Loading…
Loading…
Tender ID
Tender Value
₹14.3 L
EMD Value
₹14,252
Closing Date
20 Apr 2026, 2:00 pmClosed
Manager
Installation of FIRE HYDRANT, SPRINKLER AND ALARM SYSTEM, YAGNIK ROAD BRANCH (2nd Attempt)
295926
Installation of FIRE HYDRANT, SPRINKLER AND ALARM SYSTEM, YAGNIK ROAD BRANCH (2nd Attempt)
Open
Fire and Safety Services
Works
Rajkot
3 documents required · 3 mandatory
₹900
RAJKOT NAGARIK SAHAKARI BANK LTD
₹14,252
11 Apr 2026
11 Apr 2026
11 Apr 2026
20 Apr 2026
11 Apr 2026
Sr. No. DESCRIPTION Approved Makes QTY UNIT Rate Amount
Supplying, installing, testing and
commissioning of Electric motor Driven
Horizontal / Vertical Main Fire Pump Set
1 suitable for automatic operation and Lubi / Kirloskar 1 No. 180000
complete in all respect as required.
1620 LPM @ 70 mtr head
Supplying, installing, testing and
commissioning of Electric motor Driven
Horizontal / Vertical Jockey Pump Set
2 suitable for automatic operation and Lubi / Kirloskar 1 No. 46000
complete in all respect as required.
lpm @ 70 mtr head
Supplying, installing, testing and
commissioning of Diesel engine Driven
3 Lubi / Kirloskar 1 No. 320000
pump 1620LPM @ 70 mtr head
Supplying, installing, testing and
commissioning of Control Panel suitable
4 for start and stop of fire pump without L&T 1 Lot 86000
cabling & cable accessories
5 Providing and fixing of dial type H.Guru / AirMaster 3 Nos.
Pressure Guage having 100 mm dial &
range of 0-14 Kg/cm2
6 Providing and fixing of Pressure Switch Danfoss 2 Nos.
for fire fighting
pumps auto operations
Providing and fixing, testing and LP / Kartar /
commissioning of CI Buterfly Valve Leader/ DRP
conforming to BS 5155 class PN
c) 80 mm 1 Nos. 1800
d) 65 mm Nos. 1600
e) 50 mm Nos. 1500
f) 200mm Nos. 6500
8 Providing, fixing, testing and LP / Kartar /
commissioning of CI Non- Return valve Leader/ DRP
class PN 1.6 rating of sizes
a) 200mm (dual plate) Nos. 9000
9 Supplying and fixing approved make 25 Leader / Zoloto / 2 No.
mm dia single acting air release valve Sant/RB
10 Supplying and fixing approved make Leader / Zoloto /
forged brass ball valve, screw end type, Sant/RB
PN 1.6 rating of sizes
(a) 25mm 5 Nos. 800
Supplying, installing, testing and Asian / Jindal / Tata
commissioning of GI Class 'Heavy'(C / Apollo
Class) pipes confirming to IS 1239 Pt -I
Medium Grade upto 150 NB & above IS:
11 3589 without painting, with anchor
fasteners, bolts nuts, clamps, "U" bolts,
MS fittings such as Reducers, Tees,
Elbows etc. as per drawings.
a) 150 mm 6 Mtrs. 1676
b) 100 mm 40 Mtrs. 1349
c) 80 mm 1 Mtrs. 1120
d) 65 mm 0 Mtrs. 980
e) 50 mm 10 Mtrs. 826
f) 40 mm 0 Mtrs. 709
g) 32 mm 0 Mtrs. 680
h) 25 mm 20 Mtrs. 580
i) 200mm 0 Mtrs. 1900
Providing, fixing, testing and ASSIAN / A. R.
commissioning of anti corrosive Laminators
treatment for under ground pipes with
12 coats of asphaltic primer and wound 2 Mtrs. 1000
with polymeric tap of thickness 4 mm
with 15 mm overlaping as per IS:
Providing, fixing, testing and
commissioning of SS single headed
oblique pattern hydrant landing valves
13 as per IS: 5290 with 80 mm dia flanged Aaag/ PROTECTO 5 Nos. 4200
inlet & 63 mm dia female outlet
complete with gun metal cap.
14 Providing, fixing, testing and Aaag/ PROTECTO 10 Nos.
commissioning of 2 nos. of 63 mm dia
15m long non percolating flexible Hose
(RRL type A) as per IS:636 with S.S.
male & female instanteneous type
15 Providing, fixing, testing and Aaag/ PROTECTO 5 Nos.
commissioning of Standard SS branch
pipe with nozzle of 20 mm nominal bore
outlet as per IS:903 suitable to fit with
standard instanteneous type 63 mm dia
Providing, fixing, testing and
commissioning of
Standard fire hose cabinet wall
mounting type having double door
16 Local 5 Nos. 2200
opening with necessary locking
arrangement by allan key suitable for
housing of 2 nos. 15 mtrs. Hose pipe &
1 no. Branch pipe,
Providing, fixing, testing and
commissioning of Wall
mounting type first aid Fire Hose Reel
without drum, hanging bracket, 30 M x
17 Aaag/ PROTECTO 5 Nos. 5600
20 mm dia high pressure hose pipe with
SS shut off nozzle and all required
Supplying, fixing, installing and
commissioning of fire brigade inlet
connection of 4 way with 4 nos. 63 mm
dia built in Gun metal / SS Non return
18 valves instantaneous coupling type Aaag/ PROTECTO 0 No. 9800
arranged on 150 mm dia. Pipe manifold
and connected to riser main line as per
Supplying, fixing, installing and
commissioning of fire brigade inlet
connection of 2 way with 2 nos. 63 mm
dia built in Gun metal / SS Non return
19 valves instantaneous coupling type Aaag/ PROTECTO 1 No. 6800
arranged on 100 mm dia. Pipe manifold
and connected to riser main line as per
20 Providing and fixing of 15 mm dia
quartzoid bulb type sprinkler head
Standard Response, standard coverage
a) Pandent Sprinkler 57°C 10 Nos. 100
21 Providing & fixing of AUTOGLOW Local
Signages in Block / Small Letters of
Specified Sizes:
a) ABC FIre Extinguisher: 8" X 4" 6 Nos. 100
b) CO2 Fire Extinguisher: 8" x 4" 6 Nos. 100
c) Fire Hydrant: 15" x 4" 6 Nos. 100
d) Fire Hose Box: 15" x 4" 6 Nos. 100
e) Fire Hose Reel: 15" x 4" 6 Nos. 100
22 Providing and fixing of Fire ISI Approved
Extinguishers, Hand appliances:(With
Minimum Five Year Life Validity)
a) ABC 6KG kanex / seasfire 6 Nos. 2100
b) Co2 4.5 kg kanex / seasfire 6 Nos. 4500
Providing and fixing of fire alarm Per
system with on off switch as per Tower
23 Agni / honeywell 1 120000
requirement and specification of
ADDRESABEL fire alarm system
24 Smoke detectors conventional based honeywell / rawel / 40 Nos.
with required wiring 1 mm 2 core agni
Designing / planning of all installation
systems, approval drawings of CFO /
Fire,hydrant,sprinklersystem,smoke &
alarm system or required drawing etc
) and Charges for liasoning with CFO
25 / RFO and getting all approvals (FSPA 1 Nos. 50000
- PRE NOC AND FINAL NOC ) and
permissions & NOC 's required for
fire fighting at various stages &
after completion of the project.
TOTAL BASIC AMOUNT
TOTAL PROJECT AMOUNT
IN WORDS : FOURTEEN LAKH TWENTY FIVE THOUSAND ONE HUNDRED NINETY NINE ONLY
I/We _________________________________________________ am/are willing to carry out the above work at
___________________ % above/below ___________________ percent (should be written in figures and words) of the estimated
rate mention above estimated amount of my/ours tender work out as under.
ESTIMATED AMOUNT PUT TO TENDER ESTIMATED AMOUNT PUT TO TENDER
Total Amount Rs. ________________________ Total Amount Rs. ________________________
Total Amount Rs. ________________________ Total Amount Rs. ________________________
SIGNATURE OF THE BIDDER
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1.Cover Page - Index.pdf
2. MEMORUNDUM1.pdf
3. SECTION - I - INVITATION TO BID AND INSTRUCTION.pdf
4. BOQ TENDER UPLOAD.pdf
5.2 YAGNIK ROAD FIRE SHEET 2.pdf
5.1 YAGNIK ROAD FIRE SHEET 1.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .