Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹43.2 CrAccepted-AOC | ₹43.2 Cr | L-1 | Accepted-AOC Lowest amount arrived after deducting discount on freak high rate |
| 2 | L-2₹45.9 CrRejected-Finance | ₹45.9 Cr | L-2 | Rejected-Finance Other than lowest quoted Bidder |
| 3 | L-3₹46.3 CrRejected-Finance | ₹46.3 Cr | L-3 | Rejected-Finance Other than lowest quoted Bidder |
| 4 | L-4₹46.5 CrRejected-Finance | ₹46.5 Cr | L-4 | Rejected-Finance Other than lowest quoted Bidder |
| 5 | L-5₹46.6 CrRejected-Finance F 18 ANSAL COMPLEX OPP JWALA HARI MARKET PASCHIM VIHAR NEW DELHI 110063 | NEW DELHI | WEST DELHI | DELHI | 110063 | ₹46.6 Cr | L-5 | Rejected-Finance Other than lowest quoted Bidder |
Tender Value
₹42.9 Cr
EMD Value
₹15 L
Closing Date
3 Nov 2020, 6:00 pmClosed
Chief Engineer Navy Visakhapatnam
HQ CE(Navy), MES Station Road, Visakhapatnam 530 004
Provision of Deficient In Living Accommodation for Sailors at visakhapatnam
2020_MES_362193_1
CE (NAVY)/VIZ/TOKEN/02 of 2020-21
Open Tender
Civil Works
780 days
Visakhapatnam
As per NIT
9 documents required · 9 mandatory
₹3,000
Garrison Engineer (P) (N)
₹15 L
Yes
Visakhapatnam
26 Dec 2020
20 Jul 2020
4 Nov 2020
20 Jul 2020
3 Nov 2020
27 Oct 2020
3 Aug 2020
Amount
NOTE : Schedule "A" Part I to Part XV are prepriced by MES. Bidders shall insert their lumpsum amount in Green coloured field under col-6 only
Lumpsum price worked out by the contractor for "Buildings & Structures", as listed in Schedule "A" Part – I on Serial Page No. 31[R].
Lumpsum price worked out by the contractor for " Site Clearance / Area Development / Earthwork Excavation", as listed in Schedule "A" Part – II on Serial Page No. 33[R].
Lumpsum price worked out by the contractor for " Pile Foundation", as listed in Schedule "A" Part – III on Serial Page No. 34.
Lumpsum price worked out by the contractor for "Road / Path / Culvert", as listed in Schedule "A" Part – IV on Serial Page No. 36[R].
Lumpsum price worked out by the contractor for "Area Drainage", as listed in Schedule "A" Part – V on Serial Page No. 37.
Lumpsum price worked out by the contractor for "Sewage Disposal", as listed in Schedule "A" Part – VI on Serial Page No. 39[R].
Lumpsum price worked out by the contractor for "Compound Wall / Gate", as listed in Schedule "A" Part – VII on Serial Page No. 41[R].
Lumpsum price worked out by the contractor for "External Electrification", as listed in Schedule "A" Part – VIII on Serial Page No. 43.
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – IX on Serial Page No. 45.
Lumpsum price worked out by the contractor for "INTERNAL Electrification", as listed in Schedule "A" Part – X on Serial Page No. 46[R].
Lumpsum price worked out by the contractor for "Solar Water Heater", as listed in Schedule "A" Part – XI on Serial Page No. 47.
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part – XII on Serial Page No. 48[R].
Lumpsum price worked out by the contractor for "Fire Fighting system", as listed in Schedule "A" Part – XIII on Serial Page No. 51.
Lumpsum price worked out by the contractor for "Lightining Protection", as listed in Schedule "A" Part – XIV on Serial Page No. 52.
Lumpsum price worked out by the contractor for "water Coolers & Deep Freezer", as listed in Schedule "A" Part – XV on Serial Page No. 53.
Lumpsum price worked out by the contractor for "DG Set", as listed in Schedule "A" Part –XVI, Serial Item No. 1 [To be Quoted by the Tenderer] [For detailed description of item refer Serial Page No. 54 to 56] Note: This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Column 5 signifies this fact only.
Lumpsum price worked out by the contractor for "Lift of capacity 13 passenger lift (G+11) (884 Kgs)", as listed in Schedule "A" Part –XVII, Serial Item No. 1 [To be Quoted by the Tenderer] [For detailed description of item refer Serial Page No. 57 to 58] Note: This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Column 5 signifies this fact only.
Lumpsum price worked out by the contractor for "lift of capacity 08 passenger lift (G+11) (544 Kgs)", as listed in Schedule "A" Part –XVII, Serial Item No. 2 [To be Quoted by the Tenderer] [For detailed description of item refer Serial Page No. 57 to 58] Note: This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Column 5 signifies this fact only.
Schedule "A" Part - XVIII [Miscellaneous Items]
Boring for bored cast–in–situ piles 450mm dia in any type of soil/Soft disintegrated rock except hard rock and getting out and disposal of spoil to a distance not exceeding 50 metres using Rotary drilling method by Hydraulic Rotary Rig by DMC method complete all as specified and directed.
Boring for bored cast–in–situ piles 450mm dia in hard rock and getting out and disposal of spoil to a distance not exceeding 50 metres using Hydraulic Rotary Rig by DMC method complete all as specified and directed.
Carrying out Initial Load Test on 450mm dia bored cast–in–situ piles as per IS – 2911 [Part – IV] complete all as specified and as directed.
Carrying out Lateral Load Test on 450mm dia bored cast–in–situ piles as per IS – 2911 [Part – IV] complete all as specified and as directed.
Carrying out Pullout Test on 450mm dia bored cast–in–situ piles as per IS – 2911 [Part – IV] complete all as specified and as directed.
Carrying out Routine Load Test on 450mm dia bored cast–in–situ piles as per IS – 2911 [Part – IV] complete all as specified and as directed.
Carrying out Low Strain Integrity Test on cast–in–situ piles of 450mm dia including analysing the results as per IS – 14893 & ASTM D 5882 complete all as specified and as directed.
Chipping out Pile up to cut off level including disposal up to a distance of 50m complete all as specified and as directed.
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 240 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete. [Transformer to main FPB]
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 120 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete. [Main FPB to Lt bldg panel]
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 95 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete. [Main FPB to DG panel]
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 70 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete. [Main FPB to DG panel]
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 50 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete. [DG panel to FF Room]
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 35 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete. [DG panel to Lift]
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 4 Core, 10 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete. [For street light, Fire Fighting]
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 2Core, 6 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground HT cable, ISI marked with aluminium stranded conductor 11000 Volt grade of size 3 Core, 120 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
Cable jointing kit for 11KV grade cable for out door termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sq.mm complete all as specified and as directed.
GI cable tray with cover for fixing XLPE cables from duty room to terrace for siren and at various places to accommodate the cables for MCBs, Panel etc of size not less than 75X38mm with necessary bends, angles, supports for fixing etc complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 6 KGF/Sq.cm working pressure complete all as specified and as directed.
Compact type Timer Panel of capacity 6KW including of Power contactor of 32A TP, MCB 40 Amps TP and Digital Timer switch 415V, steel encloser allas directed . Make: Havell's Ca no. IHXTS03060 or Equivalent in other makes specified in PS.
Supply, fix and testing of Loop in Loop Out box of FRP made with IP 65 protection of thermoplatic circuit breaker boxes with metric knockouts for cable entry and exit, combiclimate Cable Glands of IP66/IP67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10KA, C Curve overload and short Circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands etc all as specified and directed.
Supplying, Installing, Connecting, Commissioning and Testing of Transformer, Step Down, outdoor Type, Floor or Platform Mounted complete with standard fittings, 11 KV / 433 V OCT (+7.50% to 7.5% @ 2.5)[at No load], AC, 3 Phase, 50 Hz, of 160 KVA capacity, Double Copper Wound, Oil immersed, CRGO Core type Naturally cooled, Built-up with class "A" insulation, having Primary Voltage [HT] 11 KV and Secondary Voltage [LT] of 433 Volts, Delta connected on 11 KV Side & Star connected on 433 Volts side, designed & constructed with particular reference to Tropical Condition, conforming to IS – 1180(Part1)-2014 with energy effiency of "Level2" and equivalent ICE 62270 Radiators shall be hot dip galvanised (HDG) to avoid corrosion with latest amendment complete all as specified and as directed and comprising of the following Specification and Fittings: Continuous Rating : 160 KVA No- Load Voltage Ratio : 11 KV / 433 V Tapping on HV [%] : ± 7.5, ± 5,± 2.5 Phase & Frequency : 3 Phase & 50 Hz Connection : Delta Star Vector Group : DYN 11 Cooling : ONAN Type : Outdoor (a) Lifting lugs/hooks for transformer and tank (b) Earthing terminal rating and diagram plate (c) Air release device (d) Oil filling inlet pipe with plug (e) Drain outlet pipe with brass gate valve with dummy plug (f) Conservator with level gauge (g) Silica gel breather (h) First oil fill up the recommended level by manufacturer with new oil confirming to IS 335 (j) Type of connecting arrangement: Cable termination boxes on both HT and LT side (k) Temperature rise over an ambient of 50degree centigrade maximum (l) All Necessary arrangements with devices for measuring the temperatures of core, winding and oil. (m) In addition to the above all standard fittings shall be provided as per IS norms. Note: The cost of necessary foundation shall be measured and paid separately.
Supply, install, testing and commissioning of Monoblock pump set with minimum rating as 10HP, 70m head, 5.1LPS with delivery of size 80mm bore, 4 pole, 415Volts, 50Hz, AC 3 phase supply, electric driven, inclusive of air valve at delivery, pressure gauge along with cabling by XLPE copper cables from starter to Pump set with cable tray and PCC foundation all as specified and directed.
LED street light Luminaire 70/72 Watts, comprising of epoxy powder coated, Pressure die cast aluminium housing enclosed with glass cover in frame all as per Bajaj Cat No. BRTFG72WLED or equivalent in other makes specified, with suitable size of bracket, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete including installation and testing complete all as specified and directed.
Supply, install, test and commissioning of Power Control panel Indoor type, LT 415 volts 3 phase 100Amps 4 wire made out of 2 mm thick FRP coated CRCA sheet steel dust and vemin proof Cubical pedestal type with front and rear operated doors hinges and cable glands, lugs, danger notice plate consisting of chamber with tinned Aluminium busbar of suitable capacity for phase and neutral with necessary tinned copper strip connections supported by epoxy insulators for incoming and outgoing duly powder coat painted including locking arrangements as per IS:8623 with necessary internal electric connections with CPRI test and with the following complete all as specified and as directed: [Pump House Panel] Incoming- LT 440 volts 3 Phase, 4 wire 50 cycles, Adjustable type MCCB Capacity 32 Amp, 25kA, with overload protection, no-volt thermal based release 4 pole - 01 Nos Outgoings a) TPN MCB C-Curve, 32 Amps, 50Hz, 240/415 Volts - 03 Nos (02 for Pumps+01 Spare) b)TPN MCB C-Curve, 16 Amps, 50Hz, 240/415 Volts - 01 No (Pump house Bldg) c)Automatic Star Delta Starter for 3 phase pumpset upto capacity 10HP - 02 Nos d) LED Indicating Lamps for ech phase with colour code Red Yellow Blue for R, Y and B Phases
Supply, install, test and commissioning of LT Panel board made out of CRCA sheet 3.15mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, Danger Notice plate, Strickering of Switcher gear about termination of switch gear, and the nuts/bolts etc used are to be made of rust proof material including as per IS:8623 Aluminium bus bar of 400Amps rating with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50HZ 415V, 400A capacity complete with powder coating, necessary internal electric connection as required with CPRI test and with the following complete all as specified and as directed:[Near Transformer] Incoming- LT 440 Volts 3 phase, 4 wire 50 cycles, 50KA, Adjustable type MCCB of 200 Amps rated complete with microprocessor released and display type relays- 01 Nos Outgoings a) LT 440 Volts 3 phase, 4 wire 50 cycles, 36KA, Adjustable type MCCB of 160 Amps rated complete with microprocessor released and display type relays - 02 Nos (01 for Building load+01 Spare) b)LT 440 Volts 3 phase, 4 wire 50 cycles,36KA, Adjustable type MCCB of 125 Amps rated complete with microprocessor released and display type relays - 02 Nos (01 for DG set AMF Panel+01 Spare) c) LED Indicating Lamps for ech phase with colour code Red Yellow Blue for R, Y and B Phases d) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, THD along with connected CTs Make: Schinder / L&T
Supply, install, test and commissioning of LT Panel board made out of CRCA sheet 3.15mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, Danger Notice plate, Strickering of Switcher gear about termination of switch gear, and the nuts/bolts etc used are to be made of rust proof material including as per IS:8623 Aluminium bus bar of 400Amps rating with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50HZ 415V, 400A capacity complete with powder coating, necessary internal electric connection as required with CPRI test and with the following complete all as specified and as directed:[LT panel near Bldg] Incoming- LT 440 Volts 3 phase, 4 wire 50 cycles, 36KA, Adjustable type MCCB of 160 Amps rated complete with microprocessor released and display type relays- 01 Nos Outgoings a) LT 440 Volts 3 phase, 4 wire 50 cycles, 36KA, Adjustable type MCCB of 125 Amps rated complete with microprocessor released and display type relays - 02 Nos (01 for Building TPN DB+01 Spare) b)LT 440 Volts 3 phase, 4 wire 50 cycles,10KA, Adjustable type MCB TPN of 16 Amps - 02 Nos (01 for Street light+01 Spare) c) LED Indicating Lamps for ech phase with colour code Red Yellow Blue for R, Y and B Phases d) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, THD along with connected CTs Make: Schinder / L&T
Supply, install, test and commissioning of LT Panel board made out of CRCA sheet 3.15mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, Danger Notice plate, Strickering of Switcher gear about termination of switch gear, and the nuts/bolts etc used are to be made of rust proof material including as per IS:8623 Aluminium bus bar of 400Amps rating with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50HZ 415V, 400A capacity complete with powder coating, necessary internal electric connection as required with CPRI test and with the following complete all as specified and as directed:[LT panel near Bldg for DG supply] Incoming- LT 440 Volts 3 phase, 4 wire 50 cycles, 36KA, Adjustable type MCCB of 125 Amps rated complete with microprocessor released and display type relays- 01 Nos Outgoings a) LT 440 Volts 3 phase, 4 wire 50 cycles, 36KA, Adjustable type MCCB of 100 Amps rated complete with microprocessor released and display type relays - 02 Nos (01 for Fire Fighting panel+01 Spare) b) LT 440 Volts 3 phase, 4 wire 50 cycles, 25KA, Adjustable type MCCB of 32 Amps rated complete with overload protection, no-volt thermal based release - 06 Nos (01 for each lift (04 Nos)+ 01 for fresh water pump panel +01 Spare) c)LT 440 Volts 3 phase, 4 wire 50 cycles,10KA, Adjustable type MCB TPN of 16 Amps - 01 Nos (01 for common space Bldg security lights) c) LED Indicating Lamps for ech phase with colour code Red Yellow Blue for R, Y and B Phases d) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, THD along with connected CTs Make: Schinder / L&T
Supply, install, test and commissioning of LT Panel board made out of CRCA sheet 2mm thick indoor Pedestal type PLC Based control, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, Danger Notice plate, Strickering of Switcher gear about loadtermination, cable connector located in cable chamber terminated for Switchergear/Starter, Timer switch for contolling Bldg Security lights and the nuts/bolts etc used are to be made of rust proof material including as per IS:8623 Aluminium bus bar of 400Amps rating with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50HZ 415V, 400A capacity complete with powder coating, necessary internal electric connection as required with CPRI test and with the following complete all as specified and as directed:[LT panel near Bldg for DG supply] Incoming- LT 440 Volts 3 phase, 4 wire 50 cycles, 36KA, MCCB of 100 Amps rated complete with microprocessor released and display type relays- 01 Nos Outgoings a) LT 440 Volts 3 phase, 4 wire 50 cycles, 36KA, Adjustable type MCCB of 100 Amps rated complete with microprocessor released and display type relays - 01 No (01 for Fire pump) b) LT 440 Volts 3 phase, 4 wire 50 cycles, 36KA, Adjustable type MCCB of 16 Amps rated complete with microprocessor released and display type relays - 03 Nos (01 for Jockey pump+ 01 for Booster pump +01 Spare) c)Star Delta Starter 75 HP-01 No. d)Star Delta Starter 5 HP-02 No. (01 No for Jockey pump+ 01 for Booster pump) c) LED Indicating Lamps for ech phase with colour code Red Yellow Blue for R, Y and B Phases d) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, THD along with connected CTs for measure of 300AMake: Schinder / L&T
Supply,install and testing of Refrigerator, electric driven (Single Phase), capacity 360 litres BEE 5 Star rated, double door all as specified and directed.
Voltage stabilizer of capacity 2.0 KVA for automatic operation , single phase, naturally air cooled indoor type and designed for input varaition between 170V to 250 V and output voltage stabilised at 230 V with accuracy of (+/-) 2.5% complete all as directed.
Voltage stabilizer of capacity 1.0 KVA for automatic operation , single phase, naturally air cooled indoor type and designed for input varaition between 170V to 250 V and output voltage stabilised at 230 V with accuracy of (+/-) 2.5% complete all as directed.
Supply and fixing water geyser 25 Liters storage/heating capacity, 5 Star rating, with automatic on/off switch, absolute temprature range knob, heat indicator and other safety devices single phase, 50Hz, 230Volts with and including inlet and outlet PVC connections pipes and accessories for hot water and cold water complete all as specified and directed.
Supply and fix DOL Starter for Siren set upto capacity of 7.5HP complete all as specified.
Supply, fix and testing CI FOOT VALVE conforming to IS 4038, complete of size 150mm dia all as specified and directed.
Supply, fix and testing CI FOOT VALVE conforming to IS 4038, complete of size 100mm dia all as specified and directed.
Construction of Valve Chamber of size 750 X 750 X 750 mm , with 50mm thick PCC 1:5:10, Type E2, using 40mm graded aggregate for foundation, 200 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:6, 100 mm thick PCC, 1:3:6, Type C1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick internally externally up to 50mm below GL including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified.
Cutting the existing steel tubing line and inserting Tee 120x120x80 mm dia and 80X80X80mm with collars and required specials for tapingincluding necessary earth work excavation complete all as specified
Ductile Iron Pressure Pipe, 150 mm bore, Centrifugally Cast [Spun], Class "K-9" with double flanged conforming to IS - 8329 in standard lengths including necessary fittings such as tees, elbows, bends, reducers, taper pieces including testing and commissioning complete all as specified and as directed. Note: DI specials will be measured and paid separately.
Ductile iron fittings such as Bends, Tapers, Tee pieces, single & double branch any type and angle/radius and straight connecting pieces upto 300mm dia complete all as specified and as directed.
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32X6 mm GI earth strip[Earth Lead] and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
ARBORICULTURE : Best quality Bermuda carpet grass by dibbling process covering 600X600mm to this area for dibbling and covering with red earth organic manure, vermi compost, polydol dust, neem cake and organic manure [Cow dung] complete all as directed by Engineer-in-Charge. Note:- [i] Supply only red soil with manure & vermi compost [As per the area of grass ] shall be measured and paid seperately. However, labour element for filling and watering shall be included in the rate quoted.
Supply and planting of Ashoka plant including preparation of ground upto 30 cm deep and filling soft soil, Cow dung and watering etc complete all as directed by Engineer-in-Charge.
Supply and planting of Royal palm tree including preparation of ground upto 30 cm deep and filling soft soil, Cow dung and watering etc complete all as directed by Engineer-in-Charge.
Supply and planting of Gulmohar [ Hybrid] plant including preparation of ground upto 30 cm deep and filling soft soil, Cow dung and watering etc complete all as directed by Engineer-in-Charge.
Supply and planting of Bougan Vilea tree including preparation of ground upto 30 cm deep and filling soft soil, Cow dung and watering etc complete all as directed by Engineer-in-Charge. Notefor Item Nos. 64 to 67:- [i] Supply only red soil with manure & vermi compost [As per the area of pit ] shall be measured and paid seperately. However, labour element for filling and watering shall be included in the rate quoted.
Supply only approved loose soil best quality for plantation complete all as directed.
Supply only approved Vermi post compost of best quality for plantation weighing each bag of 50 KG complete all as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified. Note for Item No. 70 to 73: Cutting chases and making good surfaces shall be included in the unit rate.
All as per Serial Item No. 70 above but controlled by two two way switches complete all as specified.
All as per Serial Item No. 70 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
All as per Serial Item No. 70 above but one 3 Pin Switch Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Cable as Earth Continuity Conductor.
Point Wiring for flame proof fixtures /Fixtures complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including stove enamelled steel metallic conduit and metal conduit accessories, medium grade, ISI marked including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and Flame proof Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point controlled by One Switch complete all as specified. Note: Cutting chases and making good surfaces shall be included in the unit rate.
Energy efficient LED light fitting with tube minimum 1X20 watt ,230V surface mounted LED batten type with extruded aluminium/CRCA housing and robust constrution with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size complete as per makes HALONIX cat. No. HLB-03-20-CW-AL or equivalent in Philips / Surya Roshni Ltd/ Wipro /GE/Havells and as approved. Note: Light fitting shall be of PF>0.90
Energy efficient LED light fitting with tube minimum 1x40 watt ,230V for trunking based solution for large open area with high ceiling with extruded aluminium/CRCA housing and robust construction with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size complete as per makes HALONIX cat. No. HLL-P02-40-CW or equivalent in Philips / Surya Roshni Ltd/ Wipro /GE/Havells and as approved. Note: Light fitting shall be of PF>0.90
Energy efficient LED ceiling light fitting minimum 08 watt ,230V Integral round shape, surface mounted with necessary diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size complete as per makes HALONIX cat. No. HLDLR-R06-08-CW or equivalent in Philips / Surya Roshni Ltd/ Wipro /GE/Havells and as approved. Note: Light fitting shall be of PF>0.90
Energy efficient LED light fitting with minimum 36 watt ,230V , size 2'X2' ultra slim ceiling light recessed mounting type with and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete as per makes HALONIX cat. No. HLFPU22-02-36-CW or equivalent in Philips / Surya Roshni Ltd/ Wipro /GE/Havells and as approved. Note: Light fitting shall be of PF>0.90
Energy efficient LED mirror light fitting with tube minimum 1X10 watt ,230V surface mounted LED batten type with extruded aluminium/CRCA housing and robust constrution with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size complete as per makes HALONIX cat. No. HLB-03-10-CW-AL or equivalent in Philips / Surya Roshni Ltd/ Wipro /GE/Havells and as approved. Note: Light fitting shall be of PF>0.90
Energy efficient LED light fitting with minimum 36 watt ,230V , size 2'X2' ceiling light Surface mounting type with and including connecting up twin core twisted flexible copper conductor cable with suitable size complete as per makes HALONIX cat. No.HLFPS22-02-36CW-R or equivalent in Philips / Surya Roshni Ltd/ Wipro /GE/Havells and as approved. Note: Light fitting shall be of PF>0.90
Energy efficent LED Security light fitting with minimum 20W New generation Energy saving &environmental frindly long life versatile pressure die cast aluminium luminiare with mid power LEDs as source and HF electronic driver pre wired with 1.5 Sq mm copper conductor cable upto connector including 2 Mtr long GI Tubing Med grade 32 mm dia bend to shape fixing on wall with suitable MS brackets compelte all as specified and as directred. Makes: HALONIX Cat No. HLSLD-09-20-CWL-R or equivalent in Philips/ Surya Roshni Ltd/r Wipro/GE/Bajaj/Havells Note: Light fitting shall be of PF>0.90
Energy efficient LED Bed/Tabble lamp light fitting with luminare minimum 03 Watt, 230V fixed in wall mounted with necessary diffuser with mounting brackets etc. including connecting up twin core twisted flexible copper conductor cable with suitable size complete as per makes HALONIX/ Philips / Surya Roshni Ltd/ Wipro /GE/Havells and as approved. Note: Light fitting shall be of PF>0.90
Energy efficient Flame proof LED tube light fitting with minimum 2X16 watt or minimum lumen output is not lessthan 3200 lumens,240V with drivers including connecting up twin core twisted flexible copper conductor cable with suitable size complete as per makesCG/ Sudhir and as approved. Note: Light fitting shall be of PF>0.90
Flame Proof Exhaust fan 300mm sweep, Heavy duty, complete with louvers suitable for operation on 230V AC, 50Hz fixed in wall, making opening, fixing and making good the distrubed surfaces etc. complete all as specified and directed.
Air circulator wall mounting type 450mm sweep or nearest size, Metal body (Heavy duty), complete with speed control system, suitable for operation on 230V AC, 50Hz, AC supply fixed in wall, making opening, fixing and making good the distrubed surfaces etc. complete all as specified and directed.
Ceiling fans AC single phase 230V of size 1200mm sweep with complete set with fixtures, 5 star rating, mettallic body and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete Havells or CG or Orient or Bajaj and as approved.
Exhaust fan 300mm sweep, AC single phase 230Volts, 50HZ, metal body (Heavy duty) completewith necessary fixing arrangement, and including louver shutters as when closed in stop position connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete and making good the distrubered surfaces of makes Havells or CG or Orient or Bajaj and as approved.
Exhaust fan380mm sweep, AC single phase 230Volts, 50HZ, Metal body (Heavy duty) completewith necessary fixing arrangement, and including louver shutters as when closed in stop position connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete and making good the distrubered surfaces of makes Havells or CG or Orient or Bajaj and as approved.
MCCB DB Concealed in wall vertical DB double door TPN 4 way 415V, 50Hz, IP 43 protection with 200A rated bus bar, including provision as incommer MCCB and outgoing circuits complete, fill empty with blanks, making good the disturbed area as per existing surface complete all as specified.
MCCB, 3 pole, 100 Amps, 16 KA, AC, 415 V, 50 Hz curve series with all incoming/outgoing connections with proper size of aluminium lugs complete all as specified.
MCCB, 3 pole, 63 Amps, 16 KA, AC, 415 V, 50 Hz curve series with all incoming/outgoing connections with proper size of aluminium lugs complete all as specified.
Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including medium duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 6 Sq.mm, Single Core, FRLS PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. Note: 2 runs of 6 Sq.mm, 1 runs of 6 Sq.mm & one run of 25mm dia PVC Conduit will be measured as one unit
Sub main wiring with 4 runs of single core 10 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including medium duty PVC Conduit, 40 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 10 Sq.mm, Single Core, FRLS PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. Note: 4 runs of 10 Sq.mm, 1 runs of 10 Sq.mm & one run of 40mm dia PVC Conduit will be measured as one unit
Telephone jack with shutter glossy white RJ45 complete all as specified and directed. Make: Anchor/ Havells/ ABB
S&F MCB DB, VTPN type, 12 way, 415 Volts, with 200Amps rated bus bar including of 160Amps MCCB TPN as incomer and as incomer and provision for MCB upto 100Amps TP, 12 Nos as outgoing complete all as specified and as directed. Note: Outgoing MCBs shall be measured and paid separately.
S&F MCB/Isolator TP 100A, 16KA all as specified and directed.
S&F MCB TP 63A, 16KA all as specified and directed.
S&F flanged end lift type Foot valve 100mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets etc complete all as specified and directed.
Suppy and fixing Integral LED aviation light compresing of aluminium housing with polycarbonate enclosure, 302 Nos LED of BAJAJ Cat part No. BGAV 302 LED) complete all as specified and directed.
SCHEDULE 'A' PART-XIX PHASE -II Material and labour for maintenance including watering and fertilization of all the grass/plants/trees by weeding housing saucer melding once in every 15 days, planting new plants/grass spices and height with out any extra cost to the department for a period of SIX MONTHS complete all as specified and directed.
SCHEDULE 'A' PART-XX PHASE -III COMPREHENSIVE MAINTENANCE OF LIFTS AFTER DEFECTS LIABILITY PERIOD OF 02 YEARS
Comprehensive maintenance of Electrically Operated 13 passenger lifts(884 Kgs) to serve G+11 upper floors all as mentioned vide SI No. 17 of BOQ Phase-I (Two Lifts) during 1st year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 08 passenger lifts(544 Kgs) to serve G+11 upper floors all as mentioned vide SI No. 18 of BOQ Phase-I (Three Lifts) during 1st year after expiry of defects liability period all as specified and directed
SCHEDULE 'A' PART-XXI PHASE -IV SECOND YEAR COMPREHENSIVE MAINTENANCE OF 13 & 8 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No.17 & 18 OF THIS BOQ / SCHEDULE "A" PART – XVII AFTER COMPLETION OF FIRST YEAR COMPREHENSIVE MAINTENANCE.
All as per description of item No. 101 but second year after expiry of defects liability period and After completion of first year Comprehensive Maintenance.
All as per description of item No. 102 but second year after expiry of defects liability period and After completion of first year Comprehensive Maintenance.
SCHEDULE 'A' PART-XXII PHASE -V THIRD YEAR COMPREHENSIVE MAINTENANCE OF 13 & 8 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 17 & 18 OF THIS BOQ / SCHEDULE "A" PART – XVII AFTER COMPLETION OF SECOND YEAR COMPREHENSIVE MAINTENANCE .
All as per description of item No. 101 but third year after expiry of After completion of second year Comprehensive Maintenance.
All as per description of item No. 102 but third year after expiry of After completion of second year Comprehensive Maintenance.
Note for SL No: 101 to 106 :- (i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above Lifts. (ii) Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed by Engineer-in-Charge and lubricating to all moving parts, topping parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation.
(iv) Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor. (v) Load testing shall be arranged by the contractor to the Lift for which repairs were carried out as and when directed by Engr -in-Charge. (vi) All maintenance works shall be carried out by well qualified tradesmen and supervisor of OEM.
K KUMAR RAJA PROJECTS P LIMITED
Komal Buildcon Pvt. Ltd.
AKM CONSTRUCTION AND ENGINEERING LLP
City Promoter and Buildwell Pvt. Ltd.
JANARDAN NIRMAN PRIVATE LIMITED
DES RAJ AND SONS BUILDERS PVT LTD
RKEC Projects Limited
Som Projects Pvt Ltd
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid