Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC | ₹1.6 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.9 Cr+₹32.0 L (19.8%)Rejected-Finance 62 PINK ROSE COLONY KAIMARI ROAD 125001 | HISAR | HARYANA | 125001 | ₹1.9 Cr+₹32.0 L (19.8%) | L2 | Rejected-Finance Highest |
| 3 | L3₹2.2 Cr+₹56.0 L (34.6%)Rejected-Finance | ₹2.2 Cr+₹56.0 L (34.6%) | L3 | Rejected-Finance Highest |
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
18 Oct 2021, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Elect. Divn. PWD B and R Br. Ambala Cantt.
Construction of MCH Block and Service Block in the campus of Civil Hospital, Sec.-6, Panchkula. (Pdg. E.I only) (Recall).
2021_HRY_185091_2
PWD/Elect-KNL/Elect-AMB/110179
Open Tender
Construction Works
Works
365 days
Ambala Cantt.
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹3.2 L
Yes
15 Jun 2022
4 Oct 2021
19 Oct 2021
4 Oct 2021
18 Oct 2021
4 Oct 2021
Amount
Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) HSR No. 23.1.6.1
1 run of Size 4 Sqmm(1/2.24mm) HSR No. 23.1.6.3
COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group C HSR No. 23.2.1.3
Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group C HSR No. 23.2.2.3
Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C HSR No. 23.2.5.3
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch required MS Box etc complete as required Group C HSR No. 23.3.4.3
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) HSR No. 23.3.6.2
Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS pipe of 25 mm dia. HSR No. 23.6.6.2
Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. HSR No. 23.7.6.2
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data HSR No. 23.8.10.1
6 Modules HSR No. 23.8.10.4
12 Modules HSR No. 23.8.10.6
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch HSR No. 23.8.11.1
15 amp 1 way switch HSR No. 23.8.11.3
5 amp Socket HSR No. 23.8.11.4
15 amp 6 pin Socket HSR No. 23.8.11.5
Bell Push HSR No. 23.8.11.6
Step type Fan Regulator 2 modules 300 watt HSR No. 23.8.11.7
T.V. Socket outlet modular type HSR No. 23.8.11.9
Blanking plate HSR No. 23.8.11.10
USB Charger, 1000mA, 5V, 1 Module HSR No. 23.8.11.12
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp HSR No. 23.22.1.3
4 pole MCCB 6 amp to 100 amp HSR No. 23.22.1.9
4 pole MCCB 200 to 250 amp HSR No. 23.22.1.11
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) HSR No. 23.22.4.5
TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) HSR No. 23.22.4.7
TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing) HSR No. 23.22.4.8
Vertical TPN DB Double Door 4 way ( 8 incoming and 3phase*4 outgoing) HSR No. 23.22.4.9
Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole HSR No. 23.22.5.1
40 amp to 63 amp. MCB's TRIPLE POLE HSR No. 23.22.5.6
40 amp to 63 amp. MCB's FOUR POLE HSR No. 23.22.5.8
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide. HSR No. 23.24.1
EARTHING AND LIGHTENING ARRESTOR Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. HSR No. 24.1.3
Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. HSR No. 24.1.5
Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. HSR No. 24.1.7
Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. HSR No. 24.1.8
Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. HSR No. 24.1.13
Laying of underground cable in pipe /existing open/closed trench etc as required:- 50 Sq mm to 150 sqmm 2 to 4 Core HSR No. 24.2.4.3
185 sqmm to 240 sqmm 3 to 3½ Core HSR No. 24.2.4.4
300 sqmm to 400 sqmm 3 to 3½ Core HSR No. 24.2.4.5
Supply and erection of suitable compression type brass cable glands for underground Cable :- 70 sqmm to 95 sqmm Cable 3 to 3½ Core HSR No. 24.2.7.4
240 sqmm to Cable 3 to 32 Core HSR No. 24.2.7.6
300 sqmm to 400 sqmm Cable 3 to 3½ Core HSR No. 24.2.7.7
Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 95 sqmm HSR No. 24.2.8.9
240 sqmm HSR No. 24.2.8.13
400 sqmm HSR No. 24.2.8.15
Rising Main Sandwich Type Supply, Installation, Commissioning, Testing of Sandwich Rising Main 4 P ( 3 Phase 4 Wire) of aluminium busbars with 50% integral G.I housing earth, Bus trunking enclosure shall be made of 1.6mm thick Electro Galvanised G.I sheet, IP54 indoor, multi layer insulation of Class-F, including 2 runs of external Aluminium earthing through out the length of the Rising Main, vertical spring Hanger, Rigid hanger & Plug in point provision to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of Work. 400A/25KA NS-1 i)
630A/40KA NS-1 ii)
End Feed Unit (for Sandwich Rising Main) 400 Amp. with MCCB, Extended Rotary handle and Spreader Link NS-2 i)
630 Amp. with MCCB, Extended Rotary handle and Spreader Link NS-2 ii)
Plug-in-Box (for Sandwich Rising Main) 63 Amp. with MCCB, Extended Rotary handle and Spreader Link NS-3 i)
100 Amp. with MCCB, Extended Rotary handle and Spreader Link NS-3 ii)
125 Amp. with MCCB, Extended Rotary handle and Spreader Link NS-3 iii)
Supply of aluminium armoured cable of size 95 Sq. mm 3.5 Core, Make as per approved list NS-4
Supply of aluminium armoured cable of size 240 Sq. mm 3.5 Core, Make as per approved list NS-5
Supply of aluminium armoured cable of size 400 Sq. mm 3.5 Core, Make as per approved list NS-6
Supply & Erection of 16 Sqmm x 4 Core PVC insulated and PVC round sheathed copper conductor flexible industrial cable 1100 Volt with the help of all labour and petty material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work. Make as per approved list NS-7
Supply & Erection of 25 Sqmm x 4 Core PVC insulated and PVC round sheathed copper conductor flexible industrial cable 1100 Volt with the help of all labour and petty material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work. Make as per approved list. NS-8
J.B.S.Electrical Co.
Ecs Engineering Chd. Pvt. Ltd.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .