Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance SANAT NAGAR SRINAGAR PIN 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹85,000
Closing Date
6 Jul 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE EINGINEER MECHANICAL DIVISION KARGIL
Office of Executive Engineer Mech Div Kargil
Design, Supply, installation testing and commissioning of Hot Water Generator based central heating system to Office cum Residence of Karakul Farm Khumbathang of Sheep Husbandry Department.
2023_PWD_10194_1
MDK/e-NIT/05 of 2023-24
Open Tender
Machineries/ Mechanical Engg Items
Turn-key
60 days
Karakul Farm Khumbathang
Please refer Tender documents.
12 documents required · 12 mandatory
₹1,000
EXECUTIVE ENGINEER MECHANICAL DIVISION KARGIL
₹85,000
Office of Executive Engineer Mech Div Kargil
21 Jul 2023
1 Jul 2023
6 Jul 2023
3 Jul 2023
6 Jul 2023
3 Jul 2023
4 Jul 2023
Amount
Design, Supply Installation, testing and Commissioning of all necessary and integral component / equipments (or deemed necessary) as described here after. The scope of work includes the supply of DSITC of HWGs, radiator panels, Circulation pumps/ pipes, insulations, specialized valves, including construction of cement concrete foundation blocks of all equipments to provide fully automatic system capable of producing and maintaining high precision indoor conditions inside Office Cum Residence of Karakul Farm Khumbathang, Kargil Taking into account of duration factors for atmospheric condition of Kargil @Alt: 2676m
HSD Fired, Horizontal Fire Tube type , Hot Water Generator fitted with combustion equipments, all boiler mountings- control panel, control valves, accessories including primary circulation pumps of suitable capacity and mono block pump set, including chimney of recommended dia, externally mounted at 8mtr above ground level. or as recommended by OEM. Complete in all respect. Job includes 01 No. spare burner assembly. Capacity of boiler= 50,000 Kcal/ Hr
Compact Electric Hot Water Generator: Horizontal/vertical shell type Electrical Hot water Generator made out of Mild steel with pressure rating of 250-350 psig, insulation 50/100mmresin bonded fibre glass wool with 24/32 kg/m3 density.Heater bank 240 v +10%, 50 cycle 3 phase AC supply. The safety controls includes Digital step controller thermostat for individual step digital dial type thermometer for inlet and out let SCR based linear controller (step less) with pressure swatches and low water cut off switches. Job includes separate LT control panel having Capacity= 60 kW.
Pumps Hot water Circulation Pumps
Hot Water Circulation Mono-block Pump complete with electric motor of Single-Phase along-with common base frame duly grouted in cement concrete foundation. Suction 80 mm Delivery 65 mm Discharge: 6 LPS at 25 m Head Rating= 3-5 HP (aprox)
Oil Transfer Pumps Gear Oil Transfer Pump with electric motor single phase rating along-with common base frame duly grouted in cement concrete foundation
Capacity 2 LPS(min) @ 12-20 mtr Head
Soft water / Glycol Pumps Soft Water Pump complete with electric motor of 1-ɸ, 230 V, 50 Hz, 1 HP rating along with common base frame duly grouted in cement concrete foundation.
Capacity 5 LPS (min) at 12-20 m Head
Tanks Day oil Tank Day oil tank of 4 MM M.S plate complete with 6 KW heating unit, manhole dully covered, Gauge Glass and structural support for mounting oil tank and ladder made out of tubular MS Section complete including standing structures.
Capacity 500 litres,
Expansion Tank Hot Water Expansion Tank of 4 mm M.S complete with manhole dully covered, necessary connections covered with 50 MM thick, 750 GSM Mikron insulation and finished with 24 Gauge Aluminum cladding and structural support for mounting of Expansion tank.
Capacity 500 litres,
Soft Water Tank/ Glycol Water Tank Soft water tank of HDPE (tripple layer) with necessary connections
Capacity 500 litres
Hot Water Radiators Steel panel heating radiators conforming to EN442 with working pressure ranging from 10-13 bar having working temperature at 110°C ,complete with Top grilles and side covers as standard alongwith inlet valve, outlet valve, air purge valve and threaded plug as per OEM. Inlet Water Temp: 75oC Outlet Water Temp: 65oC Room Temp: 22oC
2000 Kcal/Hr (Double Panel Double Convector)
3000 Kcal/Hr (Double Panel Double Convector)
4000 Kcal/Hr (Tripple Panel Tripple Convector)
Piping
MS ERW pipe Mild steel ERW hot water piping of class ‘C’ (above/underground) complete with fittings like elbow, Tee, bends, flanges etc along-with structural supports as per norms and two coats of red oxide primer followed by two or more coats of bituminous paint complete in all respects. Insulation of hot water piping should be done with Elastomeric insulation of following thickness/ density. The above ground pipes running through the rooms, wards/ corridors boiler house etc shall be wrapped with two layers of polyethylene and chicken mess and covered with Aluminium cladding of 26 SWG. The underground pipes shall be shall be insulated with Elastometric insulation along wth Chicken mesh and tar felt.
80 mm DIA (50mm insulation)
50 mm DIA (50mm insulation)
PP-R pipe for hot and cold water supply, conforming to IS 15801, DIN 8077 of PN16/SDR 7.4, Complete with joints and fittings.
65 mm DIA
50mm DIA
40 mm DIA
32 mm DIA
25 mm DIA
20 mm DIA
Angle Iron Supports
Supports for hot water piping at various locations to be fabricated out of 40X40x5 mm, 5050x5 mm, 65x65x5 mm as per site requirement.
Butter Fly Valve
100mm C.I./G.M. Butterfly valve, PN10 complete
Ball Valve (PP-R)
50 mm DIA
40 mm DIA
32 mm DIA
25 mm DIA
20 mm DIA(Light Weight Brass)
Non- Return Valves C.I./G.M. Non Return Valve, PN 10, with Flanges etc. complete as per specification of the following sizes.
80 mm DIA (C.I. Flanged)
Y-Strainers C.I./G.M. Y Strainer with Flanges etc. complete as per specification of the following sizes.
80 mm DIA (C.I. Flanged)
Misc. Items
Pressure Gauges Glycerine filled as per specifications (100 mm Dial)
Thermometer as per specifications (100 mm Dial)
Air release valves with isolation ball valves (25mm)
Electrical
Main Panel Main Control Panel having separate cubicals for each equipment viz. isolation for Hot Water Generator 2 No's(1 standby), DOL Starter for Hot Water Circulation Pumps 2 No's , Soft Water Pumps 2 No's (1 hp each), DOL starter Softener pump 1 No (1 hp) and for HSD Transfer Pump 2 No's (1 hp) and three empty), and On-Load Change Over Switch (100 A), MCCB (100A). The control panel shall be provided with the copper bus bars dully insulated of required ratings and 3 in 1 digital Voltmeter / Ammeter / Frequency meter, indicators etc . Additional Control panel for 100kW Electric Boiler having, Change over switch of min 350Amp, Air Circuit Breaker of 350 Amp including digital volt meter/ammeter and satutuary control switches. Complete.
Cable Try Perforated cable tray of 2 mm thickness and supported from ceiling the wall duly painted as per site condition
150 mm wide
Electrical cable Providing and fixing PVC insulated un-armoured copper conductor cables from main panel board to various equipments to be laid over cable trays with appropriate clamps and fixing arrangements
3 Core - 6 sq.mm
3 Core - 2.5 sq.mm
2 Core - 1.5 sq.mm
Service Cable Single Core un Armored AL. Cable 150 Sq.mm
Servo Voltage Stabilizer 3-phase, Oil cooled Servo Stabilizer micro processor controlled with high and low voltage cut off, single phase preventer, short circuit and over load protection having digital display.220 – 460 volts Phase to phase with panel as per specifications duly filled with recommended transformer oil upto full capacity
Capacity: 125 k-VA with input of 220-460 Volts Phase to phase and output of 415 volts ±1% phase to phase
Silent Diesel Generator Set, Kva
Output Rating: 25 KVA No. of Phase: 3 phase Type of Governor: Electronic / Mechanical Control Panel: AMF Additional Features: Fitted with cold starting kit
Earthing
Earthing for various equipments inside boiler house using copper plate electrode of size 500 x 500x 3 mm placed in 1000 x 1000x 1800 mm pit filled with charcoal & salt by copper strip of size 20 x 3 mm alongwith perforated G.I pipe.
Coolant Providing and filling of Nontoxic antifreeze (the right antifreeze product intended for use in heating boiler) of ethylene glycol solution. Note: The quantity of anti-freeze is purely tentative.
Construction of Boiler house : Construction of a 10'x12'x12' boiler house using 25-gauge corrugated CGI sheets for walls and roof, MS tube/ISA framing, including PCC flooring with a minimum thickness of 6 inches using a mixture ratio of 1:2:4 (cement:sand:aggregate), RCC foundation and column works, electrification of the shed, and installation of suitable windows and an 8'x10' shutter door , complete in all respect.
Note: The quoted rate for the job shall be of inclusive of all costs and expenses related to the job, but it shall not include the applicable Goods and Services Tax (GST).
BHAT ENGINEERING WORKS
ECO HVAC SOLUTIONS
THERMOTECH ENTERPRISES
TL CONSTUCTION COMPANY
M/S A B ENTERPRISES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .