Loading…
Loading…
Tender Value
₹15.4 L
EMD Value
₹15,361
Closing Date
30 Sept 2026, 5:00 pm7d left
Superintending Engineer (CG), GIDC, Bharuch
Supply Installation Testing & Commissioning and Renovation of necessary for Electrical Work at GIDC New Colony Staff Quarters necessary Electrical work at GIDC Ankleshwar.
344110
E-Tender Notice No. 05 of 2026-27 Sr. No. 09
Open
Mechanical - All
Works
Bharuch
2 documents required · 2 mandatory
₹1,062
Executive Engineer, GIDC, Ankleshwar
₹15,361
10 Sept 2026
10 Sept 2026
10 Sept 2026
30 Sept 2026
10 Sept 2026
NAME OF WORK: Supply Installation Testing & Commissioning and Renovation of necessary
for Electrical Work at GIDC New Colony Staff Quarters necessary Electrical
work at GIDC Ankleshwar.
( VOLUME – III ) PRICE BID
ONLINE TENDER PAPERS
1 Estimated cost : Rs.
2 Tender fee (Rs. 900 Basic+ 18 % GST 162) : Rs.
4 Last date on (or before) which the tender along-with : From 17th August 2026 to
DD / FDR for Tender fees & EMD (by scanning) and 30th September 2026 up
other required documents must upload on the web site to 17.00 hours
of www.nprocure.com
5 Date on (or before) which DD/FDR in original for : From 01st October
Tender fee & EMD and other required documents must to 06th October 2026 up
reach in the office of the EXECUTIVE ENGINEER (M&E) to 17.00 hours (Only
2nd FLOOR, NARMADA COMMERCIAL COMPLEX, Working Days)
ABOVE CENTRAL BANK, M.G.ROAD, PANCH BATTI,
02642 – 241902 ) E-Mail:- xenme-
6 Eligible class of Registered : Bidder should be as per
Prequalification criteria for
Work- (2.1) Eligibility and
Having similar Experience
EXECUTIVE ENGINEER (M&E)
2nd FLOOR, NARMADA COMMERCIAL COMPLEX,
ABOVE CENTRAL BANK, M.G.ROAD, PANCH BATTI, GIDC, BHARUCH.
E-Mail:- [email protected]
Signature of Contractor Executive Engineer (M&E)
Name of Work: Supply Installation Testing & Commissioning and Renovation of necessary for
Electrical Work at GIDC New Colony Staff Quarters necessary Electrical work at
GIDC Ankleshwar.
Sr. Description Qty Unit Rate(Rs) Amount(Rs)
1 Point wiring for Light / Fan/ Bell/ 288 Pt. 336.00
Primary Point with 2-1.5 sq. mm &
earth wire of 1.5 sq. mm (green) both
are of ISI marked 1.1 kv grade FRLS
PVC insulated multi strand copper wires
upto max length of 10 mt, in below type
of pipe erected with 6A Tissino Type ISI
marked flush type switch / bell push and
accessories erected on Metal /
PVC/Wooden Box covered with 3 mm
thick PC(Polycarbonate)
/Acrylic/Laminated sheet. with
necessary Lamp holder/ceiling rose /
H.D.Connector as directed. ( h) with oval
conduit /PVC casing capping double lock
type erected concealed in wall/ceiling
2 Point wiring for FAN with 2-1.5 sq.mm & 72 Pt. 596.00
earth wire of 1.5 sq.mm (Green) both
are of .ISI marked 1.1 KV Grade FRLS
PVC insulated multi strand copper wires
up to 10 mtr length, in below type of
pipe erected with 6A Modular type
switch and hum free EME step type
electronic fan regulator mounted and
accessories with earth continuity of
following type erected on PVC /
Metallic/Wooden box, single mounting
base frame covered with
textured/metallic/white front plate
modules erected on / in wall / ceiling as
per pipe erected. with necessary ceiling
rose / H.D.Connector as directed.(c)
with oval conduit /PVC casing capping
double lock type erected flushed on
wall/ceiling complete
3 Point wiring for Looped Plug with 6A 216 Pt. 258.00
Modular type switch & 5 pin socket
erected on PVC / Metallic box, single
mounting base frame covered with
textured / metallic front plate modules
erected on / in wall / ceiling with
Signature of Contractor Executive Engineer (M&E)
following type accessories
4 Supplying & erecting UPVC Mini 4320 Rmt. 31.00
trunking (PVC Casing-n-Capping) having
double-locking arrangement with
grooves, trunking of size not below
mm in height as per IS with accessories
of PVC/Resin polypropylene not below
1.8 mm thick duly sealed in joint &
erected on wall / ceiling of following size
5 Mains with 1.1 KV grade FRLS PVC 7080 Rmt. 57.00
insulated ISI marked stranded Copper
conductor wire in following type of pipe
to be erected concealed in /flushed on
wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated stranded
wire of green colour for earth continuity
of following size with oval conduit /pvc
casing capping double lock type 2 wire
6 do - but with oval conduit /pvc casing 2980 Rmt. 83.00
capping double lock type 2 wire 2.5 sq.
7 Providing following type of Modular 72 No. 1356.00
Type Accessories mounted with PVC /
metallic/Wooden box, single mounting
base frame covered with textured /
metallic/white front plate , modules
erected with necessary connections as
per site situation directed by Engineer In
(1)One No. SP 6 Amp. total nos 5 Cat.III
(10) 6/16Amp. Universal socket nos
(5) Electronic hum Free steps EME Fan
regulator nos 1 Cat.III
8 Providing following type of Modular 72 No. 381.00
Type Accessories mounted with PVC /
metallic/Wooden box, single mounting
base frame covered with textured /
metallic/white front plate , modules
erected with necessary connections as
per site situation directed by Engineer In
(9) 16 Amp. SP one way switch Nos
(10) 6/16Amp. Universal socket Nos
Signature of Contractor Executive Engineer (M&E)
9 Providing following type of Modular 24 No. 1054.00
Type Accessories mounted with PVC /
metallic/Wooden box, single mounting
base frame covered with textured /
metallic/white front plate , modules
erected with necessary connections as
per site situation directed by Engineer In
(1)One No. SP 6 Amp. total nos 3 Cat.III
(10) 6/16Amp. Universal socket nos3
10 -do-(1)One No. SP 6 Amp. Nos 3 24 No. 455.00
11 -do-(1)One No. SP 6 Amp. 50 No. 152.00
12 -do(11) 6 Amps. Bell Push 24 No. 152.00
13 Approved make ELCBs / RCCBs 28 No. 1970.00
conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable
for operation on single phase 240 V.
having characteristic of quick action &
tripping with all advance feature & do
not incorporate any electronic
component. for following Max. rating
erected as directed (i) 25 Amps.DP
14 providing and erecting Miniature circuit 72 No. 112.00
breaker single pole 6A to 25A suitable to
240 V A.C. system and having breaking
capacity 10 KA to be erected in existing
box. confirming to IS 8828/1996 with
ISI Mark Cat.III
15 Providing and erecting Sheet Steel 25 Ea. 583.00
powder coated MCB distribution board -
flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC
61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs
should be used of same company of MCB
suitable for (a) single door (IP-30) (ii)6
16 Supplying & erecting earth pit of 4 Ea. 5760.00
minimum bore dia.150mm size
approved make Earthing Electrode
Signature of Contractor Executive Engineer (M&E)
consisting Pipe-in-Pipe Technology as
per IS 3043-1987 made of corrosion free
hot dipped G.I.Pipes having Outer pipe
dia of 50mm having 80-200 Micron
galvanising, Inner pipe dia of 25 mm
having 200-250 Micron galvanising,
connection terminal dia of 12mm with
constant ohmic value surrounded by
highly conductive compound with high
charge dissipation suitable for following
type of applications with chamber and
heavy duty cover. (A)(approved make
OEM has to submit test certificate
including value of earth resistance of
installation duly stamped and signed by
agency and officer Incharge has to
ensure the value of earthing resistane
mentioned in test Certificate) & having
back filling compound of (B) Inner
chemical (CCM Compound)- Resistivity:-
0.2 ohm / meter testing as per IEC
62561-2017, Voltage drop:-
< 1 volt at no load & dry form, Sulphar
content:-<2%(C) Back fill Compound :-
Earthing compound should be capable to
retain moisture for long time Necessary
test report must be submitted by
Agency.(b)For Electrical installation up
to 11 KV in normal soil.
Length of Pipe : 2.00 mtrsBack filling
Compound :1 no. Bag of 25 Kg.
17 Supplying & erecting XLPE(IS:7098)(I)- 776 Rmt. 137.00
88 ISI unarmoured copper cable 1.1 KV
grade to be erected as directed of
following size. (E) 3 core 2.5 Sq. mm
18 LED INDOOR LIGHT 72 No. 374.00
FIXTURES:Supplying and erecting LED
Indoor fittings with (1) LED Luminary
should be as per below [A, B & C] with,
LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with
housing used as a heat sink shall be
made of thick sheet Steel conforming to
IS: 513/CRCA polyester powder coated
and high U.V. & corrosion resistance
with diffuser and/or Polycarbonate
optics with company mark/name 160 to
270 V,Power Factor more than 0.9, THD
Signature of Contractor Executive Engineer (M&E)
Uniformity ratio >0.7,Luminaries
efficacy> 85 lumens/watt ,LED driver
efficiency > 85 %(Each fitting required
LM-79 & LM-80 Certificates)CREE /
OSRAM / PHILIPS Lumileds / NICHIA /
SEOUL/Bridgelux(U.S.A.) make LED
used for luminaire. SITC for (A) Tube
Light with integral / non-integral driver
(III) 22 -24 Watts, Surge-2KV, IP-20,
feet, Cat-III(Make: BAJAJ / PHILLIPS /
OREVA / CG / SYSKA / HELONIX)
19 do - but LED Lamps integral type,cool 288 No. 70.00
white with PC diffuser suitable for B22
LAMP holder (a) 2 to 3 watts (Make:
BAJAJ / PHILLIPS / WIPRO / CG / SYSKA
20 Providing and erecting Approved make 48 No. 1597.00
Ceiling fan with double ball bearing ISI
mark with condenser A.C. 23OV.50
c/s.1200 mm. sweep complete, canopy
and 30 cms. down rod erected on
existing hook or clamp with 24/0.2 ,
core flexible wire with earthing. . [Make
shall be approved by Engineer in charge]
21 Supplying and erecting 19 / 20 mm. 48 No. 108.00
nominal bore Medium Class M.S. Pipe
down rod erected duly painted for fan
complete with necessary 24/ O.20,
core flexible wire with earthing.
22 Supplying & erecting Fan Hook of 10 mm 48 No. 43.00
M.S. Round bar grouted in RCC slab with
Making the site as original.
23 Supplying & erecting fan hook box of 10 48 No. 108.00
mm M.S. round bar bounded to the RCC
bars up to 50mm length each side and
pierced through a 16 Gauge M.S. box /
Heavy Duty PVC box complete erected
concealed in Ceiling with necessary
24 Supplying and erecting LED street light / 8 No. 4997.00
Flood light fittings with High power
White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency
more than 130 lm/w and corrosion free
High pressure die cast aluminum
housing with smooth finish powder
coated and heat sink extruded
Signature of Contractor Executive Engineer (M&E)
aluminium with diffuser and
Polycarbonate optics/ lenses, with
toughened glass with company
mark/name engraved or embossed
to 270 V,Power Factor more than 0.95,
THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt .
LED driver efficiency >
%.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description
have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge
may select any wattage capacity
between the ranges shown.)
(A) Street Light (IP-65), Surge
protection -4KV integral and ,Light must
have 440VAC line supply with over-
voltage protection.(ii) above 48 to
I / We agree to carry out the work at ______________________ % above the estimated tender rates
___________________________________________ should be written in figures and words.
I / We agree to carry out the work at ______________________ % below the estimated tender rates
___________________________________________ should be written in figures and words.
ESTIMATED AMOUNT ESTIMATED AMOUNT
Put to tender Rs. 1536059.00 Put to tender Rs.
Rupees in words: ___________ Rupees in words: _________________
1. (*) Please strike out whichever is not applicable. All work shall be carried out as per the
specifications of the GIDC or as directed.
2. All the columns in Schedule should be filled in ink and the total entries in the last column
should be struck by the contractor under his signature.
3. Rate quoted included clearance of site (prior to commencement of work & at, its close) in all
respect & hold good for the work under all conditions, site moisture, weather etc.
Signature of Contractor Executive Engineer (M&E)
4. I/We have read the tender/general specifications/ conditions and I/We agree to follow
same and binding to me/us.
Bidders Signature Executive Engineer (M&E),
Signature of Contractor Executive Engineer (M&E)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
MODIFIED SCHEDULE.pdf
Volume - I (PQ).pdf
Volume - II (Technical Specification).pdf
Volume - III (Price Bid).pdf
B1 Agreement - Part 1.pdf
B1 Agreement - Part 2.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .