Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC | L1 | Accepted-AOC 1st Lowest |
Tender Value
₹4.8 L
EMD Value
₹11,882
Closing Date
22 Jun 2024, 6:00 pmClosed
The Assistant Executive Engineer ele
O/o The chief Engineer, Harbour Engineering Electrical Sub Division, Kamaleswaram, TVPM
Up Gradation of Odayam Shrimp Hatchery to SPF status-Electrical maintenance Work_General Electrical Work
2024_HED_675702_1
HED/CEHED/TR/1271/2023_6_1_1/1
Open Tender
Electrical Works
Item Rate
60 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,050
₹11,882
14 Oct 2024
13 Jun 2024
24 Jun 2024
13 Jun 2024
22 Jun 2024
13 Jun 2024
Amount
Electrical Maintenance work
1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.27.6:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.28.3:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
90.10.1.4:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )4 module moulded plastic box on surface
90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.34:Supplying and fixing brass batten/ angle holder including connection etc. as required.
1.41:Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.52:Painting of ceiling fan in installed position with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent etc. as required.
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
1.15.1:Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group A
1.15.3:Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C
OD5595/2023-2024:Supply of surface mounting corrosion resistant industrial lighting luminare WT 550C LED 40S CW PSU S1 PC (Philips) or equivalent 40 W LED lamp
OD5596/2023-2024:Supply and installing 7+/-2W LED bulkhead fitting (IP 65), housing made of die cast aluminium with 6500K colour temperature with a lumen output minimum 100lumen/Watt, CRI>80,beam angle 120 degrees, suitable for outdoor applications, including all connections etc. as required. Make -Philips -Vista glow or equivalent
OD5602/2023-2024:Supply and fixing Cable Junction Boxes IP 65 for outdoor applications (Thermoplastic Polycarbonate ) suitable for cable sizes 2.5 sq.mm ,80 X 80X 52 mm Cape model Abox i025 or equivalent and accessories for Cable Junction Boxes such as Copper Terminal Set 2.5 sq.mm 5 Pole 1 No,Support for Terminal 1No including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages etc. as required
OD5603/2023-2024:Conveyance, installation, testing and commissioning of departmentally supplied flood light / Area light luminaire with lamp on the existing tubular post of height upto 8m from ground level
OD5689/2023-2024:Supply and installation of High efficient LED Streetlight with Aluminium pressure Die cast housing parts for long life, Pure polyester powder coated Dark Gray housing, High purity PMMA lenses for superior performance, Toughened glass with silicon gaskets for IP66 protection, in-built electronic driver prewired up to terminal block,Suitable for external pole dia. Up to 45 mm, LED Make-Nichia/Cree/Osram, CRI >70,Temperature range- 0 to 45DegC, Driver efficiency>85%, Power factor>0.95, THD<10%, Colour Temperature- 5700K, Surge protection in CM-3.5KV, 50000 burning hours as per L70 Criteria, Multistage Isolated Constant Current- Constant Voltage Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard.LED street light, Wattage 40W, Suitable for external pole dia up to 50mm similar to Wipro Make LR02-451-XXX-57-XX/Bajaj/Crompton, with luminaire lumen 4000lm and System Efficacy 100lm/W
90.6.5.4:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 1.50 sq mm
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD5695/2023-2024:Supply of slim profile Square surface mounted Poly carbonate downlight of 12W, 1200 Lumens SM260C LED12S (Philips) or equivalent 12 W LED lamp
OD5696/2023-2024:Supply of slim profile Round surface mounted Poly carbonate downlight of 12W, 1200 Lumens SM250C LED12S (Philips) or equivalent 12 W LED lamp
14.2:Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
14.15.1:Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal)
OD5781/2023-2024:Dismantling of existing Installation and stacking the material in safe place as directed by the Engineer In charge-Khallasi
OD5782/2023-2024:Dismantling of existing Electrical installation and identifying and rectify the fault termination etc complete as directed by the Engineer In charge-Wireman
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
1.59:Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins reinstalling the same as required.
OD5783/2023-2024:Supplying and installation of 9W LED Lamp complete as required
1.47:Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
1.49:Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.
OD7717/2023-2024:Supply and fixing ceiling fan capcitor 2.5 mfd / 250V non-polarized electrolytic AC capacitor make keltron or equivalent
OD7718/2023-2024: Supply and fixing fan clamping Bolt and Nut set 30mmx8mm Nickel plated Bolt and suitable nut including, plate washer, Lock washer, lock nut and the bolt provision for use split pin
OD7719/2023-2024:Supply and installation of Rubber bush 10-15 mm diameter for fixing the fan to the ceiling etc complete.
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD7699/2023-2024:Supplying and providing 25X6 MM BRASS BOLT & NUT with washers on the existing MS box/ earth bus etc. as required including drilling necessary holes and required
OD7700/2023-2024:Supply and installation of good quality wall fan 400 mm sweep with three steel blades
OD7701/2023-2024:Supply and fixing 63A, 415V Porcelain Fuse unit suitable for HRC Fuse link
OD7702/2023-2024:Supplying 2A single pole MCB C curve
OD7703/2023-2024:Supplying 16mm dia LED type Phase indication lamp and motor ON indication (Red , Yellow & Green
OD7704/2023-2024:Supplying 16mm dia LED type Phase indication lamp Blue
OD7705/2023-2024:Supplying 100A two way disconnectable type Neutral Link
OD7706/2023-2024:Supply and installation of insulated 12 SWG GI wire for service binding wire including laying complte as required
OD7707/2023-2024:KSEB Documentation charge for Load enhancement of electric connection and related statutory documentation work including preparation of drawing complete as required
OD7708/2023-2024:Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 1.5 sq. mm
OD7709/2023-2024:Supply & laying of one number PVC insulated and PVC sheathed armoured Copper control cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3 core 1.5 sq mm
OD7711/2023-2024:Painting with epoxy paint of approved brand and manufacture to give an even shade. Two or more coats on new work.
OD7712/2023-2024:Painting with 2 coats of Industrial based Epoxy primer of approved brand and manufacture on steel galvanized iron/steel works (2 coats).
OD7726/2023-2024:Supply and fixing of special clamp painted with two coats of epoxy paint over a coat of epoxy primer for fixing LED tube fitting in the roof structure using 32x6mm MS flat using 4 Nos of 32mm brass screws
90.6.6.1:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.1.50 sq mm
OD8197/2023-2024:Supply and installation of High efficient LED Pathway luminaire with Aluminium pressure Die cast housing, Lenses for superior performance, Toughened glass cover with IP66 protection, Suitable for pole dia. Up to 60-76mm. Luminaire lumen>2870lm, System Efficacy>82lm/W, LED MakeCree/Citizen/Nichia/Osram, CRI >80,Temperature range- 0 to 40DegC, Driver efficiency>90%, Power factor>0.95, THD<20%, Colour Temperature- 5700K, Surge protection 4KV, 50000 burning hours as per L70 Criteria, Multistage Isolated Constant Current Operated driver with range 220-240V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard.LED pathway luminaire, 35W similar to Wipro Make LP06-351-XXX-57-XX/Bajaj/Crompton.
Bidder Name
ASOK ELECTRICALS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1050698.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .