdoor
Cable jointing kit straight through for 3cx120 Sq. mm. XLPE Cable
T-Connector (As per Cable current Capacity )
9KV, 5KA Outdoor type Lighting Arrester Polymer.
Supply and installation of Chemical earthing station as per IS 3043 complete with GI earthing electrode ,Bentonite, . Conductor upto test link, test link,earthing chamber, 450x450 mm C.I. Manhole chamber etc.
Supply and Fixing of Cable RCC Route Marker
New 11 KV Line with ACSR Conductor
11 KV New line with Rabbit conductor for Hills SP-23&33
No. of Single pole as per annexure -F-33
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Aluminum paint (Double Coat)
Red Oxide paints
No. of Single pole as per annexure -F-19
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Aluminum paint (Double Coat)
Red Oxide paints
No. of Single Section pole as per annexure -F-20
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV MS channel 100x50x6mm 1.5 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc. Fittings B&S type 45 KN
PG clamp/Wedge type for ACSR Dog/Raccoon / Rabbit
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Aluminum paint (Double Coat)
Red Oxide paints
No. of Double Pole Structure as per annexure -F-35
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
11 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
11 kV Polymer Pin Insulator with Pin complete.
GI Fish Plate 50x8mm for 11 kv DP
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc Fittings B&S type 90/70 KN for ACSR Dog/Raccoon
11 kV Danger Board with GI clamp Bolts & Nuts
PG clamp/Wedge type for ACSR Dog/Raccoon / Rabbit
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
ACSR Rabbit Conductor for Phase with 3% sag.As per annexure-F-26
ACSR Rabbit Conductor with 3 % Sag
Jointing Sleeve for Rabbit Conductor
Guarding of 11 KV line. As per annexure- F-14 A
Guarding channel 100x50x6 mm,2210 mm long with holding clamp, packing piece, nut & bolts etc. all galvanized as per SBD
G.I. Wire No. 6 SWG along the span (For 1 Km. line)
G.I. Wire No. 8 SWG accross the span (For 1 Km. line)
GI Eye Bolt 16mm dia, 236mm long for guarding
G.I. Wire No. 16 SWG for binding
Stay complete (As per Annex F-15)
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
EARTH WIRE 7/16 SWG
11 kV Line : Reconductoring/Augmentation 11 KV line on Existing Pole
Reconductoring of 11 KV line with ACSR Rabbit Conductor
ACSR Rabbit Conductor with 3 % Sag
Additional Pole STP-33 for 11 KV line (As per Annex-J-10A)
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
11 kV Danger Board with clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Replacement of following damaged/wornout accessories
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc. Fittings B&S type 45 KN
11 kV Polymer Pin Insulator with Pin complete.
P.G. clamps for Rabbit conductor
Aluminum Binding wire & tape
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
New 11 KV Bay Extension
New 11 KV Bay with VCB (SCADA Compatible)
11KV, 1000A VCB Switchgear Panel indoor & incoming type complete with CTs of ratio 800/400/5A for incomer & 400/200/5A for outgoing of prescribed specifications & with panel mounted 11KV/110V PT & TVM consisting of
Incomer (SCADA Compatible)
Outgoing (SCADA Compatible)
Bus Coupler (SCADA Compatible)
11 KV GO switch, 630 A all galvanized.
9KV, 5KA Outdoor type Lighting Arrester Polymer.
11 kV Drop out fuse set for Transfoermer With MS Channel 100x50x6mm 1 no. 2.8 mtr. Long,PP , Clamp,Nuts&Bolts all galvanized
11KV, 3Cx300 Sq. mm. XLPE Cable from Transformer to incomer VCB & its laying in trench.
Heat Shrinkable jointing kit for 11 kV 3*300mm2 XLPE outdoor
Cable joining kit for 3Cx300 sq. mm. XLPE Cable Indoor type on Incomer VCB end.
11KV, 3Cx240 sq. mm. XLPE Cable for outgoing 11KV feeders & its laying including fixing of pipe and D/P end.
Cable Jointing Kit for 3Cx240 Sq. mm. XLPE Cable for outgoing Feeder, Indoor Type.
Heat Shrinkable jointing kit for 11 kV 3*240 Sq. mm. XLPE outdoor
LT Voltage Material
LT Control Cable
i) 2x2.5 Sq.mm
ii) 4x2.5 Sq.mm
iii) 10x2.5 Sq.mm
EARTH MAT/CIVIL WORK
G.I. Strip for earthing
a) 65mmx6mm galvanized
b) 45mm x 5 mm galvanized
Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987
MISCELANEOUS
MS (RS Joist, MS Channel, MS angle,Rail as per RESPO drawings enclosed) for Misc. structures for bus bar gantry, LA, CT, PT, PI, Isolators etc. as per drawings & design and site conditions including fabrication, welding, nut & bolt,etc.complete in all respect all galvanized.
ACSR Dog Conductor with 3 % Sag
11KV LINE MISCELLANIOUS MATERIALS
Outgoing 11kV Double Pole structure of SP-23 complete (as per M8)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
Base Channel (100X50X6) 2.2 mtr. Long with Clamps and fittings as per SBD specs all galvanized.
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc Fittings B&S type 90/70 KN for ACSR Dog/Raccoon
11 kV Danger Board with GI clamp Bolts & Nuts
PG clamp/Wedge type for ACSR Dog/Raccoon / Rabbit
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Re-conductoring of bare LT line by LT ABC Replacement of LT Conductor with AB Cable in Theft Prone Areas
Replacement of LT Bare Conductor to AB Cable 3x120+1x95 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (120 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x120+1x95 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 95 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 3x95+1x70 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (95 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x95+1x70 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 70 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 3x25+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (25 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x25+25 Sq.mm.
1x16 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks/Street light.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 3x16+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (16 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x16+1x25 Sq.mm.
1x16 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks/Street light.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 1x16+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (16 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 1x16+1x25 Sq.mm.
1x16 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks/Street light.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of Old /Frayed LT AB Cable
Reconductoring of LT AB Cable 3x120+1x95 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (120 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x120+1x95 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 95 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of LT AB Cable 3x95+1x70 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (95 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x95+1x70 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 70 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of LT AB Cable 3x25+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (25 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x25+25 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of LT AB Cable 3x16+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (16 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x16+1x25 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of LT AB Cable 1x16+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (16 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 1x16+1x25 Sq.mm.
1x16 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks/Street light.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of Damaged Pole's
33KV feeders
STP Pole SP-55
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
11KV feeders
ST POLE SP-33
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
LT Lines
STP Pole SP-21
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Aluminum paint (Double Coat)
Red Oxide paints
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
Damaged Double Poles structures
33 KV Line DPs
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV top channel 125x65x6mm 3.2 mtr. Long with all fixing arrngement, PP, Clamp, bolts & nuts all galvanized.
33 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
33 kV Polymeric Pin Insulator complete
GI Fish Plate 50x8mm for 33 kv DP.
33kV Disc fitting for Panther/Dog/Raccoon/Rabbit conductor 90/70/45 KN B&S type
33 kV Composite Polymer Disc Insulator B & S type
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
PG clamp/Wedge type for HTLS/Panther/Dog / Racoon conductor
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
11 KV Line DPs
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
11 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
11 kV Polymer Pin Insulator with Pin complete.
GI Fish Plate 50x8mm for 11 kv DP
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc Fittings B&S type 90/70 KN for ACSR Dog/Raccoon
11 kV Danger Board with GI clamp Bolts & Nuts
PG clamp/Wedge type for ACSR Dog/Raccoon / Rabbit
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Double Pole, Clamps, insulator Structure and accessories etc. including Loading/Unloading Complete Work.
Sign Board
Sign Board 1 No.in each town 6x4 feet (lengh x breadth) as per SBD.
Sign Board 1 No.in each town 6x4 feet (lengh x breadth) made of MS sheet 14 Gauge(1.6mm thickness) with angle suport of (3"x3",6mm) and height of board 6 feet fromm ground level to bottom of board and length of angle to be buried in the ground 1.50 feet with 1 feet hole pass inside,painting on board ( enamel paint with red oxide base coat)and printing on board (colour printing by Screen printing method)
Capital Electech Pvt Ltd
Capital Electech Pvt Ltd
Capital Electech Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid