Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC 2 65 GORWA UDAYPARK SOCIETY REFINERY ROAD VILLAGE TOWN VADODARA CITY VADODARA VADODARA GUJARAT 390016 INDIA | VADODARA | GUJARAT | 390016 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹22.9 L+₹1.2 L (5.75%)Rejected-Finance C 17 UPPER GROUND FLOOR C BLOCK COMMUNITY CENTRE JANAK PURI JANAK PURI JANAK PURI WEST DELHI DELHI 110058 | WEST DELHI | DELHI | 110058 | L2 | Rejected-Finance Being 2nd Lowest | |
| 3 | L3₹24.3 L+₹2.7 L (12.3%)Rejected-Finance | L3 | Rejected-Finance Being 3rd Lowest | |
| 4 | L4₹26.8 L+₹5.2 L (23.9%)Rejected-Finance OLD JAIL ROAD NEAR JILA GARDEN RAJKOT 360001 | RAJKOT | GUJARAT | 360001 | L4 | Rejected-Finance Being 4th Lowest | |
| 5 | L5₹28.1 L+₹6.5 L (29.8%)Rejected-Finance 7 1 3RD AND 4TH FLOOR MAGADI MAIN ROAD NEAR MAGADI ROAD METRO STATION NEAR MAGADI ROAD METRO STATION BANGALORE KARNATAKA 560023 | BENGALURU URBAN | KARNATAKA | 560023 | L5 | Rejected-Finance Being 5th Lowest |
Tender Value
₹28.9 L
EMD Value
₹57,720
Closing Date
23 Aug 2022, 3:00 pmClosed
Office of AGM(E-E), AAI, Surat Airport, Surat
Office of AGM(E-E), AAI, Surat Airport, Surat
Relay calibration, filtration of transformer and Servicing/overhauling of ACBs and HT breakers at Surat airport.
2022_AAI_119854_1
AAI/SRT/AGM(E-E)/eNIT-04/22-23
Open Tender
Electrical Works
Item Rate
60 days
AAI, Surat Airport
As per NIT
19 documents required · 19 mandatory
₹1,180
Yes
₹57,720
Yes
12 Nov 2022
29 Jul 2022
24 Aug 2022
29 Jul 2022
23 Aug 2022
29 Jul 2022
29 Jul 2022 - 19 Aug 2022
Amount
Servicing, Testing and checking of Vaccum Circuit Breakers Servicing, Testing , checking of 3 Ph , 400A ,22KV,13.1 KA (3 second) HT Vacuum Circuit Breaker (VCB) including testing of wiring, minor repairing works ,dismentaling of existing defective parts,replacement of defective parts/spares,making connection,documenting the testing , submission of test reports as per recommended standards through authorised agency of OEM/agency approved by Engineer-In-Charge etc. complete as required . Make & Model of existing VCB: AREVA -PIX-36, ( NOTE:- required spares of HT breakers shall be provided by AAI for the replacement of the defective components/spares of the VCB).
Repairng of rack-in and Rack-out mechanism/system of existing 3 Ph, 400A ,22KV,13.1 KA (3 second) HT Vacuum Circuit Breaker (VCB) including welding cutting, making alignment etc as required as per the site requirement. Make & Model of existing VCB: AREVA -PIX-36, ( NOTE:-Repairing works shall be carried out at the site only during the shutdown period allowed).
Supply of followings spare parts suitable for existing 3 Ph , 400A ,22KV,13.1 KA (3 second) HT Vacuum Circuit Breaker (VCB) ,as and when required basis during the currency of the contract. Make & Model of existing VCB: AREVA -PIX-36
CAM Disc complete
Current tranformer with CT ratio: 100-50/5A, Class-1, Burden-15 VA
Current tranformer with CT ratio:100-50/5A, Class-10P10, Burden-15 VA
Potential transformer with range: 22kV/110V
Ramp hook assembly
Glide
Bearing block outline
Spur Gear
Closing /tripping coil-24/30 V DC
Motor 220 V DC
Gear Assembly
Pole Assembly
Thermostat for space heater
Space heater,230 V AC/DC
Limit Switch with 1 NO+1NC for Service / Test position
Handle assembly
Spout
Handle
Primary Shaft
Spring Charging Drum
Servicing, Testing and checking of Transformers Servicing ,Testing , checking , replacement of defective parts/spares of 500 kVA ,22/0.415 kV kirloskar make Transformer including testing of wiring ,minor repairing works,documenting the testing , submission of test reports as per recommended standards through authorised agency of OEM/agency approved by Engineer-In-Charge etc. complete as required. Testing includes Insulation Resistance test, Voltage Ratio & Tap Continuity test, Magnetic Balance Test, Vector Group Test, Accessories working etc. ( NOTE:- required spares of transformer shall be provided by AAI for the replacement of the defective components/spares).
Dehydration and filtration of 500 KVA Kirloskar make oil filled Transformer including testing of BDV(before and after) , acidity test and submission of reports through authorised agency of OEM/agency approved by Engineer-In-Charge etc. complete as required .
Supply of tested transformer oil for topping up in the transformer if required.
Supply of followings spare parts suitable for existing 500 kVA ,22/0.415 kV kirloskar make oil filled tranformer as and when required basis during the currency of the contract .
HV Bushing With metal part set.
LV Bushing With metal part set
Silica gel Breather
Oil temp. Indicator
Winding temp. Indicator
Neutral bushing with metal part
Buchholz Relay
Magnetic Oil Level Gauge
Prismatic Oil Level Gauge
Servicing, Checking ,testing of 195kVAR automatic power factor correcting , including replacment of defective power capacitor and other defective compnents / spares documenting the testing , submission of test reports as per recommended standards through authorised agency of OEM/agency approved by Engineer-In-Charge etc. complete as required . ( NOTE:- required spares of APFC shall be provided by AAI for the replacement of the defective components/spares).
Supply of the follwing component/spares suitable to Existing APFC panel as and when required basis during the currency of the contract .
3 Phase, 440V, 50Hz box type ultra heavy duty capacitors with APP technology, Lower operating losses - 0.35 W / kVAr, High over current withstand capability - 3 times rated current, High inrush current withstand capability- 500 times rated current in the modules of 10/30/40/75/100 KVAR suitable for the installation in the existing cabinet/housing of the APFC panel. Note:- Size of capacitor bank should be suitable to the existing capacitor housing of the APFC panel to accommodate the capacitor bank.
Thyristor firing module
Exhaust fan (Size:- 4 to 6 inch to suit the existing of the exhaust fan)
6 stage automatic Power factor correction high speed relay
Servicing, Testing and checking of Breakers Servicing, Checking and Testing of the LT air circuit breakers up to 800 Amp rating including testing of wiring of breaker , minor reparing works complete as required including documenting the testing , submission of test reports as per recommended standards through authorised agency of OEM/agency approved by Engineer-In-Charge etc. complete as required .
800 A, 55 KA Breaking capacity No. USP800 make (Make : GE)
800 A, 55 KA Breaking capacity Model No. Spectronic-800A (Make :GE)
800 A, 55 KA Breaking capacity Model No. UW1-08N (Make :Omega)
Inspection, servicing, setting, calibration and testing of the following different types of relays using secondary injection method and adjustment of plug setting and including documenting the testing , submission of test reports as per recommended standards through authorised agency of OEM/agency approved by Engineer-In-Charge etc. complete as required .
IDMT relay ( 02 OC and 01 EF) of HT/LT panels
Auxiliary / Master Trip /Alarm Trip circuit relay of HT panel
IDMT Electronic relay (make : L&T) of LT Panels
Microprocessor based release Model & make :-UW-MTX1G- L&T
Supply of the following spares parts suitable for existing essential/non - essential panels as and when required basis during the currency of the contract .
0-400 A,400/5A,3⌀,MI,type 144 sqmm , Ammeter
0-300A,300/5A,3⌀,MI,type 96 sqmm , Ammeter
0-500 V,MI,type 144 sqmm , Voltmeter
S. N. ELECTRIC & MAINTENANCE PRIVATE LIMITED
Adarsh electric works
DOSHI ELECTRIC ENGG. CO.
ARK POWER SOLUTIONS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .