Remaining MGPS Supply system at Mandore District Hospital Jodhpur
2026_RSRDC_547233_1
RSRDC NIT 777/2025-26 (Sl-1)
Open Tender
Electrical Works
Percentage
60 days
Jodhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Through RTGS/NEFT/IMPS
₹21,400
2 Apr 2026
19 Mar 2026
1 Apr 2026
19 Mar 2026
30 Mar 2026
20 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SITC of Dessicant Air Dryer Output Capacity - 60 cfm with UL Certified Microprocessor Controller with dewpoint based changeover option, Pre-filter rating 0.3 microns , Shuttle valve for Low Pressure drop, All Aluminium resist oxidation & scale formation, Dewpoint better than -40o C including fixing on wall with required T & P making connections etc complete in all respect. | |||||
| 2SITC of Compressed Air System should consist of 1 nos. Air Compressors with Electric Motors, Electrical Switch Gear and Automatic Control System of following Specifications: a)Air Compressor 1(One) Nos; Type Non-lubricated / Oil-free; Capacity 57 cfm at 8.5 kg/cm2; Cooling Air cooled b)Drive- Electric Motor 2(two) Nos; Capacity 15 HP; Speed 1440 rpm (syn.); Drive Belt drive; Electricity supply 440 volt, 50 Hz. 3 phase c)Starter Star/Delta Control & Switchgear with overload rotection.including making PCC foundation and fixing withbolts , anti vibration pad and making connections complete as required. | |||||
| 3SITC. of Compressed air filtration system:One set of 3 - stage filter The filters should be made of die cast aluminums housing with epoxy power paint on the outside and anodized surface treatment inside to prevent corrosion and ensure extra long life. The filters should have maximum contaminant removal efficiency with minimum pressure drop. Total 3-stage of filters should be used as mentioned below: Stage 1 : coalescing filters for general-purpose protection, removing liquid water and oil aerosol to 0.1 mg/cum. (0.1 pm) and particles down to 5 micron. Stage 2 : particular filter for dust protection, removing particles down to 1 micron. Stage 3 : high efficiency coalescing filters, removing liquid water and oil aerosol to 0.01 mg/cu.m. (0.01 pip) and particles down to 0.01 micron. | |||||
| 4SITC of Hot dipped galvanized ( inside and outside )Air receiver tank (as per IS:7938-1976 and upto date amendment) for compressed air system to dampen out pulsation and condense and trap the moisture in the compressed air and also to let oil and other impurities settle down before air passes into the piping with safety valve , Drain Valve , Pressure gauge and fusible plugs of 1000 litres capacity complete as required including making PCC foundation and fixing with bolts and making connections complete as required. | |||||
| 5SITC of MGPS of medically grade as per BSEN-13348 with third party certification from Lloyds/TUV degreased [ie free from oil, grease and particulate matters) seamless copper pipe confirming to ASTM B88 and all copper joining done by brazing with AWSA5.8, classification BCuP-S or BS 1845 following procedure in accordance with ASTM B828 after purging with nitrogen. All pipe cutting shall be carried out with a radial pipe cutter and copper pipe fitting's shall comply with B4 alloy designation. Adequate support shall be provided while laying pipeline testing shall be done at 17 bar and after testing pipe shall be painted with two coat of enamel paint as per colour codification as per ISO 7396-Part-I 2016. | |||||
| 6SITC of Gas outlet points (AR-4), (AR-7) and Vaccum (8.7 psig) for dispensing medical gases (oxygen/air/Vaccum) at point of use confirming to BSEN ISO 9170-1:2008. The gas outlet are quick connect type it should have colorc oding for different gas source and should accept only respective adapters as required. | |||||
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
AgrrementRTPPandetc.pdf
Tender Documents • 2.75 MB
BankDetail00.pdf
Tender Documents • 0.17 MB
BOQ_975798.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .