Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance HARIBHAVAN NORTH ARIYAD P O ALAPPUZHA | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance LSGD DIVISION ALAPPUZHA | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹12.8 L
EMD Value
₹32,047
Closing Date
12 Mar 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SECRETARY ARYAD BLOCK PANCHAYATH
BLOCK PANCHAYATH OFFICE ARYAD
P NO SO89/24 ARYAD B.P MUHAMMA CHC ELECTRIFICATION AND PROVIDING GENERATOR-GENERAL ELECTRICAL WORK
2024_CRD_664787_1
SO89/24
Open Tender
Electrical Works
Item Rate
120 days
KALAVOOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹32,047
13 Mar 2024
2 Mar 2024
13 Mar 2024
2 Mar 2024
12 Mar 2024
2 Mar 2024
2 Mar 2024 - 12 Mar 2024
Amount
ELECTRIFICATION
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.14:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.23.3:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.15/16 amp switch
1.23.5:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 amp socket outlet
90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
OD282826/2023-2024:Supply ,conveyance, installation, testing and commissioning of three phase 63 KVA DG set ,battery and other accessories with approved as a complete set including first fill of lube oil engine oil & Engine safeties and all other standard accessories including CPCB approved acoustic enclosure etc.as required. Kirloskar/ Asokleyland / Koel / Cummins or it's equivalent make with fittings as detailed below.Engine.1.; Flywheel and flywheel housing 2. 12 V DC electric start arrangement 3. Exhaust Silencer & residential Type Silencer 4. Fuel Filter (Pre and Micro) 5. Lube oil filter & type 6. Radiator (For liquid cooled DG set only) 7. Dry Type Air Cleaner& 8. Battery charging Alternator &9. Fuel hoses 10. Maintenance manual and spare parts catalogue&11. Radiator fan (For liquid cooled DG set only)&12. Fuel injection pump with mechanical governor and fuel feed pump&13. Closed Coupled Engine with inbuilt Anti Vibration Mounting Pads 14. First Fill of Lube Oil 15. First fill of Coolant ( Life is 3000 running hours or 3 years) Alternator& KOEL/ KEL/ STAMFORD make self & excited, self regulated, screen protected, drip proof alternator with static excitation system, capable of developing rated output at 415V, 0.8 p.f. 50 Hz when running at 1500 RPM at NTP conditions and conforms to the IS 4722 standards.<br> Control panel consisting-Genset controller having Alternator parameter like voltage, frequency, Amps, KW, KVAR,PF etc.,3 nos current transformer.KW hour meter, alu. bus bar, indication lamps, MCB, instruments fuses ,earthing studs etc complete.
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
OD282850/2023-2024:Supply & fitting 65 mm dia. or nearest size MS. 'C; class pipe as extra length of DG exhaust pipe as required.
OD282857/2023-2024:Supply of Diesel for DG test running.
90.16.1.6:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required6.00 mm copper conductor (4 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.6:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.6. mm ( 4 SWG)
OD282886/2023-2024:Supply & providing 2.5mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to with stand 11KV dielectric strength.
OD282891/2023-2024:Supply, installation, testing and commissioning of high wall mounting INVERTER type 5 STAR split air conditioner unit conforming io IS 1391(Part II)(amendments-1 except power consumption norms) fitted with hermetically sealed compressor operating on 230V single phase AC supply, R32/R134/R410 /non CFC refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc with copper condensing coil,white / off white colour of following capacity, with cordless remote control etc with one year warranty for machine and 3 years for compressor. 1 Tr INVERTER type 5 star single phase split AC unit including Cu pipe connection & electric cabling from indoor to outdoor unit upto 3m (O General/Daikin/Voltas/Bluestar equivalent)
OD282913/2023-2024:Supply and Fixing of 2 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 240V (V-Guard or its equivalent)
OD282914/2023-2024:Supply and installation of out door unit stand for single/three phase wall mounting split AC unit as required-
OD282922/2023-2024:Earthing with 40 mm dia. medium class GI earth pipe 2 Mtr. long, providing 12mm dia. drilled holes minimum 20 nos along the entire length in alternate arrangement ,providing 40x25 mm GI reducer at top, test joint using 2 nos ,25x3 mm GI strip minimum size 25CM suitably shaped & tightly clamped to the pipe using 25x6 mm steel bolt & nut,washer,providing 2 nos 6 mm dia. drilled holes for clamping & bolting earth lead ,making masonary chamber with cover plate having locking arrangement etc. (charcoal & salt as required shall be filled at 30 CM dia .around the earth electrode)
OD282923/2023-2024:Supply & providing 5 kg / nearest size Dry chemical powder type fire extinguisher with hose & clamps fixing it to wall as required.
OD282929/2023-2024:Charges for preparing documents for submitting electrical inspectorate for initial & final approval.
90.12.5.29:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 50 sq mm
90.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
OD330238/2023-2024:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 4 core 2.5 sq mm
9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
90.12.10.4:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation77/63 mm or nearest size
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7:Supply and providing copper earth bus in the panel board
2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
2.1.3:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
OD330107/2023-2024:Supply and providing AMF Relay suitable for 63 kVA 440V 50 hz supply system including providing all necessary accessories complete.
OD330114/2023-2024:S&P LED phase indication lamp RYB
OD330125/2023-2024:S&P multi function meter with CT for A,V, PF, W, Hz etc
OD330138/2023-2024:Supply &providing 80A HRC fuse link in position.
OD330151/2023-2024:Supply and providing 40A, HRC Fuse link
OD330170/2023-2024:20 A HRC fuse link
OD330266/2023-2024:Supply and making end termination with brass compression gland and cu lug for following size of PVC insulated and and PVC sheathed/XLPE cu conductor cable 1.1 KV grade as required 4c 2.5 sq.mm
PHILIPOSE JOSEPH
Bidder Name
HARISH AND CO
PHILIPOSE JOSEPH
stage.html
html • 0.02 MB
finance_1031920.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .