| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC 622 A STREET NO 3 FIRST FLOOR SHAKTI NAGAR BATHINDA 151001 PUNJAB | BATHINDA | PUNJAB | 151001 | ₹37.8 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹40.3 L+₹2.5 L (6.48%)Rejected-AOC VILLAGE GOROIMARI PO HALESWAR TEZPUR 784104 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784104 | ₹40.3 L+₹2.5 L (6.48%) | L2 | Rejected-AOC Not Being L1 |
| 3 | L3₹44.5 L+₹6.7 L (17.8%)Rejected-AOC CHANDMARI WARD NO 19 PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | ₹44.5 L+₹6.7 L (17.8%) | L3 | Rejected-AOC Not Being L1 |
| 4 | L4₹46.2 L+₹8.4 L (22.3%)Rejected-AOC PO KETEKIBARI DISTT SONITPUR TEZPUR ASSAM 784001 | SONITPUR | ASSAM | 784001 | ₹46.2 L+₹8.4 L (22.3%) | L4 | Rejected-AOC Not Being L1 |
| 5 | L5₹47.0 L+₹9.2 L (24.4%)Rejected-AOC | ₹47.0 L+₹9.2 L (24.4%) | L5 | Rejected-AOC Not Being L1 |
| Sl No | Description | Qty | Unit | Singhs Construction L2 | kabitaconstruction L6 | VARNI BUILDERS L4 | M/S MECHANICAL ENGINEERING and ELECTRICAL CONTRACTORS L5 | MAHANTA ENTERPRISES L3 | Truly Technos LLP L1 |
|---|---|---|---|---|---|---|---|---|---|
| 0.00SCHEDULE 'A' PART-I (B/R PORTION) | |||||||||
| 1.00General Note: (i) Being Maintenace contract of HT supply system contractor has to attended all breakdown occur in system immediately. If contractor fails to attend the break down within 4 Hours suitable Panelity will imposed and @ Rs 500 Per hour will be charged from contractor. (ii) Being Maintenace contract of HT supply system contractor should not force for full site to be handover at one time for repair. Site will be given as per complaint received and reuirement for repairing of cables / fault detections etc. However maint of VCB`s and maint of 33 KV Grid to be done in planed manner with in time limit with minimum shut downs. | |||||||||
| 2.00 | Servicing, Repairing and Maintenance of existing HT 11 KV,400/630/800 Amps rating VCBs (Make : Crompton Greaves/ Areva ‘Alstom’/ Schneider/ Seimens/ ITE/Andrew Yule) by removing from housing, overhauling the mechanical parts and periodic maintenance servicing of 11KV indoor/ outdoor VCBs, checking of quality of vacuum interrupter, insulation resistances, static contact resistance, testing ( IR value, Ratio Test, Polarity) and connection checking of 11 KV Current Transformer ( Set of Three) by primary injection kit ,testing and calibration of relay ( Set of, Two Over Current and One Earth Fault Relays) by secondary injection kit including,all other functional tests of the VCB panels including for CTs, PTs, complete all as specified and directed.
Notes:- (i) (i) The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge. (ii) Calibration and Testing(s) shall be done through State Electrical Licencing Board's valid electrical licence holder for the appropriate class/category of the work as approved by the Engineer in Charge.
(iii) Contractor shall submit Tripping test & Relay calibration certificate against each VCB duly signed by all concerned. (iv) Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after. | 30 | Each Job | 12,500 ₹3,75,000 | 13,150 ₹3,94,500 | 13,850 ₹4,15,500 | 18,411 ₹5,52,330 | 13,250 ₹3,97,500 | 12,000 ₹3,60,000 Lowest |
| 3.00 | Servicing, Repairing and Maintenance of existing HT 33 KV,1250 Amps rating VCBs (Make : Areva ‘Alstom’) by removing from housing, overhauling the mechanical parts and periodic maintenance servicing of 33 KV indoor outdoor VCBs,checking of quality of vacuum interrupter, insulation resistances, static contact resistance, testing ( IR value, Ratio Test, Polarity) and connection checking of 11 KV Current Transformer ( Set of Three) by primary injection kit ,testing and calibration of relay ( Set of, Two Over Current and One Earth Fault Relays) by secondary injection kit including,all other functional tests of the VCB panels including for CTs, PTs,complete all as specified and directed.
Notes:- (i) The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge. (ii) Calibration and Testing(s) shall be done through State Electrical Licencing Board's valid electrical licence holder for the appropriate class/category of the work as approved by the Engineer in Charge.
(iii) Contractor shall submit Tripping test & Relay calibration certificate against each VCB duly signed by all concerned. (iv) Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after. | 3 | Each Job | 12,650 ₹37,950 Lowest | 13,500 ₹40,500 | 13,900 ₹41,700 | 35,667 ₹1,07,001 | 13,500 ₹40,500 | 13,000 ₹39,000 |
| 4.00 | Servicing, Repairing and Maintenance of existing HT 11 KV, 630 Amps rating Ring Main Unit, SF 6 insulated isolator (Make : Crompton Greaves) by removing from housing, overhauling the mechanical parts and periodic maintenance servicing of 11 KV indoor / outdoor RMUs, including cutting, fabrication and welding of gas chamber and checking of quality of interrupter, insulation resistances, static contact resistance, testing ( IR value, Ratio Test, Polarity) and connection checking of 11 KV Current Transformer ( Set of Three) by primary injection kit ,testing and calibration of relay ( Set of, Two Over Current and One Earth Fault Relays) by secondary injection kit including,all other functional tests of the VCB panels including for CTs, PTs,complete all as specified and directed.
Notes:- (i) The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge. (ii) Calibration and Testing(s) shall be done through State Electrical Licencing Board's valid electrical licence holder for the appropriate class/category of the work as approved by the Engineer in Charge.
(iii) Contractor shall submit Tripping test & Relay calibration certificate against each RMU duly signed by all concerned. (iv) Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after. | 5 | Each Job | 14,500 ₹72,500 Lowest | 16,800 ₹84,000 | 18,800 ₹94,000 | 29,648 ₹1,48,240 | 17,930 ₹89,650 | 25,000 ₹1,25,000 |
| 5.00 | Supply Only, panel indicating lamp fitting, LED type suitable for110 volt/ 230 volt AC with base complete all as specified
(Make: L&T / Siemens / STS/AE) | 30 | Each | 180 ₹5,400 Lowest | 220 ₹6,600 | 190 ₹5,700 | 292 ₹8,760 | 215 ₹6,450 | 240 ₹7,200 |
| 6.00 | Supply Only, Digital AC Ammeter with 3 ½ digit display and with built in selector switch, Type 3 PH, Range 5 Amp Direct and with CT secodary site selectable 1A/5A, flush mounting size 96 mm X 96 mm, Accuracy Class 1.0, all as per Model No WL131010OOOO of Make “L&T” or equivalent Model of Make MECO/AE / Secure / Conzerv, complete all as specified. | 10 | Each | 1,550 ₹15,500 | 1,650 ₹16,500 | 1,650 ₹16,500 | 1,291 ₹12,910 Lowest | 1,695 ₹16,950 | 14,500 ₹1,45,000 |
| 7.00 | Supply Only, Breaker Control Switches,TNC (Trip,Neutral and Close), rating 25 Amps with contact arrangement 1Trip + 1Close, barrel lock mounting type, suitable for 11 KV VCB panels, complete all as specified.
(Cat No 73257SEB90PGBB of Make L&T or equivalent Model of Make: Switron / Recom /Kaycee / Areva) | 10 | Each | 2,960 ₹29,600 | 4,500 ₹45,000 | 3,950 ₹39,500 | 3,481 ₹34,810 | 3,280 ₹32,800 | 1,850 ₹18,500 Lowest |
| 8.00 | Supply Only, heater with heater switch & thermostat suitable for 11KV VCB panels, 80 watts, as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/ Seimens/ITE/ Andrew Yule) | 20 | Each | 1,550 ₹31,000 | 2,550 ₹51,000 | 2,150 ₹43,000 | 699 ₹13,980 Lowest | 2,380 ₹47,600 | 1,300 ₹26,000 |
| 9.00 | Supply Only, HT Current Transformers, single phase indoor solid state (Resin cast) 11 KV, ratio 150/5A, accuracy class 5P10, rated burden 15VA, STC 13.1 KA for 1second,suitable for VCB Panels as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/ Andrew Yule) | 5 | Set of Three | 52,975 ₹2,64,875 Lowest | 68,500 ₹3,42,500 | 53,700 ₹2,68,500 | 69,111 ₹3,45,555 | 54,580 ₹2,72,900 | 68,500 ₹3,42,500 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
8 Oct 2025, 6:00 pmClosed
CWE AF Borjhar
HQ CWE AF Borjhar Military Engineer Services PO Airport Borjhar Guwahati Assam 781015
REPAIR/MAINT OF RMU, VCBs AND HT CABLE OF RING MAIN SYSTEM OF EXTERNAL ELECTRIFICATION AND ALLIED WORKS UNDER GE (AF) TEZPUR
2025_MES_730273_1
CWE(AF)/TEZ/TOKEN-13/ 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Tezpur
As per tender documents.
8 documents required · 8 mandatory
₹500
GE AF Tezpur
₹90,000
Yes
23 Dec 2025
10 Sept 2025
10 Oct 2025
10 Sept 2025
8 Oct 2025
24 Sept 2025
Amount
SCHEDULE 'A' PART-I (B/R PORTION)
General Note: (i) Being Maintenace contract of HT supply system contractor has to attended all breakdown occur in system immediately. If contractor fails to attend the break down within 4 Hours suitable Panelity will imposed and @ Rs 500 Per hour will be charged from contractor. (ii) Being Maintenace contract of HT supply system contractor should not force for full site to be handover at one time for repair. Site will be given as per complaint received and reuirement for repairing of cables / fault detections etc. However maint of VCB`s and maint of 33 KV Grid to be done in planed manner with in time limit with minimum shut downs.
Servicing, Repairing and Maintenance of existing HT 11 KV,400/630/800 Amps rating VCBs (Make : Crompton Greaves/ Areva ‘Alstom’/ Schneider/ Seimens/ ITE/Andrew Yule) by removing from housing, overhauling the mechanical parts and periodic maintenance servicing of 11KV indoor/ outdoor VCBs, checking of quality of vacuum interrupter, insulation resistances, static contact resistance, testing ( IR value, Ratio Test, Polarity) and connection checking of 11 KV Current Transformer ( Set of Three) by primary injection kit ,testing and calibration of relay ( Set of, Two Over Current and One Earth Fault Relays) by secondary injection kit including,all other functional tests of the VCB panels including for CTs, PTs, complete all as specified and directed. Notes:- (i) (i) The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge. (ii) Calibration and Testing(s) shall be done through State Electrical Licencing Board's valid electrical licence holder for the appropriate class/category of the work as approved by the Engineer in Charge. (iii) Contractor shall submit Tripping test & Relay calibration certificate against each VCB duly signed by all concerned. (iv) Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after.
Servicing, Repairing and Maintenance of existing HT 33 KV,1250 Amps rating VCBs (Make : Areva ‘Alstom’) by removing from housing, overhauling the mechanical parts and periodic maintenance servicing of 33 KV indoor outdoor VCBs,checking of quality of vacuum interrupter, insulation resistances, static contact resistance, testing ( IR value, Ratio Test, Polarity) and connection checking of 11 KV Current Transformer ( Set of Three) by primary injection kit ,testing and calibration of relay ( Set of, Two Over Current and One Earth Fault Relays) by secondary injection kit including,all other functional tests of the VCB panels including for CTs, PTs,complete all as specified and directed. Notes:- (i) The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge. (ii) Calibration and Testing(s) shall be done through State Electrical Licencing Board's valid electrical licence holder for the appropriate class/category of the work as approved by the Engineer in Charge. (iii) Contractor shall submit Tripping test & Relay calibration certificate against each VCB duly signed by all concerned. (iv) Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after.
Servicing, Repairing and Maintenance of existing HT 11 KV, 630 Amps rating Ring Main Unit, SF 6 insulated isolator (Make : Crompton Greaves) by removing from housing, overhauling the mechanical parts and periodic maintenance servicing of 11 KV indoor / outdoor RMUs, including cutting, fabrication and welding of gas chamber and checking of quality of interrupter, insulation resistances, static contact resistance, testing ( IR value, Ratio Test, Polarity) and connection checking of 11 KV Current Transformer ( Set of Three) by primary injection kit ,testing and calibration of relay ( Set of, Two Over Current and One Earth Fault Relays) by secondary injection kit including,all other functional tests of the VCB panels including for CTs, PTs,complete all as specified and directed. Notes:- (i) The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge. (ii) Calibration and Testing(s) shall be done through State Electrical Licencing Board's valid electrical licence holder for the appropriate class/category of the work as approved by the Engineer in Charge. (iii) Contractor shall submit Tripping test & Relay calibration certificate against each RMU duly signed by all concerned. (iv) Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after.
Supply Only, panel indicating lamp fitting, LED type suitable for110 volt/ 230 volt AC with base complete all as specified (Make: L&T / Siemens / STS/AE)
Supply Only, Breaker Control Switches,TNC (Trip,Neutral and Close), rating 25 Amps with contact arrangement 1Trip + 1Close, barrel lock mounting type, suitable for 11 KV VCB panels, complete all as specified. (Cat No 73257SEB90PGBB of Make L&T or equivalent Model of Make: Switron / Recom /Kaycee / Areva)
Supply Only, heater with heater switch & thermostat suitable for 11KV VCB panels, 80 watts, as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/ Seimens/ITE/ Andrew Yule)
Supply Only, HT Current Transformers, single phase indoor solid state (Resin cast) 11 KV, ratio 150/5A, accuracy class 5P10, rated burden 15VA, STC 13.1 KA for 1second,suitable for VCB Panels as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/ Andrew Yule)
Supply Only,microprossesor based feeder protection neumerical relay with overcurrent, earth-fault, phase-discontinuity, negative-phase sequence and thermal-overload protections, inrush current detection, reclosing and measurement,preconfigured functionality facilitates, configurable binary inputs/outputs using local HMI or communication interface,modbus and IEC 60870-5-103 protocols supports,universal power supply 24-265 V AC/DC,suitable for 11 KV VCB panels,complete all as specified. (Cat No REJ601 of Make ABB or equivalent Model of Make: Schneider/ Seimens)
Supply Only,auxiliary relay with high-speed operation,rated voltage 24Volts DC,operating range - 30% to +10% of rated voltage,frequency 50 Hz +/-5%,pick-up voltage < 80%,Drop-off voltage > 20% ,Pick-up time 20-30ms,contacts 6N/O + 1N/C,suitable for 6.6 KV VCB panels,complete all as specified. type PQ8n of Make ABB or equivalent Model of Make: Schneider/ Seimens)
Supply Only,Vacuum Interrupter Assembly with Flex connection (R Phase, Y Phase & B Phase) suitable for 11 KV,630/800 Amps VCB Panels as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/ Andrew Yule)
Supply,installation,testing and commissioning of, Double break isolators 1250 Amps polymer made with hot dip galvanized coating as per IS-9921 (Part-IV)-1985 reaffirmed 2002 for 33 KV overhead line supply,complete all as specified and directed.
Supply,installation,testing and commissioning of, Motor with Gear Assembly,110 Volts/230 Volts AC (Make Bosch/ Webtool/Ralliwolf) suitable for 6.6 KV VCBs as per OEM's specifications,complete all as specified and directed. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/ Andrew Yule)
Supply Only base mounting type power pack with capacitor back up unit input voltage 230 V, output voltage 110 Volt DC, stored output 100 W sec, non store output 100W, with mains ON indicator,suitable for 11 KV VCB panels,complete all as specified. Note for items 8 to 14 (i) Contractor shall submit Test Certificate against each items.
Supply Only, fibre panel spout, 12Kv,50/60 Hz,suitable for 11 KV, 630/800 Amps VCB Panels (ABB VD4 11KV Monobloc 1250Amps) as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/ Andrew Yule)
Supply only Finger contact suitable for 11 KV, 630/800 Amps VCBs (Vacuum Switchgear Type VMX) as per OEM's specifications,complete all as specified.
Supply only PLA Relay suitable for 11 KV, 630/800 Amps VCBs (Vacuum Switchgear Type VMX) as per OEM's specifications,complete all as specified.
Supply only NO-NC Switch suitable for 11 KV, 630/800 Amps VCBs (Vacuum Switchgear CG) as per OEM's specifications,complete all as specified.
Supply only NO-NC Switch suitable for 11 KV, 630/800 Amps VCBs (Vacuum Switchgear Schneider) as per OEM's specifications,complete all as specified.
Supply only Rack in Rack out with stand suitable for 11 KV, 630/800 Amps VCBs (Vacuum Switchgear ) as per OEM's specifications,complete all as specified.
Supply only supporting rod suitable for 11 KV, 630/800 Amps VCBs (Vacuum Switchgear CG) as per OEM's specifications,complete all as specified.
Supply and spray Moisture absorbing spray WD-40 on electric terminals of VCB Breaker and panel and allied equipment all as specified and directed.
Supply Only, Epoxy Body, fo made of high grade epoxy resin suitable for high voltage transmission in 11 KV VCB Panel of capacity 630/800 Amps (Vacuum Switchgear Type VMX) as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/ Andrew Yule)
Supply Only,Release / Closing Coil,30V DC,suitable for 11KV/33 KV,630/800/1250 Amps rating outdoor VCB panels as per OEM's specifications,complete all as specified. (Code No.52747/2 (Old)/A 6111(New) of OEM Areva ‘Alstom’)
Supply Only,aluminium VCB pad clamp and connector with 06 (Six) Nos. of bolt with nut arrangement,suitable for 33 KV,1250 Amps rating outdoor VCB panels as per OEM's specifications,complete all as specified. (OEM:-Areva ‘Alstom’)
Materials and Labour for protection of aluminium VCB pad clamp and connector for 11KV/33 KV,400/630/800/1250 Amps rating indoor/outdoor VCB panels with with anti corrosive gel as per OEM's specifications, complete all as specified and directed. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/ Andrew Yule)
Supply,installation,testing and commissioning of,Non Latching Self Powered Numerical Protection Relay,for VCB/RMU,18 To 52 V & 75 To 250 V designed for use in unmanned substations where a dependable auxiliary power source is not available,designed to derive power for its operation from main current transformers,comprising integrated communication protocols for SCADA compliance,features of IDMT,as well as instantaneous protection for both over current & earth elements,suitable for accomplishing Digital filtering of measured quantities by using discrete Fourier analysis to suppress high frequency harmonics and transient DC components induced by faults or system operations and with front panel features of a 8-button keypad & a 16x2 LCD display for providing an easy user interface,complete all as specified and directed. [Cat No.CGI 14S of CG or equivalent Model of Make C&S/Seimens/ Schneider]
Supply Only, SF6 Interrupter Assembly with Flex connection (R Phase, Y Phase & B Phase) suitable for 11 KV,630/800 Amps RMU Panels as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/ Andrew Yule) Note:- for items No. 24, 28 &29 (i) Contractor shall submit Test Certificate against each items.
Supply only SF6 gas for 11 KV,630/800 Amps RMU Panels as per existing,complete all as specified.
Supply only Terminal Protector / Right Angle Rubber Boot 11 KV,630/800 Amps RMU Panels as per existing,complete all as specified.
Cutting of tree branch of girth exc. 20 cm but n.exc. 30 cm for clearing obstruction upto 3.00 metres from HT overhead lines throughout the route including cleaning away grass, vegetation saplings, shrubs, brush wood, around poles and stay assembly and including removing rubbish up to a distance of 50 meters out side the periphery of the area under clearance, complete all as specified and directed. Note: Length of HT Line will be measured and paid clearing shall be carried out 3 metres of both side of line
Repairs to battery charger with automatic float/boost change over suitable for charging of 110 Volts Battery Bank comprising of 55 Nos of 2 Volts,120 AH VRLA Type Batteries by removing from existing position,dismanteling of parts,periodic maintenance servicing of battery charger, rewinding of transformer with super enamelled copper wires of existing size including provision of all insulating materials and varnishing as per OEM's specifications,adjustment of short circuit & overload protections, FCBC system,contactors,relays etc.,replacement of Ammeter,Voltmeter, Indicators etc. including replacement of all internal wirings and control wirings as per OEM's specifications,re-fixing in original position,testing and commissioning, complete all as specified and directed. Note:- The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge.
Disconnecting all electrical connections form Control Room (MRS), taking down carefully parts (such as fixed contract, moving contact,spring with Teflon insert, phase coupler rod,rocker system with nylon bushes,arcing horn etc.) of switches air break,gang operated,triple pole,current rating up to 400 Amp,33000 Volts Grade,vertical/horizontal mounted,servicing lifting/ drawing mechanism by lubricating with petroleum jelly,readjustment of connection mechanisms, reconnection,commissioning and testing after repairs,complete all as specified and directed.
M&L for Servicing / Greasing of HT Switch air break ( GOD) 11 KV, TP Vertical / horizontal operated with replacement of Corroded nut Bolts, Male Female contact blade, ACSR Jumpers, making alignment of operating Mechanism for Proper ON / OFF operation of GOD and male contact including complete greasing all as directed by Engr-in-Charge.
Supply and Fix in repairs,switches air break, gang operated, triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating up to 200 Amp, 11000 Volts Grade,complete all as specified and directed.
Supply and Fix in repairs,switches air break, gang operated, triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating up to 400 Amp, 11000 Volts Grade, complete all as specified and directed.
Supply and Fix in repairs,drop out fuse (DO Fuse),11000 Volts grade with mounting channel,post insulator caps,DO Fuse barrel holder,fiber glass tube DO fuse barrel with heavily tinned non ferrous metal parts at both the ends,DO fuse hook, brush type phosphorous bronze DO female contact, DO female contact holder,flexible copper wire,02(Two) Nos 11KV porcelain post insulators,complete all as specified and directed. Cat No. REE-DO-01-11 of Make ‘Rashtriya’ or equivalent Model of Make ‘Jaipuria/BHEL]
Material and Labour for complete removal of existing painting,preparation of surfaces and applying two coats of aluminium paint over a coat of red oxide zinc chrome primer on prepared surfaces of steel tubular swaged poles, type 410 SP-55 (11.00 Metres Long) in HT Two Pole Structure up to PCC base including cross arms, bracings,clamps etc.,complete all as specified and directed.
Material and Labour for complete removal of existing painting,preparation of surfaces and applying two coats of aluminium paint over a coat of red oxide zinc chrome primer on prepared surfaces of steel tubular swaged poles, type 410 SP-55 (11.00 Metres Long) in HT Three Pole Structure up to PCC base including cross arms, bracings, clamps etc.,complete all as specified and directed.
Material and Labour for complete removal of existing painting,preparation of surfaces and applying two coats of aluminium paint over a coat of red oxide zinc chrome primer on prepared surfaces of steel tubular swaged poles, type 410 SP-55 (11.00 Metres Long) in HT Four Pole Structure up to PCC base including cross arms,bracings,clamps etc.,complete all as specified and directed.
Material and Labour for complete removal of existing painting,preparation of surfaces and applying two coats of aluminium paint over a coat of red oxide zinc chrome primer on prepared surfaces of steel tubular swaged poles, type 410 SP-55 (11.00 Metres Long) in HT Twenty Four Pole Structure up to PCC base including cross arms,bracings,clamps etc., complete all as specified and directed.
Materials and Labour for cross arms, bracings, supports clamps and back plates fabricated from structural steel section including nuts, bolts, washers,welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of Aluminium paint over a coat of red-oxide, zinc chrome primer complete all as specified and directed.
Supply and Fix, composite polymer disc insulator,33 KV,creepage distance 340 mm,cantilever strength 70/90 kN,conforming to IEC:61109,complete all as specified and directed. Make ‘Rashtriya’ or equivalent Model of Make ‘Jaipuria/BHEL/Supreme’]
Supply and Fix,pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 150mm height, 150 mm dia for 11000 volts grade,complete all as specified and directed.
Detecting carefully the fault location of HT UG cable of any size either HT cable fault locator machine or any other method and taking out the / remove the faulty portion of cable from undergound /duct including relaying with old cable cover, meggering / connecting / testing after repair complete all as specified and directed by Engr-in charge. Note:-(i) Excavation & earth work shall be measured and paid separately (ii) Stright throught joint for HT cable shall be measured and paid seperatly under respective item of this schedule (iii) Actual detected fault shall be paid under this item, Dummy located trail will not allowed or measured.
Taking out old HT cable from duct/trench of any size of cable as per dierected by Engr-in-charge.(Note Earth work shall be measured and paid seprately)
Material and labour including testing XLPE insulated screened , PVC bedded , galvanised steel strip or wire armoured , electric power cables (heavy duty) with aluminium conductor, 11000 Volts (Earthed), grade cross sectional area 185 Sqmm 3 core complete all as specified and directed.Make Polycab/Mescab/Crystal/Havells
Material and labour including testing XLPE insulated screened , PVC bedded , galvanised steel strip or wire armoured , electric power cables (heavy duty) with aluminium conductor, 11000 Volts (Earthed), grade cross sectional area 95 Sqmm 3 core complete all as specified and directed.Make Polycab/Mescab/Crystal/Havells
Excavation in trenches,not exceeding 1.5 m wide and not exceeding 1.5 M depth for foundation etc or for shafts wells, cesspits, manholes pier holes etc n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils. ( Note : The top of filled trench shall be made proud by using the complete excavated soil to cater for subsequent settlement of soil)
Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point.
M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid for).
Supplying and laying un-reinforced precast concrete cable cover but class HV, Type 1, flat, size 300mmx l80mm x 40mm
Re-Laying/Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 11000 Volt Grade, Nominal Cross-Sectional Area 95 Sqmm 3 core to 185 sqmm 3 core, complete all as specified and as directed.
M&L for relaying of Old PCC slab of any size, complete all as specified and directed.
S&F Galvanised Iron Pipe 80mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed.Make : JINDAL/BANSAL/NTL.
Disconnecting and cutting down the existing unserviceable /burnt out HT cable straight through joints of 50 Sqmm to 95 sqmm 3 core, supply and jointing HT cable straight through joints (Heat shrinkable) 11 KV grade suitable for XLPE cables of size 50 Sqmm to 95 sqmm 3 core including testing complete all as directed. Make : RAYCHEM/M-SEAL/3M
Disconnecting and cutting down the existing unserviceable /burnt out HT cable straight through joints of 120 Sqmm to 185 sqmm 3 core, supply and jointing HT cable straight through joints (Heat shrinkable) 11 KV grade suitable for XLPE cables of size 120 Sqmm to 185 sqmm 3 core including testing complete all as directed. Make : RAYCHEM/M-SEAL/3M
Disconnecting and cutting down the existing unserviceable /burnt out HT cable indoor type joints of 50 Sqmm to 95 sqmm 3 core, supply and jointing HT cable indoor type joints (Heat shrinkable) 11 KV grade suitable for XLPE cables of size 50 Sqmm to 95 sqmm 3 core including testing complete all as directed. Make : RAYCHEM/M-SEAL/3M
Disconnecting and cutting down the existing unserviceable /burnt out HT cable outdoor type joints of 50 Sqmm to 95 sqmm 3 core, supply and jointing HT cable outdoor type joints (Heat shrinkable) 11 KV grade suitable for XLPE cables of size 50 Sqmm to 95 sqmm 3 core including testing complete all as directed. Make : RAYCHEM/M-SEAL/3M
Disconnecting and cutting down the existing unserviceable /burnt out HT cable indoor joints of 120 Sqmm to 185 sqmm 3 core, supply and jointing indoor type through joints (cold shrinkable) 11 KV grade suitable for XLPE cables of size 120 Sqmm to 185 sqmm 3 core including testing complete all as directed. Make : RAYCHEM/M-SEAL/3M.
Demolition old damaged Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description, (in any position) and removing the same from site(s), complete all as specified and as directed.
Cement Concrete 1:2:4 (12.5mm graded Stone Aggregate) as in Kerbs, Coping, etc. Chamfered Edges including Formwork if required, complete all as specified and as directed.
M&L Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 METRE mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
M&L for Pea gravel 10mm size, spreading the same all as directed by Engr-in-Charge.
Singhs Construction (BID ID -3439001)
MAHANTA ENTERPRISES (BID ID -3445240)
VARNI BUILDERS (BID ID -3445710)
M/S MECHANICAL ENGINEERING and ELECTRICAL CONTRACTORS (BID ID -3446119)
kabitaconstruction (BID ID -3445285)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .