Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹50.8 LAccepted-AOC B 148 2ND FLOOR B BLOCK NEAR MOTHER DIARY SECTOR 8 DWARKA NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L-1 | Accepted-AOC L-1 Bidder | |
| 2 | L-2₹51.1 L+₹35,648.48 (0.70%)Rejected-AOC 77 DR ZAKIR HUSAIN WARD NEAR GAZI MASJID NAI BASTI GOHALPUR JABALPUR NAI BASTI GOHALPUR JABALPUR MADHYA PRADESH 482002 | JABALPUR | MADHYA PRADESH | 482002 | L-2 | Rejected-AOC L-2 Bidder | |
| 3 | L-3₹53.2 L+₹2.4 L (4.78%)Rejected-AOC | L-3 | Rejected-AOC L-3 Bidder | |
| 4 | L-4₹57.9 L+₹7.1 L (14.0%)Rejected-AOC | L-4 | Rejected-AOC L-4 Bidder | |
| 5 | L-5₹72.6 L+₹21.8 L (43.0%)Rejected-AOC PLOT NO 37 BADANPUR OLD SER NO 34658 NEAR SAI BARAT PALACE PAWAN BHUMI SHAKTI NAGAR JABALPUR MADHYA PRADESH 482001 | JABALPUR | MADHYA PRADESH | 482001 | L-5 | Rejected-AOC L-5 Bidder |
Tender Value
₹59.5 L
EMD Value
₹1.2 L
Closing Date
4 Aug 2020, 6:00 pmClosed
AGM Engg Electrical
O/o AGM Engineering Electrical Jabalpur Airport Jabalpur 482005
Periodical Maintenance and Operation of Electrical Mechanical and Fire Fighting Installations at Jabalpur Airport Year 2020 22
2020_AAI_53577_1
AAI/WR/JBP/AGM(E-E)/eNIT-01
Open Tender
AMC/ Maintenance Contracts
Item Rate
730 days
Jabalpur Airport
As per NIT
4 documents required · 4 mandatory
₹1,120
Yes
AAI
₹1.2 L
Yes
1 Sept 2020
22 Jul 2020
8 Aug 2020
22 Jul 2020
4 Aug 2020
22 Jul 2020
22 Jul 2020 - 30 Jul 2020
Amount
Routine maintenance of all the Electrical and Mechanical installations of Power House, Switch Rooms, Fire Fighting Installations & AAI Ofices etc. as per the list of Installations attached (Except New VRV AHU, VRF & GLF system) by deploying adequate manpower on all days as mentioned in the special conditions of contract complete as per direction of Engineer- Incharge. (For the 1st year)
Routine maintenance of all the Electrical and Mechanical installations of Power House, Switch Rooms, Fire Fighting Installations & AAI Ofices etc. as per the list of Installations attached (Except New VRV AHU, VRF & GLF system) by deploying adequate manpower on all days as mentioned in the special conditions of contract complete as per direction of Engineer- Incharge. (For the 2nd year)
Dehydration AND FILTERATION of transformer Oil at site by bringing the Dehydration/ filtration Machine at Airport P/H including testing BDV and acidity before and after Dehydration and Filtration submitting of test report as required for 02 Nos 500 KVA, 33/0.433 KV Transformers (for the 1st year)
Dehydration AND FILTERATION of transformer Oil at site by bringing the Dehydration/ filtration Machine at Airport P/H including testing BDV and acidity before and after Dehydration and Filtration submitting of test report as required for 02 Nos 500 KVA, 33/0.433 KV Transformers(for the 2nd year)
Testing/ calibration of HT/LT Panel IDMT Relays type CDG-31 of GEC Alstom make (02 over Current +01 Earth fault Relay) COMPLETE BY RELAY TESTING SET at Airport Power house and submitting the test certificate complete as required.(for the 1st year)
Testing/ calibration of HT/LT Panel IDMT Relays type CDG-31 of GEC Alstom make (02 over Current +01 Earth fault Relay) COMPLETE BY RELAY TESTING SET at Airport Power house and submitting the test certificate complete as required. (For the 2nd year)
Testing/ calibration of Trip circuit supervision Relay Type VAX MK.II FOR HT panel GEC Alstom make COMPLETE BY RELAY TESTING SET at Airport Power house and submitting the test certificate complete as required.(For the 1st year)
Testing/ calibration of Trip circuit supervision Relay Type VAX MK.II FOR HT panel GEC Alstom make COMPLETE BY RELAY TESTING SET at Airport Power house and submitting the test certificate complete as required.(For the 2nd year)
Testing / calibration of Tripping Relay Type VAJ for HT Panel GEC Alstom make complete by Relay Testing set at the Airport Power house and submitting the test certificate complete as required.(For the 1st year)
Testing / calibration of Tripping Relay Type VAJ for HT Panel GEC Alstom make complete by Relay Testing set at the Airport Power house and submitting the test certificate complete as required.(For the 2nd year)
Testing/ calibration of Auxiliary Relay Type VAA for HT Panel GEC Alstom make complete by Relay Testing Set at the Airport Power house and submitting the test certificate complete as required.(For the 1st year)
Testing/ calibration of Auxiliary Relay Type VAA for HT Panel GEC Alstom make complete by Relay Testing Set at the Airport Power house and submitting the test certificate complete as required.(For the 2nd year)
Overhauling and Servicing of L&T make ACB’S of model CN-CS 800C of C- Power Series Capacity 800 A by OEM or their authorized services dealer as per manufacturers reccomandation and job includes supply of maintenance kit consist of grease, cleanent, Dusters, Scrubbers, and hardware required to carry out correct maintenance of ACB’s etc. as required.(For the 1st year)
Overhauling and Servicing of L&T make ACB’S of model CN-CS 800C of C- Power Series Capacity 800 A by OEM or their authorized services dealer as per manufacturers reccomandation and job includes supply of maintenance kit consist of grease, cleanent, Dusters, Scrubbers, and hardware required to carry out correct maintenance of ACB’s etc. as required.(For the 2nd year)
Overhauling, Servicing & control wiring correction of Seimens make VCB’S Type 3AH3 Capacity 36KV, 1250 Amp by OEM or equivalent services dealer and job includes supply of maintenance kit consist of grease, cleanent, Dusters, Scrubbers, and hardware required to carry out correct maintenance of VCB’s, replacement of damage door handle , free replacement all moveable Defective parts, Submission of Insulation Resistance (IR) ,Contact Resistance Measurement (CRM) & IR of Voccume bottle test report etc. as required.(For the 1st year)
Overhauling, Servicing & control wiring correction of Seimens make VCB’S Type 3AH3 Capacity 36KV, 1250 Amp by OEM or equivalent services dealer and job includes supply of maintenance kit consist of grease, cleanent, Dusters, Scrubbers, and hardware required to carry out correct maintenance of VCB’s,Submission of Insulation Resistance (IR) and Contact Resistance Measurement (CRM) & IR of Voccume bottle test report test report, free replacement all moveable Defective parts etc. as required.(For the 2nd year)
Rewinding of 3 HP Submersible Pump moter with suitable gauge copper wire i.c varnishing, baking etc as required i.e. transportation from site to contractors workshop & back to site. Credit towards Dismaintled copper winding to be considered while quoting the tender.
Rewinding of 5 HP Pump moter sets (submersible/ mono block ) with suitable gauge copper wire i.c varnishing, baking etc as required i.e. transportation from site to contractors workshop & back to site. Credit towards Dismaintled copper winding to be considered while quoting the tender.
Rewinding of 7.5 HP Pump moter sets (submersible) with suitable gauge copper wire i.c varnishing, baking etc as required i.e. transportation from site to contractors workshop & back to site. Credit towards Dismaintled copper winding to be considered while quoting the tender.
Rewinding of 15 HP Pump moter sets (mono block ) with suitable gauge copper wire i.c varnishing, baking etc as required i.e. transportation from site to contractors workshop & back to site. Credit towards Dismaintled copper winding to be considered while quoting the tender.
Lowering & lifting of submersible pump sets from borewell (Depth 400 to 450 feet) upto 10 HP complete as required at site.
Lighting & decoration arrangement by LED (Pleasant colourfull) on Occasion of National Festival/ Depawali /New Year /AAI Foundation day on Terminal building ,ATC Tower & Power House Including Loading ,Unloading ,Transporting & installation etc complete to the satisfaction of EIC (for the 1st year).
Lighting & decoration arrangement by LED (Pleasant colourfull) on Occasion of National Festival/ Depawali /New Year /AAI Foundation day on Terminal building ,ATC Tower & Power House Including Loading ,Unloading ,Transporting & installation etc complete to the satisfaction of EIC (for the 2nd year).
Painting of 8 Meter height street light pole with 2 coats of aluminium paint complete as required.
Supply of KOEL CARE Premium Genuine oil 50 Litres CAN ( Part No. 82.060.10.0.50) for servicing of 500 KVA KOEL Make D.G. Set under warrantee period as & when required.
Supply of KOEL CARE Premium Genuine oil 5 Litres CAN ( Part No. 82.00.10.0.05) for servicing of 500 KVA KOEL Make D.G. Set under warrantee period as & when required.
Supply of KOEL CARE Genuine coolant Premix 26 LTR CAN ( Part No. 82.020.35.1.26) for servicing of 500 KVA KOEL Make D.G. Set under warrantee period as & when required.
Supply of Spinon fule Filter assly( Part No. DV8040.24.0.00) for servicing of 500 KVA KOEL Make D.G. Set under warrantee period as & when required.
Supply of Fuel Filter Cartridge ( Part No. DV0.020.03.0.00) for servicing of 500 KVA KOEL Make D.G. Set under warrantee period as & when required.
Supply of Lube oil Filter ( Part No. DV0.014.11.0.00) for servicing of 500 KVA KOEL Make D.G. Set under warrantee period as & when required.
Supply of Lube oil Filter ( Part No. DV0.020.27.0.00) for servicing of 500 KVA KOEL Make D.G. Set under warrantee period as & when required.
Supply of Air Filter Primary (Part No:-F6.404.27.0.00) for servicing of 500 KVA KOEL Make D.G. Set under warrantee period as & when required.
Supply of Air Filter Safety (Part No:-F6.404.28.0.00) for servicing of 500 KVA KOEL Make D.G. Set under warrantee period as & when required.
Supply of V wrapped Belt SPB AR 1170 (Part No:- DV2.016.1.0.00) for servicing of 500 KVA KOEL Make D.G. Set under warrantee period as & when required.
Supply of V Belt - BX58 PITCH 1520 LONG (Part No:-DV0.016.08.0.00) for servicing of 500 KVA KOEL Make D.G. Set under warrantee period as & when required.
Execution of works as per CPWD DSR 2018 ( E& M) & Latest CPWD Specifications . CPWD DSR ( E&M) 2018 items of Chapter 1 to 10, 14 & 17. Rate shall be quoted as mentioned in clause 37 of GTT. (For first Year)
Execution of works as per CPWD DSR 2018 ( E& M) & Latest CPWD Specifications . CPWD DSR ( E&M) 2018 items of Chapter 1 to 10, 14 & 17. Rate shall be quoted as mentioned in clause 37 of GTT. (For second Year)
ROSHAN REFRIGERATION AND ELECTRICALS
SHRADDHA ENGINEERING AND FACILITY SERVICES
ABHISHEK ASSOCIATES
Zamzam Refrigeration and airconditioning
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .