Superintending Engineer (civil)
SE CIVIL OFFICE NEW POWER HOUSE JODHPUR
R and M works of various 33 kv GSS under Balesar Sub-Division
2025_JdVVN_512885_23
NIT 17 /2025-26
Open Tender
Civil Works
Percentage
90 days
balesar
Tender fee, Processing fee, Earnest Money, Registration copy, GST, IT , PF registration etc.
2 documents required · 2 mandatory
₹1,180
AO (EA and Cash)
₹13,000
Yes
19 Nov 2025
19 Nov 2025
12 Mar 2026
19 Nov 2025
10 Mar 2026
19 Nov 2025
Dismantling old plaster or skirting racking out joints and cleaning the surface for plaster including rubbish to the dumping ground with in 50 mtr lead. [B-162/14.55]
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. 1: 3: 6 or richer mix.(B- 156/ 14.2.1)
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand) (B- 150/13.1)
Renewing glass panes, with putty ans nails whereever necessary: 4mm thick plain glass panes.(B-150/13.4.1)
Repair to stone masonary in cement sand mortar 1:6 with old & new stone. (B-151/13.12)
Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). (B-55/3.2.4)
Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. (B-109/10.24)
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size). (B- 54/3.1.7)
Random Rubble stone masonry for foundation and plinth in Cement Sand mortar above 30 CM thick wall in IS 1597(part-I) 1992 : cement Mortar 1:6: (1 Cement : 6 Sand). (B-69/6.1.6)
Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 25mm thick (B-139/12.3.1)
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joint etc. complete fine finish : 25mm thick (B-139/12.2.1)
Repair of door, window shutters including cost of material and labour for change of damaged :Style / rail of teak wood 30mm thick/ Aluminium Section 6" wide (B-154/13.33(a) (ii))
Repair of door, window shutters including cost of material and labour for change of damaged Panel by Shuttering Ply - 9mm thick (Commercial) (B- 154/13.33 (b) (i))
Pointing on stone masonry in cement sand mortar 1:3 (1 cement : 3 sand) : Deep groove pointing (B-143/12.31.3)
Pointing on stone masonry in cement sand mortar 1:3 (1 cement : 3 sand) : Flush / Ruled/ Struck or weathered pointing. (B-143/12.31.1)
Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm (B-132/11.18.2)
Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges : Kota stone minimum 30mm thick. (B- 72 /6.17.3)
White washing with lime to give an even shade including all scaffolding: New work (three or more coats). (B-143/ 12.34.1)
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: New work (Two or more coats applied @ 3.84 kg/10 sqm). (B-12.41.1)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work (B- 12.46.1)
P&F Indian type white glazed vitreous china Ist quality W.C. Orissa pan (IS:2556 Mark) with 100mm vitreous china P or S trap including cutting and making good the wall & floor.. Size 580X 440mm[S-1/1.2.1]
P & F WVC wash basin (1st quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. Pillar cock (I.S.: 8934 Mark) & 32 mm C.P. brass waste coupling of approved make, 25mm G.I. waste pipe complete including cutting & making good the wall :Size 510mm X 400 mm (S-7/1.396.2)
P&F G.I. pipes (Internal work) with G.I. fittings (I.S.: 1239 Mark) & MS clamps, including cutting and making good the walls and floors : B class Exposed on walla) a)15 mm dia nominal bore
b) 25 mm dia nominal bore (S-16/2.1.1&3)
P& F Bib Cock (IS : 8931 Mark), Superior quality of approved make a) C.P. Brass bib cock 15 mm(S-18/2.7.3)
P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15 mm Brass (IS:8931 marked).(S-20/2.12.1)
P & F Flush Cock/Flush Valve (IS: 9758 Mark) for WC of approved quality make:Brass/Gun metal Half-turn wt. 1 kg of approved quality / make 25 mm.(S-22/ 2.14.9)
P&F storage tank confirming to IS(12701/89) standards of approved make with cover, 25mm dia 1M long G.I. over-flow pipe and 25cm long wash out pipe with plug and socket, including making connec- tion etc. complete of approved designb) 500 Ltr capacity. (S-25/2.26.3)
P & F UPVC SWR. pipes grade 'B' for sciland wast discharge system (IS :13592-1992 marked) of approved make (b) 110 mm dia (S-46/3.45.2)
Providing & fixing precast cement concrete coping 1 : 2 : 4 mix 50mm thick complete as per specification : (B-3.8)
Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand). Add extra for Wall upto 30cm. and less thickness. (B-69/6.2.6+6.3.4)
Supply and fixing Jodhpur sand stone Machine cut Dash, Coping,sill,lintel fixed in cement sand mortar 1:4. 9 cm (3.5") thick (B-82/6.88 (ii))
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR E-1.1 (A) short poing (upt 3 mtr.) (1.1.1)
(B) Medium point (Upto 6.0 Mtr.)(1.1.2)
(C) Long point (Upto to 10.0 Mtr.)(1.1.3)
(B) 2x4.0 sq. mm + 1x 2.5 sq mm ( E-4.1.14)
Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR On board E- 1.3.1
Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR E-7.37
P & F ISI marked 32 A D.P. switch with fuse and indicating lamp including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . E-7.22
Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .1200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing E- 17.2.2
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.68 MB
RnM_33kv_balesar.pdf
Tender Documents • 0.71 MB
BOQ_917424.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .