Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAccepted-AOC WARD NO 11 THIRIYA NIZAWAT KHAN BAREILLY | BAREILLY | BAREILLY | L1 | Accepted-AOC BEING 1ST LOWEST | |
| 2 | L2₹32.1 L+₹5.3 L (19.7%)Rejected-Finance THIRIYA NIZAWAT KHAN JAMAMASZID WARD NO 07 BAREILLY 2430021 UP | BAREILLY | UTTAR PRADESH | 243002 | L2 | Rejected-Finance Being 2nd Lowest |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
10 Jun 2023, 6:00 pmClosed
GE EAST BAREILLY
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
REPAIR MAINTENANCE OF INTERNAL ELECTRIFICATION INCLUDING GEYSERS AND OTHER CONNECTED WORKS UNDER GE (EAST) BAREILLY.
2023_MES_593732_1
8254/E8
Open Tender
Civil Works
Item Rate
245 days
BAREILLY
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE EAST BAREILLY
₹72,000
Yes
30 Jun 2023
8 May 2023
12 Jun 2023
8 May 2023
10 Jun 2023
22 May 2023
8 May 2023 - 15 May 2023
Amount
Taking down copper/aluminum point wiring (Light fan, socket or power) complete including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting holders etc, removing materials for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors etc complete all as specified & as directed.
Taking down electric meter and disconnecting, removing to store for keeping in safe custody for refixing etc Complete all as specified & as directed.
Taking down main switch / MCB / DBS including MC BS etc of any size removing for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors etc complete all as specified & as directed.
Taking dowm submainwiring/service cable including earth wire and making good disturbed surfaces to match with the existing surfaces of walls incuding removing of site complete all as specified and directed.
M&L for point wiring with FRLS PVC insulated, un-sheathed, multi stranded copper conductor cable of 1.5sqmm size, 1100 volts, drawn through & including concealed 20 mm rigid non metalic PVC conduit with all accessories fixed on wall/ceiling/truss including FRLS PVC insulated, unsheathed, multi stranded copper conductor cable of 1.5sqmm size as earth continuty conductor connected to common earth dolly including required numbers and size of sunk cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switches, switch sockets, sockets, regulators etc with 3 mm thick hylum laminated sheet cover including cutting Chases pinning in, for concealed conduit wiring and making goods of disturbed surface not exc 15 cm girth complete all as specified and as directed for:- NOTE: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit.
One light point / Fan point / Exhaust point / Bell point controlled by one 5A switch
One 5A flush type switch socket point on same board board
One 5A flush type switch socket point on independent board
All as per Srl item No 5 here in before but One 3 pin socket outlet 15 Amp independent with cable of size 2.5 Sqmm for wiring and earth wire
M&L for point wiring with FRLS PVC insulated, un-sheathed, multi stranded copper conductor cable of 1.5 Sqmm size, 1100 volts, drawn through and including non metalic rigid PVC casing and caping not less than 25mm with all accessories fixed on wall / ceiling / truss including FRLS PVC insulated, unsheathed, multi stranded copper conductor cable of 1.5 Sqmm size as earth continuty conductor connected to common earth dolly including required numbers and size of MS boxes / non metallic rigid PVC Terminal boxes with cover plate in any size fixed on wall for fixing the switches, switch sockets, sockets, regulators etc complete all as specified for:- NOTE: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit.
One light point / Fan point / Exhaust point / Bell point controlled by one 5A switch
One 5A flush type switch socket point on same board board
One 5A flush type switch socket point on independent board
One light point controlled by two way switch.
All as per Srl item No 7 here in before but One 3 pin socket outlet 15 Amp independent with cable of size 2.5 Sqmm for wiring and earth wire
M&L for point wiring with FRLS PVC insulated, un-sheathed, multi stranded copper conductor cable of 1.5sqmm size, 1100volts, drawn through & exisiting rigid non metalic PVC conduit with all accessories fixed on wall/ceiling/truss including FRLS PVC insulated, unsheathed, multi stranded copper conductor cable of 1.5sqmm size as earth continuty conductor connected to common earth dolly including required numbers and size of sunk cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switches with 3 mm thick hylum laminated sheet cover plate in any size fixed on wall for fixing the switches, switch sockets, sockets, regulators etc complete all as specified for:- NOTE: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit.
One light point / Fan point / Exhaust point / Bell point controlled by one 5A switch
One 5A flush type switch socket point on same board board
One 5A flush type switch socket point on independent board
One light point controlled by two way switch.
All as per Srl item No 9 here in before but One 3 pin socket outlet 15 Amp independent with cable of size 2.5 Sqmm for wiring and earth wire
S&F switch piano flush type single pole one way 5 Amps Complete all as specified & as directed.
S&F in repairs Modular switch one way 6 Amp, one module,. Complete all as specified & as directed.
S&F in replacement of switch, piano flush type, single pole, two way, 5/6 Amps complete all as specified and directed.
S&F in repars Switch Piano flush type single pole one way 15 Amps.Complete all as specified & as directed
S&F in repairs Modular Switch one way 16 Amp, one module Complete all as specified & as directed.
S&F in replacement of Bell push, 5/6 Amps, 240 volts SP complete all as specified and directed.
S&F switch Socket combination 2 in 1, 3 pin 5 Amp flush type.Complete all as specified & as directed. make- Havells, Anchor.
S&F in repairs Modular Socket 6 Amp, 2 / 3 pin combined 2 module, Complete all as specified & as directed
S&F switch socket combination 2 in 1, 3 pin 6 Amp and 16 Amps Complete all as specified & as directed
S&F in repairs Modular socket 6A/16A, 2/3 pin combined 2 module. Complete all as specified & as directed.
S & F in replacement of Bell, DINGDONG type, 6 Amps, 240 volts, SP complete all as directed.
S&F Lamp holder ( batten/angle ) PVC/Polycarbonate type with back plate for batten/angle fittings.Complete all as specified & as directed.
S&F in repairs Lamp holder ( batten/angle ) PVC/Polycarbonate type with back plate for batten/angle fittings.Complete all as specified & as directed.
S&F Ceiling rose, PVC/polycarbonate insulated body type, 3 terminal, 240 volts, 5 Amps complete all as specified and directed.
Fixing only old serviceable light fittings any type received from item No-1 above including electric connection & cleaning complete.
Fixing only old serviceable LED Tube light fittings 18/20 Watt, 4' complete received from item No.-1 above including cleaning & connecting up with New 3 core flexible copper conductor cable of suitable size.
S&F in repairs Lamp LED 15Watt 230 Volt complete all as specified and directed.
S&F in repairs Lamp LED 9/10 Watt 230 Volt complete all as specified and directed.
S&F in repairs rechargeable Lamp LED 15Watt 230 Volt complete all as specified and directed.
S&F in repair LED retrofit tubes18/ 20 Watt, 4' Complete all as specified & as directed
S&F in repairs LED Tube light fittings 20 Watt ( T-8 ), 4' builtin electronic driver with THD<10% and lumen efficacy >=115Lm/W complete with retrofit tube including connecting up with 3 core flexible copper conductor cable of suitable size Complete all as specified & as directed.
S&F in repairs LED Tube light fittings 10 Watt ( T-8 ), 2' builtin electronic driver with THD<10% and lumen efficacy >=115Lm/W complete with retrofit tube including connecting up with 3 core flexible copper conductor cable of suitable size Complete all as specified & as directed.
S& F in repairs Noble LED strip light 6 watt IP 20 with LED Driver+ power cord cut-table after 3 LED 50000 burning hours (Amber) Sm for POP complete all as specified and directed
S&F in repairs LED bulk head luminaire hexafit 10 watt LED environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagonal bulk head back lit LED luminaries comprising of high brrightness LED complete all as specified & as directed. Make: C&S/Havells/Bajaj/Phillips/ Crompton as approved by GE.
S&F in repairs LED Ceiling light 9/10Watt THD<10% round surface mounted die cast aluminium housing with frosted diffuser including LED lamp 12 Watt Complete all as specified & as directed. Make: C&S/Havells/Bajaj/Phillips / Crompton as approved by GE.
S&F in repairs Recess mounting LED ultra slim Ceiling light 2'X2', 35/36 Watt THD<10% complete all as specified and directed. Make: C&S/Havells/Bajaj/Phillips / Crompton as approved by GE.
S&F in repairs surface mounting type LED ultra Ceiling light 2'X2', 28 Watt THD<10%complete all as specified and directed. Make: C&S/Havells/Bajaj/Phillips / Crompton as approved by GE.
S&F in repairs surface mounting type LED ultra Ceiling light 1'X1', 18 Watt THD<10%complete all as specified and directed. Make: C&S/Havells/Bajaj/Phillips /Crompton as approved by GE.
S&F in repairs round shape 15 watt surface mounted LED down lighter with white powder coated alu housing with integrated electrinic driver THD<10% 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & as approved by GE.
S&F in repairs round shape 10 watt recessed mounted LED down lighter with white powder coated alu housing with integrated electrinic driver THD<10% 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & as approved by GE.
S&F in repairs LED Wall bracket type CITY-2 fitting 15 Watt complete all as specified. Make: C&S/Havells/Bajaj/Phillips / Crompton or equivalent as approved by GE.
S&F in replacement new generation post top energy saving environment friendly, long aesthetically designed with symmetrical light distribution spun aluminium landscape luminaire with high power LEDs as light source of 20 Watt LED , clear cover light illumination for differnt applications suitable for pole dia 50 mm of complete all as specified and directed
S&F in repairs stepped, (socket/switch type) electronic fan regulator flush type 180 Watt, 240 Volts complete all as specified & as directed. Make- Anchor/Bajaj or equivalent as approved by GE.
Fixing only and connecting electric meter upto 25 Amp(Item received form ser No 2 here in before) complete all as specified and as directed.
Fixing only sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor recieved fron item No 4 above alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor drawn in & including PVC conduit/casing capping complete all as specified & directed.
M&L in repairs sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn in & including PVC conduit complete all as specified & directed.
M&L in repairs sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn in existing conduit all as directed.
M&L in repairs sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn in & including in PVC conduit complete all as specified & directed.
M&L in repairs for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through in & including PVC casing & capping complete all as specified and as directed.
M&L in repairs sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn in PVC conduit all as directed.
M&L in repairs sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn in existing conduit all as directed.
S&F in repairs of 2.8mm thick rectangular plastic laminated sheet cover of size 300 x 250 mm including cutting holes for mounting switches, sockets, fan regulators etc as pre requirement including fixing with sufficient no. of machine screws & washers complete all as specified
S & F in repairs of PVC rectangular block for mounting switches, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover of size 250 X 200 X 50 mm deep complete. ISI marked.
S&F in repairs single pole and neutral enclousers having IP -67 protection with a three pin & earth plug with socket complete and one SP, 20 A , 240 V MCB complete all as specified and directed
S&F in repairs sheet metal enclousers (DBS) when MCBs to be used 4 way, 240 Volts double door single pole & neutral with 200 Amps rated bus bar complete all as specified and as directed.
S&F in repairs sheet metal enclousers (DBS) when MCBs to be used 8 way, 240 Volt, double door single pole & neutral with 200 Amps rated bus bar complete all as specified and as directed.
S&F in repairs sheet metal enclousers (DBS) when MCBs to be used 12 way, 240 V, double door single pole & neutral with 200 Amps rated bus bar complete all as specified & directed.
S&F in repairs sheet metal enclousers (DBS) when MCBs to be used 4 way, 415V, double door tripple pole & neutral with 200 Amps rated bus bar complete all as specified & directed.
S&F in repairs MCB 415V, 10KA, TPN , 63Amps to 100Amp complete all as specified and directed.
S&F sheet metal enclousers (DBS) when MCBs to be used VTPN 4 way double door with 200 Amps rated bus bar with MCCB incommer.
S&F in repairs MCCB 415V, 16KA, 4 Pole , 63-100 Amps complete all as specified and directed.
S&F in repairs MCB single phase and neutral 16A - 63A, 230V 10KA. B' curve type complete all as specified and directed.
Fixing only old serviceable MCBs single phase and neutral 16A-63A, 230V 10KA complete all as specified & as directed. (MCB received from item No-4 here in before).
S&F in repairs MCB SP 6A - 32A, 230V, 10 KA, B' curve type complete all as specified and directed
Fixing only old serviceable MCB SP 6A-32A, 230V. 10KA Complete all as specified & as directed. (MCB received from item No-3 here in before).
S & F in repairs Cable weather proof flat twin core with aluminium conductor multi stranded of size 6 sqmm, 1100 Volts grade complete all as specified and directed.
M&L for earthling complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directrly in ground (earth pit not less than 2.25 mtr deep blow GL with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of vharcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised earth strip 32 x 6 connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 40 mm dia GI pipe light grade for protection of GL earth strip and 20 mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type B1 chamber, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 Mtr, Provision of charcoal and slat complete all as shown in electrical plate No 3 of schedule SSR Part-I. Note : (i) Cost of GI earth strip and GI protection pipe upto 7.5 mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning filling, removing, PCC chamber pit RCC cover, test point etc.
M&L for earth continuity conductor of 32x6 mm galvanised rion stripcomplete all as specified and directed.
Taking down / Disconnecting from position existing defective storage type water heater (Geyser) 25/35/50 Ltrs capacity of any make from the building carefully. Opening for repairing, replacement of defective inner, outer tank, deffective spares, accessories & packing with new glass wool, painting the same complete and reinstalling at its original position with suitable fastners etc, water connection, and electric connection with new 3 core 1.5 sqmm copper cable, testing complete all as specified and directed. [Note:-Repair & replacement of item/ spares, painting works, electric copper cable and PVC connections etc for respective items, shall be measured and paid separately].
M&L for cleaning the surfaces throughly and applying a spray coat of synthetic enamel paint including rewriting MES No. on Geyser of 50/35/25Ltr capacity complete all as specified and directed.
Supply & Fix in repairs steel outer body 50Ltr capacity complete all as specified and directed.
Supply & Fix in repairs steel outer body 25 Ltr capacity complete all as specified and directed.
Supply & Fix in repairs copper inner tank 50 Ltr capacity heavy quality complete all as specified and directed.
Supply & Fix in repairs copper inner tank 25 Ltr capacity heavy quality complete all as specified and directed.
Supply & Fix in replacement new apparatus plate/base heavy duty 18 SWG with rubber gasket suitable for 50 / 35 / 25 Ltr capacity Geysers complete all as specified and directed.
Supply & Fix in repairs Geyser assembly made out of copper for 50 Ltr capacity Geyser as per sample complete all as specified and directed.
Supply & Fix in repairs Geyser assembly made out of copper for 25 Ltr capacity Geyser as per sample complete all as specified and directed.
Supply & Fix repairs pressure release valve with bent to Geyser as per ISI specification complete all as specified & directed.
Supply & Fix in repairs safety valve for Geyser as per ISI specification and directed.
Supply & Fix in repairs Geyser element 2.0 KW push type / thread type / dual clip type with rubber gasket suitable for Geyser of any size complete all as specified and directed. Make:- Bajaj / Recold or equivalent as approved by GE.
All as per Srl item No 80 here in before but 1.5KW
All as per Srl item No 80 here in before but 1.5KW with thermostate pocket complete all as specified and directed
All as per Srl item No 80 here in before but 1.5KW coiled type with porceline complete all as specified and directed
Supply & Fix in repairs thermostate switch (ISI Marked) suitable for Geyser 25/35/50 Ltr capacity, adjustable 0 degree to 80 degree centigrade and acting at 70 degree centigrade complete all as specified and directed
Supply & Fix in repairs new indicator lamp square type/round type, red/green colour for Geyser of any capacity complete all as specified and directed.
Repairs on existing inner copper tank by using brazing to make leak proof not exceeding 15 cm in length complete all as specified and directed.
Repairs on existing copper Geyser assembly by using brazing to make leak proof not exceeding 12 cm in length complete all as specified and directed. (NOTE for item No. 70 to 87:- Make of Geyser aceessories shall be as per existing approved brand like Bajaj / Recold / Hevells / Philips / Crompton as approved by Engneer in Charge.)
Supply & Fix in repairs new PVC connection 15mm dia size of length 300mm long superior quality suitable to connect GI pipe 15mm dia to hot water outlet/cold water inlet of Geyser with brass adopter complete all as specified and directed. Make;- Prayag or equivalent as approved by GE.
Supply & Fix in repairs new PVC connection 15mm dia size of length 450mm long superior quality suitable to connect GI pipe 15mm dia to hot water outlet / cold water inlet of Geyser with brass adopter complete all as specified and directed. Make;- Prayag or equivalent as approved by GE.
S&Fix in repairs of sheet metal enclousers single pole & neutral with a two pin and earth plug and socket complete with double pole MCB 20/32 A, 240 Volt complete all as specified and directed. Make:- Havells, HPL or equivalent as approved by GE.
S&F in repairs 3 pin 16 A plug top 230 Volts complete all as specified and directed.
Supply & fix in repairs PVC insulated sheathed flexible multistranded copper conductor cable 3 core 1.5 sqmm ,1100Volts grade complete all as specified and directed.
Supply & Fix in repairs Bib taps chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule of size 15mm bore complete all as specified and directed.
Supply & Fix in repairs Stop valve chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule of size 15mm bore complete all as specified and directed.
Supply & fix PVC insulated sheathed flexible multistranded copper conductor cable 3 core, 1.0 sqmm, 1100 Volts grade complete all as specified and directed.
S&F in repairs GI bracket made out from GI pipe 25/32mm dia, 1.20 m long fixed on wall with and including nut, bolts and GI clamps of size 25x4mm as required & including painting etc complete all as specified & directed.
S&F in repairs all in one solar LED security light 15 W made out of high efficiency , miamo crystalline soloar PV module , lithim ferro phosphate battery with inbuild BMS technilogy , high efficacy LED, MPPT solar charge controller and aluminium extruded body and specailly progrmmed to automatically controlled the dimming and brightness of light which increase the backup time with minimum 10 hrs back up complete IP 67 protection including electric connections etc complete all as specified & directed.
S&F in repairs new generation LED building security light fitting 25 Watt 230 Volts AC out door type energy saving and envrionmental friendly long life LED street light made out of with high pressure die cast aluminium housing with high efficiency LED asc lighting source and lens embeded PC cover having bottom opening seperate driver component with IP 66 protection and impact resistance of IK08 including electric conection complete all as specified & directed.
S S ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .