Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC D NO 29 2 43 SING HOTEL JUNCTION CMR ROAD VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹17.8 L+₹39,488 (2.27%)Rejected-Finance D NO 38 39 86 3 4 SAIKRUPA RESIDENCY 104 AREA BAPUJI NAGAR MARRIPALEM VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹18.6 L+₹1.2 L (7.16%)Rejected-Finance D NO 4 96 40 27 FLAT NO 307 GREEN CASTLE APARTMENT GOPALAKRISHNA NAGAR SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹19.3 L+₹1.9 L (10.7%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹19.3 L+₹1.9 L (11.1%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹32.8 L
EMD Value
₹65,600
Closing Date
29 Sept 2022, 6:00 pmClosed
GE (I) DM
GARRISON ENGINEER I DOCKYARD MAINT NAVAL DOCKYARD VISAKHAPATNAM 530 014
REPAIR AND PERIODICAL MAINTENANCE OF LT PANEL BOARDS AND REPAIR/REPLACEMENT OF ACB/MCCB/INDICATOR/METERS /CABLES / EARTHINGS AT CERTAIN BUILDING AT ZONE-1, 2, 5 AND 9 AND ALLIED WORKS AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2022_MES_550723_1
SSGE/8692/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NAVAL DOCKYARD VISAKHAPATNAM
As per tender documents
8 documents required · 8 mandatory
₹500
GE (I) DM VISAKHAPATNAM
₹65,600
Yes
10 Nov 2022
8 Sept 2022
6 Oct 2022
8 Sept 2022
29 Sept 2022
22 Sept 2022
Amount
Servicing, repair, maintinance of Air Circuit Breaker 400 Amps to 1600 Amps capacity by drawing out movable unit, forced air cleaning of movable and fixed unit, decarbonize breaker contracts and checking for any defects due to any flush/loose contact, cleaning of all fixed and moving contact point, terminal connection points with CTC, replacement of defective parts and re-fixing ACB, cables completes all as specified and as directed. Note: (a) required male/female ACB contacts, trip coils, closing coils, electronic protection unit will be measured as supply only. (b) all cleaning agents are included in the quoted rate.
Supply only fixed contract of ACB 630A to 1250A complete all as specified and as directed
Supply only Moving contract of ACB 630A to 1250A complete all as specified and as directed
Supply Only Electronic protection unit of ACB 630A to 1250A complete all as specified and as directed
Supply Only shunt trip coil of ACB 630A to 1250A complete all as specified and as directed
Supply Only closing coil ACB 630A to 1250A complete all as specified and as directed
Supply only LED Pilot lamps red, yellow and blue in colours of 22.5 mm dia to monitor on LT panel board suitable for 230 V AC supply complete all as specified and as directed. Cat Part No:-1SFA619402R5231/32/33 Make:-Siemens/ C&S/ schneider/ ABB/ L&T/ Selzer
Supply only metering current transformer of 1000/5 Amps, Class-1, 15VA, complete all as specified and as directed. Make:-Rishabh, Cat No- TW-06 or equivelent of Kappa/ AE
Supply only metering current transformer of 800/5 Amps, Class-1, 15VA, complete all as specified and as directed Make:-Rishabh, Cat No- TW-06 or equivelent of Kappa/ AE
Supply only metering current transformer of 600/5 Amps, Class-1, 10VA, complete all as specified and as directed Make:-Rishabh, Cat No- TW-06 or equivelent of Kappa/ AE
Supply only metering current transformer of 400/5 Amps, Class-1, 12.5VA, complete all as specified and as directed Make:-Rishabh, Cat No- TW-05 or equivelent of Kappa/ AE
Supply only metering current transformer of 300/5 Amps, Class-1, 5VA, complete all as specified and as directed Make:-Rishabh, Cat No- TW-05 or equivelent of Kappa/ AE
Supply only metering current transformer of 200/5 Amps, Class-1, 1.5VA, complete all as specified and as directed. Make:-Rishabh, Cat No- TW-05 or equivelent of Kappa/ AE
Supply only metering current transformer of 100/5 Amps, Class-1, 2.5VA, complete all as specified and as directed Make:-Rishabh, Cat No- TW-03 or equivelent of Kappa/ AE
All as per item No 17.00 above but of size above 1.5m x 1.5m upto 2.0m x 2.0m complete all as specified and as directed
All as per item No 17.00 above but of size above 2.0m x 1.5m upto 2.0m x 2.5m complete all as specified and as directed
All as per item No 17.00 above but of size above 2.5m x 2.5m upto 3.5m x 3.5m complete all as specified and as directed
All as per item No 17.00 above but of size above 4.5m x 4.5m upto 5.5m x 5.5m complete all as specified and as directed
All as per item No 17.00 above but of size above 5.5m x 5.5m upto 6.5m x 6.5m complete all as specified and as directed
Supply only MCCB, 4 pole, 400 amp, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with micrologic 2 trip unit, Make- Schneider cat Part No- LV432677 or equivelent of Legrand/ABB complete all as specified and as directed
Supply only MCCB, 4 pole, 250 amp, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with micrologic 2 trip unit, Make- Schneider cat Part No- LV431780 or equivelent of Legrand/ABB complete all as specified and as directed
Supply only MCCB, 4 pole, 200 amp, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic release, Make- Schneider cat Part No- LV431641 or equivelent of Legrand/ABB complete all as specified and as directed
Supply only MCCB, 3 pole, 400 amp, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with micrologic 2 trip unit, Make- Schneider cat Part No- LV432676 or equivelent of Legrand/ABB complete all as specified and as directed
Supply only MCCB, 3 pole, 250 amp, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic trip unit, Make- Schneider cat Part No- LV431630 or equivelent of Legrand/ABB complete all as specified and as directed
Supply only MCCB, 3 pole, 200 amp, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic trip unit, Make- Schneider cat Part No- LV431631 or equivelent of Legrand/ABB complete all as specified and as directed
Supply only MCCB, 3 pole, 100A, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic trip unit, Make- Schneider cat Part No- LV429630/32/35 or equivelent of Legrand/ABB complete all as specified and as directed
Supply only MCCB, 3 pole, 63A , 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic trip unit, Make- Schneider cat Part No- LV429630/32/35 or equivelent of Legrand/ABB complete all as specified and as directed
Supply only MCCB, 3 pole, 32 A , 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic trip unit, Make- Schneider cat Part No- LV429630/32/35 or equivelent of Legrand/ABB complete all as specified and as directed
Supply only switch disconnector fuse unit, TPN, open execution, bolted fuse link, 415V, confirming to IS/IEC 60947-3, telescopic shaft for depth adjustment, terminal shrouds on both side, door interlock facility of current rating 63 amps including bolted HRC fuse- 03 Nos. Make- L&T, cat No- FN-32-TPN-SK-95653 & HRC fuse-ST-34529 or equivelent of Siemens/ABB/havells
All as per item No 32 but of current rating of 125 Amps included bolted HRC fuse-03 Nos Make-L&T Cat No-FN125-TN-5Y 95009 & HRC fuse - ST - 30769/Siemens/ABB/Havells
Supply and fix Aluminium bus bar off sizes inside busbar chamber with all required nuts-bolts-washers and taking out old unserviceable bus bar complete all as specified and as directed
M&L for painting of outer surface of complete LT Panel board of size upto 1.5m x 1.5 m comprising ACBs/MCCBs/SDFs, busbar chamber, swich gear chamber, metering chamber cable termination/tray using one coat of synthetic enamel spray painting after preparation of surface, providing protection cover to all metering equipment, switchgears, cleaning of all non-metalic surface after completion of painting with paint remover complete all as specified and as directed
All as per item No 35.00 above but of size above 1.5m x 1.5m upto 2.0m x 2.0m complete all as specified and as directed
All as per item No 35.00 above but of size above 1.5m x 1.5m upto 2.5m x 2.5m complete all as specified and as directed
All as per item No 35.00 above but of size above 2.5m x 2.5m upto 3.5m x 3.5m complete all as specified and as directed
All as per item No 35.00 above but of size above 4.5m x 4.5m upto 5.5m x 5.5m complete all as specified and as directed
S/F of LT heat shrink straight through cable joint suitable for cable size LT 1100 volts grade, 4 core, 6 to 16 sqmm all as specified and directed.Make 3M, cat No MHS/Ox1.1KV(HSLA-1/4C) or equivelent of Denson/M Seal/MS Seal/RPG complete all as specified and as directed
All as per item No 40.00 but for cable sizes 25- 50 sqmm. Make 3M, cat No MHS/Ox1.1KV(HSLA-2/4C) or equivelent of Denson/M Seal/MS Seal/RPG complete all as specified and as directed
All as per item No 40.00 but for cable sizes 70-120 sqmm. Make 3M, cat No MHS/Ox1.1KV(HSLA-3/4C) or equivelent of Denson/M Seal/MS Seal/RPG complete all as specified and as directed
All as per item No 40.00 but for cable sizes 150-185 sqmm. Make 3M, cat No MHS/Ox1.1KV(HSLA-5/4C) or equivelent of Denson/M Seal/MS Seal/RPG complete all as specified and as directed
All as per item No 40.00 but for cable sizes 240 to 300 sqmm. Make 3M, cat No MHS/Ox1.1KV(HSLA-5/4C) or equivelent of Denson/M Seal/MS Seal/RPG complete all as specified and as directed
All as per item No 40.00 but for cable sizes 400 to 500 sqmm. Make 3M, cat No MHS/Ox1.1KV(HSLA-6/4C) or equivelent of Denson/M Seal/MS Seal/RPG complete all as specified and as directed
S/F heat shrink indoor cable protection tube single core coloured (R-Y-B-Black), suitable for cable size 16 sqmm to 240 sqmm complete all as specified and as directed
M&L for Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in 1:6 cement morter for panel foundation incl dismantling taking out unsv one complete all as specified and as directed
M&L for rendering 10mm thick in CM 1:6 plaster on fair faces of brick work or concrete surfaces incl dismantling taking out unsv plaster complete all as specified and as directed
Supply and fix rubber insulating mat in front of LT panel board of size 2 mm thick, 1m width upto 3.3 KV, Make- RPG or equivelent as approved by GE complete all as specified and as directed
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc. as required of size 25x4mm galvanised iron strip including taking down unserviceable one complete all as specified and as directed
M&L for dismantling and taking out all cable connection from all switchgear and earthing connection of the indoor panel board, removing carefully the complete panel board of size not less than 2.5 m x 2 m using sufficient man power from base of panel and keeping aside, re-construction of damaged panel foundation in same place or other specified location with brick-work, plaster, foundation bolt, white wash to new plastered surface, reinstallation of complete panel and necessary cable end connection to respective switchgears, earthing complete. Note- (i) Relaying of cables due to change of foundation of panel shall be measured and paid separately (ii) required additional length of cables shall be measured and paid separately, (iii) cable joints if require will be measured and paid separately, (iv) required aluminium cable lugs, nuts, bolts and washers, foundation bolts, white wash will be inclusive of quoted rate (v) Brick work/plaster work will be measured and paid separately
M&L for dismatling and relaying of cable off sizes after opening loop, on cable tray/wall/floor with proper clamp complete all as specified and as directed
S & F Hot dip Galvanised wire mesh cable trays 105 x 300 complete with tray, coupler, cover and cover clip to support clamps, securing properly to support strcture complete including dismanling from building wall more than 3 mtr hieght form floor complete all as specified and as directed
Supply, laying in cable trey/wall & connection PVC XLPE insulated, armoured havey duty electric cable with aluminium conductor, 1100 Volts grade cross section area 10 Sqmm 4 core including dismantling taking down unsv one from wall, cable trey, trench complete all as specified and as directed
All as per item No 54.00 but of size 16 sqmm, 4 core complete all as specified and as directed
All as per item No 54.00 but of size 25 sqmm, 4 core complete all as specified and as directed
All as per item No 54.00 but of size 35 sqmm, 4 core complete all as specified and as directed
All as per item No 54.00 but of size 50 sqmm, 3.5 core complete all as specified and as directed
All as per item No 54.00 but of size 70 sqmm, 3.5 core complete all as specified and as directed
All as per item No 54.00 but of size 120 sqmm, 3.5 core complete all as specified and as directed
All as per item No 54.00 but of size 240 sqmm, 3.5 core complete all as specified and as directed
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .